Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Comput Biol Med ; 135: 104633, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34346318

RESUMEN

This paper introduces methods to estimate aspects of physical activity and sedentary behavior from three-axis accelerometer data collected with a wrist-worn device at a sampling rate of 32 [Hz] on adults with type 1 diabetes (T1D) in free-living conditions. In particular, we present two methods able to detect and grade activity based on its intensity and individual fitness as sedentary, mild, moderate or vigorous, and a method that performs activity classification in a supervised learning framework to predict specific user behaviors. Population results for activity level grading show multi-class average accuracy of 99.99%, precision of 98.0 ± 2.2%, recall of 97.9 ± 3.5% and F1 score of 0.9 ± 0.0. As for the specific behavior prediction, our best performing classifier, gave population multi-class average accuracy of 92.43 ± 10.32%, precision of 92.94 ± 9.80%, recall of 92.20 ± 10.16% and F1 score of 92.56 ± 9.94%. Our investigation showed that physical activity and sedentary behavior can be detected, graded and classified with good accuracy and precision from three-axial accelerometer data collected in free-living conditions on people with T1D. This is particularly significant in the context of automated glucose control systems for diabetes, in that the methods we propose have the potential to inform changes in treatment parameters in response to the intensity of physical activity, allowing patients to meet their glycemic targets.


Asunto(s)
Diabetes Mellitus Tipo 1 , Acelerometría , Adulto , Ejercicio Físico , Humanos , Conducta Sedentaria , Condiciones Sociales , Muñeca
3.
Diabetes Care ; 43(3): 607-615, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31937608

RESUMEN

OBJECTIVE: Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS: This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c <10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS: Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference -1.7% [95% CI -2.4, -1.0]; P < 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference -3.0% [95% CI -6.1, 0.1]; P < 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS: In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.


Asunto(s)
Técnicas Biosensibles/instrumentación , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Telemedicina/instrumentación , Adolescente , Adulto , Anciano , Técnicas Biosensibles/métodos , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea/efectos adversos , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Insulina Regular Humana/administración & dosificación , Insulina Regular Humana/efectos adversos , Masculino , Persona de Mediana Edad , Aplicaciones Móviles , Páncreas Artificial , Estados Unidos , Adulto Joven
4.
N Engl J Med ; 381(18): 1707-1717, 2019 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-31618560

RESUMEN

BACKGROUND: Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes. METHODS: In this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring. RESULTS: A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P<0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was >180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was <70 mg per deciliter or <54 mg per deciliter [3.0 mmol per liter]) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P<0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.).


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Adolescente , Adulto , Anciano , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diseño de Equipo , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Sistemas de Infusión de Insulina/efectos adversos , Masculino , Persona de Mediana Edad , Páncreas Artificial/efectos adversos , Adulto Joven
5.
Clin Transplant ; 33(10): e13719, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31545535

RESUMEN

BACKGROUND: Current therapy for Type 1 diabetes (T1D) is characterized by significant glucose variability (GV). Pancreas transplantation (PT) is performed in certain T1D patients with and without end-stage renal disease. To date, GV has been examined to a limited extent after PT. METHODS: We investigated GV using continuous glucose monitoring (CGM) 3-6 weeks after PT. RESULTS: Eleven patients had simultaneous kidney pancreas transplantation (SPK), nine pancreas after kidney (PAK), and six pancreas transplantation alone (PTA). Mean CGM showed no difference between SPK, 126.5 ± 13.9, PAK 119.9 ± 12.8, and PTA 131.1 ± 29 mg/dL (P value .6). Percentage of time in range (TIR, 70-180 mg/dL) was 92% for SPK, 93.4% in PAK, and 88.5% in PTA with only 0.3%, 1.5%, and 0.3% of time <70 mg/dL. Percentage >180 mg/dL was 7.9% for SPK, 4.9% PAK, and 11% in PTA. Other measures of GV were similar in the three cohorts. In six patients, CGM was performed before and after PT and improved significantly. GV was also better compared with a matched cohort of T1D patients. CONCLUSIONS: All 3 types of PT resulted in excellent glucose control 3-6 weeks post-procedure. CGM outcomes represent an important objective outcome after PT.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/estadística & datos numéricos , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/cirugía , Hiperglucemia/prevención & control , Hipoglucemia/prevención & control , Trasplante de Páncreas/métodos , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/patología , Femenino , Estudios de Seguimiento , Humanos , Hiperglucemia/diagnóstico , Hiperglucemia/metabolismo , Hipoglucemia/diagnóstico , Hipoglucemia/metabolismo , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo
6.
Curr Diab Rep ; 18(10): 88, 2018 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-30159816

RESUMEN

PURPOSE OF REVIEW: To provide a current review of closed-loop insulin delivery or artificial pancreas (AP) as therapy for people with type 1 diabetes mellitus (T1D) RECENT FINDINGS: The Medtronic Minimed 670G AP system has been in use in clinical practice since March 2017. Currently, Medtronic is conducting a large randomized clinical trial to evaluate its efficacy further in T1D. Simultaneously, the NIH has funded four research consortia to accelerate progress to approval of other AP and decision support systems. Several research groups are currently developing next-generation AP systems, with a number of companies moving toward releasing closed-loop systems in the future. AP systems are also being tested in select populations such as hypoglycemia-unaware T1D and pregnant T1D. AP research is rapidly advancing. The clinical range of AP will be expanded in the next decade.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Infusión de Insulina , Glucemia/metabolismo , Ensayos Clínicos como Asunto , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/terapia , Humanos , Hipoglucemiantes/uso terapéutico , Páncreas Artificial
7.
Diabetes Care ; 40(12): 1719-1726, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29030383

RESUMEN

OBJECTIVE: Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. RESEARCH DESIGN AND METHODS: Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A1c (HbA1c). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. RESULTS: Twenty-nine patients completed the trial. HbA1c, 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (-0.3, 95% CI -0.5 to -0.2, P < 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (-3.1, 95% CI -4.1 to -2.1, P < 0.001) and overnight from 4.1 to 1.1% (-3.1, 95% CI -4.2 to -1.9, P < 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. CONCLUSIONS: Use of our novel adaptive AP yielded significant reductions in HbA1c and hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/metabolismo , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Femenino , Humanos , Hipoglucemia/tratamiento farmacológico , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Páncreas Artificial
8.
Diabetes Technol Ther ; 19(10): 572-579, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-29045170

RESUMEN

BACKGROUND: Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS: Retrospective single center cohort study, we analyzed in-hospital glucose measurements to assess GV in 736 hospitalized patients in different units over a consecutive 5-year period of time. GV was assessed by mean blood glucose (BG), Average daily risk range (ADRR), high BG index, and low BG index. To place our findings in context, we conducted a systematic review using Cochrane collaboration methodology to critically analyze current published literature on GV in hospitalized T1D patients. RESULTS: Overall, glycemic control was suboptimal with mean BG 183 ± 51.5 mg/dL and mean ADRR 35 with only 16% patients being categorized as low risk (ADRR <20) for hypo or hyperglycemia. Patients admitted in medical units had mean BG of 194.4 ± 42.8 mg/dL (95% CI = 101.2-346.6) and ADRR of 39.4 ± 16 (95% CI = 1.3-118.7), which were higher than the patients admitted in the surgical units (mean BG 168.1 ± 35.7 (95% CI = 74.8-301.8) and mean ADRR (28.8 ± 13.1 [95% CI = 0.3-93.1]). For the systematic review, initial search yielded 2336 studies for screening, however, none of them had data specific for T1D. CONCLUSION: GV is high in hospitalized T1D patients admitted at our tertiary care center. Review of the literature shows paucity of data regarding GV in hospitalized patients with T1D.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Pacientes Internos , Adulto , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
10.
J Clin Endocrinol Metab ; 102(10): 3674-3682, 2017 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-28666360

RESUMEN

Context: Closed-loop control (CLC) for the management of type 1 diabetes (T1D) is a novel method for optimizing glucose control, and strategies for individualized implementation are being developed. Objective: To analyze glycemic control in an overnight CLC system designed to "reset" the patient to near-normal glycemic targets every morning. Design: Randomized, crossover, multicenter clinical trial. Participants: Forty-four subjects with T1D requiring insulin pump therapy. Intervention: Sensor-augmented pump therapy (SAP) at home vs 5 nights of CLC (active from 23:00 to 07:00) in a supervised outpatient setting (research house or hotel), with a substudy of 5 nights of CLC subsequently at home. Main Outcome Measure: The percentage of time spent in the target range (70 to 180 mg/dL measured using a continuous glucose monitor). Results: Forty subjects (age, 45.5 ± 9.5 years; hemoglobin A1c, 7.4% ± 0.8%) completed the study. The time in the target range (70 to 180 mg/dL) significantly improved in CLC vs SAP over 24 hours (78.3% vs 71.4%; P = 0.003) and overnight (85.7% vs 67.6%; P < 0.001). The time spent in a hypoglycemic range (<70 mg/dL) decreased significantly in the CLC vs SAP group over 24 hours (2.5% vs 4.3%; P = 0.002) and overnight (0.9% vs 3.2%; P < 0.001). The mean glucose level at 07:00 was lower with CLC than with SAP (123.7 vs 145.3 mg/dL; P < 0.001). The substudy at home, involving 10 T1D subjects, showed similar trends with an increased time in target (70 to 180 mg/dL) overnight (75.2% vs 62.2%; P = 0.07) and decreased time spent in the hypoglycemic range (<70 mg/dL) overnight in CLC vs SAP (0.6% vs 3.7%; P = 0.03). Conclusion: Overnight-only CLC increased the time in the target range over 24 hours and decreased the time in hypoglycemic range over 24 hours in a supervised outpatient setting. A pilot extension study at home showed a similar nonsignificant trend.


Asunto(s)
Glucemia/efectos de los fármacos , Ritmo Circadiano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Adulto , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Ritmo Circadiano/efectos de los fármacos , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Femenino , Hemoglobina Glucada , Humanos , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Masculino , Persona de Mediana Edad , Adulto Joven
12.
J Clin Endocrinol Metab ; 101(5): 1954-62, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26930181

RESUMEN

CONTEXT: Early postprandial hyperglycemia and delayed hypoglycemia remain major problems in current management of type 1 diabetes (T1D). OBJECTIVE: Our objective was to investigate the effects of pramlintide, known to suppress glucagon and delay gastric emptying, on postprandial glucose fluxes in T1D. DESIGN: This was a single-center, inpatient, randomized, crossover study. PATIENTS: Twelve patients with T1D who completed the study were analyzed. INTERVENTIONS: Subjects were studied on two occasions with or without pramlintide. Triple tracer mixed-meal method and oral minimal model were used to estimate postprandial glucose turnover and insulin sensitivity (SI). Integrated liver insulin sensitivity was calculated based on glucose turnover. Plasma glucagon and insulin were measured. MAIN OUTCOME MEASURE: Glucose turnover and SI were the main outcome measures. RESULTS: With pramlintide, 2-hour postprandial glucose, insulin, glucagon, glucose turnover, and SI indices showed: plasma glucose excursions were reduced (difference in incremental area under the curve [iAUC], 444.0 mMmin, P = .0003); plasma insulin concentrations were lower (difference in iAUC, 7642.0 pMmin; P = .0099); plasma glucagon excursions were lower (difference in iAUC, 1730.6 pg/mlmin; P = .0147); meal rate of glucose appearance was lower (difference in iAUC: 1196.2 µM/kg fat free mass [FFM]; P = .0316), endogenous glucose production was not different (difference in iAUC: -105.5 µM/kg FFM; P = .5842), rate of glucose disappearance was lower (difference in iAUC: 1494.2 µM/kg FFM; P = .0083). SI and liver insulin sensitivity were not different between study visits (P > .05). CONCLUSIONS: Inhibition of glucagon and gastric emptying delaying reduced 2-hour prandial glucose excursions in T1D by delaying meal rate of glucose appearance.


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Resistencia a la Insulina/fisiología , Polipéptido Amiloide de los Islotes Pancreáticos/uso terapéutico , Periodo Posprandial/efectos de los fármacos , Adulto , Anciano , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
14.
J Diabetes Sci Technol ; 9(6): 1208-16, 2015 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-26481641

RESUMEN

Physical activity is an important determinant of glucose variability in type 1 diabetes (T1D). It has been incorporated as a nonglucose input into closed-loop control (CLC) protocols for T1D during the last 4 years mainly by 3 research groups in single center based controlled clinical trials involving a maximum of 18 subjects in any 1 study. Although physical activity data capture may have clinical benefit in patients with T1D by impacting cardiovascular fitness and optimal body weight achievement and maintenance, limited number of such studies have been conducted to date. Clinical trial registries provide information about a single small sample size 2 center prospective study incorporating physical activity data input to modulate closed-loop control in T1D that are seeking to build on prior studies. We expect an increase in such studies especially since the NIH has expanded support of this type of research with additional grants starting in the second half of 2015. Studies (1) involving patients with other disorders that have lasted 12 weeks or longer and tracked physical activity and (2) including both aerobic and resistance activity may offer insights about the user experience and device optimization even as single input CLC heads into real-world clinical trials over the next few years and nonglucose input is introduced as the next advance.


Asunto(s)
Actigrafía/instrumentación , Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Ejercicio Físico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Actividad Motora , Páncreas Artificial , Algoritmos , Biomarcadores/sangre , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/fisiopatología , Diseño de Equipo , Humanos , Sistemas de Infusión de Insulina , Valor Predictivo de las Pruebas , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Resultado del Tratamiento
15.
J Clin Endocrinol Metab ; 100(10): 3878-86, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26204135

RESUMEN

CONTEXT: Closed-loop control (CLC) relies on an individual's open-loop insulin pump settings to initialize the system. Optimizing open-loop settings before using CLC usually requires significant time and effort. OBJECTIVE: The objective was to investigate the effects of a one-time algorithmic adjustment of basal rate and insulin to carbohydrate ratio open-loop settings on the performance of CLC. DESIGN: This study reports a multicenter, outpatient, randomized, crossover clinical trial. PATIENTS: Thirty-seven adults with type 1 diabetes were enrolled at three clinical sites. INTERVENTIONS: Each subject's insulin pump settings were subject to a one-time algorithmic adjustment based on 1 week of open-loop (i.e., home care) data collection. Subjects then underwent two 27-hour periods of CLC in random order with either unchanged (control) or algorithmic adjusted basal rate and carbohydrate ratio settings (adjusted) used to initialize the zone-model predictive control artificial pancreas controller. Subject's followed their usual meal-plan and had an unannounced exercise session. MAIN OUTCOMES AND MEASURES: Time in the glucose range was 80-140 mg/dL, compared between both arms. RESULTS: Thirty-two subjects completed the protocol. Median time in CLC was 25.3 hours. The median time in the 80-140 mg/dl range was similar in both groups (39.7% control, 44.2% adjusted). Subjects in both arms of CLC showed minimal time spent less than 70 mg/dl (median 1.34% and 1.37%, respectively). There were no significant differences more than 140 mg/dL. CONCLUSIONS: A one-time algorithmic adjustment of open-loop settings did not alter glucose control in a relatively short duration outpatient closed-loop study. The CLC system proved very robust and adaptable, with minimal (<2%) time spent in the hypoglycemic range in either arm.


Asunto(s)
Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Adulto , Anciano , Automonitorización de la Glucosa Sanguínea , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Femenino , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
16.
Am J Physiol Endocrinol Metab ; 308(12): E1106-15, 2015 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-25898950

RESUMEN

To determine the effects of exercise on postprandial glucose metabolism and insulin action in type 1 diabetes (T1D), we applied the triple tracer technique to study 16 T1D subjects on insulin pump therapy before, during, and after 75 min of moderate-intensity exercise (50% V̇o2max) that started 120 min after a mixed meal containing 75 g of labeled glucose. Prandial insulin bolus was administered as per each subject's customary insulin/carbohydrate ratio adjusted for meal time meter glucose and the level of physical activity. Basal insulin infusion rates were not altered. There were no episodes of hypoglycemia during the study. Plasma dopamine and norepinephrine concentrations rose during exercise. During exercise, rates of endogenous glucose production rose rapidly to baseline levels despite high circulating insulin and glucose concentrations. Interestingly, plasma insulin concentrations increased during exercise despite no changes in insulin pump infusion rates, implying increased mobilization of insulin from subcutaneous depots. Glucagon concentrations rose before and during exercise. Therapeutic approaches for T1D management during exercise will need to account for its effects on glucose turnover, insulin mobilization, glucagon, and sympathetic response and possibly other blood-borne feedback and afferent reflex mechanisms to improve both hypoglycemia and hyperglycemia.


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Ejercicio Físico/fisiología , Insulina/metabolismo , Periodo Posprandial , Adolescente , Adulto , Anciano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Prueba de Esfuerzo , Femenino , Vaciamiento Gástrico , Humanos , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...