Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Am J Gastroenterol ; 112(6): 913-923, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28323272

RESUMEN

OBJECTIVES: The objective of this study was to determine whether constipation-predominant irritable bowel syndrome (IBS-C) is associated with changes in intestinal barrier and secretory function. METHODS: A total of 19 IBS-C patients and 18 healthy volunteers (all females) underwent saccharide excretion assay (0.1 g 13C mannitol and 1 g lactulose), measurements of duodenal and colonic mucosal barrier (transmucosal resistance (TMR), macromolecular and Escherichia coli Bio-Particle translocation), mucosal secretion (basal and acetylcholine (Ach)-evoked short-circuit current (Isc)), in vivo duodenal mucosal impedance, circulating endotoxins, and colonic tight junction gene expression. RESULTS: There were no differences in the in vivo measurements of barrier function between IBS-C patients and healthy controls: cumulative excretion of 13C mannitol (0-2 h mean (s.e.m.); IBS-C: 12.1 (0.9) mg vs. healthy: 13.2 (0.8) mg) and lactulose (8-24 h; IBS-C: 0.9 (0.5) mg vs. healthy: 0.5 (0.2) mg); duodenal impedance IBS-C: 729 (65) Ω vs. healthy: 706 (43) Ω; plasma mean endotoxin activity level IBS-C: 0.36 (0.03) vs. healthy: 0.35 (0.02); and in colonic mRNA expression of occludin, zonula occludens (ZO) 1-3, and claudins 1-12 and 14-19. The ex vivo findings were consistent, with no group differences: duodenal TMR (IBS-C: 28.2 (1.9) Ω cm2 vs. healthy: 29.8 (1.9) Ω cm2) and colonic TMR (IBS-C: 19.1 (1.1) Ω cm2 vs. healthy: 17.6 (1.7) Ω cm2); fluorescein isothiocyanate (FITC)-dextran (4 kDa) and E. coli Bio-Particle flux. Colonic basal Isc was similar, but duodenal basal Isc was lower in IBS-C (43.5 (4.5) µA cm-2) vs. healthy (56.9 (4.9) µA cm-2), P=0.05. Ach-evoked ΔIsc was similar. CONCLUSIONS: Females with IBS-C have normal colonic barrier and secretory function. Basal duodenal secretion is decreased in IBS-C.


Asunto(s)
Colon/fisiopatología , Duodeno/fisiopatología , Mucosa Intestinal/fisiopatología , Síndrome del Colon Irritable/fisiopatología , Lactulosa/metabolismo , Manitol/metabolismo , ARN Mensajero/metabolismo , Acetilcolina/farmacología , Adulto , Estudios de Casos y Controles , Agonistas Colinérgicos/farmacología , Claudinas/genética , Colon/efectos de los fármacos , Colon/patología , Estreñimiento/etiología , Duodeno/efectos de los fármacos , Duodeno/patología , Impedancia Eléctrica , Endotoxinas/sangre , Femenino , Expresión Génica , Humanos , Mucosa Intestinal/efectos de los fármacos , Mucosa Intestinal/patología , Síndrome del Colon Irritable/complicaciones , Síndrome del Colon Irritable/genética , Persona de Mediana Edad , Ocludina/genética , Permeabilidad , Uniones Estrechas/genética , Proteínas de la Zonula Occludens/genética
2.
Clin Lab Med ; 33(1): 55-73, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23331729

RESUMEN

This article proposes analytic performance goals for five quality indicators: precision, trueness, linearity, detection limits, and consistency across instruments and time. We defined our goals using methods linked to clinical practice data. Goals for desirable precision and trueness are based on biological variation. Linearity goals are related to total error recommendations. Detection limit goals are derived from 0.1 percentile of patient values. Goals for consistency are derived from the variability of distributions of patient test values. Data were collected and evaluated for each of these quality indicators for 46 chemistry tests measured on the Roche cobas 8000 analyzer.


Asunto(s)
Pruebas de Química Clínica/instrumentación , Pruebas de Química Clínica/normas , Laboratorios/normas , Ciencia del Laboratorio Clínico/instrumentación , Ciencia del Laboratorio Clínico/normas , Garantía de la Calidad de Atención de Salud/métodos , Humanos , Límite de Detección , Modelos Lineales , Modelos Teóricos , Control de Calidad
3.
Clin Chim Acta ; 413(11-12): 1015-7, 2012 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-22353668

RESUMEN

INTRODUCTION: Rheumatoid arthritis (RA) is an inflammatory autoimmune disease characterized by chronic joint inflammation and extra-articular manifestations, eventually leading to permanent disability without early therapeutic interventions. METHODS: The analytical and clinical performance of an electrochemiluminescent immunoassay (ECLIA) (Roche Diagnostics, Indianapolis, IN) were determined for cyclic citrullinated peptide antibodies (anti-CCP) in the diagnostic assessment of rheumatoid arthritis compared to a plate-based anti-CCP enzyme immunoassay (EIA) (Inova Diagnostics, Inc.). RESULTS: Imprecision studies on the automated Roche ECLIA demonstrated intra-assay CV's of <3% and inter-assay CV's of <7%. The Inova EIA had intra-assay CV's of <15% and inter-assay CV's of <12%. The limit of quantitation of both assays was acceptable, and both assays showed similar linearity within the manufacturer's defined reportable ranges. Overall, analytical concordance was 62%, with 95.2% positive and 53.2% negative concordance. The clinical specificity in a normal population (n=91) was 98.9% and 100% for Roche ECLIA and Inova EIA, respectively. The clinical specificity in a connective tissue disease population (n=98) was 91.9% (95%CI, 86.0 to 96.5%) and 88.8% (95% CI, 81.0 to 93.6%) for Roche ECLIA and Inova EIA, respectively. CONCLUSION: The Roche ECLIA demonstrated similar analytical performance, although with improved intra-assay precision, in comparison to the Inova EIA. The two methods also demonstrated similar clinical sensitivity and specificity. The Roche automated immunoassay is a viable alternative to the plate-based EIAs with the advantage of being performed on an automated platform.


Asunto(s)
Artritis Reumatoide/diagnóstico , Inmunoensayo/métodos , Péptidos Cíclicos/inmunología , Factor Reumatoide/análisis , Automatización de Laboratorios/métodos , Enfermedades del Tejido Conjuntivo/diagnóstico , Femenino , Humanos , Técnicas para Inmunoenzimas/métodos , Mediciones Luminiscentes/métodos , Masculino , Valores de Referencia , Factor Reumatoide/inmunología , Sensibilidad y Especificidad
4.
Clin Chem ; 55(10): 1869-75, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19679633

RESUMEN

BACKGROUND: Natriuretic peptide concentrations in adults require age- and sex-specific reference intervals for optimal interpretation. Females have higher natriuretic peptide concentrations, and hypotheses suggest that estrogen may be responsible. This study sought to determine the influence of hormone modulation on N-terminal probrain natriuretic peptide (NT-proBNP) by using a pediatric cohort. Children/adolescents typically have rapid hormone changes during puberty, making them an ideal group to study. METHODS: We selected 759 specimens (303 male, 456 female; ages 2 months to 18 years, mean 13 years) obtained from the Mayo Clinic Pediatric Residual Specimen Bank. We measured NT-proBNP, sex hormone-binding globulin (SHBG), estradiol, and testosterone by immunoassays or LC-MS/MS and calculated free testosterone. We performed univariate and multivariate analyses to investigate the significance of NT-proBNP with each hormone. RESULTS: Reference values demonstrated a sex difference and sequential age differences in females. Univariate modeling of the hormones with NT-proBNP revealed an independent inverse association of NT-proBNP with testosterone, a direct association with SHBG, and no significant association with estradiol. Multivariate modeling confirmed a strong association of testosterone and SHBG with NT-proBNP. Correlation of hormones with NT-proBNP retained greater significance than either age or sex. CONCLUSIONS: In pediatric patients, NT-proBNP is independently associated with both testosterone and SHBG hormone concentrations. Measurements of testosterone are inversely associated with NT-proBNP, and estrogens are marginally associated with NT-proBNP in males but not females, suggesting that androgens and not estrogens modulate sex differences notable in natriuretic peptides. Children and adolescents may require an objective assessment of hormones if optimal interpretation of natriuretic peptide concentrations is desired or the concentrations are confounded. .


Asunto(s)
Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Testosterona/sangre , Adolescente , Factores de Edad , Análisis de Varianza , Niño , Preescolar , Estudios de Cohortes , Estradiol/sangre , Femenino , Humanos , Lactante , Masculino , Valores de Referencia , Factores Sexuales , Globulina de Unión a Hormona Sexual/análisis
SELECCIÓN DE REFERENCIAS