1.
J Microelectromech Syst ; 23(3): 570-578, 2014 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-25673965

RESUMEN

This paper presents the design and characterization of a three-axis thermomechanical actuator-based endoscopic scanner for obtaining ex vivo two-photon images. The scanner consisted of two sub-systems: 1) an optical system (prism, gradient index lens, and optical fiber) that was used to deliver and collect light during imaging and 2) a small-scale silicon electromechanical scanner that could raster scan the focal point of the optics through a specimen. The scanner can be housed within a 7 mm Ø endoscope port and can scan at the speed of 3 kHz × 100 Hz × 30 Hz along three axes throughout a 125 × 125 × 100 µm3 volume. The high-speed thermomechanical actuation was achieved through the use of geometric contouring, pulsing technique, and mechanical frequency multiplication (MFM), where MFM is a new method for increasing the device cycling speed by pairing actuators of unequal forward and returning stroke speeds. Sample cross-sectional images of 15-µm fluorescent beads are presented to demonstrate the resolution and optical cross-sectioning capability of the two-photon imaging system.

2.
Nanotechnology ; 23(32): 325501, 2012 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-22825308

RESUMEN

This paper presents the design and fabrication of a multi-axis microelectromechanical system (MEMS) force sensor with integrated carbon nanotube (CNT)-based piezoresistive sensors. Through the use of proper CNT selection and sensor fabrication techniques, the performance of the CNT-based MEMS force sensor was increased by approximately two orders of magnitude as compared to current CNT-based sensor systems. The range and resolution of the force sensor were determined as 84 µN and 5.6 nN, respectively. The accuracy of the force sensor was measured to be better than 1% over the device's full range.

3.
J Med Device ; 3(2): 25001, 2009 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-20352058

RESUMEN

This paper focuses on the design and implementation of a percutaneous catheter-based device to provide physicians with an externally controlled tool capable of manipulating and cutting specific chordae tendinae within the hear to alleviate problems associated with some forms of mitral valve regurgitationt. In the United States alone, approximately 500,000 people develop ischemic or functional MR per year, and the chordae tendinae cutting procedure and device are needed because many patients do not have the required level of health necessary to survive open-heart surgery. A deterministic design process was used to generate several design concepts and then evaluate and compare each concept based on a set of functional requirements. A final concept to be alpha prototyped was then chosen, further developed, and fabricated. Experiments showed that the design was capable of locating and grabbing a chord and that ultrasound imaging is a viable method for navigating the device inside of the human body. Once contact between the chord and an RF ablator tip was confirmed, the chord was successfully ablated.