Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Brain Commun ; 6(4): fcae231, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39056027

RESUMEN

Patients with epilepsy are characterized by a dysregulation of excitation/inhibition balance (E/I). The assessment of E/I may inform clinicians during the diagnosis and therapy management, even though it is rarely performed. An accessible measure of the E/I of the brain represents a clinically relevant feature. Here, we exploited the exponent of the aperiodic component of the power spectrum of the electroencephalography (EEG) signal, as a non-invasive and cost-effective proxy of the E/I balance. We recorded resting-state activity with high-density EEG from 67 patients with temporal lobe epilepsy and 35 controls. We extracted the exponent of the aperiodic fit of the power spectrum from source-reconstructed EEG and tested differences between patients with epilepsy and controls. Spearman's correlation was performed between the exponent and clinical variables (age of onset, epilepsy duration and neuropsychology) and cortical expression of epilepsy-related genes derived from the Allen Human Brain Atlas. Patients with temporal lobe epilepsy showed a significantly larger exponent, corresponding to inhibition-directed E/I balance, in bilateral frontal and temporal regions. Lower E/I in the left entorhinal and bilateral dorsolateral prefrontal cortices corresponded to a lower performance of short-term verbal memory. Limited to patients with temporal lobe epilepsy, we detected a significant correlation between the exponent and the cortical expression of GABRA1, GRIN2A, GABRD, GABRG2, KCNA2 and PDYN genes. EEG aperiodic exponent maps the E/I balance non-invasively in patients with epilepsy and reveals a close relationship between altered E/I patterns, cognition and genetics.

2.
Sci Rep ; 14(1): 14039, 2024 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-38890363

RESUMEN

The epilepsy diagnosis still represents a complex process, with misdiagnosis reaching 40%. We aimed at building an automatable workflow, helping the clinicians in the diagnosis of temporal lobe epilepsy (TLE). We hypothesized that neuronal avalanches (NA) represent a feature better encapsulating the rich brain dynamics compared to classically used functional connectivity measures (Imaginary Coherence; ImCoh). We analyzed large-scale activation bursts (NA) from source estimation of resting-state electroencephalography. Using a support vector machine, we reached a classification accuracy of TLE versus controls of 0.86 ± 0.08 (SD) and an area under the curve of 0.93 ± 0.07. The use of NA features increase by around 16% the accuracy of diagnosis prediction compared to ImCoh. Classification accuracy increased with larger signal duration, reaching a plateau at 5 min of recording. To summarize, NA represents an interpretable feature for an automated epilepsy identification, being related with intrinsic neuronal timescales of pathology-relevant regions.


Asunto(s)
Encéfalo , Electroencefalografía , Epilepsia del Lóbulo Temporal , Neuronas , Epilepsia del Lóbulo Temporal/diagnóstico , Epilepsia del Lóbulo Temporal/fisiopatología , Humanos , Electroencefalografía/métodos , Masculino , Encéfalo/fisiopatología , Encéfalo/diagnóstico por imagen , Adulto , Neuronas/fisiología , Femenino , Persona de Mediana Edad , Máquina de Vectores de Soporte , Adulto Joven
3.
Front Surg ; 10: 1302976, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38074286

RESUMEN

Background: Temporary intravascular shunts (TIVS) may allow quick revascularization and distal reperfusion, reducing the ischemic time (IT) when an arterial injury occurs. Furthermore, TIVS temporarily restore peripheral perfusion during the treatment of concomitant life-threatening injuries or when patients require evacuation to a higher level of care. Notwithstanding, there are still disputes regarding the use of TIVS, in view of the paucity of evidence in terms of potential benefits and with regard to the anticoagulation during the procedure. The present study aimed to assess TIVS impact, safety, and timing on limb salvage in complex civilian vascular traumas. Patients and methods: Data were retrieved from the prospective database of our department, which included all patients hospitalized with a vascular injury of the extremities between January 2006 and December 2022. Patients undergoing TIVS during vascular injury management were included in group A, and those who could not postpone immediate care for TIVS insertion were included in group B (control group). Data concerning the times required for extremity revascularization or other surgical procedures such as orthopedic interventions and the time of limb ischemia were compared between the two groups. A comparison of the postoperative course between the two groups was also performed. Results: A total of 53 patients were included: group A (TIVS insertion, n = 31) and group B (control, n = 22). Revascularization time significantly differed (p = 0.002) between the two groups, which is lower in group A (4.17 ± 2.37 h vs. 5.81 ± 1.26 h). TIVS positively affected the probability of limb salvage (p = 0.02). At multivariate analysis, the factors independently associated with limb salvage were TIVS usage, the necessity of hyperbaric oxygen therapy, and the total IT. In group A, there were three deaths and one major amputation, and in group B, there were two deaths and four major amputations. Conclusions: The use of TIVS minimizes revascularization time and improves limb salvage probability. A multidisciplinary approach is recommended, and correct surgical timing is key to ensure the best outcome.

4.
J Clin Med ; 12(13)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37445398

RESUMEN

BACKGROUND: There is significant debate regarding the existence of sex-related differences in the presentation, treatment, and outcomes of men versus women affected by abdominal aortic aneurysm (AAA). The purpose of this study is to compare endovascular aneurysm repair (EVAR) of infrarenal AAAs with the current sex-neutral 5.0-5.5 cm-diameter threshold for intervention between the two sexes. METHODS: Retrospective review of consecutive cases from a single teaching institution over a period of five years of patients who had undergone elective EVAR for AAAs between 5.0 and 5.5 cm in diameter. Outcomes of interest were compared according to sex. RESULTS: Ninety-four patients were included in the analysis, with a higher prevalence of men (53%). Females were older at the time of repair, 78 ± 5.1 years, versus 71.7 ± 7 years (p < 0.01), and had higher incidence of underlying comorbidities, namely, arrhythmia, chronic kidney disease, and previous carotid revascularization. Women had higher incidence of immediate systemic complications (p = 0.021), post-operative AMI (p = 0.001), arrhythmia (p = 0.006), pulmonary oedema (p < 0.001), and persistent renal dysfunction (p = 0.029). Multivariate analysis for post-operative factors associated to mortality and adjusted for sex confirmed that AMI (p = 0.015), arrhythmia (p = 0.049), pulmonary oedema (p = 0.015), persistent renal dysfunction (p < 0.001), cerebral ischemia (p < 0.001), arterial embolism of lower limbs (p < 0.001), and deep-vein thrombosis of lower limbs (p < 0.001) were associated to higher EVAR-related mortality; a higher incidence of post-operative AMI (p = 0.014), pulmonary edema (p = 0.034), and arterial embolism of lower limbs (p = 0.046) were associated to higher 30-days mortality. In females there was also a higher rate of suprarenal fixation (p = 0.026), insertion outside the instruction for use (p = 0.035), and a more hostile neck anatomy with different proximal aortic diameter (p < 0.001) and angle (p = 0.003). CONCLUSIONS: A similar threshold of size of AAA for elective surgery for both males and females might not be appropriate for surgical intervention, as females tend to have worse outcomes. Further population-based studies are needed to guide on sex-related differences and intervention on AAA.

5.
Ann Vasc Surg ; 88: 346-353, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36058461

RESUMEN

BACKGROUND: Alto is the latest generation of the Ovation stent-graft platform for endovascular aneurysm repair (EVAR). Its ultra-low profile and its proximal sealing zone close to the lowest renal artery (≥7 mm) increase standard EVAR eligibility. We report early clinical and technical outcomes with the Alto stent-graft in our University Hospital Center after CE Mark approval in August 2020. METHODS: Seven patients (all male, mean age 76.1 ± 6.2 years) underwent EVAR with Ovation Alto stent-graft between June 2021 and February 2022. All the EVAR procedures were performed by a team of vascular surgeons experienced on EVAR with previous generation of Ovation platform. Follow-up consisted of duplex ultrasound examination at 1, 3, and 6 months and of a 1-month control computed tomography angiography (CTA). Patients treated gave consent to participate in this case series and publication. A descriptive analysis of variables was performed. SPSS (version 25) and Excel were used for statistical analysis. RESULTS: Most of the patients had a fusiform abdominal aortic aneurysm (n = 5; 71.4%). The median maximal transversal aortic diameter was 5.06 cm (range, 3.98-6.99). Because of hostile aortic neck anatomy, on-label EVAR was considered feasible only with Ovation Alto stent-graft. Narrow iliac arteries (<6 mm) were also present in 2 cases. All procedures were performed according to the instruction for the use of the device. Technical success was achieved in all cases. No type IA/IB/III endoleak occurred at completion angiography. No distal migration (>10 mm) but 2 distal displacements (≥2 mm) were observed at control CTA. During follow-up, duplex ultrasound and CTA showed no type I/III endoleak, no stent-graft migration (>10 mm), and no proximal aortic neck variations (P = not statistically significant). Three patients (42.8%) are under strict surveillance because of low-flow type II endoleak not associated with sac variations. CONCLUSIONS: Our early experience shows promising technical and clinical success with Alto stent-graft. The proximal relocation of the proximal sealing rings and the ultra-low profile delivery system allow on-label EVAR in a wider range of aortic anatomies. Notwithstanding, further studies, meta-analysis, and prospective registries are mandatory to evaluate mid- and long-term efficacy and safety of this latest Ovation platform.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Stents/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento , Estudios Retrospectivos , Factores de Tiempo
6.
J Vasc Surg Cases Innov Tech ; 8(3): 458-461, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36016704

RESUMEN

Technical improvements and labeling updates of the AFX2 stent graft (Endologix Inc, Irvine, CA) seemed to have solved the known issues of its previous generation (AFX Strata). Although most endograft failures after endovascular abdominal aortic aneurysm repair will be managed endovascularly, a small subset of patients will still require secondary open conversion. Partial or complete endograft removal can be required, mainly dependent on the characteristics of the stent graft previously placed. We have report a case of secondary open conversion for late type Ia/IIIb endoleak due to stent fracture and fabric tear of the AFX2 stent graft 3 years after endovascular abdominal aortic aneurysm repair.

7.
Ann Vasc Surg ; 76: 342-350, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33951519

RESUMEN

BACKGROUND: Carotid artery stenting (CAS) has become a valid alternative to carotid endarterectomy in stroke prevention. However, female gender is still considered as an independent risk factor for CAS procedures, potentially limiting immediate and long-term benefits. Aim of present study was to evaluate gender differences in CAS submitted patients from an Italian high-volume center. MATERIAL AND METHODS: a retrospective monocentric study has been conducted on 568 patients (366 males and 202 females), submitted to CAS, between January 2000 and December 2019. Besides gender sex, clinical anatomical, and procedural data were collected as possible factors determining the outcome, when associated to sex gender itself. Primary endpoint of this study consisted in evaluating the technical and procedural success ratio, and the incidence of major and minor stroke, transient ischemic attack, acute myocardial infarction (AMI) peri-procedurally and at medium and long term, between the male and the female population. Secondary endpoint of this study consisted in evaluating the percentage ratio of minor complications happening peri-procedurally in both genders. RESULTS: Male patients were more likely to be octogenarians, clinical history of coronary artery disease, and smokers, while diabetes was more frequent in female patients. Anatomical and plaque morphology features were not different between the two groups. Technical success was obtained in all but two patients (99,6%), while procedural success was 95% (538/566 patients). During the peri-procedural time, no major stroke, 16 minor strokes (2,81%, 2,45% males vs. 3,45% females, P= 0,48), and 11 transient ischemic attack (2,18% males vs. 1,48% females, P= 0,56) were recorded. At a medium follow-up 57 months, 32 stroke (8 major strokes, 24 minor strokes) episodes (5,6%, males 5,7% vs. females 5,4%, P= 0,88), 24 AMIs (4,2%, males 4,6% vs. females 3,46%, P= 0,5;), 13 restenosis (2,8%, males 2,4% vs. females 1,9%, P= 0,71) and 223 deaths (39,2%, males 34,9% vs. females 47%, P= 0,0048) were noted. CONCLUSIONS: Our results showed no differences in immediate, and long-term CAS outcomes between gender. Larger, prospective studies are required to assess the real importance and significance of gender in determining CAS procedures' benefit and outcome.


Asunto(s)
Estenosis Carotídea/terapia , Procedimientos Endovasculares/instrumentación , Disparidades en el Estado de Salud , Stents , Anciano , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Ataque Isquémico Transitorio/etiología , Italia , Masculino , Infarto del Miocardio/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
8.
Int Angiol ; 40(4): 306-314, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33832186

RESUMEN

BACKGROUND: The aim of this work was to compare the diagnostic accuracy of Duplex ultrasound (DUS) and CT angiography (CTA) in the study of arterial vessels, in patients with chronic peripheral arterial disease (PAD) of the lower limbs to undergo endovascular revascularization with the use of intraprocedural digital angiography (DSA). METHODS: Ninety-four patients with obstructive pathology of the arterial axes of the lower limbs were enrolled in the study. In all patients, endovascular revascularization treatment was considered the most suitable therapeutic choice. For this reason, ultrasound and CTA was performed preoperatively in all and based on the data obtained it was decided to classify the arterial tree into five segments: iliac, common femoral, superficial femoral, popliteal and infra-geniculate. According to the degree of stenosis or occlusion, the arteries were scored in no stenotic, stenotic and occluded. The comparison of the data provided by the DUS and the CTA was carried out with reference to the parameters obtained by the DSA. RESULTS: The results of our experience have shown that in the iliac arterial district DUS proved to be less accurate than CT angiography when compared to DSA (Cohen's κ agreement of 0.91 and 1.0, respectively). Good diagnostic concordance was found in the femoro-popliteal district (Cohen's κ agreement 33 between 0.96 and 0.93). On the contrary, when the data of the infra-geniculate area were compared, CT angiography showed a net deficiency compared to DSA and DUS (Cohen's κ: 0.75). CONCLUSIONS: Due to its accuracy, high-quality DUS performed by well-trained operators may therefore represent a good alternative to CTA in patients undergoing endovascular revascularization, in order to reduce the use of contrast-enhanced radiological imaging especially when a condition of intolerance to the contrast medium and/or renal insufficiency coexists.


Asunto(s)
Enfermedad Arterial Periférica , Angiografía , Angiografía de Substracción Digital , Angiografía por Tomografía Computarizada , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Ultrasonografía Doppler Dúplex
9.
EuroIntervention ; 16(18): e1544-e1550, 2021 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-31793884

RESUMEN

AIMS: The aim of this study was to report the 30-day technical and clinical success with endovascular repair using the ultra-low-profile Ovation stent graft in patients judged to be outside the instructions for use (IFU) for conventional endografts, while amenable to treatment within the IFU for Ovation. METHODS AND RESULTS: One hundred and twenty-two patients (78.65±7.67 years; 111 male) were enrolled. Patients were evaluated as being outside the IFU for standard endografts because of the absence of a suitable proximal aortic neck in 109 cases (89.3%), of inadequate access vessels in 13 (10.7%), or both in 111 (90.9%). Mean aneurysm (abdominal aortic aneurysm [AAA]) diameter was 52.96±10.1 mm; mean aortic neck length was 7.75±6.05 mm. Technical success (98.4%) was achieved in all but two patients due to a type Ia endoleak. At completion angiography, 15 (12.3%) patients presented a type II endoleak. All patients underwent 30-day follow-up. Primary clinical success at one month was 96.8%, assisted clinical success 98.4%. There were no type I endoleaks, while 12 (9.8%) type II endoleaks were still evident, in the absence of sac expansions. Two patients (1.6%) presented an asymptomatic limb occlusion. CONCLUSIONS: Our experience suggests that, in a selected population of patients with challenging anatomy outside the IFU for conventional endografts, endovascular aneurysm repair (EVAR) using the Ovation stent graft can be performed safely with satisfactory immediate outcomes.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Humanos , Masculino , Diseño de Prótesis , Stents , Resultado del Tratamiento
10.
Ann Vasc Surg ; 67: 274-282, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32209404

RESUMEN

BACKGROUND: The aim of the present study was to evaluate early-, mid-, and long-term outcomes in an unselected population of patients treated for abdominal aortic aneurysms (AAAs) by endovascular aneurysm repair (EVAR) with different commercially available off-the-shelf devices. MATERIALS AND METHODS: A retrospective study was conducted on a prospectively compiled computerized database on patients presenting an infrarenal AAA treated between January 2008 and December 2015 in a high-volume Italian tertiary referral Center. Demographic, clinical, and specific morphological features were considered as potentially influencing the outcomes and the type of the implanted device. Outcome measures were procedure-related reintervention, AAA-related, and all-cause mortality rates at 30-day, 12-month, and long-term follow-up. Reinterventions considered for the analysis were AAA rupture, graft infection, type I or III endoleaks, type II endoleaks with sac enlargement > 5 mm, graft stenosis or occlusions, procedures related to renal or visceral ischemia, and reintervention for access vessel injury. RESULTS: Of 498 EVAR procedures performed for elective infrarenal AAA treatment during the entire study period, 479 patients were enrolled, the mean age was 73.5 ± 7.34 years (range 51-91), and 416 (86.84%) were men. The mean maximum AAA diameter was 52.02 ± 8.04 mm (range 39-90.2), a maximum AAA diameter ≥59 mm was recorded in 107 patients (22.33%), and an aortic neck length was <10 mm in 137 (28.60%). Technical success was achieved in all patients. At a mean follow-up of 52.97 ± 26.16 months (range 1-120), overall reintervention and death rates were 8.14% and 20.04%, respectively, without AAA-related deaths. At univariate analysis, hypertension was the only demographical variable found to be associated with higher risk of reintervention, P = 0.04 (OR: 2.34; CI 95%: 1.00-5.42). Furthermore, male sex (P = 0.02; OR: 2.62; CI 95%: 1.09-6.27) and chronic renal insufficiency (P = 0.003; OR: 2.08; CI 95%: 1.27-3.42) were associated with higher mortality rates. AAA diameter ≥59 mm was statistically associated with a higher rate of both reintervention and mortality: P < 0.001 (OR: 9.05; CI 95%: 4.52-18.11) and <0.001 (4.00; 2.46-6.49), respectively. CONCLUSIONS: Our experience seems to suggest that EVAR could be safely and effectively performed in an unselected patients' population, with encouraging results up to a ten-year follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Ciudad de Roma , Stents , Factores de Tiempo , Resultado del Tratamiento
11.
Ann Vasc Surg ; 53: 271.e1-271.e5, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30092428

RESUMEN

We report an unusual complication of Chocolate nitinol-constraining structure after right superficial femoral artery (SFA) angioplasty. The procedure was performed by vascular surgeons in an operating theater equipped by a portable fluoroscopy unit. Under local anesthesia, by a contralateral approach, a 7F introducer sheath was advanced through the proximal portion of the right common iliac artery. Owing to the severe aorto-iliac vessels calcification, it was not possible to place the introducer sheath into a more distal vessel, as planned. After external iliac artery (EIA) stenting (7 × 80 mm Eluvia), SFA obstruction was intraluminal crossed, and a 6 × 120 mm nitinol-constrained balloon (Chocolate; Medtronic) was advanced in place and inflated. Once the balloon came out, the nitinol-constraining structure was not attached to the balloon surface. Under fluoroscopy, the crashed nitinol mesh was identified at distal edge of previously positioned EIA stent. To prevent mesh migration, it was fixed by covering with a 7 × 40 mm stent. The procedure was then successfully completed, as planned. One-month, postoperative computed tomography angiography showed complete expansion of the stents and no significant residual stenosis (>30%) in EIA, and SFA. Chocolate's mesh was still evident between the stent and the iliac artery wall, in absence of further complications. A 3 months follow-up, patient was still completely asymptomatic for claudication.


Asunto(s)
Aleaciones , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/instrumentación , Arteria Femoral/cirugía , Arteria Ilíaca/cirugía , Enfermedad Arterial Periférica/cirugía , Stents , Anciano , Angiografía por Tomografía Computarizada , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento , Grado de Desobstrucción Vascular
12.
Cardiovasc Intervent Radiol ; 41(3): 377-384, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29159684

RESUMEN

BACKGROUND: To report our experience in treating severely claudicant patients, employing a "nitinol-constrained" balloon (Chocolate, TriReme Medical Inc., Pleasanton, CA-USA) before drug-coated balloon (DCB) in a standardized protocol. METHODS: Eighty-one (84 limbs) consecutive Rutherford category (RC) 3 patients treated between December 2014 and December 2016 for superficial femoral artery (SFA) and popliteal arterial (PA) disease by nitinol-constrained balloon followed by DCB were enrolled. Bailout stenting was performed by Zilver PTX implantation. Intraoperative technical success and bailout-stenting rates were assessed as well as clinical improvement, ankle-brachial index (ABI) modification, primary patency (PP), and secondary patency (SP) rates at follow-up. RESULTS: Sixty-eight patients (83.9%) were male and 31 (38.2%) diabetics. Fifty-five limbs (65.5%) presented occlusion (CTO); in 18 limbs CTO was longer than 150 mm. Bailout stenting rate was 9.5% (8/84). All patients completed 30-day follow-up: PP 100%, 61 patients completely asymptomatic (RC = 0). Mean follow-up was 12.3 ± 5.6 months; overall PP was 98.8%, and SP was 98.8%. At mid-term analysis, no differences in outcomes were recorded between stenosis and CTOs with a PP of 96.5 and 96%, respectively (p = 0.725). CTO length impacted early results: in cases of CTOs < 150 mm, PP was 100%, while in CTOs > 150 mm, it was 83.3% (p = 0031). ABI at 12-month was significantly higher with respect to preoperative values (p < 0.001). CONCLUSIONS: In this preliminary experience, our protocol seems to be safe and effective in treating SFA and PA lesions in claudicant patients with satisfactory early and 12-month results.


Asunto(s)
Aleaciones , Angioplastia de Balón/instrumentación , Angioplastia de Balón/métodos , Arteria Femoral/fisiopatología , Claudicación Intermitente/terapia , Arteria Poplítea/fisiopatología , Anciano , Índice Tobillo Braquial , Catéteres , Femenino , Humanos , Claudicación Intermitente/fisiopatología , Masculino , Estudios Prospectivos , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Grado de Desobstrucción Vascular/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA