Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Diabetes Sci Technol ; : 19322968241242803, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613227

RESUMEN

BACKGROUND: CamAPS HX fully closed-loop (FCL) system, with no user input required at mealtimes, has been shown to be safe and effective in adults with type 1 and type 2 diabetes. We assessed whether time spent in hypoglycemia and hyperglycemia during FCL insulin delivery in adults varied by type of diabetes over the 24-hour period. METHODS: We retrospectively analyzed eight weeks of data from 52 participants (adults with type 1 diabetes and adults with insulin-treated type 2 diabetes) recruited to two single-center randomized controlled studies using FCL insulin delivery during unrestricted-living conditions. Key outcomes were time spent in hypoglycemia <70 mg/dL and marked hyperglycemia >300 mg/dL by type of diabetes. RESULTS: The median percentage of time spent in hypoglycemia <70 mg/dL over the 24-hour period was lower for those with type 2 diabetes than for those with type 1 diabetes (median [interquartile range (IQR)] 0.43% [0.20-0.77] vs 0.86%, [0.54-1.46]; mean difference 0.46 percentage points [95% CI 0.23-0.70]; P < .001). Median percentage time in marked hyperglycemia >300 mg/dL was lower for those with type 2 diabetes than for those with type 1 diabetes (median [IQR] 1.8% [0.6-3.5] vs 9.3% [6.9-11.8]; mean difference 7.8 percentage points [95% CI 5.5-10.0]; P < .001). CONCLUSIONS: Using the FCL system, hypoglycemia and marked hyperglycemia exposure were lower in type 2 diabetes than in type 1 diabetes.

4.
Nat Med ; 29(1): 203-208, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36631592

RESUMEN

In adults with type 2 diabetes, the benefits of fully closed-loop insulin delivery, which does not require meal bolusing, are unclear. In an open-label, single-center, randomized crossover study, 26 adults with type 2 diabetes (7 women and 19 men; (mean ± s.d.) age, 59 ± 11 years; baseline glycated hemoglobin (HbA1c), 75 ± 15 mmol mol-1 (9.0% ± 1.4%)) underwent two 8-week periods to compare the CamAPS HX fully closed-loop app with standard insulin therapy and a masked glucose sensor (control) in random order, with a 2-week to 4-week washout between periods. The primary endpoint was proportion of time in target glucose range (3.9-10.0 mmol l-1). Analysis was by intention to treat. Thirty participants were recruited between 16 December 2020 and 24 November 2021, of whom 28 were randomized to two groups (14 to closed-loop therapy first and 14 to control therapy first). Proportion of time in target glucose range (mean ± s.d.) was 66.3% ± 14.9% with closed-loop therapy versus 32.3% ± 24.7% with control therapy (mean difference, 35.3 percentage points; 95% confidence interval (CI), 28.0-42.6 percentage points; P < 0.001). Time > 10.0 mmol l-1 was 33.2% ± 14.8% with closed-loop therapy versus 67.0% ± 25.2% with control therapy (mean difference, -35.2 percentage points; 95% CI, -42.8 to -27.5 percentage points; P < 0.001). Mean glucose was lower during the closed-loop therapy period than during the control therapy period (9.2 ± 1.2 mmol l-1 versus 12.6 ± 3.0 mmol l-1, respectively; mean difference, -3.6 mmol l-1; 95% CI, -4.6 to -2.5 mmol l-1; P < 0.001). HbA1c was lower following closed-loop therapy (57 ± 9 mmol mol-1 (7.3% ± 0.8%)) than following control therapy (72 ± 13 mmol mol-1 (8.7% ± 1.2%); mean difference, -15 mmol mol-1; 95% CI, -11 to -20 mmol l-1 (mean difference, -1.4%; 95% CI, -1.0 to -1.8%); P < 0.001). Time < 3.9 mmol l-1 was similar between treatments (a median of 0.44% (interquartile range, 0.19-0.81%) during the closed-loop therapy period versus a median of 0.08% (interquartile range, 0.00-1.05%) during the control therapy period; P = 0.43). No severe hypoglycemia events occurred in either period. One treatment-related serious adverse event occurred during the closed-loop therapy period. Fully closed-loop insulin delivery improved glucose control without increasing hypoglycemia compared with standard insulin therapy and may represent a safe and efficacious method to improve outcomes in adults with type 2 diabetes. This study is registered with ClinicalTrials.gov (NCT04701424).


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglucemia , Masculino , Humanos , Adulto , Femenino , Persona de Mediana Edad , Anciano , Insulina , Glucemia , Estudios Cruzados , Hipoglucemiantes , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Resultado del Tratamiento , Sistemas de Infusión de Insulina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA