Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Thromb Haemost ; 123(7): 700-713, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36423623

RESUMEN

BACKGROUND: Computed tomography (CT) pulmonary angiography has simplified the diagnostic approach to patients with clinically suspected acute pulmonary embolism (PE), but alternative imaging tests are still advocated. We aimed to systematically assess the diagnostic accuracy of ventilation/perfusion (V/Q) and Q single-photon emission CT combined with low-dose CT (SPECT/CT) for PE diagnosis. METHODS: Studies evaluating the diagnostic accuracy of SPECT/CT for the diagnosis of acute PE were systematically searched in MEDLINE and EMBASE databases (up to August 2022). The QUADAS-2 tool was used for risk-of-bias assessment of the primary studies. A bivariate random-effects regression approach was used for summary estimates of both sensitivity and specificity. The PROSPERO registration number is CRD42021276538. RESULTS: Eight studies, for a total of 1,086 patients, were included. The risk of bias of all included studies was high. The weighted mean prevalence of PE was 27.1% at the random-effects model. The SPECT/CT bivariate weighted mean sensitivity was 96% (95% confidence interval [CI]: 93-98%), with a bivariate weighted mean specificity of 95% (95% CI: 90-97%). At subgroup analysis, for V/Q SPECT/CT bivariate weighted mean sensitivity and specificity were 96% (95% CI: 89-98%) and 96% (95% CI: 91-99%), while for Q SPECT/CT they were 96% (95% CI: 92-98%) and 84% (95% CI: 66-93%), respectively. CONCLUSION: V/Q SPECT/CT has high sensitivity and specificity for the diagnosis of acute PE, meanwhile Q SPECT/CT has high sensitivity but limited specificity for the diagnosis of PE. Management studies will conclusively ascertain the actual role of SPECT/CT in the diagnostic workup of patients with suspected acute PE.


Asunto(s)
Embolia Pulmonar , Tomografía Computarizada de Emisión de Fotón Único , Humanos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Pulmón , Sensibilidad y Especificidad , Enfermedad Aguda
2.
Prog Brain Res ; 270(1): 105-121, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35396023

RESUMEN

Transcranial magnetic stimulation (TMS) has been widely applied for evaluation of the cortical eloquence through creation of the temporary "virtual lesion" allowing assessment of the evaluated function within the targeted region, which may be also employed for management of mental symptoms or modification of the abnormal behavior. It is believed that this non-invasive neuromodulation modality has a double impact on neurons-primary modulation of electrical activity and stimulation of neuroplasticity; the latter can be facilitated by repeated administration of TMS during multiple sessions over sufficiently long periods of time to induce consolidation of treatment effects through their recall at psychological, physiological, and cellular levels. These principles were employed in our data-driven, tailored strategy based on the modifications of TMS protocol and its adaptation to newly appearing changes of the clinical situation along with administration of prolonged and/or repeated courses of therapeutic stimulation, which showed high efficacy resulting in complete relief of depressive symptoms or substance use in 75% of treated patients at 1-year follow-up. Such results justify application of repetitive TMS for management of psychiatric disorders and warrant additional evaluation of its efficacy in further clinical studies.


Asunto(s)
Conducta Adictiva , Trastornos Relacionados con Sustancias , Depresión , Humanos , Trastornos Relacionados con Sustancias/etiología , Estimulación Magnética Transcraneal/métodos
3.
J Nucl Med ; 62(8): 1171-1176, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34016729

RESUMEN

A 40-y-old woman with severe acute respiratory syndrome coronavirus 2 infection developed neurologic manifestations (confusion, agitation, seizures, dyskinesias, and parkinsonism) a few weeks after the onset of severe acute respiratory syndrome. MRI and cerebrospinal fluid analyses were unremarkable, but 18F-FDG PET/CT showed limbic and extralimbic hypermetabolism. A full recovery, alongside 18F-FDG normalization in previously hypermetabolic areas, was observed after intravenous immunoglobulin administration.


Asunto(s)
Encefalopatías/etiología , COVID-19/complicaciones , SARS-CoV-2 , Adulto , Encéfalo/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Humanos
4.
Eur J Nucl Med Mol Imaging ; 48(9): 2871-2882, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33560453

RESUMEN

PURPOSE: To assess the presence and pattern of incidental interstitial lung alterations suspicious of COVID-19 on fluorine-18-fluorodeoxyglucose positron emission tomography (PET)/computed tomography (CT) ([18F]FDG PET/CT) in asymptomatic oncological patients during the period of active COVID-19 in a country with high prevalence of the virus. METHODS: This is a multi-center retrospective observational study involving 59 Italian centers. We retrospectively reviewed the prevalence of interstitial pneumonia detected during the COVID period (between March 16 and 27, 2020) and compared to a pre-COVID period (January-February 2020) and a control time (in 2019). The diagnosis of interstitial pneumonia was done considering lung alterations of CT of PET. RESULTS: Overall, [18F]FDG PET/CT was performed on 4008 patients in the COVID period, 19,267 in the pre-COVID period, and 5513 in the control period. The rate of interstitial pneumonia suspicious for COVID-19 was significantly higher during the COVID period (7.1%) compared with that found in the pre-COVID (5.35%) and control periods (5.15%) (p < 0.001). Instead, no significant difference among pre-COVID and control periods was present. The prevalence of interstitial pneumonia detected at PET/CT was directly associated with geographic virus diffusion, with the higher rate in Northern Italy. Among 284 interstitial pneumonia detected during COVID period, 169 (59%) were FDG-avid (average SUVmax of 4.1). CONCLUSIONS: A significant increase of interstitial pneumonia incidentally detected with [18F]FDG PET/CT has been demonstrated during the COVID-19 pandemic. A majority of interstitial pneumonia were FDG-avid. Our results underlined the importance of paying attention to incidental CT findings of pneumonia detected at PET/CT, and these reports might help to recognize early COVID-19 cases guiding the subsequent management.


Asunto(s)
COVID-19 , Enfermedades Pulmonares Intersticiales , Fluorodesoxiglucosa F18 , Humanos , Italia , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/epidemiología , Pandemias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Prevalencia , Estudios Retrospectivos , SARS-CoV-2
5.
Ann Neurol ; 80(3): 368-78, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27398636

RESUMEN

OBJECTIVE: To compare the diagnostic value of striatal (123) I-2ß-carbomethoxy-3ß-(4-iodophenyl)-N-(3-fluoropropyl) nortropane ((123) I-FP-CIT) single photon emission computed tomography (SPECT) and (123) I-metaiodobenzylguanidine ((123) I-MIBG) myocardial scintigraphy in differentiating dementia with Lewy bodies (DLB) from other dementia types. METHODS: This prospective longitudinal study included 30 patients with a clinical diagnosis of DLB and 29 patients with non-DLB dementia (Alzheimer disease, n = 16; behavioral variant frontotemporal dementia, n = 13). All patients underwent (123) I-FP-CIT SPECT and (123) I-MIBG myocardial scintigraphy within a few weeks of clinical diagnosis. All diagnoses at each center were agreed upon by the local clinician and an independent expert, both unaware of imaging data, and re-evaluated after 12 months. Each image was visually classified as either normal or abnormal by 3 independent nuclear physicians blinded to patients' clinical data. RESULTS: Overall, sensitivity and specificity to DLB were respectively 93% and 100% for (123) I-MIBG myocardial scintigraphy, and 90% and 76% for (123) I-FP-CIT SPECT. Lower specificity of striatal compared to myocardial imaging was due to decreased (123) I-FP-CIT uptake in 7 non-DLB subjects (3 with concomitant parkinsonism) who had normal (123) I-MIBG myocardial uptake. Notably, in our non-DLB group, myocardial imaging gave no false-positive readings even in those subjects (n = 7) with concurrent medical illnesses (diabetes and/or heart disease) supposed to potentially interfere with (123) I-MIBG uptake. INTERPRETATION: (123) I-FP-CIT SPECT and (123) I-MIBG myocardial scintigraphy have similar sensitivity for detecting DLB, but the latter appears to be more specific for excluding non-DLB dementias, especially when parkinsonism is the only "core feature" exhibited by the patient. Our data also indicate that the potential confounding effects of diabetes and heart disease on (123) I-MIBG myocardial scintigraphy results might have been overestimated. Ann Neurol 2016;80:368-378.


Asunto(s)
3-Yodobencilguanidina , Enfermedad de Alzheimer/diagnóstico por imagen , Cuerpo Estriado/diagnóstico por imagen , Demencia Frontotemporal/diagnóstico por imagen , Enfermedad por Cuerpos de Lewy/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Radiofármacos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tropanos , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Estudios Prospectivos , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...