Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neurointerv Surg ; 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39122254

RESUMEN

BACKGROUND: Sealing of the aneurysm neck with a Woven EndoBridge (WEB) device is recommended for disrupting the blood flow inside the aneurysm. This study investigates the relationship between WEB neck apposition and aneurysm occlusion rates. METHODS: Aneurysms treated with a WEB from March 2017 to May 2022 at a single center were included. WEB neck apposition (poor/good) and WEB protrusion (yes/no) were evaluated on post-detachment high resolution cone beam CT images. Angiographic occlusion was assessed with the Bicêtre Occlusion Scale score (BOSS). Univariate and multivariable analysis tested the association between neck apposition and occlusion rates. RESULTS: The study included 159 aneurysms in 141 patients (mean age 55.8±11.2 years; 64.2% women). Good neck apposition and protrusion were noted in 123 (77.4%) and 30 (18.9%) cases, respectively. Inter-rater agreements were good for neck apposition (κ=0.75) and protrusion (κ=0.78). Complete and adequate occlusion was achieved in 104 (65%) and 130 (82%) cases, respectively (median follow-up 18 months). Good neck apposition was a strong independent predictor for both adequate (adjusted OR (aOR)=5.9, 95% CI 2.4 to 14.9; P<0.001) and complete occlusion (aOR=7.1, 95% CI 3.0 to 18.1; P<0.001). Protrusion was more frequent in the adequate occlusion group versus the aneurysm recurrence group without reaching statistical significance (P=0.06), but was associated with more thromboembolic complications (9/30 (30%) vs 12/129 (9%); P<0.01). WEB shape modification was significantly greater in poor apposition cases (P=0.03). CONCLUSIONS: Achieving good neck apposition of the WEB strongly predicts aneurysm occlusion during follow-up. WEB protrusion should be minimized due to the increase in thromboembolic risk with limited impact on aneurysm occlusion.

2.
J Neurointerv Surg ; 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38991733

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) device is designed to treat wide-necked bifurcation aneurysms. The WEB 17 is the latest iteration and can be delivered through a 0.017″ microcatheter. The CLEVER study demonstrated that WEB 17 is safe and effective for providing protection against bleeding or rebleeding at 1 month and 1 year. OBJECTIVE: To evaluate angiographic stability at 1 year. METHODS: The CLEVER study was a prospective multicenter study conducted in 17 European centers, involved 163 subjects, comprising 60 ruptured and 103 unruptured aneurysms. Independent assessment of 1-year follow-up imaging was incorporated into the study design. RESULTS: Aneurysm diameters ranged from 2.0 to 9.2 mm, with 95.7% being broad-based (dome-to-neck ratio <2). Follow-up imaging at 1 year was completed for 146 out of 163 subjects (89.6%) and evaluated by an independent core laboratory. The primary efficacy endpoint of adequate occlusion without re-treatment at 1 year was achieved for 120 (82.2%) of all subjects. At 1 year, the adequate occlusion rate was 86.5% for ruptured aneurysms (73.1% complete occlusion) and 82.4% for unruptured aneurysms (57.1% complete occlusion). The overall re-treatment rate at 1 year was 2.6% (4/152), with 3.1% (3/97) for unruptured aneurysms and 1.8% (1/55) for ruptured aneurysms CONCLUSION: Delivery of the WEB 17 via 0.017 inch catheters represents a significant evolution of the WEB design. The results of CLEVER presented here demonstrate that it maintains the same efficacy as previous generations of WEB.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38991770

RESUMEN

BACKGROUND AND PURPOSE: A single aspiration maneuver using a large volume syringe is a common and effective technique for aspiration thrombectomy. Multiple aspiration cycles using large aspiration syringes has been proposed as a means to improve efficacy over single aspiration. In this study, we sought to investigate the efficacy of a "triple aspiration technique" where a large volume syringe is cycled three times prior to catheter retraction during aspiration thrombectomy. MATERIALS AND METHODS: A 3D-printed adult vasculature was used as a benchtop thrombectomy platform. Fibrin-rich and red blood cell-rich clots were prepared in centrifuge tubes using human plasma, red blood cells, and calcium chloride. Next, clots were placed in the carotid terminus of the model, and the performances of three different aspiration techniques-triple syringe, single syringe, and continuous pump aspiration-were compared in a randomized manner (1:1:1). Outcomes of interest included first-pass efficacy (FPE), complete clot removal (final mTICI 2c/3), the number of thrombectomy attempts to achieve mTICI 2c/3, vacuum pressure, and distal embolization. The distal emboli were detected using a 70-micron cell strainer placed at the outflow of the model and quantified using an image processing algorithm. The vacuum pressures were measured using a pressure transducer (Honeywell, NC, USA). RESULTS: A total of 102 replicates were performed, 34 for each technique. The triple aspiration technique provided a significantly higher rate of FPE than the syringe and pump aspiration techniques (67.6% vs. 41.1%, p= 0.02). Additionally, the triple aspiration technique achieved complete clot removal with a significantly lower number of thrombectomy attempts compared to single syringe aspiration (1.2 ± 0.5 vs. 1.8 ± 0.8, p=0.005). The triple aspiration technique generated significantly higher vacuum pressure than both the single syringe and vacuum pump aspiration (28.3 ± 0.2 vs. 27.2 ± 0.3 (p= 0.002) and 26.2 ± 0.4 (p=0.001), respectively). The differences in complete clot removal and distal embolization parameters were not statistically significantly different across the groups. CONCLUSIONS: Our findings suggest that the triple aspiration technique can improve FPE rates and vacuum pressure in aspiration thrombectomy. Further studies are needed to examine the safety and efficacy of triple aspiration in the clinical setting. ABBREVIATIONS: AcommA = anterior communicating artery; FPE = first pass efficacy; ICA = internal carotid artery; MCA = middle cerebral artery; MT = mechanical thrombectomy; mTICI = modified thrombolysis in cerebral infarction scale; PcommA = posterior communicating artery.

4.
J Neurointerv Surg ; 2024 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-38830670

RESUMEN

BACKGROUND: Multiple studies and meta-analyses have described the technical and clinical outcomes in large cohorts of aneurysm patients treated with flow diverters (FDs). Variations in evaluation methodology complicate making comparisons among studies, hinder understanding of the device behavior, and pose an obstacle in the assessment of further advances in FD therapy. METHODS: A multidisciplinary panel of neurointerventionalists, imaging experts, and neuroradiologists convened with the goal of establishing consensus recommendations for the standardization of image analyses in FD studies. RESULTS: A standardized methodology is proposed for evaluating and reporting radiological outcomes of FD treatment of intracranial aneurysms. The recommendations include general imaging considerations for clinical studies and evaluations of longitudinal changes, such as neointimal lining and stenosis. They cover standards for classification of aneurysm location, morphology, measurements, as well as the assessment of aneurysm occlusion, wall apposition, and neck coverage. These reporting standards further define four specific braid deformation patterns: foreshortening, fish-mouthing, braid bump deformation, and braid collapse, collectively termed 'F2B2'. CONCLUSIONS: When widely applied, standardization of methods of measuring and reporting outcomes will help to harmonize the assessment of treatment outcomes in clinical studies, help facilitate communication of results among specialists, and help enable research and development to focus on specific aspects of FD techniques and technology.

5.
J Neurointerv Surg ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38862208

RESUMEN

The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field.neurintsurg;jnis-2024-021912v1/V1F1V1Video 1Surgical procedure of creating elastase-induced aneurysms in rabbits.

6.
J Neuroradiol ; 51(5): 101207, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838915

RESUMEN

Intradural spinal cord arteriovenous shunts are challenging vascular lesions with poor prognosis if left untreated. Therapeutic options include endovascular treatment, microsurgery or a combined approach. Surgical approaches are more complex if the lesions are located anteriorly and supplied by the anterior spinal artery (ASA). ASA can also vascularize shunts located on the posterior surface of the spinal cord either by transmedullary arteries, pial circumferential arteries or, if affecting the lower portions of the cord, by the anastomotic channels of the basket. Each of these vessels can be used for endovascular navigation to reach the shunts with good results if appropriate anatomical rules are followed. We describe here some technical considerations based on the anatomical analysis for the embolization of posterior spinal cord arteriovenous shunts vascularized by the anterior spinal artery.

7.
J Neurointerv Surg ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914459

RESUMEN

BACKGROUND: Flow diverting stents (FDS) have transformed the treatment of intracranial aneurysms; however, their metallic structure associated with their intra-luminal positioning hamper angiographic and clinical outcomes. Therefore, there is a need to develop FDS with optimized surfaces that reduce thrombogenicity while promoting the healing process and endothelialization. METHODS: P8RI, a peptide mimicking the CD31 protein, was previously developed and grafted onto Silk Vista (SV) FDS. P8RI-SV and bare-SV were used in vitro in a blood loop model to test their hemocompatibility using human whole blood and in vivo using the rabbit elastase model for optical coherence tomography (OCT) comparisons of neointimal formation at day 5 and day 28. RESULTS: After blood loop incubation, P8RI-SV showed significant reduction in fibrin binding (p=0.004) and platelet adhesion (p=0.041) compared with bare-SV. Similarly, derivative markers measured in blood, thromboxane B2 (platelet activation) and Thrombin-Antithrombin III complexes (coagulation activation), were also significantly reduced in the P8RI-SV group (both p=0.002). In vivo, complete or near-complete occlusion was reached in all aneurysms (n=6) at day 28. Excellent rate of stent-coverage ratio was obtained at day 5 (89.3% (79.1%-98.7%)) comparable to the observation at day 28 (91.8% (79.1%-100%); p=0.44). These rates were significantly higher compared with bare-SV at day 5 (77.8% (58.3%-86.8%); p<0.001) and at day 28 (67.7% (52.6%-88.9%); p<0.0001). CONCLUSION: In vitro results confirm enhanced hemocompatibility with a significant anti-thrombotic effect of the P8RI-SV. In vivo results provide evidence of rapid neo-intimal growth reaching near-complete tissue healing as early as day 5 in a rabbit model.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38575320

RESUMEN

BACKGROUND: The effective treatment for patients with acute ischemic stroke (AIS) with cervical internal carotid pseudo-occlusion (cICA-PO) requires comprehensive research on the safety and outcomes of endovascular thrombectomy (EVT). However, there are limited data available, highlighting the need for further research to ensure better treatment strategies and improve the quality of care for these patients. PURPOSE: This study aims to assess the management and outcomes in this population group compared with patients with true carotid occlusion. DATA SOURCES: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, a comprehensive systematic review was conducted by using PubMed, Embase, Web of Science, and Scopus from database inception to November 2023. STUDY SELECTION: The size of the included studies ranged from 16 patients to 146 patients. Through the 4 full-text articles, a total of 259 patients were collected. We compared outcomes between patients with cICA-PO compared with patients with true carotid occlusions undergoing EVT due to AIS. We excluded studies with patients with carotid pseudo-occlusion without stroke, review articles, duplicate studies, overlapped data that included the same patients presented in another included study, case reports, case series with fewer than 5 patients, and meeting abstracts that did not contain the outcomes of interest. We did not pose any limitations regarding sample size or patient characteristics. DATA ANALYSIS: We utilized the R statistical software (V.4.3.1; R package meta) to conduct the analysis of all the data obtained. We calculated the OR for binary variables, and the corresponding 95% CI. To synthesize the data, random-effect models, as well as forest plots were generated to visually represent the synthesis of the data. Additionally, we assessed heterogeneity by using Cochran Q and I 2 tests. A P value < .05 for the Q statistic or I 2 more than 50% suggests notable heterogeneity. Based on a small number of studies (<10), the assessment of publication bias could not be reliably performed. DATA SYNTHESIS: This meta-analysis encompassed data from 4 studies. Patients with cICA-PO and AIS who underwent EVT (n = 135) exhibited lower rates of functional independence (OR = 0.35; 95% CI, 0.20-0.61; P < .001) compared with patients with true occlusions (n = 103), as well as successful recanalization rates (OR = 0.39; 95% CI, 0.20-0.74; P = .004). In addition, the cICA-PO group experienced higher mortality and symptomatic intracranial hemorrhage (sICH) compared with the group with true carotid occlusions (OR = 2.62; 95% CI, 0.21-7.24; and OR = 2.23; 95% CI, 1.00-4.95; P = .049, respectively). LIMITATIONS: Individual patient data were not available. Studies were a retrospective design and some of the studies had small sample sizes. The included studies in our meta-analysis did not exclude patients with tandem occlusions that might influence the results of the comparison. CONCLUSIONS: Compared with patients with true carotid occlusion, the cICA-PO group with AIS undergoing EVT presented poor outcomes with lower functional independence and successful recanalization, as well as higher sICH and mortality rates.

10.
J Neurointerv Surg ; 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38538055

RESUMEN

BACKGROUND: Retrospective studies suggest the superiority of first-line contact aspiration (CA) thrombectomy over stent-retriever (SR) in basilar artery occlusions (BAO). We aimed to investigate the impact of first-line mechanical thrombectomy per the occlusion level, considering differences in stroke etiology prevalence between proximal and distal BAO. METHODS: A retrospective, multicentric analysis of the Endovascular Treatment in Ischemic Stroke Registry (ETIS) included consecutive BAO patients treated from January 2016 to May 2022. Patients were categorized into SR (±aspiration) and CA alone groups. Occlusion levels were determined through digital subtraction angiography. Favorable clinical outcome was defined as 90-day modified Rankin Scale (mRS) 0-3. RESULTS: A total of 380 patients were analyzed (251 CA alone, 129 SR±aspiration). Globally, first-line SR showed lower recanalization rates (89.1% vs 94.8%, OR=0.29, 95% CI 0.16 to 0.53; p<0.001) and worse clinical outcomes (mRS 0-3: 46.0% vs 52.2%, OR=0.62, 95% CI 0.44 to 0.87; p=0.006) compared with CA. In proximal occlusions, SR was significantly associated with poorer clinical outcomes (mRS 0-3: 20.9% vs 37.1%; OR=0.40, 95% CI 0.19 to 0.83; p=0.014) despite similar recanalization rates. Conversely, in distal occlusions there was no difference in clinical outcomes although recanalization rates were higher with CA (modified Thrombolysis in Cerebral Infarction score (mTICI 2b/3): 97.7% vs 91.7%; OR=0.17, 95% CI 0.05 to 0.66; p=0.01). CONCLUSIONS: In our BAO population, CA demonstrated better angiographic outcomes in middle and distal occlusions and better clinical outcomes in proximal occlusions. This translated into better angiographic and clinical results in the global study population. Clinical results were particularly influenced by the negative impact of SR on 90-day mRS, independently of recanalization rates in proximal BAO.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA