Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Injury ; 48(10): 2169-2173, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28823386

RESUMEN

BACKGROUND: The feasibility of harvesting a vascularized iliac crest utilizing the Pararectus approach was assessed in cadavers and then this new technique was implemented in a clinical case. METHODS: Bilaterally in five cadavers the branches of both external iliac arteries were injected with colored silicone to assess their position to each other and to harvest a bone graft vascularized by the deep circumflex iliac artery (DCIA) through the Pararectus approach. This technique was implemented in a 68-years-old female patient, initially admitted to a level-I-trauma center after sustaining multiple injuries by falling from great height. For definitive treatment of a severely contaminated medially open (Gustilo-Anderson Type 3A) calcaneal luxation fracture (Sanders type IIIBC) in this patient a vascularized iliac crest autograft harvest by the Pararectus approach was used for reconstructive surgery. RESULTS: The DCIA and the deep inferior epigastric vessels (DIEV: vascularizing the rectus abdominis muscle and main pedicle of the inferiorly based rectus abdominis myocutaneous flap) are very close on the lateral and medial border of the external iliac artery, respectively. As a consequence, the retrograde dissection of the DIEV towards the DCIA through the Pararectus approach made the dissection of the vascularized iliac crest more amenable, preserving both the lateral femoral cutaneous and the genitofemoral nerves. Four months after the surgery the patient was able to fully weight-bear in orthopedic shoes. Radiographs and CT scans showed correct hind foot alignment and bony integration of the vascularized iliac crest graft into the residual calcaneal body. CONCLUSION: The Pararectus approach allowed for secure collection of large vascularized iliac grafts. The presented technique was successful as a salvage procedure in a clinical case with substantial bone loss after an open calcaneal fracture.


Asunto(s)
Acetábulo/cirugía , Trasplante Óseo , Calcáneo/cirugía , Fracturas Óseas/cirugía , Fracturas Abiertas/cirugía , Arteria Ilíaca/trasplante , Ilion/trasplante , Recolección de Tejidos y Órganos/métodos , Accidentes por Caídas , Acetábulo/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Trasplante Óseo/métodos , Cadáver , Calcáneo/patología , Femenino , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/fisiopatología , Fracturas Abiertas/diagnóstico por imagen , Fracturas Abiertas/fisiopatología , Humanos , Masculino , Colgajos Quirúrgicos/irrigación sanguínea , Resultado del Tratamiento
2.
Biomed Res Int ; 2017: 8231301, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28698880

RESUMEN

Acetabular fractures involving predominantly the anterior column associated with a disruption of the quadrilateral surface can be treated with instrumentation implementing the stabilization of the quadrilateral surface. The recently introduced suprapectineal quadrilateral buttress plate is specifically designed to prevent secondary medial subluxation of the femoral head, especially in elderly patients with reduced ability for partial weight bearing. Whereas there are guidelines available for safe screw fixation for the anterior and posterior columns, there might be a concern for intra-articular placement of screws placed through the infrapectineal part of the quadrilateral buttress plate. Within this report we analyzed retrospectively screw placement in 30 plates in postoperative CT scans using algorithms for metal artifact reduction. None of the screws of the buttress plate penetrated the hip joint. We describe the placement, length, and spatial orientation of the screws used for fracture fixation and suggest that the use of intraoperative image intensifiers with a combined inlet-obturator view of 30-45° best projects the screws and the hip joint. Preoperative knowledge of approximate screw placement and information for accurate intraoperative imaging may contribute to safe acetabular fracture fixation and may reduce operating time and limit radiation exposure to the patient and the personnel. This trial is registered with KEK-BE: 266/2014.


Asunto(s)
Acetábulo , Placas Óseas , Tornillos Óseos , Fracturas Óseas , Acetábulo/diagnóstico por imagen , Acetábulo/lesiones , Anciano , Anciano de 80 o más Años , Femenino , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Humanos , Masculino , Persona de Mediana Edad
3.
Injury ; 48(8): 1825-1830, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28687363

RESUMEN

INTRODUCTION: A preoperative planning approach for percutaneous screw fixation of the iliosacral joint provides specific entry points (EPs) and aiming points (APs) of intraosseous screw pathways (as defined by CT scans) for lateral fluoroscopic projections used intraoperatively. The potential to achieve the recommended EPs and APs, to obtain an ideal screw position (perpendicular to the iliosacral joint), to avoid occurrence of extraosseous screw misplacement, to reduce the operating time and the radiation exposure by utilizing this planning approach have not been described yet. METHODS: On preoperative CT scans of eight human cadaveric specimen individual EPs and APs were identified and transferred to the lateral fluoroscopic projection using a coordinate system with the zero-point in the center of the posterior cortex of the S1 vertebral body (x-axis parallel to upper S1 endplate). Distances were expressed in relation to the anteroposterior distance of the S1 upper endplate (in%). In each specimen on one side a screw was placed with provided EP and AP (New Technique) whereas at the contralateral side a screw was placed without given EP and AP (Conventional Technique). Both techniques were compared using postoperative CT scans to assess distances between predefined EPs and APs and the actually obtained EPs and APs, screw angulations in relation to the iliosacral joint in coronal and axial planes and the occurrence of any extraosseous screw misplacement. The "operating time (OT)" and the "time under fluoroscopy (TUF)" were recorded. Statistical analysis was performed by the Wilcoxon signed-rank test. RESULTS: EPs were realized significantly more accurate using the new technique in vertical direction. The screw positions in relation to the iliosacral joint showed no significant difference between both techniques. Both techniques had one aberrantly placed screw outside the safe corridor. The (mean±SD) "OT" and the (mean±SD) "TUF" were significantly decreased using the new technique compared to the conventional technique (OT: 7.6±2min versus 13.1±5.8min, p=0.012; TUF: 1.5±0.8min versus 2.2±1.1min). CONCLUSION: The presented preoperative planning approach increases the accuracy in percutaneous screw fixation of the iliosacral joint, reduces operating time and minimizes radiation exposure to patient and staff.


Asunto(s)
Fluoroscopía , Fijación Interna de Fracturas , Fracturas Óseas/cirugía , Ilion/cirugía , Cuidados Preoperatorios/métodos , Exposición a la Radiación/prevención & control , Sacro/cirugía , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Humanos , Ilion/anatomía & histología , Ilion/diagnóstico por imagen , Tempo Operativo , Guías de Práctica Clínica como Asunto , Exposición a la Radiación/efectos adversos , Reproducibilidad de los Resultados , Sacro/anatomía & histología , Sacro/diagnóstico por imagen
4.
Injury ; 47(3): 695-701, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26861799

RESUMEN

BACKGROUND: As an alternative to the modified Stoppa approach, the Pararectus approach is used clinically for treatment of acetabular fractures involving the anterior column. The current study assessed the surgical exposure and the options for instrumentation using both of these approaches. METHODS: Surgical dissections were conducted on five human cadavers (all male, mean age 88 years (82-97)) using the modified Stoppa and the Pararectus approach, with the same skin incision length (10cm). Distal boundaries of the exposed bony surfaces were marked using a chisel. After removal of all soft-tissues, distances from the boundaries in the false and true pelvis were measured with reference to the pelvic brim. The exposed bone was coloured and calibrated digital images of each inner hemipelvis were taken. The amount of exposed surface using both approaches was assessed and represented as a percentage of the total bony surface of each hemipelvis. For instrumentation, a suprapectineal quadrilateral buttress plate was used. Screw lengths were documented, and three-dimensional CT reconstructions were performed to assess screw trajectories qualitatively. Wilcoxon's signed rank test for paired groups was used (level of significance: p<0.05). RESULTS: After utilization of the Pararectus approach, the distances from the farthest boundaries of exposed bone towards the pelvic brim were significantly higher in the false but not the true pelvis, compared to the modified Stoppa approach. The percentage (mean±SD) of exposed bone accessible after utilizing the Pararectus approach was 42±8%, compared to 29±6% using the modified Stoppa (p=0.011). In cadavers exposed by the Pararectus approach, screws placed for posterior fixation and as a posterior column screw were longer by factor 1.8 and 2.1, respectively (p<0.05), and screws could be placed more posteromedial towards the posterior inferior iliac spine or in line with the posterior column directed towards the ischial tuberosity. CONCLUSION: Compared to the modified Stoppa, the Pararectus approach facilitates a greater surgical access in the false pelvis, provides versatility for fracture fixation in the posterior pelvic ring and allows for the option to extend the approach without a new incision.


Asunto(s)
Acetábulo/cirugía , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Huesos Pélvicos/cirugía , Acetábulo/anatomía & histología , Acetábulo/patología , Anciano de 80 o más Años , Placas Óseas , Tornillos Óseos , Cadáver , Disección/métodos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Humanos , Masculino , Huesos Pélvicos/anatomía & histología , Huesos Pélvicos/patología , Tomografía Computarizada por Rayos X
5.
Injury ; 46(10): 2003-9, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26190629

RESUMEN

INTRODUCTION: In iliosacral screw fixation, the dimensions of solely intraosseous (secure) pathways, perpendicular to the ilio-sacral articulation (optimal) with corresponding entry (EP) and aiming points (AP) on lateral fluoroscopic projections, and the factors (demographic, anatomic) influencing these have not yet been described. METHODS: In 100 CTs of normal pelvises, the height and width of the secure and optimal pathways were measured on axial and coronal views bilaterally (total measurements: n=200). Corresponding EP and AP were defined as either the location of the screw head or tip at the crossing of lateral innominate bones' cortices (EP) and sacral midlines (AP) within the centre of the pathway, respectively. EP and AP were transferred to the sagittal pelvic view using a coordinate system with the zero-point in the centre of the posterior cortex of the S1 vertebral body (x-axis parallel to upper S1 endplate). Distances are expressed in relation to the anteroposterior distance of the S1 upper endplate (in %). The influence of demographic (age, gender, side) and/or anatomic (PIA=pelvic incidence angle; TCA=transversal curvature angle, PID-Index=pelvic incidence distance-index; USW=unilateral sacral width-index) parameters on pathway dimensions and positions of EP and AP were assessed (multivariate analysis). RESULTS: The width, height or both factors of the pathways were at least 7mm or more in 32% and 53% or 20%, respectively. The EP was on average 14±24% behind the centre of the posterior S1 cortex and 41±14% below it. The AP was on average 53±7% in the front of the centre of the posterior S1 cortex and 11±7% above it. PIA influenced the width, TCA, PID-Index the height of the pathways. PIA, PID-Index, and USW-Index significantly influenced EP and AP. Age, gender, and TCA significantly influenced EP. CONCLUSION: Secure and optimal placement of screws of at least 7mm in diameter will be unfeasible in the majority of patients. Thoughtful preoperative planning of screw placement on CT scans is advisable to identify secure pathways with an optimal direction. For this purpose, the presented methodology of determining and transferring EPs and APs of corresponding pathways to the sagittal pelvic view using a coordinate system may be useful.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas/cirugía , Ilion/cirugía , Huesos Pélvicos/cirugía , Sacro/cirugía , Tomografía Computarizada por Rayos X , Adulto , Tornillos Óseos , Hilos Ortopédicos , Fluoroscopía , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/fisiopatología , Humanos , Ilion/anatomía & histología , Ilion/diagnóstico por imagen , Huesos Pélvicos/anatomía & histología , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/lesiones , Guías de Práctica Clínica como Asunto , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sacro/anatomía & histología , Sacro/diagnóstico por imagen
6.
Clin Radiol ; 70(1): 54-61, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25459197

RESUMEN

AIM: To compare image quality and diagnostic confidence of 100 kVp CT pulmonary angiography (CTPA) in patients with body weights (BWs) below and above 100kg. MATERIALS AND METHODS: The present retrospective study comprised 216 patients (BWs of 75-99kg, 114 patients; 100-125kg, 88 patients; >125kg, 14 patients), who received 100 kVp CTPA to exclude pulmonary embolism. The attenuation was measured and the contrast-to-noise ratio (CNR) was calculated in the pulmonary trunk. Size-specific dose estimates (SSDEs) were evaluated. Three blinded radiologists rated subjective image quality and diagnostic confidence. Results between the BW groups and between three body mass index (BMI) groups (BMI <25kg/m(2), BMI = 25-29.9kg/m(2), and BMI ≥30kg/m(2), i.e., normal weight, overweight, and obese patients) were compared using the Kruskal-Wallis test. RESULTS: Vessel attenuation was higher and SDDE was lower in the 75-99kg group than at higher BWs (p-values between <0.001 and 0.03), with no difference between the 100-125 and >125kg groups (p = 0.892 and 1). Subjective image quality and diagnostic confidence were not different among the BW groups (p = 0.225 and 1). CNR was lower (p < 0.006) in obese patients than in normal weight or overweight subjects. Diagnostic confidence was not different in the BMI groups (p = 0.105). CONCLUSION: CTPA at 100 kVp tube voltage can be used in patients weighing up to 125kg with no significant deterioration of subjective image quality and confidence. The applicability of 100 kVp in the 125-150kg BW range needs further testing in larger collectives.


Asunto(s)
Angiografía/normas , Sobrepeso/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/normas , Adulto , Anciano , Angiografía/métodos , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
7.
Neurogastroenterol Motil ; 25(9): 749-e577, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23741963

RESUMEN

BACKGROUND: The objective of the study was to correlate MR-detectable motility alterations of the terminal ileum with biopsy-documented active and chronic changes in Crohn's disease. METHODS: This IRB approved retrospective analysis of 43 patients included magnetic resonance enterography (MRE) and terminal ileum biopsies (<2 weeks apart). Motility was measured at the terminal ileum using coronal 2D trueFISP pulse sequences (1.5T MRI,TR 83.8,TE1.89) and dedicated motility assessment software. Motility grading (hypermotility, normal, hypomotility, complete arrest) was agreed by two experienced readers. Motility was compared and correlated with histopathology using two-tailed Kruskal-Wallis test and paired Spearman Rank-Order Correlation tests. KEY RESULTS: Motility abnormalities were present in 27/43 patients: nine hypomotility and 18 complete arrest. Active disease was diagnosed on 15 biopsies: eight moderate and seven severe inflammatory activity. Chronic changes were diagnosed on 17 biopsies: 13 moderate and four severe cases. In four patients with normal motility alterations on histopathology were diagnosed. Histopathology correlated with presence (P = 0.0056 for hypomotility and P = 0.0119 for complete arrest) and grade (P < 0.0001; P = 0.0004) of motility alterations. A significant difference in the motility was observed in patients with active or chronic CD compared with patients without disease (P < 0.001; P = 0.0024). CONCLUSIONS & INFERENCES: MR-detectable motility changes of the terminal ileum correlate with histopathological findings both in active and chronic CD. Motility changes may indicate the presence pathology, but do not allow differentiation of active and chronic disease.


Asunto(s)
Enfermedad de Crohn/patología , Enfermedad de Crohn/fisiopatología , Motilidad Gastrointestinal/fisiología , Íleon/patología , Íleon/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
8.
J Bone Joint Surg Br ; 94(3): 405-11, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22371551

RESUMEN

A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five 'windows' for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called 'Pararectus' approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (sd 2.6) vs 0.1 mm (sd 0.3), p < 0.001; and mean gap 11.5 mm (sd 6.5) vs 0.8 mm (sd 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues. In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access.


Asunto(s)
Acetábulo/lesiones , Acetábulo/cirugía , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Pelvis/anatomía & histología , Acetábulo/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas , Tornillos Óseos , Disección/métodos , Estudios de Factibilidad , Femenino , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Recto del Abdomen/cirugía , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA