Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
IEEE Trans Neural Syst Rehabil Eng ; 28(7): 1595-1604, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32340952

RESUMEN

The effectiveness of haptic feedback devices highly depends on the perception of tactile stimuli, which differs across body parts and can be affected by movement. In this study, a novel wearable sensory feedback apparatus made of a pair of pressure-sensitive insoles and a belt equipped with vibrotactile units is presented; the device provides time-discrete vibrations around the waist, synchronized with biomechanically-relevant gait events during walking. Experiments with fifteen healthy volunteers were carried out to investigate users' tactile perception on the waist. Stimuli of different intensities were provided at twelve locations, each time synchronously with one pre-defined gait event (i.e. heel strike, flat foot or toe off), following a pseudo-random stimulation sequence. Reaction time, detection rate and localization accuracy were analyzed as functions of the stimulation level and site and the effect of gait events on perception was investigated. Results revealed that above-threshold stimuli (i.e. vibrations characterized by acceleration amplitudes of 1.92g and 2.13g and frequencies of 100 Hz and 150 Hz, respectively) can be effectively perceived in all the sites and successfully localized when the intertactor spacing is set to 10 cm. Moreover, it was found that perception of time-discrete vibrations was not affected by phase-related gating mechanisms, suggesting that the waist could be considered as a preferred body region for delivering haptic feedback during walking.


Asunto(s)
Percepción del Tiempo , Retroalimentación , Retroalimentación Sensorial , Marcha , Humanos , Caminata
2.
Artículo en Inglés | MEDLINE | ID: mdl-23367055

RESUMEN

We present an automated segmentation method based on the analysis of plantar pressure signals recorded from two synchronized wireless foot insoles. Given the strict limits on computational power and power consumption typical of wearable electronic components, our aim is to investigate the capability of a Hidden Markov Model machine-learning method, to detect gait phases with different levels of complexity in the processing of the wearable pressure sensors signals. Therefore three different datasets are developed: raw voltage values, calibrated sensor signals and a calibrated estimation of total ground reaction force and position of the plantar center of pressure. The method is tested on a pool of 5 healthy subjects, through a leave-one-out cross validation. The results show high classification performances achieved using estimated biomechanical variables, being on average the 96%. Calibrated signals and raw voltage values show higher delays and dispersions in phase transition detection, suggesting a lower reliability for online applications.


Asunto(s)
Pie/fisiología , Marcha/fisiología , Manometría/instrumentación , Monitoreo Ambulatorio/instrumentación , Monitoreo Ambulatorio/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Transductores de Presión , Adulto , Algoritmos , Diagnóstico por Computador/instrumentación , Diagnóstico por Computador/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Manometría/métodos , Presión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Transfus Clin Biol ; 17(2): 41-6, 2010 Apr.
Artículo en Francés | MEDLINE | ID: mdl-20674441

RESUMEN

PURPOSE: Today, haematopoietic stem cell graft from placental blood concerns more than 15 % of allogeneic grafts. An inter-laboratory study of the quality control of defrosted cord blood units has been coordinated by the French society for cell and tissue bioengineering (SFBCT), with the cord blood bank of Bourgogne Franche-Comté and controlled by the French health products safety agency (Afssaps). The aim of this study is to ensure the inter-laboratory reproducibility of the quality controls practised by the banks during defrosting. The cellular outputs were analyzed according to the defrosting techniques, according to the method used in flow cytometry: single-platform (SP) versus double-platform (DP), or the product nature, i.e. in total blood or miniaturized. METHODS: Forty-two units of placental blood (USP), which were out of range were provided for defrosting to 14 participating sites. USP were defrosted and controlled according to the procedures of each bank. Once the USP is defrosted, a part of the product was controlled by the site and the other part by Afssaps. Following controls were carried out: numeration of the total nucleated cells (TNC) and of CD34+ cells (made by a SP method in Afssaps) and functional assay. RESULTS: Concerning TNC, the defrosting sites obtained a cellular output of 94 %+/-28 in day 0 compared with an output of 72 %+/-24 in Afssaps showing a rather good stability of the USP transmitted with an average deviation of 23 %+/-22. The freezing process with or without reduction of volume does not affect this variation. Concerning the numeration of CD34+ cells, the average deviation between the participating sites and Afssaps was 29 %+/-23 compared with 21 %+/-16 for the sites using a SP method against 47 %+/-25 for those using a DP method. The CD34+ outputs are equal to 82 % +/- 60 in day 0 for the participating sites against 52 %+/-20 for Afssaps. For the sites using a DP method, it is stressed that this output is particularly high with a rate of 126 %+/-90 (n=15) whereas it is 62 %+/-20 (n=32) for the sites using a SP method. CONCLUSION: These results underline a good stability of viable CD34+ cells and a greater reliability of the SP methods for the CD34+ cell numeration for these defrosted USP. Lastly, the results of the functional assay regarding the average clonogenicities (equal to 15 %) reinforce the conclusions on the quality of the defrosted products.


Asunto(s)
Conservación de la Sangre/normas , Trasplante de Células Madre de Sangre del Cordón Umbilical/normas , Criopreservación/normas , Sangre Fetal , Control de Calidad , Antígenos CD34/análisis , Recuento de Células Sanguíneas , Conservación de la Sangre/métodos , Núcleo Celular/ultraestructura , Células Clonales/citología , Ensayo de Unidades Formadoras de Colonias , Femenino , Francia , Células Madre Hematopoyéticas/ultraestructura , Humanos , Recién Nacido , Laboratorios , Placenta , Embarazo , Sociedades Médicas/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...