Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Urol ; 211(2): 276-284, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38193415

RESUMEN

PURPOSE: The consumption of alkaline water, water with an average pH of 8 to 10, has been steadily increasing globally as proponents claim it to be a healthier alternative to regular water. Urinary alkalinization therapy is frequently prescribed in patients with uric acid and cystine urolithiasis, and as such we analyzed commercially available alkaline waters to assess their potential to increase urinary pH. MATERIALS AND METHODS: Five commercially available alkaline water brands (Essentia, Smart Water Alkaline, Great Value Hydrate Alkaline Water, Body Armor SportWater, and Perfect Hydration) underwent anion chromatography and direct chemical measurements to determine the mineral contents of each product. The alkaline content of each bottle of water was then compared to that of potassium citrate (the gold standard for urinary alkalinization) as well as to other beverages and supplements used to augment urinary citrate and/or the urine pH. RESULTS: The pH levels of the bottled alkaline water ranged from 9.69 to 10.15. Electrolyte content was minimal, and the physiologic alkali content was below 1 mEq/L for all brands of alkaline water. The alkali content of alkaline water is minimal when compared to common stone treatment alternatives such as potassium citrate. In addition, several organic beverages, synthetic beverages, and other supplements contain more alkali content than alkaline water, and can achieve the AUA and European Association of Urology alkali recommendation of 30 to 60 mEq per day with ≤ 3 servings/d. CONCLUSIONS: Commercially available alkaline water has negligible alkali content and thus provides no added benefit over tap water for patients with uric acid and cystine urolithiasis.


Asunto(s)
Ácido Úrico , Urolitiasis , Humanos , Cistina , Citrato de Potasio/uso terapéutico , Urolitiasis/terapia , Álcalis
2.
J Endourol ; 38(4): 316-322, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38243836

RESUMEN

Purpose: Ureteral access sheaths (UAS) pose the risk of severe ureteral injury. Our prior studies revealed forces ≤6 Newtons (N) prevent ureteral injury. Accordingly, we sought to define the force urologists and residents in training typically use when placing a UAS. Materials and Methods: Among urologists and urology residents attending two annual urological conferences in 2022, 121 individuals were recruited for the study. Participants inserted 12F, 14F, and 16F UAS into a male genitourinary model containing a concealed force sensor; they also provided demographic information. Analysis was completed using t-tests and Chi-square tests to identify group differences when passing a 16F sheath UAS. Participant traits associated with surpassing or remaining below a minimal force threshold were also explored through polychotomous logistic regression. Results: Participant force distributions were as follows: ≤4N (29%), >6N (45%), and >8N (32%). More years of practice were significantly associated with exerting >6N relative to forces between 4N and 6N; results for >8N relative to 4N and 8N were similar. Compared to high-volume ureteroscopists (those performing >20 ureteroscopies/month), physicians performing ≤20 ureteroscopies/month were significantly less likely to exert forces ≤4N (p = 0.017 and p = 0.041). Of those surpassing 6N and 8N, 15% and 18%, respectively, were high-volume ureteroscopists. Conclusions: Despite years of practice or volume of monthly ureteroscopic cases performed, most urologists failed to pass 16F access sheaths within the ideal range of 4N to 6N (74% of participants) or within a predefined safe range of 4N to 8N (61% of participants).


Asunto(s)
Uréter , Enfermedades Urológicas , Humanos , Masculino , Uréter/cirugía , Ureteroscopía/métodos , Urólogos
3.
J Urol ; 211(2): 256-265, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37889957

RESUMEN

PURPOSE: Given the shortcomings of current stone burden characterization (maximum diameter or ellipsoid formulas), we sought to investigate the diagnostic accuracy and precision of a University of California, Irvine-developed artificial intelligence (AI) algorithm for determining stone volume determination. MATERIALS AND METHODS: A total of 322 noncontrast CT scans were retrospectively obtained from patients with a diagnosis of urolithiasis. The largest stone in each noncontrast CT scan was designated the "index stone." The 3D volume of the index stone using 3D Slicer technology was determined by a validated reviewer; this was considered the "ground truth" volume. The AI-calculated index stone volume was subsequently compared with ground truth volume as well with the scalene, prolate, and oblate ellipsoid formulas estimated volumes. RESULTS: There was a nearly perfect correlation between the AI-determined volume and the ground truth (R=0.98). While the AI algorithm was efficient for determining the stone volume for all sizes, its accuracy improved with larger stone size. Moreover, the AI stone volume produced an excellent 3D pixel overlap with the ground truth (Dice score=0.90). In comparison, the ellipsoid formula-based volumes performed less well (R range: 0.79-0.82) than the AI algorithm; for the ellipsoid formulas, the accuracy decreased as the stone size increased (mean overestimation: 27%-89%). Lastly, for all stone sizes, the maximum linear stone measurement had the poorest correlation with the ground truth (R range: 0.41-0.82). CONCLUSIONS: The University of California, Irvine AI algorithm is an accurate, precise, and time-efficient tool for determining stone volume. Expanding the clinical availability of this program could enable urologists to establish better guidelines for both the metabolic and surgical management of their urolithiasis patients.


Asunto(s)
Cálculos Renales , Urolitiasis , Humanos , Inteligencia Artificial , Cálculos Renales/diagnóstico por imagen , Estudios Retrospectivos , Algoritmos , Tomografía Computarizada por Rayos X , Urolitiasis/diagnóstico por imagen
4.
Urol Pract ; 10(5): 434, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37505900
5.
J Endourol ; 37(9): 1049-1056, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37493542

RESUMEN

Introduction: The metal-based Resonance stent (RS) has traditionally been placed in patients with malignant ureteral obstruction; as such, the long-term utility of RS among patients with benign ureteral obstruction (BUO) remains underinvestigated. Methods: We retrospectively reviewed our database for patients with BUO who underwent RS placement between 2010 and 2020. The impact of chronic RS placement on renal function was evaluated by estimated serum creatinine-based glomerular filtration rate (eGFR), furosemide renal scan, and CT-based renal parenchymal volume measurement. The number of and reason for RS stent exchanges during the follow-up period, incidence of encrustation, and the average indwell time were recorded. A cost analysis of placing the RS vs a polymeric stent was performed. Results: Among 43 RS patients with BUO, at a mean follow-up of 26 months, there was no change in eGFR (p = 0.99), parenchymal volume (p = 0.44), or split renal function of the stent-bearing side on renal scan (p = 0.48). The mean RS indwell time was 9.7 months. Eleven patients (26%) underwent premature stent replacement (6 cases) or removal (5 cases). Stents in 9 patients (32%) were encrusted, of which 4 (44%) required laser lithotripsy. Overall, 25 patients (58%) and 12 patients (28%) had a mean stent indwell time of ≥6 months and ≥12 months, respectively. Placing an RS resulted in a 52%, 37%, and 5.6% cost reduction compared with a regular polymeric stent placement, where it was exchanged every 6, 4, or 3 months, respectively. Conclusions: RS deployment in the patient with a BUO results in cost-effective maintenance of renal function and of renal parenchymal volume at a mean follow-up of 2 years; however, only 28% of patients fulfilled the 1-year criterion for RS indwell time.


Asunto(s)
Uréter , Obstrucción Ureteral , Humanos , Obstrucción Ureteral/etiología , Estudios Retrospectivos , Riñón/fisiología , Stents/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...