RESUMEN
BACKGROUND AND AIM OF THE STUDY: At present, no reports are available regarding the hemodynamic assessment and survival of patients undergoing valve replacement with HP-Biplus prostheses. Hence, the present study was designed to acquire this information. The aim was to assess: (i) any potential hemodynamic differences between the HP-Biplus prosthesis and the 'standard' bileaflet mechanical valves (SJM, ATS, Sorin Bicarbon and CarboMedics); and (ii) the incidence of postoperative complications and long-term mortality. METHODS: The data from 242 patients (139 males, 103 females; mean age 58.4 +/- 14.0 years) who survived mitral or aortic valve surgery with mechanical bileaflet standard prostheses (SJM, ATS, Sorin Bicarbon or CarboMedics), between January 1985 and December 2005, were analyzed retrospectively. Evaluations were conducted consecutively with Doppler echocardiography, and compared with 35 patients (20 males, 15 females; mean age 52.2 +/- 12.8 years) who received an HP-Biplus prosthesis and underwent surgery between January 2000 and December 2005. RESULTS: At seven years after surgery, actuarial survival was 40% for the HP-Biplus prosthesis and 84% for the 'standard' prostheses (p < 0.0001). The HP-Biplus prostheses had a higher rate of reoperations for aortic valves (15.2% versus 1.7%; p < 0.003, OR 10.2), a higher rate of prosthesis dysfunction (62.9% versus 7.8%; p < 0.00001, OR 25), and a higher rate of total events (72% versus 21.8%; p < 0.0001, OR 11). CONCLUSION: The present study was the first to compare long-term results of the HP-Biplus prostheses with those obtained with 'standard' mechanical prostheses. Valve replacement with standard prostheses was shown to carry low morbidity and mortality (21.8%), whereas the HP-Biplus prosthesis showed high morbidity and mortality (92%). The data acquired may be very important when selecting prostheses with better hemodynamic characteristics, and show that the HP-Biplus prosthesis, in the authors' opinion, is not suitable for clinical use.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Válvula Aórtica , Femenino , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Válvula Mitral , Diseño de Prótesis , Resultado del TratamientoRESUMEN
Antiphospholipid syndrome is a well-defined entity that is characterized by spontaneous abortion, thrombocytopenia, and recurrent arterial and venous thromboses. A partially calcified right atrial thrombus mimicking myxoma with recurrent pulmonary embolism has not been previously reported in a patient who also had systemic lupus erythematosus and secondary antiphospholipid syndrome. Herein, we describe the case of a 37-year-old woman with systemic lupus erythematosus and secondary antiphospholipid syndrome who was admitted to the hospital with progressive exertional dyspnea. Ventilation-perfusion scanning showed multiple parenchymal defects in the lungs that portended pulmonary embolism. In addition, the scanning revealed normal regional ventilation. Transthoracic and transesophageal echocardiography showed a right atrial mass that was highly suggestive of myxoma, and the patient subsequently underwent surgery. A histologic examination showed an organized, partially calcified thrombus. Intracardiac thrombus has been rarely reported as a complication of antiphospholipid syndrome. In our patient, the preoperative investigations could not differentiate the partially calcified right atrial thrombus from a myxoma, and the diagnosis was made postoperatively.