Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 158
Filtrar
1.
Bioact Mater ; 38: 95-108, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38699241

RESUMEN

Androgenetic alopecia (AGA), the most prevalent clinical hair loss, lacks safe and effective treatments due to downregulated angiogenic genes and insufficient vascularization in the perifollicular microenvironment of the bald scalp in AGA patients. In this study, a hyaluronic acid (HA) based hydrogel-formed microneedle (MN) was designed, referred to as V-R-MNs, which was simultaneously loaded with vascular endothelial growth factor (VEGF) and the novel hair loss drug Ritlecitinib, the latter is encapsulated in slowly biodegradable polyhydroxyalkanoates (PHAs) nanoparticles (R-PHA NPs) for minimally invasive AGA treatment. The integration of HA based hydrogel alongside PHA nanoparticles significantly bolstered the mechanical characteristics of microneedles and enhanced skin penetration efficiency. Due to the biosafety, mechanical strength, and controlled degradation properties of HA hydrogel formed microneedles, V-R-MNs can effectively penetrate the skin's stratum corneum, facilitating the direct delivery of VEGF and Ritlecitinib in a minimally invasive, painless and long-term sustained release manner. V-R-MNs not only promoted angiogenesis and improve the immune microenvironment around the hair follicle to promote the proliferation and development of hair follicle cells, but also the application of MNs to the skin to produce certain mechanical stimulation could also promote angiogenesis. In comparison to the clinical drug minoxidil for AGA treatment, the hair regeneration effect of V-R-MN in AGA model mice is characterized by a rapid onset of the anagen phase, improved hair quality, and greater coverage. This introduces a new, clinically safer, and more efficient strategy for AGA treatment, and serving as a reference for the treatment of other related diseases.

2.
Circ Cardiovasc Imaging ; 17(4): e016155, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38626098

RESUMEN

BACKGROUND: Computed tomography (CT) fractional flow reserve (FFR)-derived functional SYNTAX score (FSSCT-FFR) is a valuable method for guiding treatment strategy in patients with multivessel coronary artery disease. Dynamic CT myocardial perfusion imaging (CT-MPI) demonstrates higher diagnostic accuracy than CT-FFR in identifying hemodynamically significant coronary artery disease. We aimed to evaluate the feasibility of CT-MPI-derived FSS (FSSCT-MPI) with reference to invasive FSS. METHODS: In this retrospective study, patients with multivessel coronary artery disease who underwent dynamic CT-MPI+ coronary CT angiography and invasive coronary angiography or FFR within 4 weeks were consecutively included. Invasive (FSSinvasive) and noninvasive FSS (FSSCT-MPI and FSSCT-FFR) were calculated by an online calculator, which assigned points to lesions with hemodynamic significance (defined as FFRinvasive ≤0.80, invasive coronary angiography diameter stenosis ≥90%, CT-FFR ≤0.80, and myocardial ischemia on CT-MPI). Weighted κ value and net reclassification index were calculated to determine the consistency and incremental discriminatory power of FSSCT-MPI. Receiver operating characteristic curve analysis was used for the comparison of FSSCT-MPI and FSSCT-FFR in detecting intermediate- to high-risk patients. RESULTS: A total of 119 patients (96 men; 64.6±10.6 years) with 305 obstructive lesions were included. The average FSSCT-MPI, FSSCT-FFR, and FSSinvasive were 15.58±13.03, 16.18±13.30, and 13.11±12.22, respectively. The agreement on risk classification based on the FSSCT-MPI tertiles was good (weighted κ, 0.808). With reference to FSSinvasive, FSSCT-MPI correctly reclassified 27 (22.7%) patients from the intermediate- to high SYNTAX score group to the low-score group (net reclassification index, 0.30; P<0.001). In patients with severe calcification, FSSCT-MPI had better diagnostic value than FSSCT-FFR in detecting intermediate- to high-risk patients when compared with FSSinvasive (area under the curve, 0.976 versus 0.884; P<0.001). CONCLUSIONS: Noninvasive FSS derived from CT-MPI is feasible and has strong concordance with FSSinvasive. It allows accurate categorization of FSS in patients with multivessel coronary artery disease, in particular with severe calcification.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Masculino , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Estudios Retrospectivos , Estudios de Factibilidad , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria/métodos , Angiografía por Tomografía Computarizada/métodos , Valor Predictivo de las Pruebas
3.
Innovation (Camb) ; 5(3): 100618, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38638583

RESUMEN

Extinction selectivity determines the direction of macroevolution, especially during mass extinction; however, its driving mechanisms remain poorly understood. By investigating the physiological selectivity of marine animals during the Permian-Triassic mass extinction, we found that marine clades with lower O2-carrying capacity hemerythrin proteins and those relying on O2 diffusion experienced significantly greater extinction intensity and body-size reduction than those with higher O2-carrying capacity hemoglobin or hemocyanin proteins. Our findings suggest that animals with high O2-carrying capacity obtained the necessary O2 even under hypoxia and compensated for the increased energy requirements caused by ocean acidification, which enabled their survival during the Permian-Triassic mass extinction. Thus, high O2-carrying capacity may have been crucial for the transition from the Paleozoic to the Modern Evolutionary Fauna.

4.
Int J Cardiovasc Imaging ; 40(4): 921-930, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38448705

RESUMEN

The relationship between left ventricular (LV) torsion and myocardial fibrosis (MF) in hypertrophic cardiomyopathy (HCM) patients with preserved ejection fraction was still not well understood. New developments in cardiac magnetic resonance (CMR) enable a much fuller assessment of cardiac characteristics. This study sought to assess the impact of HCM on myocardial function as assessed by LV torsion and its relationship with MF. HCM (n = 79) and healthy controls (n = 40) underwent CMR. According to whether there was late gadolinium enhancement (LGE), patients were divided into LGE+ group and LGE- group. LV torsion and torsion rate were measured by CMR feature-tracking (CMR-FT). MF was quantitatively evaluated through LGE imaging. LGE was present in 44 patients (56%). Compared with healthy controls, torsion increased in the LGE- group (P < 0.001). Compared with LGE+ group, torsion was higher in the LGE- group (P < 0.001). There was no significant difference in torsion between LGE+ group and healthy controls. Correlation analysis showed that torsion was correlated with LGE% (r = - 0.443) and LGE mass (r = - 0.435) respectively. On multivariable logistic regression analysis, LV torsion was the only feature that was independently associated with the presence of LGE (OR 0.130; 95% CI 0.040 to 0.420, P = 0.01). The best torsion value associated with MF was 1.91 (sensitivity 60.0%, specificity 77.3%, AUC = 0.733). In HCM patients with preserved ejection fraction, CMR-FT derived LV torsion analysis holds promise for myocardial fibrosis detection.


Asunto(s)
Cardiomiopatía Hipertrófica , Medios de Contraste , Fibrosis , Imagen por Resonancia Cinemagnética , Miocardio , Valor Predictivo de las Pruebas , Volumen Sistólico , Torsión Mecánica , Función Ventricular Izquierda , Humanos , Masculino , Femenino , Cardiomiopatía Hipertrófica/fisiopatología , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/complicaciones , Persona de Mediana Edad , Miocardio/patología , Adulto , Anciano , Estudios de Casos y Controles , Estudios Retrospectivos , Reproducibilidad de los Resultados , Fenómenos Biomecánicos
5.
Int J Biol Macromol ; 265(Pt 1): 130649, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38453121

RESUMEN

Bone Morphogenetic Protein 4 (BMP4) is crucial for bone and cartilage tissue regeneration, essential in medical tissue engineering, cosmetology, and aerospace. However, its cost and degradation susceptibility pose significant clinical challenges. To enhance its osteogenic activity while reducing dosage and administration frequency, we developed a novel long-acting BMP4 delivery system using poly(3-hydroxybutyrate-co-3-hydroxyvalerate-co-3-hydroxyhexanoate) (PBVHx) nanoparticles with soybean lecithin-modified BMP4 (sBP-NPs). These nanoparticles promote directed osteogenic differentiation of human bone marrow mesenchymal stem cells (hBMSCs) through sustained BMP4 release. sBP-NPs exhibited uniform size (100-200 nm) and surface charges, with higher BMP4 entrapment efficiency (82.63 %) compared to controls. After an initial burst release within 24 h, sBP-NPs achieved 80 % cumulative BMP4 release within 20 days, maintaining levels better than control BP-NPs with unmodified BMP4. Co-incubation and nanoparticle uptake experiments confirmed excellent biocompatibility of sBP-NPs, promoting hBMSC differentiation towards osteogenic lineage with increased expression of type I collagen, calcium deposition, and ALP activity (> 20,000 U/g protein) compared to controls. Moreover, hBMSCs treated with sBP-NPs exhibited heightened expression of osteogenic genetic markers, surpassing control groups. Hence, this innovative strategy of sustained BMP4 release from sBP-NPs holds potential to revolutionize bone regeneration in minimally invasive surgery, medical cosmetology or space environments.


Asunto(s)
Células Madre Mesenquimatosas , Nanopartículas , Humanos , Osteogénesis/genética , Proteína Morfogenética Ósea 4/genética , Preparaciones de Acción Retardada/farmacología , Diferenciación Celular , Células de la Médula Ósea/metabolismo , Células Cultivadas
6.
Adv Mater ; : e2312570, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38359909

RESUMEN

Flexible photo-thermoelectric (PTE) devices have great application prospects in the fields of solar energy conversion, ultrabroadband light detection, etc. A suitable manufacturing process to avoid the substrate effects as well as to create a narrow transition area between p-n modules for high-performance freestanding flexible PTE devices is highly desired. Herein, an automated laser fabrication (ALF) method is reported to construct the PTE devices with rylene-diimide-doped n-type single-walled carbon nanotube (SWCNT) films. The wet-compressing approach is developed to improve the thermoelectric power factors and figure of merit (ZT) of the SWCNT hybrid films. Then, the films are cut and patterned automatically to make PTE devices with various structures by the proposed ALF method. The freestanding PTE device with a narrow transition area of ≈2-3 µm between the p and n modules exhibits a high-power density of 0.32 µW cm-2 under the light of 200 mW cm-2 , which is among the highest level for freestanding-film-based PTE devices. The results pave the way for the automatic production process of PTE devices for green power generation and ultrabroadband light detection.

7.
Nano Lett ; 24(3): 983-992, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38206182

RESUMEN

On-chip polarization detectors have attracted extensive research interest due to their filterless and ultracompact architecture. However, their polarization-dependent photoresponses cannot be dynamically adjusted, hindering the development toward intelligence. Here, we propose dynamically reconfigurable polarimetry based on in-sensor differentiation of two self-powered photoresponses with orthogonal polarization dependences and tunable responsivities. Such a device can be electrostatically configured in an ultrahigh polarization extinction ratio (PER) mode, where the PER tends to infinity, a Stokes parameter direct sensing mode, where the photoresponse is proportional to S1 or S2 with high accuracy (RMSES1 = 1.5%, RMSES2 = 2.0%), or a background suppressing mode, where the target-background polarization contrast is singularly enhanced. Moreover, the device achieves a polarization angle sensitivity of 0.51 mA·W-1·degree-1 and a specific polarization angle detectivity of 2.8 × 105 cm·Hz1/2·W·degree-1. This scheme is demonstrated throughout the near-to-long-wavelength infrared range, and it will bring a leap for next-generation on-chip polarimeters.

8.
Radiology ; 309(2): e231149, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37962501

RESUMEN

Background CT is helpful in guiding the revascularization of chronic total occlusion (CTO), but manual prediction scores of percutaneous coronary intervention (PCI) success have challenges. Deep learning (DL) is expected to predict success of PCI for CTO lesions more efficiently. Purpose To develop a DL model to predict guidewire crossing and PCI outcomes for CTO using coronary CT angiography (CCTA) and evaluate its performance compared with manual prediction scores. MATERIALS AND METHODS: Participants with CTO lesions were prospectively identified from one tertiary hospital between January 2018 and December 2021 as the training set to develop the DL prediction model for PCI of CTO, with fivefold cross validation. The algorithm was tested using an external test set prospectively enrolled from three tertiary hospitals between January 2021 and June 2022 with the same eligibility criteria. All participants underwent preprocedural CCTA within 1 month before PCI. The end points were guidewire crossing within 30 minutes and PCI success of CTO.Results A total of 534 participants (mean age, 57.7 years ± 10.8 [SD]; 417 [78.1%] men) with 565 CTO lesions were included. In the external test set (186 participants with 189 CTOs), the DL model saved 85.0% of the reconstruction and analysis time of manual scores (mean, 73.7 seconds vs 418.2-466.9 seconds) and had higher accuracy than manual scores in predicting guidewire crossing within 30 minutes (DL, 91.0%; CT Registry of Chronic Total Occlusion Revascularization, 61.9%; Korean Multicenter CTO CT Registry [KCCT], 68.3%; CCTA-derived Multicenter CTO Registry of Japan (J-CTO), 68.8%; P < .05) and PCI success (DL, 93.7%; KCCT, 74.6%; J-CTO, 75.1%; P < .05). For DL, the area under the receiver operating characteristic curve was 0.97 (95% CI: 0.89, 0.99) for the training test set and 0.96 (95% CI: 0.90, 0.98) for the external test set. Conclusion The DL prediction model accurately predicted the percutaneous recanalization outcomes of CTO lesions and increased the efficiency of noninvasively grading the difficulty of PCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Pundziute-do Prado in this issue.


Asunto(s)
Aprendizaje Profundo , Intervención Coronaria Percutánea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Tomografía Computarizada por Rayos X , Anciano , Estudios Multicéntricos como Asunto
10.
Korean J Radiol ; 24(11): 1081-1092, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37899519

RESUMEN

OBJECTIVE: To investigate the incidence of microvascular myocardial ischemia in diabetic patients without obstructive coronary artery disease (CAD) and its relationship with angina. MATERIALS AND METHODS: Diabetic patients and an intermediate-to-high pretest probability of CAD were prospectively enrolled. Non-diabetic patients but with an intermediate-to-high pretest probability of CAD were retrospectively included as controls. The patients underwent dynamic computed tomography-myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) to quantify coronary stenosis, myocardial blood flow (MBF), and extracellular volume (ECV). The proportion of patients with microvascular myocardial ischemia, defined as any myocardial segment with a mean MBF ≤ of 100 mL/min/100 mL, in patients without obstructive CAD (Coronary Artery Disease-Reporting and Data System [CAD-RADS] grade 0-2 on CCTA) was determined. Various quantitative parameters of the patients with and without diabetes without obstructive CAD were compared. Multivariable analysis was used to determine the association between microvascular myocardial ischemia and angina symptoms in diabetic patients without obstructive CAD. RESULTS: One hundred and fifty-two diabetic patients (mean age: 59.7 ± 10.7; 77 males) and 266 non-diabetic patients (62.0 ± 12.3; 167 males) were enrolled; CCTA revealed 113 and 155 patients without obstructive CAD, respectively. For patients without obstructive CAD, the mean global MBF was significantly lower for those with diabetes than for those without (152.8 mL/min/100 mL vs. 170.4 mL/min/100 mL, P < 0.001). The mean ECV was significantly higher for diabetic patients (27.2% vs. 25.8%, P = 0.009). Among the patients without obstructive CAD, the incidence of microvascular myocardial ischemia (36.3% [41/113] vs. 10.3% [16/155], P < 0.001) and interstitial fibrosis (69.9% [79/113] vs. 33.3% [8/24], P = 0.001) were significantly higher in diabetic patients than in the controls. The presence of microvascular myocardial ischemia was independently associated with angina symptoms (adjusted odds ratio = 3.439, P = 0.037) in diabetic patients but without obstructive CAD. CONCLUSION: Dynamic CT-MPI + CCTA revealed a high incidence of microvascular myocardial ischemia in diabetic patients without obstructive CAD. Microvascular myocardial ischemia is strongly associated with angina.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Diabetes Mellitus , Isquemia Miocárdica , Imagen de Perfusión Miocárdica , Masculino , Humanos , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Estudios Retrospectivos , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/epidemiología , Angiografía Coronaria/métodos , Angiografía por Tomografía Computarizada , Diabetes Mellitus/epidemiología , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/epidemiología
11.
Sci Adv ; 9(35): eadg7679, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37647393

RESUMEN

The geological record of marine animal biodiversity reflects the interplay between changing rates of speciation versus extinction. Compared to mass extinctions, background extinctions have received little attention. To disentangle the different contributions of global climate state, continental configuration, and atmospheric oxygen concentration (pO2) to variations in background extinction rates, we drive an animal physiological model with the environmental outputs from an Earth system model across intervals spanning the past 541 million years. We find that climate and continental configuration combined to make extinction susceptibility an order of magnitude higher during the Early Paleozoic than during the rest of the Phanerozoic, consistent with extinction rates derived from paleontological databases. The high extinction susceptibility arises in the model from the limited geographical range of marine organisms. It stands even when assuming present-day pO2, suggesting that increasing oxygenation through the Paleozoic is not necessary to explain why extinction rates apparently declined with time.


Asunto(s)
Biodiversidad , Clima , Animales , Bases de Datos Factuales , Planeta Tierra , Extinción Biológica
12.
Small ; 19(52): e2304266, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37649184

RESUMEN

Generating sufficient power from waste heat is one of the most important things for thermoelectric (TE) techniques in numerous practical applications. The output power density of an organic thermoelectric generator (OTEG) is proportional to the power factors (PFs) and the electrical conductivities of organic materials. However, it is still challenging to have high PFs over 1 mW m-1  K-2 in free-standing films together with high electrical conductivities over 1000 S cm-1 . Herein, densifying multi-walled carbon nanotube (MWCNT) films would increase their electrical conductivity dramatically up to over 10 000 S cm-1 with maintained high Seebeck coefficients >60 µV K-1 , thus leading to ultrahigh PFs of 7.25 and 4.34 mW m-1  K-2 for p- and n-type MWCNT films, respectively. In addition, it is interesting to notice that the electrical properties increase faster than the thermal conductivities, resulting in enhanced ZT of 3.6 times in MWCNT films. An OTEG made of compressed MWCNT films is fabricated to demonstrate the heat-to-electricity conversion ability, which exhibits a high areal output power of ∼12 times higher than that made of pristine MWCNT films. This work demonstrates an effective way to high-performance nanowire/nanoparticle-based TE materials such as printable TE materials comprised of nanowires/nanoparticles.

13.
ACS Appl Mater Interfaces ; 15(28): 34215-34229, 2023 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-37413794

RESUMEN

The icing of transmission conductor seriously threatens the safe operation of power grids. Slippery lubricant-infused porous surface (SLIPS) has shown great potential for anti-icing applications. However, aluminum stranded conductors have complex surfaces, and the current SLIPSs are almost prepared and studied on small flat plates. Herein, the construction of SLIPS on the conductor was realized through anodic oxidation and the anti-icing mechanism of the slippery conductor was studied. Compared to the untreated conductor, the SLIPS-conductor reduces the icing weight by 77% in the glaze icing test and shows very low ice-adhesion strength (7.0 kPa). The excellent anti-icing performance of the slippery conductor is attributed to the droplet impact dynamics, icing delay, and lubricant stability. The dynamic behavior of water droplets is most affected by the complex shape of the conductor surface. Specifically, the impact of the droplet on the conductor surface is asymmetric and the droplet can slide along the depression in low-temperature and high-humidity environments. The stable lubricant of SLIPS increases both the nucleation energy barriers and the heat transfer resistance, which greatly delays the freezing time of droplets. Besides, the nanoporous substrate, the compatibility of the substrate with the lubricant, and the lubricant characteristics contribute to the lubricant stability. This work provides theoretical and experimental guidance on anti-icing strategies for transmission lines.

14.
Biomater Sci ; 11(18): 6013-6034, 2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37522312

RESUMEN

Polyhydroxyalkanoates (PHAs) are a family of natural microbial biopolyesters with the same basic chemical structure and diverse side chain groups. Based on their excellent biodegradability, biocompatibility, thermoplastic properties and diversity, PHAs are highly promising medical biomaterials and elements of medical devices for applications in tissue engineering and drug delivery. However, due to the high cost of biotechnological production, most PHAs have yet to be applied in the clinic and have only been studied at laboratory scale. This review focuses on the biosynthesis, diversity, physical properties, biodegradability and biosafety of PHAs. We also discuss optimization strategies for improved microbial production of commercial PHAs via novel synthetic biology tools. Moreover, we also systematically summarize various medical devices based on PHAs and related design approaches for medical applications, including tissue repair and drug delivery. The main degradation product of PHAs, 3-hydroxybutyrate (3HB), is recognized as a new functional molecule for cancer therapy and immune regulation. Although PHAs still account for only a small percentage of medical polymers, up-and-coming novel medical PHA devices will enter the clinical translation stage in the next few years.


Asunto(s)
Polihidroxialcanoatos , Polihidroxialcanoatos/química , Materiales Biocompatibles/química , Ingeniería de Tejidos , Sistemas de Liberación de Medicamentos
15.
Eur Radiol ; 33(11): 8191-8202, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37286790

RESUMEN

OBJECTIVES: To compare the financial and clinical outcomes of CT myocardial perfusion imaging (CT-MPI) + coronary CT angiography (CCTA)-guided versus CCTA-guided strategy in patients suspected of chronic coronary syndrome (CCS). MATERIALS AND METHODS: This study retrospectively included consecutive patients suspected of CCS and referred for CT-MPI+CCTA-guided and CCTA-guided treatment. The details of medical costs within 3 months after index imaging, including downstream invasive procedures, hospitalization, and medications, were recorded. All patients were followed up for major adverse cardiac events (MACE) at a median time of 22 months. RESULTS: A total of 1335 patients (559 in the CT-MPI+CCTA group and 776 in the CCTA group) were finally included. In the CT-MPI+CCTA group, 129 patients (23.1%) underwent ICA and 95 patients (17.0%) received revascularization. In the CCTA group, 325 patients (41.9%) underwent ICA whereas 194 patients (25.0%) received revascularization. An addition of CT-MPI in the evaluation strategy remarkably reduced the healthcare expenditure, compared with CCTA-guided strategy (USD 1441.36 vs. USD 232.91, p < 0.001). After adjustment for potential cofounders after inverse probability weighting, the CT-MPI+CCTA strategy was significantly associated with lower medical expenditure [adjusted cost ratio (95% CI) for total costs: 0.77 (0.65-0.91), p < 0.001]. In addition, there was no significant difference regarding the clinical outcome between the two groups (adjusted HR= 0.97; p = 0.878). CONCLUSIONS: CT-MPI+CCTA considerably reduced medical expenditures in patients suspected of CCS, compared to the CCTA strategy alone. Moreover, CT-MPI+CCTA led to a lower rate of invasive procedures with a similar long-term prognosis. CLINICAL RELEVANCE STATEMENT: CT myocardial perfusion imaging + coronary CT angiography-guided strategy reduced medical expenditure and invasive procedure rate. KEY POINTS: • CT-MPI+CCTA strategy yielded significantly lower medical expenditure than did the CCTA strategy alone in patients with suspected CCS. • After adjustment for potential confounders, the CT-MPI+CCTA strategy was significantly associated with lower medical expenditure. • No significant difference was observed regarding the long-term clinical outcome between the two groups.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Humanos , Angiografía por Tomografía Computarizada/métodos , Imagen de Perfusión Miocárdica/métodos , Estudios Retrospectivos , Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Valor Predictivo de las Pruebas
16.
Adv Mater ; 35(33): e2302919, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37352335

RESUMEN

Highly conductive hydrogels with biotissue-like mechanical properties are of great interest in the emerging field of hydrogel bioelectronics due to their good biocompatibility, deformability, and stability. Fully polymeric hydrogels may exhibit comparable Young's modulus to biotissues. However, most of these filler-free hydrogels have a low electrical conductivity of <10 S cm-1 , which limits their wide applications of them in digital circuits or bioelectronic devices. In this work, a series of metal-halides-doped poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) hydrogels with an ultrahigh electrical conductivity up to 547 S cm-1 is reported, which is 1.5 times to 104 times higher than previously reported filler-free polymeric hydrogels. Theoretical calculation demonstrated that the ion exchange between PEDOT:PSS and the metal halides played an important role to promote phase separation in the hydrogels, which thus leads to ultrahigh electrical conductivity. The high electrical conductivity resulted in multifunctional hydrogels with high performance in thermoelectrics, electromagnetic shielding, Joule heating, and sensing. Such flexible and stretchable hydrogels with ultrahigh electrical conductivity and stability upon various deformations are promising for soft bioelectronics devices and wearable electronics.

17.
Biochem Biophys Res Commun ; 660: 35-42, 2023 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-37060829

RESUMEN

The cardioprotective mechanisms of bradykinin-(1-9) in myocardial infarction were unclear. We investigated the effect of bradykinin-(1-9) on cardiac function, fibrosis, and autophagy induced by myocardial infarction and identified the mechanisms involved. To investigate the cardioprotective effect of bradykinin-(1-9), various doses of bradykinin-(1-9), its B2 receptor blocker HOE140, or their combination were administered to rats via subcutaneous osmotic minipump implantation before myocardial infarction. After 2 days, myocardial infarction was induced by ligation of the left anterior descending coronary artery. After 2 weeks, echocardiographic measurements and euthanasia were performed. Bradykinin-(1-9) treatment attenuated left ventricular dysfunction, fibrosis, and autophagy in rats with myocardial infarction, which was partially reversed by HOE140 administration. Moreover, the downregulatory effect of bradykinin-(1-9) on autophagy was partially reversed by combination with the PI3K inhibitor LY294002. Thus, bradykinin-(1-9) inhibits myocardial infarction-induced cardiomyocyte autophagy by upregulating the PI3K/Akt pathway.


Asunto(s)
Infarto del Miocardio , Proteínas Proto-Oncogénicas c-akt , Ratas , Animales , Proteínas Proto-Oncogénicas c-akt/metabolismo , Bradiquinina/farmacología , Bradiquinina/metabolismo , Fosfatidilinositol 3-Quinasas , Infarto del Miocardio/metabolismo , Autofagia , Fibrosis
18.
J Magn Reson Imaging ; 58(5): 1533-1541, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-36912379

RESUMEN

BACKGROUND: Anthracyclines are known to be associated with chemotherapy-induced cardiotoxicity. Limited data focus on dynamic myocardial injury during the course of chemotherapy in patients with breast cancer. PURPOSE: To investigate the variation of tissue characterization and myocardial deformation derived by cardiac MRI during anthracycline chemotherapy. STUDY TYPE: Prospective. POPULATION: Fifty-eight female breast cancer patients (mean age: 52.82 ± 2.61 years) were enrolled. FIELD STRENGTH/SEQUENCE: A 3.0-T, cardiac MRI including cine balanced steady-state free precession, a modified Looker-Locker inversion recovery (MOLLI), and a fast spin echo (FSE) T2-weighted sequences were performed. ASSESSMENT: Cardiac MRI was performed baseline and after two, four, and six cycles of chemotherapy. Assessment of global longitudinal strain (GLS), global circumstance strain (GCS), global radial strain (GRS), and strain rate (GLS-s, GCS-s, GRS-s) and T1, T2 and T2* were accomplished by CVI42. The anthracycline dose and risk factors were also collected before each cardiac MRI. STATISTICAL TESTS: Analysis of variance (ANOVA) for repeated measures was used to compare the changes in LVEF cardiac function, strain and T1/T2/T2* parameters over time. Pearson correlation analyses were performed to estimate the potential associations between differences in myocardial characteristics (∆) and the chemotherapy cycle. A P value <0.05 was considered statistically significant. RESULTS: LVEF was not significantly different from pretreatment MRI regarding each cycle of chemotherapy (P = 0.54). Compared with baseline, patients had significantly lower GLS (-15.85% ± 0.83%, -14.50% ± 0.88%, -12.34% ± 1.01% vs. -18.82% ± 0.92%) and GLS-s (-0.71% ± 0.07%, -0.65% ± 0.05%, -0.64% ± 0.04% vs. -0.95 ± 0.06%) and increased T2 values (57.21 ± 4.27 msec, 58.60 ± 3.93 msec, 58.10 ± 3.17 msec vs. 43.88 ± 3.28 msec) at two, four and six cycles of chemotherapy treatment. ∆GLS and ∆GLS-s were significantly associated with the chemotherapy cycle (correlation coefficients for GLS = 0.75, GLS-s = 0.75). DATA CONCLUSION: Cardiac MRI can precisely detect the dynamic changes of anthracycline-induced subclinical myocardial injury that is represented as a gradually decrease in GLS and GLS-s. These parameters may provide new insight for monitoring risk and therapy in patients with breast cancer. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Neoplasias de la Mama , Lesiones Cardíacas , Humanos , Femenino , Persona de Mediana Edad , Antraciclinas/efectos adversos , Estudios Prospectivos , Cardiotoxicidad/diagnóstico por imagen , Cardiotoxicidad/tratamiento farmacológico , Cardiotoxicidad/etiología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Imagen por Resonancia Magnética/efectos adversos , Función Ventricular Izquierda , Volumen Sistólico
19.
Nanoscale ; 15(14): 6844-6852, 2023 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-36961230

