Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38588571

RESUMEN

OBJECTIVES: The premise of this retrospective study was to evaluate the intraoperative use of closed-incision negative pressure therapy (ciNPT) to help reduce the incidence of postoperative sternal wound infections in multimorbid patients with an elevated risk of developing a sternal wound infection post cardiac surgery versus a cohort that received standard-of-care dressings. METHODS: Data for all adult patients were collected from each cardiothoracic surgery unit across 3 hospitals in the United Kingdom. High-risk patients had 2 or more recognized risk factors. Fisher's exact test (two-tailed) and unpaired t-test were used to help analyse categorical and continuous data. Propensity matching was performed to compare the 2 groups. RESULTS: A total of 5,288 patients who had cardiac surgery were included. Propensity matching led to 766 matched cases. There were significantly fewer sternal wound infections in the ciNPT group [43 (5.6%) vs 119 (15.5%) cases; P = 0.0001], as well as fewer deep sternal wound infections [14 (1.8%) vs 31 (4.0%) cases; P = 0.0149] and superficial sternal wound infections [29 (3.8%) vs 88 (11.4%) cases; P = 0.0001]. A higher mean length of stay in the ciNPT group was statistically significant (11.23 ± 13 vs 9.66 ± 10 days; P = 0.0083) as was a significantly higher mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) (11.143 ± 13 vs 8.094 ± 11; P = 0.0001). A statistically significant higher readmission to the intensive care unit due to sternal wound infection was noted for the controls [16 (2.08%) vs 3 (0.39%) readmissions; P = 0.0042]. CONCLUSIONS: The ciNPT appears to be an effective intervention to help reduce the incidence of sternal wound infection in high-risk individuals undergoing cardiac surgery.

2.
J Clin Med ; 13(8)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38673461

RESUMEN

Background: Introduced in the latest BCLC 2022, endovascular trans-arterial radioembolization (TARE) has an important role in the treatment of unresectable hepatocellular carcinoma (HCC) as a "bridge" or "downstaging" of disease. The evolution of TARE technology allows a more flexible and personalized target treatment, based on the anatomy and vascular characteristics of each HCC. The flex-dose delivery program is part of this perspective, which allows us to adjust the dose and its radio-embolizing power in relation to the size and type of cancer and to split the therapeutic dose of Y90 in different injections (split-bolus). Methods: From January 2020 to January 2022, we enrolled 19 patients affected by unresectable HCC and candidates for TARE treatment. Thirteen patients completed the treatment following the flex-dose delivery program. Response to treatment was assessed using the mRECIST criteria with CT performed 6 and 9 months after treatment. Two patients did not complete the radiological follow-up and were not included in this retrospective study. The final cohort of this study counts eleven patients. Results: According to mRECIST criteria, six months of follow-up were reported: five cases of complete response (CR, 45.4% of cases), four cases of partial response (PR, 36.4%), and two cases of progression disease (PD, 18.2%). Nine months follow-up reported five cases of complete response (CR, 45.4%), two cases of partial response (PR, 18.2%), and four cases of progression disease (PD, 36.4%). No intra and post-operative complications were described. The average absorbed doses to the hepatic lesion and to the healthy liver tissue were 319 Gy (range 133-447 Gy) and 9.5 Gy (range 2-19 Gy), respectively. Conclusions: The flex-dose delivery program represents a therapeutic protocol capable of "saving" portions of healthy liver parenchyma by designing a "custom-made" treatment for the patient.

