Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Hand Surg Rehabil ; 42(5): 459-461, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37499796

RESUMEN

Osteoid osteoma is a benign osteoblastic tumor with a low incidence. Due to its uncommon and often confusing clinical presentation, accurate diagnosis is frequently significantly delayed. We report a case of a 56-year old right-handed woman with a history of increasing pain in her right scaphotrapeziotrapezoidal (STT) joint and distal flexor carpi radialis (FCR). Due to its confusing clinical presentation, the diagnosis of a parosteal osteoid osteoma in the scaphoid and a rupture of the FCR, presenting as a Mannerfelt like lesion, was delayed for 1 year. The patient was treated with surgical exploration and excision. At follow-up, the patient recovered with complete resolution of pain and resumed daily life activities after 2 weeks. A high index of suspicion remains the key point in the diagnosis of osteoid osteoma, certainly in cases of unusual clinical presentation and anatomic localization as presented in this case.


Asunto(s)
Neoplasias Óseas , Osteoma Osteoide , Humanos , Femenino , Persona de Mediana Edad , Osteoma Osteoide/complicaciones , Osteoma Osteoide/diagnóstico por imagen , Osteoma Osteoide/cirugía , Muñeca , Rotura , Tendones/patología , Dolor/etiología , Neoplasias Óseas/complicaciones , Neoplasias Óseas/cirugía
2.
Spine Deform ; 11(5): 1137-1143, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37284907

RESUMEN

PURPOSE: Treatment of AIS, a three-dimensional spinal (3D) deformity, is guided by a two-dimensional (2D) evaluation. Novel 3D approaches that address the 2D limitations have not been adopted in AIS care due to their lengthy and complex 3D reconstruction procedures. This study aims to introduce a simple 3D method that translates the 2D key parameters (Stable vertebra (SV), Lenke lumbar modifier, Neutral vertebra (NV)) into 3D and to quantitively compare these 3D corrected parameters to the 2D assessment. METHODS: The key parameters of 79 surgically treated Lenke 1 and 2 patients were measured in 2D by two experienced spine surgeons. Next, these key parameters were measured in 3D by indicating relevant landmarks on biplanar radiographs and using the 'true' 3D CSVL which was perpendicular to the pelvic plane. Differences between the 2D and 3D analysis were examined. RESULTS: A 2D-3D mismatch was identified in 33/79 patients (41.8%) for at least one of the key parameters. More specifically, a 2D-3D mismatch was identified in 35.4% of patients for the Sag SV, 22.5% of patients for the SV and 17.7% of patients for the lumbar modifier. No differences in L4 tilt and NV rotation were found. CONCLUSION: The findings highlight that a 3D evaluation alters the choice of the LIV in Lenke 1 and 2 AIS patients. Although, the true impact of this more precise 3D measurement on preventing poor radiographic outcome needs further investigation, the results are a first step toward establishing a basis for 3D assessments in daily practice.


Asunto(s)
Columna Vertebral , Cirujanos , Humanos , Región Lumbosacra , Pelvis , Rotación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA