Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Colloids Surf B Biointerfaces ; 131: 59-66, 2015 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-25950497

RESUMEN

Over the last decades, surface biocontamination has become a major concern in food industries and medical environments where its outcomes could vary from financial losses to public health issues. Understanding adhesion mechanisms of involved microorganisms is essential to develop new strategies of prevention and control. Adhesion of Pseudomonas aeruginosa, a nosocomial pathogenic bacterium, relies on several bacterial features, among which are bacterial appendages such as flagella and type IV pili. Here, we examine the role of P. aeruginosa PAO1 flagella and type IV pili in the adhesion to abiotic surfaces with various hydrophobicities. Adhesion kinetics showed, that after 60min, flagella increased the adhesion of the strain to surfaces with high hydrophobicity while no effect was observed on hydrophilic surfaces. Flagella of adherent bacteria exhibited specific and conserved pattern on the surfaces that suggested a higher affinity of flagella for hydrophobic surfaces. Based on these results and on previous studies in the literature, we proposed a model of flagella-mediated adhesion onto hydrophobic surfaces where these appendages induce the first contact and promote the adhesion of the bacterial body. These findings suggest that anti-bioadhesive surface design should take into consideration the presence of bacterial appendages.


Asunto(s)
Adhesión Bacteriana/fisiología , Proteínas Fimbrias/química , Flagelos/química , Pseudomonas aeruginosa/fisiología , Infección Hospitalaria/microbiología , Proteínas Fimbrias/genética , Flagelos/genética , Flagelos/ultraestructura , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Microscopía Electrónica de Rastreo , Microscopía Electrónica de Transmisión , Mutación , Tereftalatos Polietilenos/química , Infecciones por Pseudomonas/microbiología , Pseudomonas aeruginosa/química , Pseudomonas aeruginosa/genética , Acero Inoxidable/química , Propiedades de Superficie
2.
Macromol Biosci ; 12(10): 1354-63, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22927330

RESUMEN

New nonfouling tubes are developed and their influence on the adhesion of neuroproteins is studied. The biomarkers are considered as single components (recombinant prion and Tau proteins) or in a solution of native and pathological forms. The samples are stored for 24 h at 4 °C in virgin and treated tubes layered with two different nanostructured coatings based on poly(N-isopropylacrylamide) with either a positive or a neutral charge, and the protein adhesion is monitored. The recombinant protein with a high pI is repelled from the nanostructured surface that has a negative ζ potential, whereas the recombinant protein with the lower pI is attracted. Furthermore, in the case of complex solutions, neutral nanostructured surfaces are able to retain all amyloid biomarkers.


Asunto(s)
Acrilamidas/química , Péptidos beta-Amiloides/química , Materiales Biocompatibles Revestidos/química , Fragmentos de Péptidos/química , Polímeros/química , Priones/química , Proteínas tau/química , Resinas Acrílicas , Péptidos beta-Amiloides/líquido cefalorraquídeo , Ensayo de Inmunoadsorción Enzimática , Humanos , Nanoestructuras , Fragmentos de Péptidos/líquido cefalorraquídeo , Espectroscopía de Fotoelectrones , Priones/líquido cefalorraquídeo , Unión Proteica , Proteínas Recombinantes/química , Soluciones , Electricidad Estática , Propiedades de Superficie , Termodinámica , Proteínas tau/líquido cefalorraquídeo
3.
Macromol Biosci ; 12(6): 830-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22508476

RESUMEN

New non-fouling tubes are developed and their influence on the adhesion of neuroproteins is studied. Recombinant prion proteins are considered as a single component representative of hydrophobic proteins. Samples are stored for 24 h at 4 °C in tubes coated with two different coatings: poly(N-isopropylacrylamide) as a hydrophilic surface and a plasma-fluorinated coating as a hydrophobic one. The protein adhesion is monitored by ELISA tests, XPS and confocal microscopy. It appears that the highest recovery of recombinant prion protein in the liquid phase is obtained with the hydrophilic surface while the hydrophobic character of the storage tube induces an important amount of biological loss. However, the recovery is not complete even for tubes coated with poly(N-isopropylacrylamide).


Asunto(s)
Acrilamidas/química , Polímeros/química , Priones/química , Resinas Acrílicas , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Proteínas Recombinantes/química , Propiedades de Superficie
4.
J Alzheimers Dis ; 31(1): 13-20, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22495345

RESUMEN

Tau proteins and amyloid-ß (Aß) peptides are the current recognized cerebrospinal fluid (CSF) biomarkers used as an aid in the diagnosis of Alzheimer's disease (AD). However, there is no consensus on their clinical use due to non-qualified cut-off values, probably related to the observed high pre-analytical and analytical variability. Standardized pre-analytical protocols have therefore been proposed. Importantly, these recommend the use of polypropylene collection/sampling tubes while, to date, no broad comparison of these types of tubes has been conducted. In this study, we first compared, as part of a real clinical workflow, the impact of four different collection tubes on the CSF concentration of Aß peptides (Aß42, Aß40) and total (hTau) and phosphorylated (P-Tau181P) tau proteins measured using routine ELISA kits. We then extended this study to 11 polypropylene tubes used by different clinical laboratories, and investigated their plastic polymer composition using differential scanning calorimetry and Fourier Transformed Infrared spectroscopy. Significant concentration variations linked solely to the use of different types of tubes were observed. This was particularly marked for Aß peptides, with >50% disparity occurring in less than five minutes. Polymer composition analysis revealed that most polypropylene tubes were in fact copolymers with at least polyethylene. There was no clear correlation between tube composition and pre-analytical behavior. Our results show that the use of polypropylene tubes does not guarantee satisfactory pre-analytical behavior. They also point to collection/sampling tubes being a major pre-analytical source of variability that could impact the significance of AD biological diagnosis.


Asunto(s)
Enfermedad de Alzheimer/líquido cefalorraquídeo , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/líquido cefalorraquídeo , Errores Diagnósticos , Proteínas tau/líquido cefalorraquídeo , Ensayo de Inmunoadsorción Enzimática , Análisis de Fourier , Humanos , Fosforilación , Riesgo , Espectrofotometría Infrarroja , Estadísticas no Paramétricas , Factores de Tiempo
6.
J Funct Biomater ; 3(2): 298-312, 2012 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-24955533

RESUMEN

The main objective of this paper was to illustrate the enhancement of the sensitivity of ELISA titration for neurodegenerative proteins by reducing nonspecific adsorptions that could lead to false positives. This goal was obtained thanks to the association of plasma and wet chemistries applied to the inner surface of the titration well. The polypropylene surface was plasma-activated and then, dip-coated with different amphiphilic molecules. These molecules have more or less long hydrocarbon chains and may be charged. The modified surfaces were characterized in terms of hydrophilic-phobic character, surface chemical groups and topography. Finally, the coated wells were tested during the ELISA titration of the specific antibody capture of the α-synuclein protein. The highest sensitivity is obtained with polar (Θ = 35°), negatively charged and smooth inner surface.

7.
J Funct Biomater ; 3(3): 528-43, 2012 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-24955631

RESUMEN

This review describes different strategies of surface elaboration for a better control of biomolecule adsorption. After a brief description of the fundamental interactions between surfaces and biomolecules, various routes of surface elaboration are presented dealing with the attachment of functional groups mostly thanks to plasma techniques, with the grafting to and from methods, and with the adsorption of surfactants. The grafting of stimuli-responsive polymers is also pointed out. Then, the discussion is focused on the protein adsorption phenomena showing how their interactions with solid surfaces are complex. The adsorption mechanism is proved to be dependent on the solid surface physicochemical properties as well as on the surface and conformation properties of the proteins. Different behaviors are also reported for complex multiple protein solutions.

8.
Biosensors (Basel) ; 2(4): 433-47, 2012 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-25586034

RESUMEN

This work illustrates the enhancement of the sensitivity of the ELISA titration for recombinant human and native prion proteins, while reducing other non-specific adsorptions that could increase the background signal and lead to a low sensitivity and false positives. It is achieved thanks to the association of plasma chemistry and coating with different amphiphilic molecules bearing either ionic charges and/or long hydrocarbon chains. The treated support by 3-butenylamine hydrochloride improves the signal detection of recombinant protein, while surface modification with the 3,7-dimethylocta-2,6-dien-1-diamine (geranylamine) enhances the sensitivity of the native protein. Beside the surface chemistry effect, these different results are associated with protein conformation.

9.
J Colloid Interface Sci ; 362(2): 300-10, 2011 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-21784430

RESUMEN

The surface grafting of multi-polymeric materials can be achieved by grafting as components such as polymers poly(N-isopropylacrylamide) and/or surfactant molecules (hexatrimethylammonium bromide, polyoxyethylene sorbitan monolaurate). The chosen grafting techniques, i.e. plasma activation followed by coating, allow a large spectrum of functional groups that can be inserted on the surface controlling the surface properties like adhesion, wettability and biocompatibility. The grafted polypropylene surfaces were characterized by contact angle analyses, XPS and AFM analyses. The influence of He plasma activation, of the coating parameters such as concentrations of the various reactive agents are discussed in terms of hydrophilic character, chemical composition and morphologic surface heterogeneity. The plasma pre-activation was shown inevitable for a permanent polymeric grafting. PNIPAM was grafted alone or with a mixture of the surfactant molecules. Depending on the individual proportion of each component, the grafted surfaces are shown homogeneous or composed of small domains of one component leading to a nano-structuration of the grafted surface.

10.
J Biomater Sci Polym Ed ; 14(10): 1135-53, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14661884

RESUMEN

Aiming to encapsulate pancreatic islets, a biocompatible polycarbonate membrane (Whatman) was treated with plasma argon in order to improve its surface properties. The argon plasma treatment decreased the hydrophobicity of the membrane by fixing polyvinylpyrrolidone (PVP) at the surface. The water angle contact decreased from 47 degrees to 20 degrees after this treatment, while the structure and pore diameter were preserved. The treatment also increased significantly the water permeability from 62 +/- 8 ml/min to 200 +/- 29 ml/min (P < 0.001). ToF-SIMS analyses revealed that the argon plasma treatment of the membrane allowed the installation of an uniform PVP layer at the surface. The concentration equilibrum in glucose was reached after 8 h diffusion for the treated membrane, while it was only 32.4 +/- 8.6% (P < 0.01) for the untreated membrane. The biocompatibility of the polycarbonate membrane was assessed after one month of implantation in rats and proved to be unaffected by the surface treatment. In conclusion, the present study provided sufficient information to establish a relationship between the physicochemical modifications of the PVP-plasma-treated polycarbonate membrane and the improvement in its permeability.


Asunto(s)
Materiales Biocompatibles/química , Membranas Artificiales , Cemento de Policarboxilato/química , Animales , Argón/química , Difusión , Glucosa/farmacocinética , Trasplante de Islotes Pancreáticos/instrumentación , Trasplante de Islotes Pancreáticos/métodos , Masculino , Ensayo de Materiales , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Permeabilidad , Povidona/química , Ratas , Ratas Wistar , Espectrometría de Masa de Ion Secundario/métodos , Espectrometría por Rayos X , Propiedades de Superficie
11.
Biopolymers ; 63(4): 232-8, 2002 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-11807750

RESUMEN

The general properties of hydroxyethylcellulose (HEC) grafted with 3-glycidoxypropyltrimethoxysilane (GPTMS) or 3-glycidoxypropylmethyldiethoxysilane (GPDMS) were studied for potential biomedical applications. The graft involved a Williamson reaction between the free hydroxyl function of HEC and the epoxy function of the two silanes. As the grafted silanes are in ionic form (sodium silanolate), this product remains in gel form at basic pH (>12.3) in aqueous solution. When pH decreases, sodium silanolate is transformed into silanol (2 or 3 silanol functions are carried by silicon, depending on the silane grafted). The silanols interreact, and the gel is transformed into a cross-linking form at room or body temperature. Studies were conducted to optimise this product for specific uses. Steam sterilization was used to compare self-hardening as a function of the silane grafted. Our previous work indicated that HEC grafted with GPTMS has good reactivity, but requires high pH for dissolution, whereas dissolution occurs at lower pH with GPMDS. The rate of silanol condensation for silated HEC was then determined as a function of pH, temperature, type of silane, and the percentage grafted. Condensation rates were ascertained by the viscosity method, and gels were neutralized by different solutions to obtain buffered forms at various pH. The time required to obtain 10(5) mPa x s, with an initial state of 2500 mPa x s, was then calculated. Condensation was catalysed in acid or basic medium at a lower rate at pH 5.5-6.5, and a temperature rise increased the condensation rate, regardless of the pH or silane studied. Silanetriol was more reactive than silanediol. However, as HEC lost considerable viscosity after sterilization, further studies will be conducted to develop new polysaccharides grafted with silane.


Asunto(s)
Celulosa/análogos & derivados , Celulosa/química , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Biopolímeros/química , Celulosa/síntesis química , Concentración de Iones de Hidrógeno , Estructura Molecular , Silanos/química , Esterilización , Viscosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA