Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 24(5): e65-e85, 2023 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-36881779

RESUMEN

Imaging techniques play a pivotal role in the diagnosis, follow-up, and management of aortic diseases. Multimodality imaging provides complementary and essential information for this evaluation. Echocardiography, computed tomography, cardiovascular magnetic resonance, and nuclear imaging each have strengths and limitations in the assessment of the aorta. This consensus document aims to review the contribution, methodology, and indications of each technique for an adequate management of patients with thoracic aortic diseases. The abdominal aorta will be addressed elsewhere. While this document is exclusively focused on imaging, it is of most importance to highlight that regular imaging follow-up in patients with a diseased aorta is also an opportunity to check the patient's cardiovascular risk factors and particularly blood pressure control.


Asunto(s)
Enfermedades de la Aorta , Cardiología , Enfermedades Vasculares Periféricas , Humanos , Imagen Multimodal , Aorta , Aorta Torácica
2.
Rev Esp Cardiol (Engl Ed) ; 76(3): 183-196, 2023 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36539182

RESUMEN

Magnetic resonance has become a first-line imaging modality in various clinical scenarios. The number of patients with different cardiovascular devices, including cardiac implantable electronic devices, has increased exponentially. Although there have been reports of risks associated with exposure to magnetic resonance in these patients, the clinical evidence now supports the safety of performing these studies under specific conditions and following recommendations to minimize possible risks. This document was written by the Working Group on Cardiac Magnetic Resonance Imaging and Cardiac Computed Tomography of the Spanish Society of Cardiology (SEC-GT CRMTC), the Heart Rhythm Association of the Spanish Society of Cardiology (SEC-Heart Rhythm Association), the Spanish Society of Medical Radiology (SERAM), and the Spanish Society of Cardiothoracic Imaging (SEICAT). The document reviews the clinical evidence available in this field and establishes a series of recommendations so that patients with cardiovascular devices can safely access this diagnostic tool.


Asunto(s)
Cardiología , Desfibriladores Implantables , Cardiopatías , Humanos , Consenso , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
3.
J Am Coll Cardiol ; 79(24): 2415-2427, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35710193

RESUMEN

BACKGROUND: Despite the absence of clinical complications after an acute aortic dissection (AD) with persistent patent false lumen (FL), a high risk for clinical events may persist. OBJECTIVES: The aim of this study was to assess the natural evolution of noncomplicated AD and ascertain whether different FL flow patterns by magnetic resonance imaging (MRI) have independent prognostic value for AD-related events beyond established morphologic parameters. METHODS: One hundred thirty-one consecutive patients, 78 with surgically treated type A dissections and 53 with medically treated type B dissections, were followed up prospectively after acute AD with persistent patent FL in the descending aorta. Maximum aortic diameter, true lumen compression, entry tear, and partial FL thrombosis by computed tomography were assessed. Systolic antegrade true lumen and FL flow volumes and diastolic antegrade and retrograde flows were analyzed by MRI during the first year after AD. RESULTS: After a median follow-up period of 8.0 years (IQR: 4.6-10.9 years), 43 patients presented aorta-related events (25 died and 18 required endovascular treatment). FL systolic antegrade flow ≥30% with respect to total systolic antegrade flow and retrograde diastolic flow ≥80% with respect to total diastolic FL flow were predictors of aortic events. In multivariate analysis, aortic diameter >45 mm (HR: 2.91), type B dissection (HR: 2.44), and MRI flow pattern (HR: 16.87) were independent predictors of AD-related events. CONCLUSIONS: High systolic antegrade flow volume in the FL with significant diastolic retrograde flow assessed by MRI and aortic diameter >45 mm identify patients with higher risk for complications in whom more aggressive management would be indicated.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/cirugía , Aorta , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Procedimientos Endovasculares/efectos adversos , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
J Clin Med ; 10(22)2021 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-34830543

RESUMEN

In acute ST-segment elevation myocardial infarction (STEMI) late gadolinium enhancement (LGE) may underestimate segmental functional recovery. We evaluated the predictive value of cardiac magnetic resonance (CMR) feature-tracking (FT) for functional recovery and whether it incremented the value of LGE compared to low-dose dobutamine stress echocardiography (LDDSE) and speckle-tracking echocardiography (STE). Eighty patients underwent LDDSE and CMR within 5-7 days after STEMI and segmental functional recovery was defined as improvement in wall-motion at 6-months CMR. Optimal conventional and FT parameters were analyzed and then also applied to an external validation cohort of 222 STEMI patients. Circumferential strain (CS) was the strongest CMR-FT predictor and addition to LGE increased the overall accuracy to 74% and was especially relevant in segments with 50-74% LGE (AUC 0.60 vs. 0.75, p = 0.001). LDDSE increased the overall accuracy to 71%, and in the 50-74% LGE subgroup improved the AUC from 0.60 to 0.69 (p = 0.039). LGE + CS showed similar value as LGE + LDDSE. In the validation cohort, CS was also the strongest CMR-FT predictor of recovery and addition of CS to LGE improved overall accuracy to 73% although this difference was not significant (AUC 0.69, p = 0.44). Conclusion: CS is the strongest CMR-FT predictor of segmental functional recovery after STEMI. Its incremental value to LGE is comparable to that of LDDSE whilst avoiding an inotropic stress agent. CS is especially relevant in segments with 50-74% LGE where accuracy is lower and further testing is frequently required to clarify the potential for recovery.

6.
J Am Soc Echocardiogr ; 34(4): 327-335, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33385502

RESUMEN

Mesenteric ischemia is a serious complication of acute aortic dissection (AAD), and its early diagnosis is vital for prognosis and appropriate treatment indication. Arteries affected by this complication are the celiac trunk and superior mesenteric artery, and their evaluation is usually based on computed tomographic angiography. Transesophageal echocardiography is also a useful technique for diagnosing AAD and is essential in monitoring surgical or endovascular treatment when computed tomographic angiography is not available. However, the usefulness of transesophageal echocardiography for evaluating celiac trunk and superior mesenteric artery involvement and mesenteric ischemia mechanisms in AAD is not well established. Real-time information on mesenteric malperfusion is needed at the bedside, in primary care facilities, and in the operating room to achieve prompt diagnosis and better therapeutic management. The aims of this review are to assess the role of TEE to diagnose celiac trunk and superior mesenteric artery involvement in AAD, determine the mechanisms that can cause flow obstruction in patients with mesenteric ischemia, and analyze possible implications in the treatment of this complication.


Asunto(s)
Disección Aórtica , Isquemia Mesentérica , Disección Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica , Humanos , Arteria Mesentérica Superior/diagnóstico por imagen , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/etiología , Pronóstico
7.
Basic Res Cardiol ; 116(1): 4, 2021 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-33495853

RESUMEN

Remote ischemic conditioning (RIC) and the GLP-1 analog exenatide activate different cardioprotective pathways and may have additive effects on infarct size (IS). Here, we aimed to assess the efficacy of RIC as compared with sham procedure, and of exenatide, as compared with placebo, and the interaction between both, to reduce IS in humans. We designed a two-by-two factorial, randomized controlled, blinded, multicenter, clinical trial. Patients with ST-segment elevation myocardial infarction receiving primary percutaneous coronary intervention (PPCI) within 6 h of symptoms were randomized to RIC or sham procedure and exenatide or matching placebo. The primary outcome was IS measured by late gadolinium enhancement in cardiac magnetic resonance performed 3-7 days after PPCI. The secondary outcomes were myocardial salvage index, transmurality index, left ventricular ejection fraction and relative microvascular obstruction volume. A total of 378 patients were randomly allocated, and after applying exclusion criteria, 222 patients were available for analysis. There were no significant interactions between the two randomization factors on the primary or secondary outcomes. IS was similar between groups for the RIC (24 ± 11.8% in the RIC group vs 23.7 ± 10.9% in the sham group, P = 0.827) and the exenatide hypotheses (25.1 ± 11.5% in the exenatide group vs 22.5 ± 10.9% in the placebo group, P = 0.092). There were no effects with either RIC or exenatide on the secondary outcomes. Unexpected adverse events or side effects of RIC and exenatide were not observed. In conclusion, neither RIC nor exenatide, or its combination, were able to reduce IS in STEMI patients when administered as an adjunct to PPCI.


Asunto(s)
Brazo/irrigación sanguínea , Exenatida/uso terapéutico , Incretinas/uso terapéutico , Precondicionamiento Isquémico , Miocardio/patología , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/terapia , Anciano , Terapia Combinada , Método Doble Ciego , Exenatida/efectos adversos , Femenino , Humanos , Incretinas/efectos adversos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Flujo Sanguíneo Regional , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/patología , Infarto del Miocardio con Elevación del ST/fisiopatología , España , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
8.
Rev Esp Cardiol (Engl Ed) ; 74(3): 257-262, 2021 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-32499017

RESUMEN

INTRODUCTION AND OBJECTIVES: Mortality is high in acute aortic syndrome (AAS), which therefore requires early treatment. This study aimed to analyze changes in the diagnosis and treatment of AAS over 20 years at our center. METHODS: From 1999 to 2018, 451 patients diagnosed with AAS (336 men; mean age, 60.9±12.4 years) were prospectively included (270 type A and 181 type B). Clinical variables, diagnosis, treatment, and in-hospital complications were analyzed. RESULTS: The use of computed tomography (CT) as the first-line diagnostic technique increased from 62.8% to 94.2% (P <.001). Surgical treatment of type A AAS rose from 67.4% to 82.5% (P=.09). Mortality from type A AAS decreased significantly from 53.1% to 26.3% (P <.001) as a result of the fall in mortality from surgical treatment (from 45.4% to 17.0%; P <.001). The use of medical treatment alone for type B AAS decreased from 91.8% to 61.7% (P <.001) due to the greater use of endovascular treatment. Mortality from type B AAS showed no significant reduction (16.2% to 10.6%; P=.15). CONCLUSIONS: The diagnosis and treatment of AAS has changed substantially in the last 2 decades. CT has become the first-line diagnostic technique for AAS. In type A AAS, mortality has fallen significantly due to improvements in the results of surgical treatment. In type B AAS, the use of medical treatment alone has decreased due to the expansion of endovascular treatment, although in-hospital mortality has not decreased significantly.


Asunto(s)
Aorta , Enfermedad Aguda , Anciano , Disección Aórtica , Procedimientos Endovasculares , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
9.
Int J Cardiol Heart Vasc ; 29: 100560, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32566723

RESUMEN

BACKGROUND: Strain analysis with speckle-tracking echocardiography (STE) is considered superior to ejection fraction for ventricular function assessment in different clinical scenarios. Feature tracking (FT) permits cardiac magnetic resonance (CMR) strain analysis in routinely acquired cine images. This study evaluated the feasibility of CMR-FT and its agreement with STE in patients with acute ST-segment elevation myocardial infarction (STEMI). METHODS: An echocardiogram and CMR were performed in 128 patients who underwent primary percutaneous revascularisation after a STEMI. Adequate strain analysis was obtained by both techniques in 98 patients and peak systolic longitudinal strain (LS) was assessed with STE and CMR-FT. RESULTS: Of 1568 myocardial segments, 97.2% were correctly tracked with STE and 97.7% with CMR-FT. For global LS, STE showed a mean of -14.8 ±â€¯3.3% and CMR-FT -13.7 ±â€¯3.0%, with good agreement between modalities [intraclass correlation coefficient (ICC) 0.826; bias -1.09%; limits of agreement (LOA) ±â€¯4.2%]. On the other hand, segmental LS agreement was only moderate, with an ICC of 0.678 (bias -1.14%; LOA ±â€¯11.76%) and the ICC ranged from 0.538 at the basal antero-lateral segment to 0.815 at the apical lateral segment. Finally, both STE and CMR-FT showed excellent intra- and inter-observer reproducibility (ICC > 0.9). CONCLUSIONS: CMR-FT provides LS with similar feasibility to STE and both techniques showed good agreement for global LS, although agreement at segmental level was only moderate. CMR-FT showed excellent reproducibility, strengthening its robustness and potential for both research and clinical applications.

10.
Ann Cardiothorac Surg ; 8(4): 456-470, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31463208

RESUMEN

Acute aortic syndromes include a variety of overlapping clinical and anatomic diseases. Intramural hematoma (IMH), penetrating atherosclerotic ulcer (PAU), and aortic dissection can occur as isolated processes or can be found in association. All these entities are potentially life threatening, so prompt diagnosis and treatment is of paramount importance. IMH and PAU affect patients with atherosclerotic risk factors and are located in the descending aorta in 60-70% of cases. IMH diagnosis can be correctly made in most cases. Aortic ulcer is a morphologic entity which comprises several entities-the differential diagnosis includes PAU, focal intimal disruptions (FID) in the context of IMH evolution and ulcerated atherosclerotic plaque. The pathophysiologic mechanism, evolution and prognosis differ somewhat between these entities. However, most PAU are diagnosed incidentally outside the acute phase. Persistent pain despite medical treatment, hemodynamic instability, maximum aortic diameter (MAD) >55 mm, significant periaortic hemorrhage and FID in acute phase of IMH are predictors of acute-phase mortality. In these cases, TEVAR or open surgery should be considered. In non-complicated IMH or PAU, without significant aortic enlargement, strict control of cardiovascular risk factors and frequent follow-up imaging appears to be a safe management strategy.

15.
J Am Coll Cardiol ; 69(1): 28-39, 2017 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-28057247

RESUMEN

BACKGROUND: Focal intimal disruption (FID) has been described in >20% of type B intramural hematomas (IMH), with unclear prognosis and management. OBJECTIVES: This study aimed to evaluate the short- and long-term evolution of medically treated patients with type B IMH with and without FID. METHODS: There were 107 consecutive patients with acute type B IMH were included prospectively in a multicenter protocol of clinical and imaging follow-up. FID was defined as an intimal disruption with contrast material-filled outpouching from the aorta lumen with a communicating orifice of >3 mm. RESULTS: There were 43 patients (40%) who developed an FID with larger basal maximum aortic diameter and hematoma thickness. Patients with acute FID had a higher risk of aorta-related events than those without FID (hazard ratio: 24.43; 95% confidence interval: 7.65 to 78.04; p < 0.001). Of the 94 discharged patients, 33 (35%) developed an FID within the first 6 months of follow-up: 19 evolved with mild (<1 mm/year), 8 with moderate (1 to 2 mm/year), and 6 with severe (>2 mm/year) aortic enlargement. Chronic FID was not associated with aorta-related events (hazard ratio: 0.98; 95% confidence interval: 0.22 to 4.34; p = 0.987). CONCLUSIONS: The development of FID in the acute phase of type B IMH has a poor prognosis owing to the high risk of aortic rupture. In the chronic phase, most FIDs evolve with slow aortic dilation and without complications. Although acute FIDs should be treated early and invasively, lesions developing in the subacute-chronic phase can be managed with medical treatment and close imaging surveillance.


Asunto(s)
Aorta Torácica , Aneurisma de la Aorta Torácica/complicaciones , Disección Aórtica/complicaciones , Hematoma/etiología , Túnica Íntima/diagnóstico por imagen , Anciano , Disección Aórtica/diagnóstico , Aneurisma de la Aorta Torácica/diagnóstico , Ecocardiografía Transesofágica , Procedimientos Endovasculares , Femenino , Estudios de Seguimiento , Hematoma/diagnóstico , Hematoma/cirugía , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Tomografía Computarizada Multidetector , Pronóstico , Estudios Prospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X
16.
PLoS One ; 12(1): e0170888, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28125720

RESUMEN

Aortic wall stiffness, tear size and location and the presence of abdominal side branches arising from the false lumen (FL) are key properties potentially involved in FL enlargement in chronic aortic dissections (ADs). We hypothesize that temporal variations on FL flow patterns, as measured in a cross-section by phase-contrast magnetic resonance imaging (PC-MRI), could be used to infer integrated information on these features. In 33 patients with chronic descending AD, instantaneous flow profiles were quantified in the FL at diaphragm level by PC-MRI. We used a lumped-parameter model to assess the changes in flow profiles induced by wall stiffness, tear size/location, and the presence of abdominal side branches arising from the FL. Four characteristic FL flow patterns were identified in 31/33 patients (94%) based on the direction of flow in systole and diastole: BA = systolic biphasic flow and primarily diastolic antegrade flow (n = 6); BR = systolic biphasic flow and primarily diastolic retrograde flow (n = 14); MA = systolic monophasic flow and primarily diastolic antegrade flow (n = 9); MR = systolic monophasic flow and primarily diastolic retrograde flow (n = 2). In the computational model, the temporal variation of flow directions within the FL was highly dependent on the position of assessment along the aorta. FL flow patterns (especially at the level of the diaphragm) showed their characteristic patterns due to variations in the cumulative size and the spatial distribution of the communicating tears, and the incidence of visceral side branches originating from the FL. Changes in wall stiffness did not change the temporal variation of the flows whereas it importantly determined intraluminal pressures. FL flow patterns implicitly codify morphological information on key determinants of aortic expansion in ADs. This data might be taken into consideration in the imaging protocol to define the predictive value of FL flows.


Asunto(s)
Aneurisma de la Aorta/fisiopatología , Disección Aórtica/fisiopatología , Velocidad del Flujo Sanguíneo/fisiología , Modelos Cardiovasculares , Rigidez Vascular/fisiología , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad
17.
J Am Soc Echocardiogr ; 29(9): 819-826.e4, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27288090

RESUMEN

BACKGROUND: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters. METHODS: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter- and intraobserver variability was analyzed. RESULTS: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter- and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 ± 2.6 mm [P = .158] for MDCT and 0.4 ± 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI. CONCLUSIONS: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.


Asunto(s)
Aorta/diagnóstico por imagen , Aorta/patología , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/patología , Ecocardiografía/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Anciano , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Clin Res Cardiol ; 105(6): 508-17, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26646556

RESUMEN

BACKGROUND AND PURPOSE: The risk of neurological damage following transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) in severe aortic stenosis patients deemed to be at intermediate surgical risk is unknown. In this target population, the degree of neurological damage was compared using brain diffusion-weighted magnetic resonance imaging (DW-MRI) and cognitive testing. METHODS: Forty-six consecutive patients undergoing TAVI (78.0 ± 8.3 years; STS score 4.4 ± 1.7) and 37 patients undergoing SAVR (78.9 ± 6.2 years, STS score 4.7 ± 1.7) were compared. DW-MRI was performed in 67 patients (40 in TAVI vs. 27 in SAVR group) within the first 15 days post-procedure. A cognitive assessment was performed at baseline and at 3 months follow-up. The occurrence of potential cognitive impairment post-intervention was determined using the reliable change index (RCI). RESULTS: Baseline characteristics were comparable in TAVI and SAVR groups except for the presence of severe calcified aorta, which occurred more frequently in the TAVI group [17 (37 %) vs. 0 (0 %), p < 0.001]. Three patients presented a clinical stroke: 1 (2.2 %) in TAVI group vs. 2 (5.4 %) in SAVR group, (p = 0.58). No differences were observed in the rate of acute ischemic cerebral lesions detected by DWI in patients undergoing TAVI vs. SAVR [18 (45 %) in TAVI vs. 11 (40.7 %) in SAVR, adjusted OR 0.95; 95 % CI 0.25-3.65; p = 0.94]. TAVI was associated with a lower number of DWI lesions (adjusted OR 0.54; 95 % IC 0.37-0.79; p = 0.02). An older age was a predictor of the occurrence of acute lesions (OR 1.13; 95 % CI 1.03-1.23; p = 0.01), and the use of vitamin-K antagonist therapy had a protective effect (OR 0.25; 95 % CI 0.07-0.92; p = 0.037) regardless the type of intervention. Overall no significant changes were observed in global cognitive scores post-intervention (p = 0.23). The RCI showed mild cognitive decline in nine patients undergoing TAVI (26.4 %) and in six patients in the SAVR group (30.0 %) (p = 0.96). There was no association between the number and total volume of lesions and the occurrence of cognitive decline (CC Spearman 0.031, p = 0.85 and -0.011, p = 0.97, respectively). CONCLUSIONS: TAVI and SAVR were associated with a similar rate of acute silent ischemic cerebral lesions in intermediate risk patients. Although acute lesions occurred very frequently in both strategies, their cognitive impact was not clinically relevant.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/cirugía , Isquemia Encefálica/etiología , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/fisiopatología , Isquemia Encefálica/psicología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Distribución de Chi-Cuadrado , Cognición , Imagen de Difusión por Resonancia Magnética , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Modelos Logísticos , Masculino , Análisis Multivariante , Pruebas Neuropsicológicas , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...