4.
Eur Radiol ; 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38127075

RESUMEN

OBJECTIVES: To assess the incidence (1 year) and the cumulative incidence (3 years) of the condition of patients accruing cumulative effective doses (CED) of ≥ 100 mSv and their variability among different hospitals. To establish and validate a reference level for the CED in patients with recurrent exposures (RERL) and provide a RERL value. METHODS: Data of CT exposure was collected in 9 similar hospitals. The database included 294,222 patient*years who underwent 442,278 CT exams in 3 years. The incidence proportion of patients with CED ≥ 100 mSv in a given year (I100;1) and the 3-year cumulative incidence of patients with CED ≥ 100 mSv over 3 consecutive years (I100;3) were calculated and compared among different institutions. RESULTS: I100;1 ranged from a minimum of 0.1% to a maximum of 5.1%. The percentage of recurrent patients was quite uniform among centres ranging from 23 to 38%. The I100;3 ranged from a minimum of 1.1 to 11.4%. There was a strong positive correlation between the third quartile values of yearly CED and yearly incidence (r = 0.90; R2 = 0.81; p < 0.0001). RERL value in our study was found at 34.0 mSv. CONCLUSION: The management of patients with recurrent exposures is highly variable among hospitals leading to a 50-fold variation in I100;1 and to a tenfold variation in I100;3. RERL could be established and used by taking as a RERL quantity the CED and as a RERL value the 75th percentile of the third quartiles of the distribution of the yearly CED obtained by surveying different hospitals. CLINICAL RELEVANCE STATEMENT: This is the first ever multicentre study that quantifies recurrent exposures in terms of incidence and cumulative incidence of patients with CED ≥ 100 mSv. RERL establishment and use could benefit the optimisation of radioprotection of patients with recurrent exposures. KEY POINTS: This is the first multicentre study estimating yearly incidence and 3-year cumulative incidence of patients with cumulative effective doses ≥ 100 mSv. In this study, a 50-fold inter centre variation between the maximum (5.1%) and the minimum value (0.1%) of yearly incidence of patients with cumulative effective doses ≥ 100 mSv was reported. The range of the 3-year cumulative incidence extended from 1.1 to 11.4% (a tenfold variation) The third quartile of the yearly cumulative effective doses in a centre showed a strong positive correlation with the yearly incidence of patients with cumulative effective doses ≥ 100 mSv, with a potential of being used to set reference levels for recurrent exposures.

5.
Cancers (Basel) ; 15(18)2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37760562

RESUMEN

(1) Background: Venous thromboembolism (VTE) is a frequent complication in ambulatory lung cancer patients during chemotherapy and is associated with increased mortality. (2) Methods: We analyzed 568 newly diagnosed metastatic lung cancer patients prospectively enrolled in the HYPERCAN study. Blood samples collected before chemotherapy were tested for thrombin generation (TG) and a panel of hemostatic biomarkers. The Khorana risk score (KRS), new-Vienna CATS, PROTECHT, and CONKO risk assessment models (RAMs) were applied. (3) Results: Within 6 months, the cumulative incidences of VTE and mortality were 12% and 29%, respectively. Patients with VTE showed significantly increased levels of D-dimer, FVIII, prothrombin fragment 1 + 2, and TG. D-dimer and ECOG performance status were identified as independent risk factors for VTE and mortality by multivariable analysis and utilized to generate a risk score that provided a cumulative incidence of VTE of 6% vs. 25%, death of 19% vs. 55%, and in the low- vs. high-risk group, respectively (p < 0.001). While all published RAMs significantly stratified patients for risk of death, only the CATS and CONKO were able to stratify patients for VTE. (4) Conclusions: A new prediction model was generated to stratify lung cancer patients for VTE and mortality risk, where other published RAMs failed.

6.
EClinicalMedicine ; 64: 102194, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37731937

RESUMEN

Background: The optimal duration of anticoagulation in patients with active cancer and venous thromboembolism (VTE) is unknown. Current clinical guidelines advocate anticoagulant therapy for 3-6 months and to continue anticoagulant therapy for as long as the cancer is active. However, an adequate systematic review on the rate of recurrent VTE after discontinuation of anticoagulant therapy has not been performed. Methods: For this systemic review and meta-analysis, we searched Embase.com, Medline (Ovid), Web of Science, Cochrane Library, and Google Scholar, from database inception to February 16, 2023, for studies on anticoagulant therapy in patients with cancer and the recurrence of venous thromboembolism after discontinuation of this therapy. We included randomised controlled trials and cohort studies published in English that reported on patients who met the following: cancer and a first VTE, completed at least 3 months of anticoagulant therapy, were followed after discontinuation of anticoagulant therapy, and with symptomatic recurrent VTE as an outcome during follow-up. Study-level data were requested from study authors. The primary outcome was the rate of recurrent VTE after discontinuation of anticoagulant therapy. A Bayesian random-effects meta-analysis was used to estimate the rate of recurrent VTE per 100 person-years for the pooled studies at different time intervals after discontinuation of anticoagulation therapy. We also calculated the cumulative VTE recurrence rate at different time intervals. Forest plots were mapped and the results were summarized by the median and 95% credible interval (CIs). This study was registered with PROSPERO, CRD42021249060. Findings: Of 3856 studies identified in our search, 33 studies were identified for inclusion. After requesting study-level data, 14 studies involving 1922 patients with cancer-associated thrombosis were included. The pooled rate of recurrent VTE per 100 person-years after discontinuation of anticoagulant therapy was 14.6 events (95% credible interval 6.5-22.8) in the first three months, decreasing to 1.1 events (95% CI 0.3-2.1) in year 2-3, and 2.2 events (95% CI 0.0-4.4) in year 3-5 after discontinuation of anticoagulant therapy. The cumulative VTE recurrence rate was 28.3% (95% CI 15.6-39.6%) at 1 year; 31.1% (95% CI 16.5-43.8%) at 2 years; 31.9% (95% CI 16.8-45.0%) at 3 years; and 35.0% (95% CI 16.8-47.4%) at 5 years after discontinuation of anticoagulant therapy. Interpretation: This meta-analysis demonstrates a high rate of recurrent VTE over time after discontinuation of anticoagulant therapy in patients with cancer-associated thrombosis. Our results support the current clinical guidelines to continue anticoagulant therapy in patients with active cancer. Funding: Erasmus MC.

7.
J Dermatolog Treat ; 34(1): 2230685, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37400981

RESUMEN

OBJECTIVES: The purpose of this study was to analyze the drug survival rate of dupilumab up to 2 years in a large real-world cohort of adult patients affected by moderate/severe atopic dermatitis (AD), and to investigate the clinical, demographic and predictive factors influencing the patients' treatment persistence. MATERIAL AND METHODS: This study included adult patients affected by moderate-to-severe AD treated with dupilumab for at least 16 weeks who visited 7 dermatologic outpatient clinics in Lazio, Italy, from January 2019 until August 2021. RESULTS: A total of 659 adult patients (345 male [52.3%], mean age: 42.8 years) with an average treatment duration of 23.3 months were enrolled in the study. Overall, 88.6% and 76.1% of patients were still on treatment after 12 and 24 months, respectively. The drug survival rate for discontinuation due to AEs and dupilumab ineffectiveness was 95.0% at 12 months and 90.0% at 24 months. The main reasons for drug discontinuation included inefficacy (29.6%), failed compliance (17.4%), persistent efficacy (20.4%) and adverse events (7.8%). Adult AD onset (≥18 years) and EASI score severity measured at the last follow-up visit were the only factors significantly associated with lower drug survival. CONCLUSION: This study revealed an increased cumulative probability of dupilumab survival at 2 years, reflected by a sustained effectiveness and a favorable safety profile of the drug.


Asunto(s)
Dermatitis Atópica , Humanos , Adulto , Masculino , Dermatitis Atópica/tratamiento farmacológico , Resultado del Tratamiento , Índice de Severidad de la Enfermedad , Anticuerpos Monoclonales Humanizados/efectos adversos , Método Doble Ciego
8.
Br J Radiol ; 96(1149): 20230106, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37493259

RESUMEN

OBJECTIVE: To assess the cumulated exposure to radiation due to imaging in Hodgkin (HL) and diffuse large B-cell (DLBCL) lymphoma patients who were not submitted to radiotherapy. METHODS: The study population included 51 and 83 adult patients with HL and DLBCL, with a follow-up duration >1 year. The cumulated exposure was expressed using patient-specific data as cumulated effective dose (CED). RESULTS: Fifty-one HL patients (median age 47 years) were followed for a median of 3.5 years. The median total CED per subject was 104 mSv. CT and PET/CT examinations accounted for 75 and 25% of the total CED, respectively. 26 patients (49%) had a total CED ≥ 100 mSv and the maximum CED was 302 mSv. Eighty-three DLBCL patients (median age 66 years) were followed for a median of 3.7 years. The median total CED per subject over the study period was 134 mSv. CT and PET/CT for 86% and 13% of the total CED, respectively. 56 patients (67%) had a total CED ≥100 mSv. The maximum CED was 557 mSv. CONCLUSION: Our study demonstrated the large number of imaging procedures performed for patients with lymphoma. Overall, 61% of the patients accrued a CED ≥ 100 mSv. Imaging policies were only in a partial agreement with current international guidelines. ADVANCES IN KNOWLEDGE: The cumulated exposure radiation exposure may be of concern in HL patients and the contribution of CT procedures to the total CED is significant. The standardisation of clinical guidelines for managing patients with lymphoma is warranted.


Asunto(s)
Linfoma de Células B Grandes Difuso , Exposición a la Radiación , Adulto , Humanos , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Dosis de Radiación , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Linfoma de Células B Grandes Difuso/radioterapia
9.
Phys Med ; 110: 102603, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37178623

RESUMEN

PURPOSE: To assess occupational eye lens dose based on clinical monitoring of interventional radiologists and to assess personal protective eyewear (PPE) efficacy through measurements with anthropomorphic phantom. METHODS: Two positions of the operator with respect to X-ray beam were simulated with phantom. Dose reduction factor (DRF) of four PPE was assessed, as well as correlation between eye lens and whole-body doses. Brain dose was also assessed. Five radiologists were monitored for one-year clinical procedures. All subjects were equipped with whole-body dosimeter placed over lead apron at the chest level and eye lens dosimeter placed over the left side of the PPE. Kerma-Area Product (KAP) of procedures performed during the monitoring period was recorded. The correlation of eye lens dose with whole-body dose and KAP was assessed. RESULTS: DRF was 4.3/2.4 for wraparound glasses, 4.8/1.9 for fitover glasses, 9.1/6.8 for full-face visor in radial/femoral geometries. DRF of half-face visor depended on how it is worn (range 1.0-4.9). Statistically significant correlation between dose value over the PPE and chest dose was observed, while there was no correlation between eye lens dose and chest dose. The results on clinical staff showed statistically significant correlation between dose values over the PPE and KAP. CONCLUSIONS: All PPE showed significant DRF in all configurations, provided they were worn correctly. Single DRF value is not applicable to all clinical situations. KAP is a valuable tool for determining appropriate radiation protection measures.


Asunto(s)
Cristalino , Exposición Profesional , Exposición a la Radiación , Protección Radiológica , Humanos , Radiología Intervencionista/métodos , Dosis de Radiación , Dispositivos de Protección de los Ojos , Protección Radiológica/métodos , Exposición Profesional/prevención & control , Exposición Profesional/análisis , Exposición a la Radiación/prevención & control
10.
Phys Med ; 109: 102584, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37060633

RESUMEN

PURPOSE: To study how the quantitative parameters of 18F-FDG PET imaging change with the emission scan duration (ESD) and the body-mass-index (BMI) in phantom and patients on a time-of-flight (TOF)-PET/CT system. METHODS: The image-quality phantom with (b-NEMA-IQ, BMI = 29.2 kg/m2) and without (NEMA-IEC, BMI = 21.4 kg/m2) a 'belt' of water-bags was filled with 18F-FDG activities to obtain nominal standardized uptake values (SUV) of 19, 8 and 5. Patients with BMI ≤ 25 kg/m2 (L-BMI) and BMI > 25 kg/m2 (H-BMI) were enrolled in this study. Phantom and patients underwent list-mode PET acquisition at 120 s/bed-position. Images reconstructed with clinical protocol and different ESD (120, 90, 75, 60, 45, 30 s) were analysed for comparison of maximum SUV (SUVmax), maximum standardized uptake value lean-body-mass corrected (SULmax) and noise. RESULTS: 79 oncologic patients (45 L-BMI, 44 H-BMI) were analysed. From 90 s to 30 s, an increasing variation of SUVmax and SULmax with respect to the reference 120 s time was observed, from 18% to 60% and from 16% to 37% for phantom and patients, respectively. SUVmax values were significantly higher (+50%) in b-NEMA-IQ than NEMA-IQ phantom and in H-BMI (+33%) than L-BMI patients. No significant difference was found in SULmax for the two BMI categories in both phantom and patients. CV values decreased when increasing ESD, being higher in H-BMI patients (0.13-0.25) and b-NEMA-IQ phantom (0.15-0.28) than in L-BMI patients (0.11-0.21) and NEMA-IQ phantom (0.11-0.20). CONCLUSIONS: Reduction of ESD may severely impact on the variations of SUVmax and SULmax in 18F-FDG PET/CT imaging. This study confirms recommendations of using SUL for lesion uptake quantification, being unaffected by BMI variation.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Fantasmas de Imagen , Índice de Masa Corporal
11.
Monaldi Arch Chest Dis ; 94(1)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37074089

RESUMEN

This study sought to compare the morbidity and mortality of redo aortic valve replacement (redo-AVR) versus valve-in-valve trans-catheter aortic valve implantation (valve-in-valve TAVI) for patients with a failing bioprosthetic valve. A multicenter UK retrospective study of redo-AVR or valve-in-valve TAVI for patients referred for redo aortic valve intervention due to a degenerated aortic bioprosthesis. Propensity score matching was performed for confounding factors. From July 2005 to April 2021, 911 patients underwent redo-AVR and 411 patients underwent valve-in-valve TAVI. There were 125 pairs for analysis after propensity score matching. The mean age was 75.2±8.5 years. In-hospital mortality was 7.2% (n=9) for redo-AVR versus 0 for valve-in-valve TAVI, p=0.002. Surgical patients suffered more post-operative complications, including intra-aortic balloon pump support (p=0.02), early re-operation (p<0.001), arrhythmias (p<0.001), respiratory and neurological complications (p=0.02 and p=0.03) and multi-organ failure (p=0.01). The valve-in-valve TAVI group had a shorter intensive care unit and hospital stay (p<0.001 for both). However, moderate aortic regurgitation at discharge and higher post-procedural gradients were more common after valve-in-valve TAVI (p<0.001 for both). Survival probabilities in patients who were successfully discharged from the hospital were similar after valve-in-valve TAVI and redo-AVR over the 6-year follow-up (log-rank p=0.26). In elderly patients with a degenerated aortic bioprosthesis, valve-in-valve TAVI provides better early outcomes as opposed to redo-AVR, although there was no difference in mid-term survival in patients successfully discharged from the hospital.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Reino Unido/epidemiología , Resultado del Tratamiento , Factores de Riesgo , Bioprótesis/efectos adversos
12.
J Thromb Haemost ; 21(7): 1869-1881, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37054917

RESUMEN

BACKGROUND: Risk assessment models (RAMs) are relevant approaches to identify cancer outpatients at high risk of venous thromboembolism (VTE). Among the proposed RAMs, the Khorana (KRS) and the new-Vienna CATS risk scores have been externally validated in ambulatory patients with cancer. OBJECTIVES: To test KRS and new-Vienna CATS scores in 6-month VTE prediction and mortality in a large prospective cohort of metastatic cancer outpatients during chemotherapy. PATIENTS/METHODS: Newly diagnosed patients with metastatic non-small cell lung, colorectal, gastric, or breast cancers were analyzed (n = 1286). The cumulative incidence of objectively confirmed VTE was estimated with death as a competing risk and multivariate Fine and Gray regression. RESULTS: Within 6 months, 120 VTE events (9.7%) occurred. The KRS and the new-Vienna CATS scores showed comparable c-stat. Stratification by KRS provided VTE cumulative incidences of 6.2%, 11.4%, and 11.5% in the low-, intermediate-, and high-risk categories, respectively (p = ns), and of 8.5% vs. 11.8% (p = ns) in the low- vs. high-risk group by the single 2-point cut-off value stratification. Using a pre-defined 60-point cut-off by the new-Vienna CATS score, 6.6% and 12.2% cumulative incidences were obtained in the low- and high-risk groups, respectively (p < 0.001). Furthermore, having a KRS ≥2 = or a new-Vienna CATS score >60 points was also an independent risk factor for mortality. CONCLUSION: In our cohort, the 2 RAMs showed a comparable discriminating potential; however, after the application of cut-off values, the new-Vienna CATS score provided statistically significant stratification for VTE. Both RAMs proved to be effective in identifying patients at increased risk of mortality.


Asunto(s)
Neoplasias , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/epidemiología , Tromboembolia Venosa/etiología , Estudios Prospectivos , Estudios Retrospectivos , Neoplasias/diagnóstico , Neoplasias/tratamiento farmacológico , Neoplasias/complicaciones , Factores de Riesgo , Medición de Riesgo
13.
Respirol Case Rep ; 11(4): e01113, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36910130

RESUMEN

Pulmonary Peripheral Lesions (PPLs) diagnosis is usually performed using a guidance system in combination with bronchoscopes and diagnostic tools. We report two cases of PPLs sampling procedures combining the use of the single-use bronchoscope Ambu aScope 5 Broncho and CIOS 3D Spin Mobile (Siemens Healthineers) fluoroscopy system. A 69-year-old-female was found to have a lesion located in right B6 segment and a 73-year-old-male with a mass in the upper right lobe. We used for both cases a single-use bronchoscope to reach the correct area and the fluoroscopy system to guide peripheral transbronchial aspiration needle (TBNA) sampling. After the confirmation of the correct location of the TBNA tool, the sampling was performed. Rapid onsite evaluation (ROSE) confirmed the adequacy of the sample for molecular analysis and the final diagnosis. Thus, the use of ever-new disposable bronchoscopes for sampling peripheral lesions is a viable alternative to reusable bronchoscopes for advanced bronchoscopy procedures.

14.
Cancers (Basel) ; 14(18)2022 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-36139507

RESUMEN

Background: the tight and reciprocal interaction between cancer and hemostasis has stimulated investigations on the possible role of hemostatic biomarkers in predicting specific cancer outcomes, such as disease progression (DP) and overall survival (OS). In a prospective cohort of newly diagnosed metastatic gastrointestinal (GI) cancer patients from the HYPERCAN study, we aimed to assess whether the hemostatic biomarker levels measured before starting any anticancer therapy may specifically predict for 6-months DP (6m-DP) and for 1-year OS (1y OS). Methods: plasma samples were collected and tested for thrombin generation (TG) as global hemostatic assay, and for D-dimer, fibrinogen, and prothrombin fragment 1 + 2 as hypercoagulation biomarkers. DP and mortality were monitored during follow-up. Results: A prospective cohort of 462 colorectal and 164 gastric cancer patients was available for analysis. After 6 months, DP occurred in 148 patients, providing a cumulative incidence of 24.8% (21.4−28.4). D-dimer and TG endogenous thrombin potential (ETP) were identified as independent risk factors for 6m-DP by multivariate Fine−Gray proportional hazard regression model corrected for age, cancer site, and >1 metastatic site. After 1 year, we observed an OS of 75.7% (71.9−79.0). Multivariate Cox regression analysis corrected for age, site of cancer, and performance status identified D-dimer and ETP as independent risk factors for 1y OS. Patients with one or both hemostatic parameters above the dichotomizing threshold were at higher risk for both 6m-DP and 1-year mortality. Conclusion.: in newly diagnosed metastatic GI cancer patients, pretreatment ETP and D-dimer appear promising candidate biomarkers for predicting 6m-DP and 1y OS. In this setting, for the first time, the role of TG as a prognostic biomarker emerges in a large prospective cohort.

15.
Front Cardiovasc Med ; 9: 896362, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757331

RESUMEN

Introduction: In a prospective cohort of hospitalized COVID-19 patients, an extensive characterization of hemostatic alterations by both global and specific assays was performed to clarify mechanisms underlying the coagulopathy and identify predictive factors for thrombotic and hemorrhagic events during hospitalization. Materials and Methods: Intensive care unit (ICU; n = 46) and non-ICU (n = 55) patients were enrolled, and the occurrence of thrombotic and hemorrhagic events was prospectively monitored. At study inclusion, thromboelastometry together with the measurement of specific coagulation proteins and hypercoagulation markers was performed. Results: Patients (median age 67 years) showed significantly shorter clot formation time together with greater maximum clot firmness by thromboelastometry, increased levels of F1 + 2 and D-dimer, as biomarkers of hypercoagulability, and of procoagulant factors V, VIII, IX, XI, and fibrinogen, while FXIII was significantly reduced. The concentration of fibrinolytic proteins, tissue plasminogen activator (t-PA) and plasminogen activator inhibitor type 1 (PAI-1) were elevated in the overall cohort of patients. Many of these hemostatic alterations were significantly greater in ICU compared to non-ICU subjects and, furthermore, they were associated with inflammatory biomarker elevation [i.e., interleukin 6 (IL-6), C-reactive protein (CRP), neutrophil to lymphocyte ratio (NLR), and procalcitonin]. After enrollment, 7 thrombosis and 14 major bleedings occurred. Analysis of clinical and biological data identified increased t-PA, PAI-1, and NLR values as independent predictive factors for thrombosis, while lower FXIII levels were associated with bleeding. Conclusion: This study demonstrates alterations in all different hemostatic compartments analyzed, particularly in severe COVID-19 conditions, that strongly correlated with the inflammatory status. A potential role of fibrinolytic proteins together with NLR and of FXIII as predictors of thrombotic and hemorrhagic complications, respectively, is highlighted.

16.
Phys Med Biol ; 67(6)2022 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-35176728

RESUMEN

The aim of this systematic review is to undertake a critical appraisal of the evidence in the published literature concerning the conversion factors between kerma-area product (PKA) and effective/organ dose (DCED_PKA, DCHT_PKA) for cardiac interventional fluoroscopy procedures performed in adults and paediatric patients and to propose reference conversion factors to help standardize dose calculations. A search strategy utilizing MeSH headings in three databases identified 59 (adult) and 37 (paediatric) papers deemed eligible for the review. Exclusion criteria were adopted to select data only from publications which established DCED_PKAin patients using the ICRP 103 tissue weighting factors. A time restriction from January 2007 was introduced in the search to capture the evolving trends of utilization of fluoroscopy-guided intervention technologies only in recent years. The suggested DCED_PKAand DCHT_PKAwere synthesized by calculating the weighted averages of the values reported by the authors with weights corresponding to the study sample size. Eighteen studies for both adult (9) and paediatric (9) patients matching the search terms fulfilled the inclusion criteria. The suggested value for DCED_PKAin adult patients amounts to 0.24 mSv Gy-1cm-2. The suggested values for DCHT_PKAranged from a minimum of 0.15 mSv Gy-1cm-2for the female breast to a maximum of 0.97 mSv Gy-1cm-2for the lungs. The suggested values for DCED_PKAin paediatric patients ranged from 3.45 mSv Gy-1cm-2for the new-born to 0.49 mSv Gy-1cm-2in the 15 years age class. The suggested values for DCHT_PKAranged from a minimum of 0.33 mSv Gy-1cm-2for bone marrow in the 15 years age class to a maximum of 11.49 mSv Gy-1cm-2for the heart in the new-born. To conclude, values of DCED_PKA/DCHT_PKAwere provided for calculating effective/organ doses in cardiac interventional procedures. They can be useful for standardizing dose calculations, hence for comparison of the radiation detriment from different imaging procedures and in the framework of epidemiologic studies.


Asunto(s)
Corazón , Tecnología , Adulto , Niño , Bases de Datos Factuales , Femenino , Fluoroscopía , Corazón/diagnóstico por imagen , Humanos , Tamaño de la Muestra
17.
Interact Cardiovasc Thorac Surg ; 34(6): 974-981, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34718571

RESUMEN

OBJECTIVES: We evaluated graft patency by computed tomography and explored the determinants of intraoperative mean graft flow (MGF) and its contribution to predict early graft occlusion. METHODS: One hundred and forty-eight patients under a single surgeon were prospectively enrolled. Arterial and endoscopically harvested venous conduits were used. Intraoperative graft characteristics and flows were collected. Graft patency was blindly evaluated by a follow-up computed tomography at 11.4 weeks (median). RESULTS: Graft occlusion rate was 5.2% (n = 22 of 422; 8% venous and 3% arterial). Thirteen were performed on non-significant proximal stenosis while 9 on occluded or >70% stenosed arteries. Arterial and venous graft MGF were lower in females (Parterial = 0.010, Pvenous = 0.009), with median differences of 10 and 13.5 ml/min, respectively. Arterial and venous MGF were associated positively with target vessel diameter ≥1.75 mm (Parterial = 0.025; Pvenous = 0.002) and negatively with pulsatility index (Parterial < 0.001; Pvenous < 0.001). MGF was an independent predictor of graft occlusion, adjusting for EuroSCORE-II, pulsatility index, graft size and graft type (arterial/venous). An MGF cut-off of 26.5 ml/min for arterial (sensitivity 83.3%, specificity 80%) and 36.5 ml/min for venous grafts (sensitivity 75%, specificity 62%) performed well in predicting early graft occlusion. CONCLUSIONS: We demonstrate that MGF absolute values are influenced by coronary size, gender and graft type. Intraoperative MGF of >26.5 ml/min for arterial and >36.5 ml/min for venous grafts is the most reliable independent predictor of early graft patency. Modern-era coronary artery bypass graft is associated with low early graft failure rates when transit time flow measurement is used to provide effective intraoperative quality assurance.


Asunto(s)
Puente de Arteria Coronaria , Tomografía Computarizada por Rayos X , Arterias , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Femenino , Humanos , Grado de Desobstrucción Vascular
18.
World J Gastroenterol ; 27(37): 6180-6190, 2021 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-34712026

RESUMEN

Surveillance for hepatocellular carcinoma (HCC) in high-risk patients with semiannual ultrasound examinations is advocated by all international guidelines. However, as long as the identification of the population to be screened and the surveillance programs are not well implemented, the real-life impact of HCC surveillance in reducing mortality for HCC cannot be known. We propose a new approach that promotes the identification of cirrhotic patients by primary care physicians (PCPs) and referral of patients to the hepatologist for surveillance. Surveillance should be incorporated, when feasible, in a hub and spoke model of comprehensive hepatology care. Training PCPs to identify cirrhotic patients and performing surveillance in a subspecialist setting are equally important to improve the effectiveness of real-life surveillance and to decrease HCC mortality over time.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Médicos de Atención Primaria , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/epidemiología , Humanos , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/epidemiología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/epidemiología , Vigilancia de la Población , Ultrasonografía
19.
Curr Res Immunol ; 2: 155-162, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34545350

RESUMEN

Early prediction of COVID-19 in-hospital mortality relies usually on patients' preexisting comorbidities and is rarely reproducible in independent cohorts. We wanted to compare the role of routinely measured biomarkers of immunity, inflammation, and cellular damage with preexisting comorbidities in eight different machine-learning models to predict mortality, and evaluate their performance in an independent population. We recruited and followed-up consecutive adult patients with SARS-Cov-2 infection in two different Italian hospitals. We predicted 60-day mortality in one cohort (development dataset, n = 299 patients, of which 80% was allocated to the development dataset and 20% to the training set) and retested the models in the second cohort (external validation dataset, n = 402). Demographic, clinical, and laboratory features at admission, treatments and disease outcomes were significantly different between the two cohorts. Notably, significant differences were observed for %lymphocytes (p < 0.05), international-normalized-ratio (p < 0.01), platelets, alanine-aminotransferase, creatinine (all p < 0.001). The primary outcome (60-day mortality) was 29.10% (n = 87) in the development dataset, and 39.55% (n = 159) in the external validation dataset. The performance of the 8 tested models on the external validation dataset were similar to that of the holdout test dataset, indicating that the models capture the key predictors of mortality. The shap analysis in both datasets showed that age, immune features (%lymphocytes, platelets) and LDH substantially impacted on all models' predictions, while creatinine and CRP varied among the different models. The model with the better performance was model 8 (60-day mortality AUROC 0.83 ± 0.06 in holdout test set, 0.79 ± 0.02 in external validation dataset). The features that had the greatest impact on this model's prediction were age, LDH, platelets, and %lymphocytes, more than comorbidities or inflammation markers, and these findings were highly consistent in both datasets, likely reflecting the virus effect at the very beginning of the disease.

20.
BMC Infect Dis ; 21(1): 811, 2021 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-34388982

RESUMEN

BACKGROUND: Hemophagocytic syndrome (HPS) is a severe hyperinflammatory disease, whose diagnosis is based on the HLH-2004 criteria. In secondary forms of HLH (sHLH), the primary goal is treating the triggering factors such as COVID-19 (Coronavirus disease 2019). The link between the cytokine storm related to COVID-19 and development of sHLH has already been reported since the onset of pandemic, but little is known about clinical manifestations of HLH which develop after the patient's recovery from mild symptomatic or asymptomatic Sars-CoV-2 infection. CASE PRESENTATION: We describe the case of a woman diagnosed with sHLH related to previous Sars-CoV-2 infection and successfully treated with steroids, colchicine, etoposide and ruxolitinib. CONCLUSIONS: Our report suggests that HLH-like syndrome might be secondary to Sars-CoV-2 infection, even if the patient utterly recovered from the mildly symptomatic viral infection. In addition, we underline the treatment with low dose ruxolitinib plus etoposide as a potential choice for Sars-CoV-2 infection related HLH.


Asunto(s)
COVID-19/complicaciones , Síndrome de Liberación de Citoquinas/diagnóstico , Linfohistiocitosis Hemofagocítica/diagnóstico , COVID-19/diagnóstico , Síndrome de Liberación de Citoquinas/etiología , Femenino , Humanos , Linfohistiocitosis Hemofagocítica/complicaciones , Linfohistiocitosis Hemofagocítica/tratamiento farmacológico , Linfohistiocitosis Hemofagocítica/etiología , Persona de Mediana Edad , Pandemias , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...