RESUMEN

Molybdenum selenide (MoSe2) has recently attracted particular attention due to its room-temperature ferromagnetism (RTFM) and related spintronic applications. However, not only does the FM mechanism of MoSe2 remain controversial, but also the synthesis of MoSe2 thin films with robust RTFM is still an unmet challenge. Here it is shown that using polymer-assisted deposition under appropriate growth conditions, large-scale (4 cm × 4 cm) synthesis of MoSe2 thin films with robust RTFM and a smooth surface (roughness average ∼0.22 nm) is possible. A new record-high saturation magnetization (6.69 emu g-1) is achieved in the prepared MoSe2 thin films, about 5 times the previously reported record (1.39 emu g-1) obtained in 2H-MoSe2 nanoflakes. Meanwhile, the coercivity of the MoSe2 films can be tuned down to a new record-low value (5.0 Oe), one-tenth of the previously reported record. Notably, detailed analysis combining the experimental findings and calculation results shows that the robust RTFM mainly comes from the Ruderman-Kittel-Kasuya-Yoshida (RKKY) interaction between the magnetic moments induced by abundant Mo vacancies (VMos) in the MoSe2 films. Our results give insights into the large-scale production and robust RTFM of MoSe2 thin films and may provide a platform for designing and fabricating spintronic materials and devices based on transition-metal dichalcogenides.

20.
Mil Med Res ; 10(1): 16, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36978167

RESUMEN

Biomimetic materials have emerged as attractive and competitive alternatives for tissue engineering (TE) and regenerative medicine. In contrast to conventional biomaterials or synthetic materials, biomimetic scaffolds based on natural biomaterial can offer cells a broad spectrum of biochemical and biophysical cues that mimic the in vivo extracellular matrix (ECM). Additionally, such materials have mechanical adaptability, microstructure interconnectivity, and inherent bioactivity, making them ideal for the design of living implants for specific applications in TE and regenerative medicine. This paper provides an overview for recent progress of biomimetic natural biomaterials (BNBMs), including advances in their preparation, functionality, potential applications and future challenges. We highlight recent advances in the fabrication of BNBMs and outline general strategies for functionalizing and tailoring the BNBMs with various biological and physicochemical characteristics of native ECM. Moreover, we offer an overview of recent key advances in the functionalization and applications of versatile BNBMs for TE applications. Finally, we conclude by offering our perspective on open challenges and future developments in this rapidly-evolving field.


Asunto(s)
Materiales Biocompatibles , Materiales Biomiméticos , Humanos , Materiales Biocompatibles/farmacología , Materiales Biocompatibles/uso terapéutico , Materiales Biocompatibles/química , Ingeniería de Tejidos , Medicina Regenerativa , Biomimética , Materiales Biomiméticos/farmacología , Materiales Biomiméticos/uso terapéutico , Materiales Biomiméticos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...