1.
Catheter Cardiovasc Interv ; 85(1): E1-9, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24905554

RESUMEN

AIM: The MGuard Stent (MGS) was designed to prevent distal embolization of thrombus and has been shown to improve microcirculation in ST-elevation myocardial infarction (STEMI). However, there are no real world data comparing it with the bare metal stent (BMS). The aim of this study is to determine the efficacy and safety of the MGS in STEMI in the real world compared to the BMS. METHODS AND RESULTS: In total, 262 patients were included from a single centre, of which 35.9% had an MGS implanted. Two groups of 79 patients were established after propensity score matching, and they were similar in terms of baseline and periprocedural variables. The mean follow-up was 321 ± 12.94 days. There was no difference in mortality (7.6% in both groups), major adverse cardiac events (20.3% vs. 12.7%, P = 0.198), non-cardiac mortality, or non-fatal myocardial infarction (6.3% in both groups). Target lesion revascularization (TLR) was significantly higher in the MGS group (11.4% (9) vs. 1.3% (1) P < 0.01; RR 10.02 [1.23-81.16]). CONCLUSION: Our study is the first to compare the MGS with the BMS in STEMI in the real world, and it also appears to confirm that although the MGS is a safe device in STEMI that is not associated with increased mortality, it is associated with a higher long-term TLR rate. © 2014 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Metales , Infarto del Miocardio/terapia , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Reestenosis Coronaria/etiología , Trombosis Coronaria , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Oportunidad Relativa , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
2.
Rev Esp Cardiol ; 54(12): 1406-10, 2001 Dec.
Artículo en Español | MEDLINE | ID: mdl-11754786

RESUMEN

INTRODUCTION AND OBJECTIVES: Efficacy of the hemostatic puncture closure 8 Fr Angio-Seal device for percutaneous puncture closure after a catheterism has been previously demonstrated, but the experience provided has been obtained with 8 Fr devices. At present the device has been modified and its size reduced to 6 Fr. In this pilot study we evaluate the efficacy of the new hemostatic 6 Fr Angio-Seal device and its safety when early deambulation post-diagnostic and/or therapeutic catheterization is established. PATIENTS AND METHODS: Prospective study of 150 consecutive patients randomized either for application of the 6 Fr Angio-Seal device (group A; n = 75), in which early ambulation was indicated, or manual compression (group B; n = 75), with ambulation 12 h after cardiac catheterization. Basal data, including clinical and angiographic characteristics and previous treatment with heparin and platelet aggregation inhibitors were similar in both groups. RESULTS: The time of hemostasia was significantly shorter in group A than in group B (118 +/- 210 s in A vs 1320 +/- 370 s in B; p (3/4) 0,001), and with early ambulation (3,1 +/- 0,4 h in A vs 12,3 +/- 3,1 h in B; p (3/4) 0,001) no local complications were observed. CONCLUSIONS: The 6 Fr Angio-Seal hemostatic device diminished the hemostasia time and early ambulation could be achieved. In this pilot study no complications due to early movilization were observed, but the safety of the new hemostatic device after diagnostic or therapeutic catheterizations needs to be evaluated in greater series.


Asunto(s)
Cateterismo Cardíaco , Hemostasis Quirúrgica/instrumentación , Implantes Absorbibles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Punciones , Técnicas de Sutura , Factores de Tiempo , Caminata
3.
Rev Esp Cardiol ; 44(1): 62-5, 1991 Jan.
Artículo en Español | MEDLINE | ID: mdl-1871412

RESUMEN

A nineteen-year-old male was diagnosed as having a foreign body in his cardiac muscle after a mild open thoracic injury. Diagnosis and follow-up was performed by two-dimensional echocardiography. He did not show any complications after a 6 month follow-up. We emphasize the rare presentation of this entity and the usefulness of echocardiography to attain the foreign body's size and place. Also, echocardiography helps therapeutic management and diagnosis of complications.


Asunto(s)
Ecocardiografía , Cuerpos Extraños/diagnóstico por imagen , Miocardio , Adulto , Diagnóstico Diferencial , Urgencias Médicas , Cuerpos Extraños/etiología , Lesiones Cardíacas/complicaciones , Lesiones Cardíacas/diagnóstico por imagen , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA