Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Orthop Rev (Pavia) ; 14(6): 38576, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36267219

RESUMEN

Background: Femoral neck fractures (FNF) are associated to patient's disability, reduced quality of life and mortality. None of the fixation devices commonly used for extracapsular (EC) FNF (i.e., dynamic hip screws (DHS) and intramedullary nails (IN)) is clearly superior to the other, especially in case of unstable fractures (31.A2 and 31.A3 according to AO/OTA classification). The aim of our study was to identify a sub-population of patients with EC fractures in which better outcomes could be obtainable using total hip arthroplasty (THA). Methods: All patients with EC unstable fractures treated with THA were included in the present study. Demographic data, American Society of Anesthesiologists (ASA) score, hospitalization length, transfusion rate, implant-related complications and mortality rate were collected. Clinical outcomes were evaluated using the Oxford Hip Score (OHS), while patients' general health status through the 12 Item Short Form questionnaires (SF-12). Results: 30 patients (7 male; 23 female) with a mean age of 78.8 years were included. The 1-year mortality rate was 13.3%. The mean OHS was 27.5, while the mean SF-12 were 45.84 for the mental item and 41.6 for the physical one. Age was the only factor associated with the OHS and patients older than 75 years presented a 12- fold higher risk of developing bad outcomes. Conclusions: THA seems to be a viable option for unstable EC fractures, with good clinical outcomes, especially in patients younger than 75 years of age. The mortality rate associated with THA in EC fractures is low and anyway comparable with IN.

2.
J Vasc Access ; 21(6): 868-874, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32126883

RESUMEN

INTRODUCTION: In the literature, the change of a syringe pump is described as a dangerous situation, especially in the case of vasoactive drug administration. METHODS: Different variables have been studied (central venous pressure, pump displacement in relation to the patient position, utilization of a stopcock, or a neutral displacement needle-free connector between the syringe and the infusion tubing) to understand their influence on medication administration in terms of backflow or bolus creation when changing the syringe. RESULTS: We performed 576 measurements with different combinations. With respect to all the observations, in comparison with "time zero," we found the following differences expressed in microliters: 0 (±1) at the plunger opening; 0 (±3) at the syringe extraction from the pump; 0 (±7) at the syringe disconnection from the infusion tubing; 0 (±11) at the syringe reconnection to the infusion tubing; 1 (±7) at the syringe insertion in the pump; 3 (±23) at the plunger closing; 8 (±33) at the stabilization at the maneuver end. CONCLUSION: The syringe change can be a very critical moment given different influencing variables. Syringe pump position, displaced higher than the patient level, always generates a medication bolus that is higher at the lowering of the central venous pressure value. The presence of a neutral displacement needle-free connector reduces the incidence of boluses. When the pump is placed at the patient level, the presence of neutral displacement needle-free connector reduces the establishment of boluses, even in a central venous pressure of -5 mmHg simulations.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad Crítica/terapia , Sistemas de Liberación de Medicamentos/instrumentación , Bombas de Infusión Implantables , Jeringas , Diseño de Equipo , Humanos , Infusiones Parenterales , Ensayo de Materiales , Presión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA