Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ultramicroscopy ; 130: 54-62, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23588068

RESUMEN

We report on the implementation and usage of a synchrotron-based time-resolving operation mode in an aberration-corrected, energy-filtered photoemission electron microscope. The setup consists of a new type of sample holder, which enables fast magnetization reversal of the sample by sub-ns pulses of up to 10 mT. Within the sample holder current pulses are generated by a fast avalanche photo diode and transformed into magnetic fields by means of a microstrip line. For more efficient use of the synchrotron time structure, we developed an electrostatic deflection gating mechanism capable of beam blanking within a few nanoseconds. This allows us to operate the setup in the hybrid bunch mode of the storage ring facility, selecting one or several bright singular light pulses which are temporally well-separated from the normal high-intensity multibunch pulse pattern.

2.
J Biol Rhythms ; 27(4): 299-307, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22855574

RESUMEN

The term masking refers to immediate responses to stimuli that override the influence of the circadian timekeeping system on behavior and physiology. Masking by light and darkness plays an important role in shaping an organism's daily pattern of activity. Nocturnal animals generally become more active in response to darkness (positive masking) and less active in response to light (negative masking), and diurnal animals generally have opposite patterns of response. These responses can vary as a function of light intensity as well as time of day. Few studies have directly compared masking in diurnal and nocturnal species, and none have compared rhythms in masking behavior of diurnal and nocturnal species. Here, we assessed masking in nocturnal mice (Mus musculus) and diurnal grass rats (Arvicanthis niloticus). In the first experiment, animals were housed in a 12:12 light-dark (LD) cycle, with dark or light pulses presented at 6 Zeitgeber times (ZTs; with ZT0 = lights on). Light pulses during the dark phase produced negative masking in nocturnal mice but only at ZT14, whereas light pulses resulted in positive masking in diurnal grass rats across the dark phase. In both species, dark pulses had no effect on behavior. In the 2nd experiment, animals were kept in constant darkness or constant light and were presented with light or dark pulses, respectively, at 6 circadian times (CTs). CT0 corresponded to ZT0 of the preceding LD cycle. Rhythms in masking responses to light differed between species; responses were evident at all CTs in grass rats but only at CT14 in mice. Responses to darkness were observed only in mice, in which there was a significant increase in activity at CT 22. In the 3rd experiment, animals were kept on a 3.5:3.5-h LD cycle. Surprisingly, masking was evident only in grass rats. In mice, levels of activity during the light and dark phases of the 7-h cycle did not differ, even though the same animals had responded to discrete photic stimuli in the first 2 experiments. The results of the 3 experiments are discussed in terms of their methodological implications and for the insight they offer into the mechanisms and evolution of diurnality.


Asunto(s)
Conducta Animal/fisiología , Ritmo Circadiano/fisiología , Ratones/fisiología , Murinae/fisiología , Fotoperiodo , Animales , Conducta Animal/efectos de la radiación , Luz , Especificidad de la Especie
3.
Rev Sci Instrum ; 83(6): 063706, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22755633

RESUMEN

In this paper, we present a newly developed gating technique for a time-resolving photoemission microscope. The technique makes use of an electrostatic deflector within the microscope's electron optical system for fast switching between two electron-optical paths, one of which is used for imaging, while the other is blocked by an aperture stop. The system can be operated with a switching time of 20 ns and shows superior dark current rejection. We report on the application of this new gating technique to exploit the time structure in the injection bunch pattern of the synchrotron radiation source BESSY II at Helmholtz-Zentrum Berlin for time-resolved measurements in the picosecond regime.

4.
Nanotechnology ; 22(47): 475304, 2011 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-22057093

RESUMEN

We report on the stepwise generation of layered nanostructures via electron beam induced deposition (EBID) using organometallic precursor molecules in ultra-high vacuum (UHV). In a first step a metallic iron line structure was produced using iron pentacarbonyl; in a second step this nanostructure was then locally capped with a 2-3 nm thin titanium oxide-containing film fabricated from titanium tetraisopropoxide. The chemical composition of the deposited layers was analyzed by spatially resolved Auger electron spectroscopy. With spatially resolved x-ray absorption spectroscopy at the Fe L3 edge, it was demonstrated that the thin capping layer prevents the iron structure from oxidation upon exposure to air.

5.
J Phys Condens Matter ; 21(31): 314008, 2009 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-21828569

RESUMEN

The study of magnetodynamics using stroboscopic time-resolved x-ray photoemission electron microscopy (TR-XPEEM) involves an intrinsic timescale provided by the pulse structure of the synchrotron radiation. In the usual multi-bunch operation mode, the time span between two subsequent light pulses is too short to allow a relaxation of the system into the ground state before the next pump-probe cycle starts. Using a deflection gating mechanism described in this paper we are able to pick the photoemission signal resulting from selected light pulses. Thus, PEEM measurements can be carried out in a flexible timing scheme with longer delays between two light pulses. Using this technique, the magnetodynamics of both Permalloy and iron structures have been investigated. The differences in the dynamic response on a short magnetic field pulse are discussed with respect to the magnetocrystalline anisotropy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...