Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Bioeng Biotechnol ; 10: 910798, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36003533

RESUMEN

Technical evaluation of swimming performance is an essential factor in preparing elite swimmers for their competitions. Inertial measurement units (IMUs) have attracted much attention recently because they can provide coaches with a detailed analysis of swimmers' performance during training. A coach can obtain a quantitative and objective evaluation from IMU. The purpose of this study was to validate the use of a new phase-based performance assessment with a single IMU worn on the sacrum during training sessions. Sixteen competitive swimmers performed five one-way front crawl trials at their maximum speed wearing an IMU on the sacrum. The coach recorded the lap time for each trial, as it remains the gold standard for swimmer's performance in competition. The measurement was carried out once a week for 10 consecutive weeks to monitor the improvement in the swimmers' performance. Meaningful progress was defined as a time decrease of at least 0.5 s over a 25 m lap. Using validated algorithms, we estimated five goal metrics from the IMU signals representing the swimmer's performance in the swimming phases (wall push-off, glide, stroke preparation, free-swimming) and in the entire lap. The results showed that the goal metrics for free-swimming phase and the entire lap predicted the swimmer's progress well (e.g., accuracy, precision, sensitivity, and specificity of 0.91, 0.89, 0.94, and 0.95 for the lap goal metric, respectively). As the goal metrics for initial phases (wall push-off, glide, stroke preparation) achieved high precision and specificity (≥0.79) in progress detection, the coach can use them for swimmers with satisfactory free-swimming phase performance and make further improvements in initial phases. Changes in the values of the goal metrics have been shown to be correlated with changes in lap time when there is meaningful progress. The results of this study show that goal metrics provided by the phase-based performance evaluation with a single IMU can help monitoring swimming progress. Average velocity of the lap can replace traditional lap time measurement, while phase-based goal metrics provide more information about the swimmer's performance in each phase. This evaluation can help the coach quantitatively monitor the swimmer's performance and train them more efficiently.

2.
Sensors (Basel) ; 22(9)2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35591046

RESUMEN

Swimming coaches provide regular timed and technical feedback to swimmers and guide them efficiently in training sessions. Due to the complexity of swimmers' performance, which is not visible in qualitative observation, quantitative and objective performance evaluation can better assist the coach in this regard. Inertial measurement units (IMUs) are used in swimming for objective performance evaluation. In this study, we propose a new performance evaluation feedback (SmartSwim) using IMU and investigate its effects on the swimmer's weekly progress. Measurements were conducted each week with 15 competitive swimmers for 10 weeks using a Sacrum IMU. The SmartSwim report included a comprehensive representation of performance based on goal metrics of each phase extracted from the IMU signals. The swimmers were divided into two groups: the experimental and control groups. The SmartSwim report for each swimmer in the experimental group was given to the coach, who used it to adjust the training accordingly. The results showed that the experimental group outperformed the control group when comparing each swimmer, each session and the whole sessions. At the level of each individual, more members of the experimental group showed significant downward trend of average lap time (Mann-Kendall trend test, 95% confidence level). While comparing the sessions, the experimental group showed significantly lower lap time than the control group from the sixth session onwards (p-value < 0.05 from t-test). Considering all sessions, the experimental group showed significantly higher progress, lower average lap time, and more consistent records (Mann-Whitney U test at 95% confidence level) than the control group. This study demonstrated that SmartSwim can assist coaching by quantitatively assessing swimmers' performance, leading to more efficient training.


Asunto(s)
Tutoría , Motivación , Vehículos a Motor , Estadísticas no Paramétricas , Natación
3.
Front Bioeng Biotechnol ; 9: 793302, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34950648

RESUMEN

Comprehensive monitoring of performance is essential for swimmers and swimming coaches to optimize the training. Regardless of the swimming technique, the swimmer passes various swimming phases from wall to wall, including a dive into the water or wall push-off, then glide and strokes preparation and finally, swimming up to the turn. The coach focuses on improving the performance of the swimmer in each of these phases. The purpose of this study was to assess the potential of using a sacrum-worn inertial measurement unit (IMU) for performance evaluation in each swimming phase (wall push-off, glide, stroke preparation and swimming) of elite swimmers in four main swimming techniques (i.e. front crawl, breaststroke, butterfly and backstroke). Nineteen swimmers were asked to wear a sacrum IMU and swim four one-way 25 m trials in each technique, attached to a tethered speedometer and filmed by cameras in the whole lap as reference systems. Based on the literature, several goal metrics were extracted from the instantaneous velocity (e.g. average velocity per stroke cycle) and displacement (e.g. time to reach 15 m from the wall) data from a tethered speedometer for the swimming phases, each one representing the goodness of swimmer's performance. Following a novel approach, that starts from swimming bout detection and continues until detecting the swimming phases, the IMU kinematic variables in each swimming phase were extracted. The highly associated variables with the corresponding goal metrics were detected by LASSO (least absolute shrinkage and selection operator) variable selection and used for estimating the goal metrics with a linear regression model. The selected kinematic variables were relevant to the motion characteristics of each phase (e.g. selection of propulsion-related variables in wall push-off phase), providing more interpretability to the model. The estimation reached a determination coefficient (R2) value more than 0.75 and a relative RMSE less than 10% for most goal metrics in all swimming techniques. The results show that a single sacrum IMU can provide a wide range of performance-related swimming kinematic variables, useful for performance evaluation in four main swimming techniques.

4.
IEEE J Biomed Health Inform ; 25(11): 4217-4228, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33914688

RESUMEN

Gait speed as a powerful biomarker of mobility is mostly assessed in controlled environments, e.g. in the clinic. With wearable inertial sensors, gait speed can be estimated in an objective manner. However, most of the previous works have validated the gait speed estimation algorithms in clinical settings which can be different than the home assessments in which the patients demonstrate their actual performance. Moreover, to provide comfort for the users, devising an algorithm based on a single sensor setup is essential. To this end, the goal of this study was to develop and validate a new gait speed estimation method based on a machine learning approach to predict gait speed in both clinical and home assessments by a sensor on the lower back. Moreover, two methods were introduced to detect walking bouts during daily activities at home. We have validated the algorithms in 35 patients with multiple sclerosis as it often presents with mobility difficulties. Therefore, the robustness of the algorithm can be shown in an impaired or slow gait. Against silver standard multi-sensor references, we achieved a bias close to zero and a precision of 0.15 m/s for gait speed estimation. Furthermore, the proposed machine learning-based locomotion detection method had a median of 96.8% specificity, 93.0% sensitivity, 96.4% accuracy, and 78.6% F1-score in detecting walking bouts at home. The high performance of the proposed algorithm showed the feasibility of the unsupervised mobility assessment introduced in this study.


Asunto(s)
Esclerosis Múltiple , Algoritmos , Marcha , Humanos , Aprendizaje Automático , Esclerosis Múltiple/diagnóstico , Caminata , Velocidad al Caminar
5.
NPJ Parkinsons Dis ; 7(1): 24, 2021 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-33674597

RESUMEN

Gait speed often referred as the sixth vital sign is the most powerful biomarker of mobility. While a clinical setting allows the estimation of gait speed under controlled conditions that present functional capacity, gait speed in real-life conditions provides the actual performance of the patient. The goal of this study was to investigate objectively under what conditions during daily activities, patients perform as well as or better than in the clinic. To this end, we recruited 27 Parkinson's disease (PD) patients and measured their gait speed by inertial measurement units through several walking tests in the clinic as well as their daily activities at home. By fitting a bimodal Gaussian model to their gait speed distribution, we found that on average, patients had similar modes in the clinic and during daily activities. Furthermore, we observed that the number of medication doses taken throughout the day had a moderate correlation with the difference between clinic and home. Performing a cycle-by-cycle analysis on gait speed during the home assessment, overall only about 3% of the strides had equal or greater gait speeds than the patients' capacity in the clinic. These strides were during long walking bouts (>1 min) and happened before noon, around 26 min after medication intake, reaching their maximum occurrence probability 3 h after Levodopa intake. These results open the possibility of better control of medication intake in PD by considering both functional capacity and continuous monitoring of gait speed during real-life conditions.

6.
Artículo en Inglés | MEDLINE | ID: mdl-33014992

RESUMEN

Power-Force-Velocity profile obtained during a sprint test is crucial for designing personalized training and evaluating injury risks. Estimation of instantaneous velocity is requisite for developing these profiles and the predominant method for this estimation assumes it to have a first order exponential behavior. While this method remains appropriate for maximal sprints, the sprint velocity profile may not always show a first-order exponential behavior. Alternately, velocity profile has been estimated using inertial sensors, with a speed radar, or a smartphone application. Existing methods either relied on the exponential behavior or timing gates for drift removal, or estimated only the mean velocity. Thus, there is a need for a more flexible and appropriate approach, allowing for instantaneous velocity estimation during sprint tests. The proposed method aims to solve this problem using a sensor fusion approach, by combining the signals from wearable Global Navigation Satellite System (GNSS) and inertial measurement unit (IMU) sensors. We collected data from nine elite sprinters, equipped with a wearable GNSS-IMU sensor, who ran two trials each of 60 and 30/40 m sprints. We developed an algorithm using a gradient descent-based orientation filter, which simplified our model to a linear one-dimensional model, thus allowing us to use a simple Kalman filter (KF) for velocity estimation. We used two cascaded KFs, to segment the sprint data precisely, and to estimate the velocity and the sprint duration, respectively. We validated the estimated velocity and duration with speed radar and photocell data as reference. The median RMS error for the estimated velocity ranged from 6 to 8%, while that for the estimated sprint duration lied between 0.1 and -6.0%. The Bland-Altman plot showed close agreement between the estimated and the reference values of maximum velocity. Examination of fitting errors indicated a second order exponential behavior for the sprint velocity profile, unlike the first order behavior previously suggested in literature. The proposed sensor-fusion algorithm is valid to compute an accurate velocity profile with respect to the radar; it can compensate for and improve upon the accuracy of the individual IMU and GNSS velocities. This method thus enables the use of wearable sensors in the analysis of sprint test.

7.
J Neuroeng Rehabil ; 17(1): 70, 2020 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-32493496

RESUMEN

BACKGROUND: Sit-to-stand and stand-to-sit transitions are frequent daily functional tasks indicative of muscle power and balance performance. Monitoring these postural transitions with inertial sensors provides an objective tool to assess mobility in both the laboratory and home environment. While the measurement depends on the sensor location, the clinical and everyday use requires high compliance and subject adherence. The objective of this study was to propose a sit-to-stand and stand-to-sit transition detection algorithm that works independently of the sensor location. METHODS: For a location-independent algorithm, the vertical acceleration of the lower back in the global frame was used to detect the postural transitions in daily activities. The detection performance of the algorithm was validated against video observations. To investigate the effect of the location on the kinematic parameters, these parameters were extracted during a five-time sit-to-stand test and were compared for different locations of the sensor on the trunk and lower back. RESULTS: The proposed detection method demonstrates high accuracy in different populations with a mean positive predictive value (and mean sensitivity) of 98% (95%) for healthy individuals and 89% (89%) for participants with diseases. CONCLUSIONS: The sensor location around the waist did not affect the performance of the algorithm in detecting the sit-to-stand and stand-to-sit transitions. However, regarding the accuracy of the kinematic parameters, the sensors located on the sternum and L5 vertebrae demonstrated the highest reliability.


Asunto(s)
Acelerometría/instrumentación , Algoritmos , Movimiento , Equilibrio Postural/fisiología , Dispositivos Electrónicos Vestibles , Adulto , Anciano , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento/fisiología , Reproducibilidad de los Resultados , Torso
8.
Front Bioeng Biotechnol ; 8: 597738, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33520955

RESUMEN

Inertial measurement units (IMU) are proven as efficient tools for swimming analysis by overcoming the limits of video-based systems application in aquatic environments. However, coaches still believe in the lack of a reliable and easy-to-use analysis system for swimming. To provide a broad view of swimmers' performance, this paper describes a new macro-micro analysis approach, comprehensive enough to cover a full training session, regardless of the swimming technique. Seventeen national level swimmers (5 females, 12 males, 19.6 ± 2.1 yrs) were equipped with six IMUs and asked to swim 4 × 50 m trials in each swimming technique (i.e., frontcrawl, breaststroke, butterfly, and backstroke) in a 25 m pool, in front of five 2-D cameras (four under water and one over water) for validation. The proposed approach detects swimming bouts, laps, and swimming technique in macro level and swimming phases in micro level on all sensor locations for comparison. Swimming phases are the phases swimmers pass from wall to wall (wall push-off, glide, strokes preparation, swimming, and turn) and micro analysis detects the beginning of each phase. For macro analysis, an overall accuracy range of 0.83-0.98, 0.80-1.00, and 0.83-0.99 were achieved, respectively, for swimming bouts detection, laps detection and swimming technique identification on selected sensor locations, the highest being achieved with sacrum. For micro analysis, we obtained the lowest error mean and standard deviation on sacrum for the beginning of wall-push off, glide and turn (-20 ± 89 ms, 4 ± 100 ms, 23 ± 97 ms, respectively), on shank for the beginning of strokes preparation (0 ± 88 ms) and on wrist for the beginning of swimming (-42 ± 72 ms). Comparing the swimming techniques, sacrum sensor achieves the smallest range of error mean and standard deviation during micro analysis. By using the same macro-micro approach across different swimming techniques, this study shows its efficiency to detect the main events and phases of a training session. Moreover, comparing the results of both macro and micro analyses, sacrum has achieved relatively higher amounts of accuracy and lower mean and standard deviation of error in all swimming techniques.

9.
Sensors (Basel) ; 18(3)2018 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-29547554

RESUMEN

Ski Mountaineering (SkiMo) is a fast growing sport requiring both endurance and technical skills. It involves different types of locomotion with and without the skis. The aim of this study is to develop and validate in the snowfield a novel inertial-based system for analysing cycle parameters and classifying movement in SkiMo in real-time. The study was divided into two parts, one focused on real-time parameters estimation (cadence, distance from strides, stride duration, stride length, number of strides, slope gradient, and power) and, second, on transition detection (kickturns, skin on, skin off, ski on and off backpack) in order to classify between the different types of locomotion. Experimental protocol involved 16 experienced subjects who performed different SkiMo trials with their own equipment instrumented with a ski-mounted inertial sensor. The results obtained by the algorithm showed precise results with a relative error near 5% on all parameters. The developed system can, therefore, be used by skiers to obtain quantitative training data analysis and real-time feedback in the field. Nevertheless, a deeper validation of this algorithm might be necessary in order to confirm the accuracy on a wider population of subjects with various skill levels.


Asunto(s)
Movimiento , Algoritmos , Fenómenos Biomecánicos , Humanos , Montañismo , Esquí
10.
Childs Nerv Syst ; 33(12): 2159-2168, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28842792

RESUMEN

PURPOSE: Upper limb assessments in children with hemiparesis rely on clinical measurements, which despite standardization are prone to error. Recently, 3D movement analysis using optoelectronic setups has been used to measure upper limb movement, but generalization is hindered by time and cost. Body worn inertial sensors may provide a simple, cost-effective alternative. METHODS: We instrumented a subset of 30 participants in a mirror therapy clinical trial at baseline, post-treatment, and follow-up clinical assessments, with wireless inertial sensors positioned on the arms and trunk to monitor motion during reaching tasks. RESULTS: Inertial sensor measurements distinguished paretic and non-paretic limbs with significant differences (P < 0.01) in movement duration, power, range of angular velocity, elevation, and smoothness (normalized jerk index and spectral arc length). Inertial sensor measurements correlated with functional clinical tests (Melbourne Assessment 2); movement duration and complexity (Higuchi fractal dimension) showed moderate to strong negative correlations with clinical measures of amplitude, accuracy, and fluency. CONCLUSION: Inertial sensor measurements reliably identify paresis and correlate with clinical measurements; they can therefore provide a complementary dimension of assessment in clinical practice and during clinical trials aimed at improving upper limb function.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Movimiento/fisiología , Paresia/fisiopatología , Extremidad Superior/fisiología , Adolescente , Fenómenos Biomecánicos/fisiología , Niño , Femenino , Humanos , Masculino , Paresia/diagnóstico
11.
Med Biol Eng Comput ; 55(10): 1773-1785, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28197810

RESUMEN

In daily life, a person's gait-an important marker for his/her health status-is usually assessed using inertial sensors fixed to lower limbs or trunk. Such sensor locations are not well suited for continuous and long duration measurements. A better location would be the wrist but with the drawback of the presence of perturbative movements independent of walking. The aim of this study was to devise and validate an algorithm able to accurately estimate walking cadence and speed for daily life walking in various environments based on acceleration measured at the wrist. To this end, a cadence likelihood measure was designed, automatically filtering out perturbative movements and amplifying the periodic wrist movement characteristic of walking. Speed was estimated using a piecewise linear model. The algorithm was validated for outdoor walking in various and challenging environments (e.g., trail, uphill, downhill). Cadence and speed were successfully estimated for all conditions. Overall median (interquartile range) relative errors were -0.13% (-1.72 2.04%) for instantaneous cadence and -0.67% (-6.52 6.23%) for instantaneous speed. The performance was comparable to existing algorithms for trunk- or lower limb-fixed sensors. The algorithm's low complexity would also allow a real-time implementation in a watch.


Asunto(s)
Velocidad al Caminar/fisiología , Caminata/fisiología , Aceleración , Adulto , Algoritmos , Femenino , Marcha/fisiología , Humanos , Masculino , Monitoreo Ambulatorio/métodos , Movimiento/fisiología
12.
J Sports Sci ; 31(11): 1251-60, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23560703

RESUMEN

This study introduces a novel approach for automatic temporal phase detection and inter-arm coordination estimation in front-crawl swimming using inertial measurement units (IMUs). We examined the validity of our method by comparison against a video-based system. Three waterproofed IMUs (composed of 3D accelerometer, 3D gyroscope) were placed on both forearms and the sacrum of the swimmer. We used two underwater video cameras in side and frontal views as our reference system. Two independent operators performed the video analysis. To test our methodology, seven well-trained swimmers performed three 300 m trials in a 50 m indoor pool. Each trial was in a different coordination mode quantified by the index of coordination. We detected different phases of the arm stroke by employing orientation estimation techniques and a new adaptive change detection algorithm on inertial signals. The difference of 0.2 ± 3.9% between our estimation and video-based system in assessment of the index of coordination was comparable to experienced operators' difference (1.1 ± 3.6%). The 95% limits of agreement of the difference between the two systems in estimation of the temporal phases were always less than 7.9% of the cycle duration. The inertial system offers an automatic easy-to-use system with timely feedback for the study of swimming.


Asunto(s)
Acelerometría/métodos , Destreza Motora , Movimiento , Natación , Análisis y Desempeño de Tareas , Adolescente , Adulto , Algoritmos , Femenino , Antebrazo , Humanos , Masculino , Sacro , Grabación en Video , Adulto Joven
13.
Sensors (Basel) ; 14(1): 443-57, 2013 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-24379049

RESUMEN

In order to distinguish dysfunctional gait, clinicians require a measure of reference gait parameters for each population. This study provided normative values for widely used parameters in more than 1,400 able-bodied adults over the age of 65. We also measured the foot clearance parameters (i.e., height of the foot above ground during swing phase) that are crucial to understand the complex relationship between gait and falls as well as obstacle negotiation strategies. We used a shoe-worn inertial sensor on each foot and previously validated algorithms to extract the gait parameters during 20 m walking trials in a corridor at a self-selected pace. We investigated the difference of the gait parameters between male and female participants by considering the effect of age and height factors. Besides; we examined the inter-relation of the clearance parameters with the gait speed. The sample size and breadth of gait parameters provided in this study offer a unique reference resource for the researchers.


Asunto(s)
Técnicas Biosensibles/métodos , Marcha/fisiología , Monitoreo Ambulatorio/métodos , Zapatos , Anciano , Algoritmos , Femenino , Pie/fisiología , Humanos , Cinética , Masculino , Caminata/fisiología
14.
Sensors (Basel) ; 12(10): 12927-39, 2012 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-23201978

RESUMEN

Monitoring the performance is a crucial task for elite sports during both training and competition. Velocity is the key parameter of performance in swimming, but swimming performance evaluation remains immature due to the complexities of measurements in water. The purpose of this study is to use a single inertial measurement unit (IMU) to estimate front crawl velocity. Thirty swimmers, equipped with an IMU on the sacrum, each performed four different velocity trials of 25 m in ascending order. A tethered speedometer was used as the velocity measurement reference. Deployment of biomechanical constraints of front crawl locomotion and change detection framework on acceleration signal paved the way for a drift-free integration of forward acceleration using IMU to estimate the swimmers velocity. A difference of 0.6 ± 5.4 cm · s(-1) on mean cycle velocity and an RMS difference of 11.3 cm · s(-1) in instantaneous velocity estimation were observed between IMU and the reference. The most important contribution of the study is a new practical tool for objective evaluation of swimming performance. A single body-worn IMU provides timely feedback for coaches and sport scientists without any complicated setup or restraining the swimmer's natural technique.


Asunto(s)
Rendimiento Atlético/fisiología , Movimiento/fisiología , Natación/fisiología , Grabación en Video/instrumentación , Aceleración , Acelerometría/instrumentación , Acelerometría/métodos , Adolescente , Adulto , Femenino , Humanos , Masculino , Aplicaciones Móviles , Monitoreo Ambulatorio/instrumentación , Estadística como Asunto/instrumentación , Estadística como Asunto/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...