Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Environ Int ; 172: 107693, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36701835

RESUMEN

Plastic pollution has long been identified as one of the biggest challenges of the 21st century. To tackle this problem, governments are setting stringent recycling targets to keep plastics in a closed loop. Yet, knowledge of the stocks and flows of plastic has not been well integrated into policies. This study presents a dynamic probabilistic economy-wide material flow analysis (MFA) of seven plastic polymers (HDPE, LDPE, PP, PS, PVC, EPS, and PET) in Norway from 2000 to 2050. A total of 40 individual product categories aggregated into nine industrial sectors were examined. An estimated 620 ± 23 kt or 114 kg/capita of these seven plastic polymers was put on the Norwegian market in 2020. Packaging products contributed to the largest share of plastic put on the market (∼40%). The accumulated in-use stock in 2020 was about 3400 ± 56 kt with ∼60% remaining in buildings and construction sector. In 2020, about 460 ± 22 kt of plastic waste was generated in Norway, with half originating from packaging. Although ∼50% of all plastic waste is collected separately from the waste stream, only around 25% is sorted for recycling. Overall, ∼50% of plastic waste is incinerated, ∼15% exported, and ∼10% landfilled. Under a business-as-usual scenario, the plastic put on the market, in-use stock, and waste generation will increase by 65%, 140%, and 90%, respectively by 2050. The outcomes of this work can be used as a guideline for other countries to establish the stocks and flows of plastic polymers from various industrial sectors which is needed for the implementation of necessary regulatory actions and circular strategies. The systematic classification of products suitable for recycling or be made of recyclate will facilitate the safe and sustainable recycling of plastic waste into new products, cap production, lower consumption, and prevent waste generation.


Asunto(s)
Plásticos , Administración de Residuos , Noruega , Embalaje de Productos , Reciclaje , Contaminación Ambiental
2.
Biosens Bioelectron ; 179: 113043, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33609951

RESUMEN

In this work, the 3ω hot-wire concept is explored as a prospective biosensing platform with a single sensing element that can detect analytes based on a change in the thermal interface conductance. A uniform receptor layer such as single-stranded DNA is immobilized on a thin aluminium wire, which serves not only as an immobilization platform but also as a heating element and temperature sensor together. The wire is heated periodically with an alternating current (angular frequency ω) and the third harmonic (frequency 3ω) of the voltage across the wire renders the efficiency of heat transfer from the wire to the surrounding medium. The amplitude of the 3ω voltage depends sensitively on the composition and conformation of the biofunctional interface layer. We illustrate this with a model system that includes blank aluminium wires, wires with silanes bound covalently to the native surface oxide, and with single-, respectively double-stranded DNA tethered to the silanes. The difference in heat-transfer due to these coatings is significant and measurable not only in a liquid but also in air. Based on this proof-of-concept, various applications come in sight such as mutation analysis and analyte detection with aptamers or molecularly-imprinted polymers as receptors. Wire materials other than aluminium are possible as well and the concept is suitable for miniaturization and parallelization.


Asunto(s)
Técnicas Biosensibles , ADN de Cadena Simple , Calor , Miniaturización , Estudios Prospectivos
3.
ACS Sens ; 6(1): 100-110, 2021 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-33337133

RESUMEN

In this article, we report on the development of a catheter-based, biomimetic sensor as a step toward a minimally invasive diagnostic instrument in the context of functional bowel disorders. Histamine is a key mediator in allergic and inflammatory processes in the small intestines; however, it is a challenge to determine histamine levels at the duodenal mucosa, and classical bioreceptors are unsuitable for use in the digestive medium of bowel fluid. Therefore, we have developed molecularly imprinted polypyrrole coatings for impedimetric sensing electrodes, which enable the quantification of histamine in nondiluted, human bowel fluid in a broad concentration range from 25 nM to 1 µM. The electrodes show negligible cross-sensitivity to histidine as a competitor molecule and, for comparison, we also evaluated the response of nonimprinted and taurine-imprinted polypyrrole to histamine. Furthermore, using equivalent-circuit modeling, we found that the molecular recognition of histamine by polypyrrole primarily increases the resistive component of the electrode-liquid interface while capacitive effects are negligible. The sensor, integrated into a catheter, measures differentially to correct for nonspecific adsorption effects in the complex matrix of bowel fluids, and a single triggering frequency is sufficient to determine histamine concentrations. Together, these features are beneficial for real-time diagnostic tests.


Asunto(s)
Impresión Molecular , Polímeros , Catéteres , Histamina , Humanos , Pirroles
4.
Resour Conserv Recycl ; 157: 104772, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32494109

RESUMEN

Currently, in the European Union (EU), e-waste chain performance is assessed by technical indicators that aim to ensure system compliance with collection and recovery targets set by the WEEE Directive. This study proposes indicators to improve WEEE flow monitoring beyond the current overall weight-based approach, including complementary flows and treatment performance. A case study focused on the screen category in France is presented. In 2017, the collection rate of cathode-ray tube screens (CRT) was 68%, while for flat panel display (FPD) generated only 14% was collected. CRT screens have less precious and critical materials than FDP. Thus, elements like cobalt and gold highly concentrated in FPD, have a collection rate two to four times lower than elements such as copper (37%) which represents a high proportion in CRTs. Recycling is the main treatment in France. Nevertheless, the recycling rate per element varies significantly due to the low collection, and also the lack of technology and/or secondary raw materials market. The elements with higher recycling rates are base metals such as copper (28%), followed by precious metals like silver (23%), and gold (13%). Except for palladium, the recycling rate of the critical raw materials targeted in the study ranged from 6% (cobalt) to 0% (e.g. neodymium and indium). The results stress the need for indicators to support the development of WEEE chain from waste management to secondary (critical) raw materials suppliers.

5.
Biosens Bioelectron ; 158: 112152, 2020 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-32275205

RESUMEN

In this work, we report on the development of a catheter-based sensor designed for measuring the concentration of histamine in the human duodenum. Certain gut disorders, such as the irritable bowel syndrome (IBS), are associated with elevated levels of intestinal histamine due to chronic immune activation. As it is still impossible to determine histamine concentrations in vivo, a nasointestinal catheter with histamine-sensing capabilities has the potential to become a valuable diagnostic instrument. Regarding the sensing principle, we selected impedance spectroscopy using voltages that are compatible with intra-body applications with molecularly imprinted polymers (MIPs) as recognition elements. MIPs are synthetic receptors that offer the advantages of robustness, high specificity and selectivity for histamine as a target. In this specific case, the MIPs were synthesized from acryclic acid monomers, which guarantees a uniform binding capacity within the pH range of intestinal fluid. We have validated the catheter sensor on human intestinal liquids spiked with histamine in a testing setup that mimics the environment inside the duodenum. The dose-response curves show an analytical range between 5 and 200 nM of histamine, corresponding to physiologically normal conditions while higher concentrations correlate with disease. The key output signal of the sensor is the resistive component of the MIP-functionalized titanium electrodes as derived from the equivalent-circuit modelling of full-range impedance spectra. Future applications could be catheters tailored to cardiovascular, urological, gastrointestinal, and neurovascular applications. This, in combination with the versatility of the MIPs, will make this sensor platform a versatile diagnostic tool.


Asunto(s)
Técnicas Biosensibles , Catéteres , Impedancia Eléctrica , Histamina/metabolismo , Síndrome del Colon Irritable/diagnóstico , Síndrome del Colon Irritable/metabolismo , Biomimética/instrumentación , Biomimética/métodos , Espectroscopía Dieléctrica , Electrodos , Diseño de Equipo , Humanos , Concentración de Iones de Hidrógeno , Síndrome del Colon Irritable/etiología , Polímeros Impresos Molecularmente
6.
Biosens Bioelectron ; 136: 97-105, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31048213

RESUMEN

We report on a novel biomimetic sensor that allows sensitive and specific detection of Escherichia coli (E. coli) bacteria in a broad concentration range from 102 up to 106 CFU/mL in both buffer fluids and relevant food samples (i.e. apple juice). The receptors are surface-imprinted polyurethane layers deposited on stainless-steel chips. Regarding the transducer principle, the sensor measures the increase in thermal resistance between the chip and the liquid due to the presence of bacteria captured on the receptor surface. The low noise level that enables the low detection limit originates from a planar meander element that serves as both a heater and a temperature sensor. Furthermore, the experiments show that the presence of bacteria in a liquid enhances the thermal conductivity of the liquid itself. Reference tests with a set of other representative species of Enterobacteriaceae, closely related to E. coli, indicate a very low cross-sensitivity with a sensor response at or below the noise level.


Asunto(s)
Técnicas Bacteriológicas/métodos , Técnicas Biosensibles/métodos , Escherichia coli/aislamiento & purificación , Microbiología de Alimentos , Biomimética
7.
ERJ Open Res ; 5(2)2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30949491

RESUMEN

Peak oxygen uptake (V'O2peak) is recognised as the best expression of aerobic fitness. Therefore, it is essential that V'O2peak reference values are accurate for interpreting a cardiopulmonary exercise test (CPET). These values are country specific and influenced by underlying biological ageing processes. They are normally stratified per paediatric and adult population, resulting in a discontinuity at the transition point between prediction equations. There are currently no age-related reference values available for the lifespan of individuals in the Dutch population. The aim of this study is to determine the best-fitting regression model for V'O2peak in the healthy Dutch paediatric and adult populations in relation to age. In this retrospective study, CPET cycle ergometry results of 4477 subjects without reported somatic diseases were included (907 females, age 7.9-65.0 years). Generalised additive models were employed to determine the best-fitting regression model. Cross-validation was performed against an independent dataset consisting of 3518 subjects (170 females, age 6.8-59.0 years). An additive model was the best fitting with the largest predictive accuracy in both the primary (adjusted R2=0.57, standard error of the estimate (see)=556.50 mL·min-1) and cross-validation (adjusted R2=0.57, see=473.15 mL·min-1) dataset. This study provides a robust additive regression model for V'O2peak in the Dutch population.

8.
Rev Sci Instrum ; 90(12): 125106, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31893814

RESUMEN

Water plays a key role in the functioning of natural and synthetic molecular systems. Despite several hydration studies, different techniques are employed individually for monitoring different physical features such as kinetics, dynamics, and absorption. This study describes a compact hydration cell that enables simultaneous dielectric relaxation spectroscopy (DRS) and mass loss/uptake measurements in thin organic layers under controlled humidity conditions and in a wide temperature range. This approach enabled us to correlate the physical quantities obtained during the same experiment by complementary techniques. To demonstrate the performance of this device, a 200 nm thick poly(methyl methacrylate) (PMMA) layer was measured at various relative humidity levels (0%-75%), temperatures (25-75 °C), and frequencies (DRS: 0.1 Hz-1 MHz) to study how hydration and dehydration processes affect its molecular dynamics. The results show the capability of this setup to study the changes in the PMMA film regarding the kinetics and molecular dynamics upon variation of the water content.

9.
Nutrients ; 10(6)2018 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-29891757

RESUMEN

Vitamin K was originally discovered as a cofactor required to activate clotting factors and has recently been shown to play a key role in the regulation of soft tissue calcification. This property of vitamin K has led to an increased interest in novel methods for accurate vitamin K detection. Molecularly Imprinted Polymers (MIPs) could offer a solution, as they have been used as synthetic receptors in a large variety of biomimetic sensors for the detection of similar molecules over the past few decades, because of their robust nature and remarkable selectivity. In this article, the authors introduce a novel imprinting approach to create a MIP that is able to selectively rebind vitamin K1. As the native structure of the vitamin does not allow for imprinting, an alternative imprinting strategy was developed, using the synthetic compound menadione (vitamin K3) as a template. Target rebinding was analyzed by means of UV-visible (UV-VIS) spectroscopy and two custom-made thermal readout techniques. This analysis reveals that the MIP-based sensor reacts to an increasing concentration of both menadione and vitamin K1. The Limit of Detection (LoD) for both compounds was established at 700 nM for the Heat Transfer Method (HTM), while the optimized readout approach, Thermal Wave Transport Analysis (TWTA), displayed an increased sensitivity with a LoD of 200 nM. The sensor seems to react to a lesser extent to Vitamin E, the analogue under study. To further demonstrate its potential application in biochemical research, the sensor was used to measure the absorption of vitamin K in blood serum after taking vitamin K supplements. By employing a gradual enrichment strategy, the sensor was able to detect the difference between baseline and peak absorption samples and was able to quantify the vitamin K concentration in good agreement with a validation experiment using High-Performance Liquid Chromatography (HPLC). In this way, the authors provide a first proof of principle for a low-cost, straightforward, and label-free vitamin K sensor.


Asunto(s)
Materiales Biomiméticos , Técnicas Biosensibles , Impresión Molecular/métodos , Polímeros/síntesis química , Vitamina K 1/metabolismo , Sitios de Unión , Biomarcadores/metabolismo , Cromatografía Líquida de Alta Presión , Humanos , Límite de Detección , Ensayo de Materiales , Prueba de Estudio Conceptual , Unión Proteica , Conformación Proteica , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta , Relación Estructura-Actividad , Vitamina K 1/sangre , Vitamina K 1/química , Vitamina K 3/metabolismo
10.
Ann Work Expo Health ; 62(2): 232-242, 2018 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-29293872

RESUMEN

Armed forces typically have personal protective clothing (PPC) in place to offer protection against chemical, biological, radiological and nuclear (CBRN) agents. The regular soldier is equipped with permeable CBRN-PPC. However, depending on the operational task, these PPCs pose too much thermal strain to the wearer, which results in a higher risk of uncompensable heat stress. This study investigates the possibilities of adjustable CBRN-PPC, consisting of different layers that can be worn separately or in combination with each other. This novel concept aims to achieve optimization between protection and thermal strain during operations. Two CBRN-PPC (protective) layers were obtained from two separate manufacturers: (i) a next-to-skin (NTS) and (ii) a low-burden battle dress uniform (protective BDU). In addition to these layers, a standard (non-CBRN protective) BDU (sBDU) was also made available. The effect of combining clothing layers on the levels of protection were investigated with a Man-In-Simulant Test. Finally, a mechanistic numerical model was employed to give insight into the thermal burden of the evaluated CBRN-PPC concepts. Combining layers results in substantially higher protection that is more than the sum of the individual layers. Reducing the airflow on the protective layer closest to the skin seems to play an important role in this, since combining the NTS with the sBDU also resulted in substantially higher protection. As expected, the thermal strain posed by the different clothing layer combinations decreases as the level of protection decreases. This study has shown that the concept of adjustable protection and thermal strain through multiple layers of CBRN-PPC works. Adjustable CBRN-PPC allows for optimization of the CBRN-PPC in relation to the threat level, thermal environment, and tasks at hand in an operational setting.


Asunto(s)
Trastornos de Estrés por Calor/prevención & control , Personal Militar , Exposición Profesional/prevención & control , Ropa de Protección , Adulto , Análisis de Varianza , Diseño de Equipo , Humanos , Masculino , Ensayo de Materiales/métodos , Ropa de Protección/efectos adversos , Ropa de Protección/normas , Adulto Joven
11.
Sensors (Basel) ; 17(12)2017 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-29168733

RESUMEN

Serotonin is an important neurotransmitter that plays a major role in the pathogenesis of a variety of conditions, including psychiatric disorders. The detection of serotonin typically relies on high-performance liquid chromatography (HPLC), an expensive technique that requires sophisticated equipment and trained personnel, and is not suitable for point-of-care applications. In this contribution, we introduce a novel sensor platform that can measure spiked neurotransmitter concentrations in whole blood samples in a fast and low-cost manner by combining synthetic receptors with a thermal readout technique-the heat-transfer method. In addition, the design of a miniaturized version of the sensing platform is presented that aims to bridge the gap between measurements in a laboratory setting and point-of-care measurements. This fully automated and integrated, user-friendly design features a capillary pumping unit that is compatible with point-of-care sampling techniques such as a blood lancet device (sample volume-between 50 µL and 300 µL). Sample pre-treatment is limited to the addition of an anti-coagulant. With this fully integrated setup, it is possible to successfully discriminate serotonin from a competitor neurotransmitter (histamine) in whole blood samples. This is the first demonstration of a point-of-care ready device based on synthetic receptors for the screening of neurotransmitters in complex matrices, illustrating the sensor's potential application in clinical research and diagnosis of e.g., early stage depression.

12.
ACS Sens ; 2(4): 583-589, 2017 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-28480332

RESUMEN

Molecularly imprinted polymers (MIPs), synthetic polymeric receptors, have been combined successfully with thermal transducers for the detection of small molecules in recent years. However, up until now they have been combined with planar electrodes which limits their use for in vivo applications. In this work, a new biosensor platform is developed by roll-coating MIP particles onto thermocouples, functionalized with polylactic acid (PLLA). As a first proof-of-principle, MIPs for the neurotransmitter dopamine were incorporated into PLLA-coated thermocouples. The response of the synthetic receptor layer to an increasing concentration of dopamine in buffer was analyzed using a homemade heat-transfer setup. Binding of the template to the MIP layer blocks the heat transport through the thermocouple, leading to less heat loss to the environment and an overall higher temperature in the measuring chamber. The measured temperature increase is correlated to the neurotransmitter concentration, which enables measurement of dopamine levels in the micromolar regime. To demonstrate the general applicability of the proposed biosensor platform, thermocouples were functionalized with similar MIPs for cortisol and serotonin, indicating a similar response and limit-of-detection. As the platform does not require planar electrodes, it can easily be integrated in, e.g., a catheter. In this way, it is an excellent fit for the current niche in the market of therapeutics and diagnostics. Moreover, the use of a biocompatible and disposable PLLA-layer further illustrates its potential for in vivo diagnostics.

13.
ACS Infect Dis ; 3(5): 388-397, 2017 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-28388095

RESUMEN

This paper introduces a novel bacterial identification assay based on thermal wave analysis through surface-imprinted polymers (SIPs). Aluminum chips are coated with SIPs, serving as synthetic cell receptors that have been combined previously with the heat-transfer method (HTM) for the selective detection of bacteria. In this work, the concept of bacterial identification is extended toward the detection of nine different bacterial species. In addition, a novel sensing approach, thermal wave transport analysis (TWTA), is introduced, which analyzes the propagation of a thermal wave through a functional interface. The results presented here demonstrate that bacterial rebinding to the SIP layer resulted in a measurable phase shift in the propagated wave, which is most pronounced at a frequency of 0.03 Hz. In this way, the sensor is able to selectively distinguish between the different bacterial species used in this study. Furthermore, a dose-response curve was constructed to determine a limit of detection of 1 × 104 CFU mL-1, indicating that TWTA is advantageous over HTM in terms of sensitivity and response time. Additionally, the limit of selectivity of the sensor was tested in a mixed bacterial solution, containing the target species in the presence of a 99-fold excess of competitor species. Finally, a first application for the sensor in terms of infection diagnosis is presented, revealing that the platform is able to detect bacteria in clinically relevant concentrations as low as 3 × 104 CFU mL-1 in spiked urine samples.


Asunto(s)
Materiales Biomiméticos/química , Técnicas Biosensibles/métodos , Bacterias Gramnegativas/aislamiento & purificación , Bacterias Grampositivas/aislamiento & purificación , Poliuretanos/química , Aluminio/química , Técnicas Biosensibles/instrumentación , Calor , Límite de Detección , Impresión Molecular , Receptores Artificiales/química , Urinálisis/métodos
14.
Ann Work Expo Health ; 61(2): 248-259, 2017 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28395350

RESUMEN

A major concern for responders to hazardous materials (HazMat) incidents is the heat strain that is caused by fully encapsulated impermeable (NFPA 1991) suits. In a research project, funded by the US Department of Defense, the thermal strain experienced when wearing these suits was studied. Forty human subjects between the ages of 25 and 50 participated in a protocol approved by the local ethical committee. Six different fully encapsulated impermeable HazMat suits were evaluated in three climates: moderate (24°C, 50% RH, 20°C WBGT), warm-wet (32°C, 60% RH, 30°C WBGT), and hot-dry (45°C, 20% RH, 37°C WBGT, 200 W m-2 radiant load) and at three walking speeds: 2.5, 4, and 5.5 km h-1. The medium speed, 4 km h-1, was tested in all three climates and the other two walking speeds were only tested in the moderate climate. Prior to the test a submaximal exercise test in normal clothing was performed to determine a relationship between heart rate and oxygen consumption (pretest). In total, 163 exposures were measured. Tolerance time ranged from as low as 20 min in the hot-dry condition to 60 min (the maximum) in the moderate climate, especially common at the lowest walking speed. Between the six difference suits limited differences were found, a two-layered aluminized suit exhibited significant shorter tolerance times in the moderate climate, but no other major significant differences were found for the other climates or workloads. An important characteristic of the overall dataset is the large variability between the subjects. Although the average responses seem suitable to be predicted, the variability in the warmer strain conditions ranged from 20 min up to 60 min. The work load in these encapsulated impermeable suits was also significantly higher than working in normal clothing and higher than predicted by the Pandolf equation. Heart rate showed a very strong correlation to body core temperature and was in many cases the limiting factor. Setting the heart rate maximum at 80% of predicted individual maximum (age based) would have prevented 95% of the cases with excessive heat strain. Monitoring of heart rate under operational conditions would further allow individually optimize working times and help in preventing exertional heat stroke.


Asunto(s)
Clima , Calor/efectos adversos , Esfuerzo Físico/fisiología , Ropa de Protección/efectos adversos , Carga de Trabajo , Temperatura Corporal/fisiología , Prueba de Esfuerzo , Frecuencia Cardíaca/fisiología , Humanos , Consumo de Oxígeno
15.
ACS Appl Mater Interfaces ; 7(19): 10316-23, 2015 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-25916249

RESUMEN

Aptamers are an emerging class of molecules that, because of the development of the systematic evolution of ligands by exponential enrichment (SELEX) process, can recognize virtually every target ranging from ions, to proteins, and even whole cells. Although there are many techniques capable of detecting template molecules with aptamer-based systems with high specificity and selectivity, they lack the possibility of integrating them into a compact and portable biosensor setup. Therefore, we will present the heat-transfer method (HTM) as an interesting alternative because this offers detection in a fast and low-cost manner and has the possibility of performing experiments with a fully integrated device. This concept has been demonstrated for a variety of applications including DNA mutation analysis and screening of cancer cells. To the best our knowledge, this is the first report on HTM-based detection of proteins, in this case specifically with aptamer-type receptors. For proof-of-principle purposes, measurements will be performed with the peanut allergen Ara h 1 and results indicate detection limits in the lower nanomolar regime in buffer liquid. As a first proof-of-application, spiked Ara h 1 solutions will be studied in a food matrix of dissolved peanut butter. Reference experiments with the quartz-crystal microbalance will allow for an estimate of the areal density of aptamer molecules on the sensor-chip surface.


Asunto(s)
Antígenos de Plantas/análisis , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Glicoproteínas/análisis , Proteínas de Plantas/análisis , Análisis por Matrices de Proteínas/instrumentación , Receptores Artificiales/química , Termografía/métodos , Antígenos de Plantas/química , Glicoproteínas/química , Calor , Proteínas de la Membrana , Proteínas de Plantas/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Coloración y Etiquetado
16.
Sensors (Basel) ; 14(6): 11016-30, 2014 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-24955945

RESUMEN

In this work we present the first steps towards a molecularly imprinted polymer (MIP)-based biomimetic sensor array for the detection of small organic molecules via the heat-transfer method (HTM). HTM relies on the change in thermal resistance upon binding of the target molecule to the MIP-type receptor. A flow-through sensor cell was developed, which is segmented into four quadrants with a volume of 2.5 µL each, allowing four measurements to be done simultaneously on a single substrate. Verification measurements were conducted, in which all quadrants received a uniform treatment and all four channels exhibited a similar response. Subsequently, measurements were performed in quadrants, which were functionalized with different MIP particles. Each of these quadrants was exposed to the same buffer solution, spiked with different molecules, according to the MIP under analysis. With the flow cell design we could discriminate between similar small organic molecules and observed no significant cross-selectivity. Therefore, the MIP array sensor platform with HTM as a readout technique, has the potential to become a low-cost analysis tool for bioanalytical applications.


Asunto(s)
Dimetilpolisiloxanos/química , Análisis por Micromatrices/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Impresión Molecular/métodos , Compuestos Orgánicos/análisis , Compuestos Orgánicos/química , Termografía/instrumentación , Biomimética/instrumentación , Transferencia de Energía , Diseño de Equipo , Análisis de Falla de Equipo , Peso Molecular , Conductividad Térmica , Transductores
17.
Waste Manag ; 33(11): 2397-407, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23899476

RESUMEN

Waste electrical and electronic equipment (or e-waste) is one of the fastest growing waste streams, which encompasses a wide and increasing spectrum of products. Accurate estimation of e-waste generation is difficult, mainly due to lack of high quality data referred to market and socio-economic dynamics. This paper addresses how to enhance e-waste estimates by providing techniques to increase data quality. An advanced, flexible and multivariate Input-Output Analysis (IOA) method is proposed. It links all three pillars in IOA (product sales, stock and lifespan profiles) to construct mathematical relationships between various data points. By applying this method, the data consolidation steps can generate more accurate time-series datasets from available data pool. This can consequently increase the reliability of e-waste estimates compared to the approach without data processing. A case study in the Netherlands is used to apply the advanced IOA model. As a result, for the first time ever, complete datasets of all three variables for estimating all types of e-waste have been obtained. The result of this study also demonstrates significant disparity between various estimation models, arising from the use of data under different conditions. It shows the importance of applying multivariate approach and multiple sources to improve data quality for modelling, specifically using appropriate time-varying lifespan parameters. Following the case study, a roadmap with a procedural guideline is provided to enhance e-waste estimation studies.


Asunto(s)
Residuos Electrónicos , Modelos Teóricos , Residuos Electrónicos/estadística & datos numéricos , Análisis Multivariante , Países Bajos , Administración de Residuos
18.
Ann Occup Hyg ; 55(5): 510-8, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21669907

RESUMEN

The goal of the present study was to investigate physiological effects, mainly at the level of the foot, of two sock fabrics with distinct moisture properties. Twelve participants wore two different socks, one on each foot. The following two sock types were used: PP: 99.6% polypropylene and 0.4% elastane and BLEND: 50% Merino wool, 33% polypropylene, and 17% polyamide. The participants walked three times on a treadmill at 5 km h(-1), with no gradient for the first and third phase and a 10% upward inclination for the second walking phase. The microclimate temperature between the boot and foot was measured during walking. Preceding and following the walking phases, additional measurements were carried out at the level of the foot, i.e. skin temperature and skin hydration on three locations and skin friction between the posterior surface of the calcaneus and a glass plate. In addition, the moisture absorption of boots and socks was determined. Differences between the sock fabrics were found for weight gain and microclimate temperature: (i) PP tended to hold less water compared to BLEND, (ii) the boot's microclimate temperature resulted in larger values for BLEND measured at the dorsal surface at the level of the third metatarsal, and (iii) warmer microclimates of the boot were measured for PP compared to BLEND at the distal anterior end of the tibia. The established differences in moisture behavior of both socks did not result in detectable differences in parameters measured on the skin of the foot.


Asunto(s)
Vesícula/etiología , Pie/fisiología , Traumatismos Ocupacionales/etiología , Ropa de Protección/efectos adversos , Caminata/fisiología , Adulto , Alquenos/efectos adversos , Animales , Fricción , Humanos , Masculino , Microclima , Personal Militar , Nylons/efectos adversos , Temperatura Cutánea/fisiología , Lana/efectos adversos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...