Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Dent ; 147: 105080, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38788919

RESUMEN

OBJECTIVES: To evaluate the influence of dentin moisture on the clinical behavior of a universal adhesive on posterior teeth after 36 months of follow-up. METHODS: Forty-five patients participated in this study. Following a split-mouth design, three operators placed 90 Class I/Class II restorations over moist dentin (MD) or dry (DD) (n = 45) with resin composite (Filtek Bulk Fill) and a universal adhesive used in the etch-and-rinse mode (Single Bond Universal). Each restoration was evaluated according to the FDI and USPHS criteria (postoperative sensitivity, fracture and retention, marginal staining, marginal adaptation, and recurrence of caries) at baseline and after 6-, 12-, and 36 months. For statistical analysis, Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used. RESULTS: No significant difference between groups was observed in each FDI criterion after 36 months of clinical evaluation (p > 0.05). The retention rates (confidence interval 95 %) were 97.37 % (86.5 - 99.5) for both MD and DD without significant difference between them (p > 0.05). Eight restorations (MD = 4; DD = 4) showed minimal marginal staining defects (p > 0.05). Two restorations were lost (MD = 1; DD = 1). Fifteen restorations (MD = 8; DD = 7) presented minor marginal discrepancies according to the FDI criteria (p > 0.05). CONCLUSION: The clinical performance of the universal adhesive when applied in etch-and-rinse mode was not influenced by dentin moisture in posterior bulk-fill composite restorations. CLINICAL SIGNIFICANCE: The level of dentin moisture appears not to influence the clinical efficacy of a universal adhesive when applied using the etch-and-rinse technique in posterior composite resin restorations.


Asunto(s)
Bisfenol A Glicidil Metacrilato , Resinas Compuestas , Caries Dental , Adaptación Marginal Dental , Fracaso de la Restauración Dental , Restauración Dental Permanente , Sensibilidad de la Dentina , Recubrimientos Dentinarios , Dentina , Cementos de Resina , Humanos , Restauración Dental Permanente/métodos , Resinas Compuestas/química , Resinas Compuestas/uso terapéutico , Femenino , Masculino , Método Doble Ciego , Adulto , Cementos de Resina/química , Persona de Mediana Edad , Bisfenol A Glicidil Metacrilato/química , Bisfenol A Glicidil Metacrilato/uso terapéutico , Caries Dental/terapia , Recubrimientos Dentinarios/química , Recubrimientos Dentinarios/uso terapéutico , Estudios de Seguimiento , Adulto Joven , Resultado del Tratamiento , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental
2.
Dent Mater ; 40(4): 619-628, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38369403

RESUMEN

OBJECTIVES: To evaluate the clinical performance of posterior restorations over wet and dry dentin with an etch-and-rinse adhesive after 36 months of clinical service. METHODS: Forty-five participants were recruited, each one had at least two posterior teeth that needed restoration. Ninety restorations were placed on Class I or Class II cavities. For the restoration protocol, a simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied over wet (WD) or dry dentin (DD) and later restored with a bulk-fill composite (Filtek Bulk Fill) under rubber dam isolation. Each restoration was evaluated using the World Dental Federation (FDI) criteria after 6, 12, and 36 months of clinical service, regarding the following principal restoration characteristics: postoperative sensitivity, marginal discoloration, marginal adaptation, fracture of material and retention, and recurrence of caries. Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used for statistical analysis. RESULTS: After 36 months of clinical evaluation, no significant difference between groups was observed in each FDI criterion (p > 0.05). Twenty restorations (WD=10, DD=10) showed minor marginal staining, and twenty-two restorations (WD=11, DD=11) presented small marginal adaptation defects (p > 0.05). Four restorations were lost (WD = 2, DD = 2) and the fracture rates (95% confidence interval) were 94.9% for each one, without significant difference between wet and dry dentin (p > 0.05). SIGNIFICANCE: The degree of dentin moisture does not seem to affect the clinical performance of a simplified etch-and-rinse adhesive in posterior restorations when the adhesive is applied vigorously over the dentine surface.


Asunto(s)
Caries Dental , Cementos Dentales , Humanos , Recubrimientos Dentinarios/química , Cementos de Resina , Restauración Dental Permanente/métodos , Resinas Compuestas/química , Caries Dental/terapia , Dentina , Adaptación Marginal Dental
3.
Materials (Basel) ; 15(17)2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-36079385

RESUMEN

This in vitro study aimed to evaluate the effect of different bonding strategies on the micro-shear bond strength (µSBS) of luting agents to CAD−CAM composites. Surface scanning electron microscopy (SEM) and spectroscopy by energy-dispersive X-ray spectroscopy (EDS) were performed to analyze the surfaces of the composite before and after bonding treatment. Three CAD−CAM composites were evaluated: Lava Ultimate restorative (LU), Brava Blocks (BR), and Vita Enamic (VE). The LU and BR surfaces were sandblasted using aluminum oxide, while the VE surfaces were etched using a 5% hydrofluoric acid gel according to the manufacturers' recommendations. All surfaces were subjected to the following bonding strategies (n = 15): adhesive with silane and MDP (ScotchBond Universal, 3M Oral Care, St Paul, MI, USA); adhesive with MDP (Ambar Universal, FGM, Joinville, Brazil); adhesive without silane or MDP (Prime&Bond Elect, Dentsply Sirona, Charlotte, NC, USA), pure silane without MDP (Angelus, Londrina, Brazil), and pure silane with MDP (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstei). Afterwards, tygons were filled with RelyX Ultimate (3M Oral Care), AllCem (FGM), or Enforce (Dentsply Sirona), which were light-cured and subjected to the µSBS test. Data were analyzed using two-way ANOVA and Bonferroni's post hoc test (α = 0.05). Additional blocks (n = 15) were subjected to scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) before and after the surface treatment. The µSBS values on VE surfaces were higher than those observed on LU and BR surfaces (p < 0.001). Silane without MDP (Allcem) promoted the highest µSBS values, while silane with MDP (RelyX Ultimate) provided the highest values among all bonding strategies (p < 0.001). Enforce promoted no significant difference in µSBS values. SEM and EDS analyses detected noticeable changes to the surface morphology and composition after the surface treatment. The effectiveness of the bonding strategy may vary according not only to the CAD−CAM composite but also to resin cement/bonding agent/silane used.

4.
BMC Health Serv Res ; 22(1): 393, 2022 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-35337336

RESUMEN

BACKGROUND: The COVID-19 pandemic has significantly influenced the routine of healthcare workers. This study investigated the impact of the pandemic on dental practice and dentists' feelings in Latin America. METHODS: A survey was conducted with dentists from 11 Spanish-speaking Latin American countries in September-December 2020. Professionals were invited by email and via an open campaign promoted on social media. The questions investigated dental care routines, practice changes, and feelings about the pandemic. Descriptive statistics were used to identify frequencies and distributions of variables. Proportions were compared using chi-square tests. RESULTS: A total of 2127 responses were collected from a sample with diverse demographic, sex, work, and education characteristics. The impact of COVID-19 was considered high/very high by 60% of respondents. The volume of patients assisted weekly was lower compared with the pre-pandemic period (mean reduction = 14 ± 15 patients). A high rate of fear to contracting the COVID-19 at work was observed (85%); 4.9% of participants had a positive COVID-19 test. The main professional challenges faced by respondents were reduction in the number of patients or financial gain (35%), fear of contracting COVID-19 (34%), and burden with or difficulty in purchasing new personal protective equipment (22%). The fear to contracting COVID-19 was influenced by the number of weekly appointments. A positive test by the dentists was associated with their reports of having assisted COVID-19 patients. The most cited feelings about the pandemic were uncertainty, fear, worry, anxiety, and stress. Negative feelings were more prevalent for professionals who did not receive training for COVID-19 preventive measures and those reporting higher levels of fear to contract the disease. CONCLUSION: This multi-country survey indicated a high impact of the pandemic on dental care routines in Latin America. A massive prevalence of bad feelings was associated with the pandemic.


Asunto(s)
COVID-19 , COVID-19/epidemiología , Odontólogos , Emociones , Humanos , América Latina/epidemiología , Pandemias , Encuestas y Cuestionarios
5.
Clin Oral Investig ; 26(6): 4391-4405, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35149904

RESUMEN

OBJECTIVES: This study aimed at evaluating the microtensile bond strength (µTBS) and the resin-dentine ultramorphology (24 h and 10 months ageing) of contemporary universal adhesives applied in self-etch (SE) or etch-and-rinse (ER) mode. MATERIALS AND METHODS: Sixty-four sound human molars were collected and randomly allocated in 4 main experimental groups (n = 16) according to the adhesive system employed and subsequently divided into two subgroups depending on their application mode SE or ER (n = 8): ZipBond X (ZBX-SE; ZBX-ER), Prime and Bond Active (PBA-SE; PBA-ER), Clearfil Universal Bond Quick (CBQ-SE; CBQ-ER) or Scotchbond Universal (SCH-SE; SCH-ER). The specimens were cut into sticks with a cross-sectional area of approximately 0.9 mm2 and subjected to µTBS testing at 24 h or after 10 months of ageing in artificial saliva (AS). Five representative fractured specimens from each group were analysed using field-emission scanning electron microscopy (FE-SEM). Resin-dentine slabs (Ø 0.9mm2) from each experimental group were immersed in Rhodamine B and subsequently analysed using confocal microscopy analysis (CLSM). The µTBS results were analysed using a two-way ANOVA and Newman-Keuls multiple-comparison test (α = 0.05). RESULTS: ZBX, PBA and SCH exhibited greater µTBS values than CQB at 24 h in both SE and ER modes (p < 0.05). CQB showed a significant decrease in µTBS values after ageing both when used in SE and ER mode (p < 0.05). ZBX-ER exhibited no significant differences in the µTBS test after ageing (p > 0.05), while a significant drop in µTBS was seen in SCH-ER and APB-ER after 10-month ageing (p < 0.05). Clear signs of degradation were evident in the resin-dentine interface created with CQB regardless of the application mode or the ageing time. In APB-ER and SCH-ER groups, such signs of degradation were evident after ageing in AS. ZBX showed slight dye infiltration both when used in ER and SE mode. CONCLUSIONS: The long-term bonding performance of modern universal adhesives is usually influenced by the adhesive strategy employed; self-etching application should be prioritised during dentine bonding. Moreover, the use of shortened bonding protocols may compromise the quality of the resin-dentine interface and the bonding performance of most modern universal adhesives. CLINICAL RELEVANCE: The use of etch-and-rinse bonding procedures, as well as "shortened" application protocols should be eluded when using modern universal adhesives in dentine. However, new generation universal adhesives based on innovative chemical formulations may probably allow clinicians to achieve long-term bonding performance with such simplified system also when employed in ER mode.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Grabado Ácido Dental/métodos , Adhesivos/análisis , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/química , Dentina/química , Recubrimientos Dentinarios/química , Humanos , Ensayo de Materiales , Metacrilatos/química , Cementos de Resina/química , Propiedades de Superficie , Resistencia a la Tracción
6.
J Esthet Restor Dent ; 34(6): 951-958, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-34617663

RESUMEN

OBJECTIVE: The aims of this study were to evaluate whether the use of a dentifrice containing 5% potassium nitrate (KNO3 ) prior to and during in-office dental bleaching reduces bleaching-induced tooth sensitivity and affects bleaching efficiency. MATERIALS AND METHODS: Thirty-eight individuals were randomly distributed into two groups (n = 19). The experimental group performed toothbrushing using a dentifrice containing 5% KNO3 , one week before treatment and before the first and second bleaching sessions. In the control group, a placebo dentifrice without KNO3 was applied as described for the first group. Tooth sensitivity was recorded on visual analog scales (VAS) and numeric rating scales (NRS) immediately and up to 48 h after bleaching sessions. Color change at different time intervals, was evaluated with shade guide units (∆SGU) and a digital spectrophotometer (∆E CIELab 1976 and CIEDE2000) at baseline and 7, 15, and 30 days post-bleaching. Mann-Whitney test and t-test were used to evaluate TS intensity for NRS and VAS scales, respectively, and T-test was used for color difference evaluation. RESULTS: No significant difference in tooth sensitivity's absolute risk and intensity were observed between tested groups in any evaluated treatment time for NRS (p = 0.91) or VAS scales (p = 0.48). T-test showed no significant difference in both ∆E and ∆SGU tooth color among the experimental and control groups during the different evaluation times (p = 0.27). CONCLUSION: The use of a dentifrice containing 5% KNO3 does not prevent post-operatory tooth sensitivity but allows the same whitening efficiency as a regular dentifrice. CLINICAL SIGNIFICANCE: The use of a dentifrice-containing KNO3 did not prevent bleaching-induced tooth sensitivity when high-concentrated hydrogen peroxide was used for in-office bleaching.


Asunto(s)
Dentífricos , Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Dentífricos/uso terapéutico , Sensibilidad de la Dentina/tratamiento farmacológico , Sensibilidad de la Dentina/prevención & control , Humanos , Peróxido de Hidrógeno/efectos adversos , Nitratos , Compuestos de Potasio/uso terapéutico , Blanqueamiento de Dientes/efectos adversos , Blanqueadores Dentales/efectos adversos , Resultado del Tratamiento
7.
Polymers (Basel) ; 13(7)2021 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-33918441

RESUMEN

The aim of the present study was to evaluate the influence of several experimental pretreatment crosslinker solutions on the resin polymer-dentine interface created using a representative universal adhesive system, by means of microtensile bond strength testing (µTBS), nanomechanical properties and ultramorphology confocal laser scanning microscopy (CLSM). Five experimental solutions containing different flavonoids were applied as dentine pretreatment after acid etching. A control pretreatment group containing no flavonoid was also employed. A representative modern universal adhesive was then applied, followed by a 3 mm thick composite built up. Specimens were sectioned into sticks and submitted to a µTBS test or nanoindentation analysis along the interface (24 h or 25,000 thermocycles). The ultramorphology of the polymer-resin interface was also evaluated using CLSM. The results were analyzed using two-way ANOVA and Bonferroni's post hoc test (α = 0.05). All flavonoids improved short- and long-term µTBS values (p < 0.01), while only some specific such solutions improved the nanomechanical properties (p < 0.05) and preserved the structural morphology of the interface after aging. Pretreatment of acid-etched dentine using specific flavonoid-containing solutions may be a promising approach to improve both the nanomechanical properties and the durability of modern universal adhesive systems.

8.
Dental Press J Orthod ; 26(1): e2119150, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33729290

RESUMEN

INTRODUCTION: Third generation of LED light curing units might be used in short exposure periods for orthodontic brackets bonding. OBJECTIVE: This study evaluated the effect of the different radiant exposure (RE) values: Manufacturers' instructions (MI), ½ MI, 1/4 MI and Turbo mode. Two third-generation LED curing units were used: VALO® and Bluephase 20i® . The degree of conversion (DC) and Vickers hardness (VHN) of an orthodontic composite (OC) (Transbond XT) under metallic (MB) or ceramic brackets (CB) were measured. METHODS: OC was applied to the bracket base, which was then placed over an attenuated total reflectance (ATR) table coupled to an infrared light spectroscope, or to a glass surface for the VHN analysis. The specimens were light-cured and DC values were calculated. The VHN was obtained in a microhardness tester. The data were analyzed with 2-way ANOVA followed by Tukey's post-hoc test (pre-set α=0.05). Linear regression analysis evaluated the relationship between RE values and dependent variables. RESULTS: CB allowed higher DC and VHN values than MB (p< 0.001). No significant difference was noted among groups when CB were used. For MB, MI groups showed the highest DC and VHN values. A significant, but weak relationship was found between delivered RE values and dependent variables. CONCLUSIONS: The decrease in RE values from third generation LED CU did not jeopardize the DC values when CB were used, but can compromise DC and VHN values when MB are used.


Asunto(s)
Luces de Curación Dental , Soportes Ortodóncicos , Cerámica , Resinas Compuestas , Dureza , Ensayo de Materiales , Polimerizacion , Cementos de Resina , Propiedades de Superficie
9.
J Prosthet Dent ; 125(3): 535-542, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32204928

RESUMEN

STATEMENT OF PROBLEM: Information regarding the shrinkage kinetics and monomer conversion of dual-polymerized conventional and self-adhesive resin luting agents (RLA) in situ is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the shrinkage strain and ratio of 1 conventional and 1 self-adhesive RLA by using fiber optic sensors based on Bragg gratings and Vickers hardness in the root canal. MATERIAL AND METHODS: The root canals of 34 single-rooted premolars were endodontically treated and assigned to 2 groups according to the RLA: RelyX ARC (ARC) and RelyX U200 (U200). Two Bragg grating sensors were attached to fiber posts (n=10), and both post and RLA were placed inside the root canal so that shrinkage strain and ratio values could be measured at the cervical and apical root thirds. For hardness analysis (n=7), two 1-mm-thick slices of each root-third (cervical and apical) were obtained, and 4 indentations were made on the RLA layer. The shrinkage strain and rate, as well as hardness data, were evaluated by using 2-way repeated-measures ANOVA followed by the Bonferroni post hoc test when a significant interaction between factors was detected (α=.05). RESULTS: The shrinkage strain and rate values of both RLAs were higher at the cervical third than those at the apical third. ARC showed higher shrinkage strain than U200 at the cervical third. The highest hardness values were observed at the cervical third, while ARC showed the lowest hardness values at the apical third. CONCLUSIONS: The shrinkage kinetics profile and hardness of self-adhesive RLA may differ from those of conventional RLA depending on the root third.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Cementos Dentales , Cavidad Pulpar , Dentina , Cinética , Ensayo de Materiales , Polimerizacion , Cementos de Resina
10.
Dent Mater ; 36(9): 1151-1160, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32620332

RESUMEN

OBJECTIVES: To evaluate the effect of experimental dentin pre-treatment solutions formulated with different flavonoids on microtensile bond strength (µTBS), nanohardness (NH) and ultra-morphological characteristics of artificial caries-affected dentin (CAD) bonded using a universal bonding system. METHODS: A microbiological method was used to create an artificial CAD in 91 human molars. Five experimental pre-treatment solutions were created using the following flavonoids: quercetin (QUE); hesperidin (HES); rutin (RUT); naringin (NAR), or proanthocyanidin (PRO). A placebo solution (PLA) with no flavonoids added was also evaluated. The flavonoids or placebo solutions were applied to the CAD prior to the application and photoactivation of a universal adhesive (Scotchbond Universal, 3M Oral Care). A control group (CON), in which only the bonding agent was applied without any flavonoid solution, was also evaluated. A 3-mm-thick block of resin composite (Opallis, FGM) was built up on the flat bonded CAD surfaces and was light-cured following the manufacturer's instructions. Specimens were sectioned to obtain resin-dentin slices and sticks (cross-sectional area of 0.8 mm2). The µTBS, NH, and confocal ultramorphology analysis of resin-dentin interface was evaluated at 24 h and after thermo-cycling aging (25,000 cycles). The results were analyzed using 2-way ANOVA followed by Bonferroni's post hoc test (pre-set α = 0.05). RESULTS: The specimens from groups QUE, NAR, and RUT presented greater µTBS values than those from CON group (p<0.05). Specimens from some of these experimental groups presented greater nanomechanical properties (p<0.05), and no morphological degradation at the resin-dentin interface after aging. SIGNIFICANCE: The use of exogenous cross-linkers as dentin pre-treatment before bonding procedures may represent a suitable strategy to improve the longevity of universal adhesive systems applied to caries-affected dentin.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Resinas Compuestas , Cementos Dentales , Dentina , Flavonoides , Humanos , Ensayo de Materiales , Cementos de Resina , Resistencia a la Tracción
11.
Dent Mater ; 36(9): 1201-1213, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32576408

RESUMEN

OBJECTIVE: To evaluate the influence of light emitted from two Polywave®, LED light-curing units (LCU) on in vivo pulp temperature (PT) rise and signs of acute inflammatory response in pulps of human premolar having deep Class V preparations. METHODS: Sixty intact, first premolars from 15 volunteers requiring extraction received infiltrative anesthesia. A sterile thermocouple probe was inserted within the pulp tissue through a minute occlusal pulp exposure in only 45 teeth (n = 9) to continuously monitor PT (°C). A deep buccal Class V preparation was created, and the surface was exposed to light from a commercial Polywave LCU (Bluephase 20i (20i), Ivoclar Vivadent) or from an experimental LCU (Exp) using the exposure modes (EM): 1s/Exp and 2s/Exp, 10s/20i, 20s/20i, and 60s/20i. Peak PT and PT rise values above baseline (ΔT) data were evaluated using a one-way ANOVA followed by Tukey's post-hoc test (α = 5%). Teeth used for histological and immunohistochemical analyses (n = 3) were extracted approximately 2 h after exposure to the LCU. RESULTS: No significant difference in peak PT and ΔT values was noted between 2s/Exp and 20s/20i groups, which both exhibited higher values than 1s/Exp and 10s/20i groups (p < 0.001). Dilated and congested blood vessels were seen after exposure to 1s/Exp, 2s/Exp, or 60s/20i EMs. The expression of IL-1ß and TNF-α tended to be more intense when higher irradiance was delivered. SIGNIFICANCE: Although higher irradiance delivered over a short exposure caused lower PT rise than 5.5 °C, such EMs should be used with caution, as they have more potential to harm the pulp tissue.


Asunto(s)
Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Diente Premolar , Resinas Compuestas , Pulpa Dental , Humanos , Temperatura
12.
J Mech Behav Biomed Mater ; 100: 103366, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31422314

RESUMEN

This study evaluated the MMP inhibition of the zinc oxide and copper nanoparticles (ZnO/CuNp), and the effects of their addition into adhesives on antimicrobial activity (AMA), ultimate tensile strength (UTS), in vitro degree of conversion (in vitro-DC), as well as, resin-dentin bond strength (µTBS), nanoleakage (NL) and in situ-DC on caries-affected dentin. Anti-MMP activity was evaluated for several MMPs. ZnO/CuNp (0% [control]; 5/0.1 and 5/0.2 wt%) were added into Prime&Bond Active (PBA) and Ambar Universal (AMB). The AMA was evaluated against Streptococcus mutans. UTS were tested after 24 h and 28d. After induced caries, adhesives and composite were applied to flat dentin surfaces, and specimens were sectioned to obtain resin-dentin sticks. µTBS, NL, in vitro-DC and in situ-DC were evaluated after 24 h. ANOVA and Tukey's test were applied (α = 0.05). ZnO/CuNp demonstrated anti-MMP activity (p < 0.05). The addition of ZnO/CuNp increased AMA and UTS (AMB; p < 0.05). UTS for PBA, in vitro-DC, in situ-DC and µTBS for both adhesives were maintained with ZnO/CuNp (p > 0.05). However, lower NL was observed for ZnO/CuNp groups (p < 0.05). The addition of ZnO/CuNp in adhesives may be an alternative to provide antimicrobial, anti-MMP activities and improves the integrity of the hybrid layer on caries-affected dentin.


Asunto(s)
Cobre/química , Recubrimiento Dental Adhesivo/instrumentación , Caries Dental , Dentina/química , Nanopartículas del Metal/química , Óxido de Zinc/química , Grabado Ácido Dental , Adhesivos , Adolescente , Adulto , Antiinfecciosos/farmacología , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Humanos , Ensayo de Materiales , Metaloproteinasas de la Matriz/metabolismo , Nanopartículas , Cementos de Resina/química , Streptococcus mutans/efectos de los fármacos , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA