Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Space Sci Rev ; 214(1)2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-30713357

RESUMEN

OSIRIS-REx will return pristine samples of carbonaceous asteroid Bennu. This article describes how pristine was defined based on expectations of Bennu and on a realistic understanding of what is achievable with a constrained schedule and budget, and how that definition flowed to requirements and implementation. To return a pristine sample, the OSIRIS-REx spacecraft sampling hardware was maintained at level 100 A/2 and <180 ng/cm2 of amino acids and hydrazine on the sampler head through precision cleaning, control of materials, and vigilance. Contamination is further characterized via witness material exposed to the spacecraft assembly and testing environment as well as in space. This characterization provided knowledge of the expected background and will be used in conjunction with archived spacecraft components for comparison with the samples when they are delivered to Earth for analysis. Most of all, the cleanliness of the OSIRIS-REx spacecraft was achieved through communication among scientists, engineers, managers, and technicians.

2.
Ophthalmology ; 105(5): 906-12, 1998 May.
Artículo en Inglés | MEDLINE | ID: mdl-9593396

RESUMEN

OBJECTIVE: This study aimed to correlate histologic characteristics with high-frequency ultrasound backscatter spectra in malignant melanomas of the iris. DESIGN: The study design was a cohort (case series) study of patients diagnosed with iris melanoma in the authors' clinic. PARTICIPANTS: Sixteen patients with iris melanoma participated. INTERVENTION: The patients were scanned with a 50-MHz ultrasound unit equipped for digitization of raw echo data. Spectral parameter images representing the spatial distribution of size and concentration of tissue inhomogeneities were produced. MAIN OUTCOME MEASURES: The variation of spectral properties within and between tumors was determined. In the two tumors in this series for which histologic material was available, the authors compared scatterer concentration and size with histology and mathematically modeled the effect of melanocyte distribution on spectra. RESULTS: Ultrasound scattering characteristics differed considerably among tumors. Where histology was available, acoustic parameters correlated with the size and number of melanocytes present. CONCLUSIONS: Iris melanomas exhibited a wide range in acoustic backscatter properties. Whereas characteristics such as vascularity and necrosis might contribute to this, in the two cases examined here, backscatter characteristics could be largely accounted for by melanocyte distribution. A better understanding of the relationship of histology to noninvasive ultrasound data will enhance the diagnostic utility of this technique.


Asunto(s)
Neoplasias del Iris/diagnóstico por imagen , Neoplasias del Iris/patología , Melanoma/diagnóstico por imagen , Melanoma/patología , Adulto , Estudios de Cohortes , Femenino , Humanos , Neoplasias del Iris/cirugía , Melanoma/cirugía , Persona de Mediana Edad , Ultrasonografía
3.
Ophthalmology ; 105(2): 300-6, 1998 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9479291

RESUMEN

OBJECTIVE: The aim of this report is to describe the technology of three-dimensional (3-D) ultrasonic imaging and its impact on improved diagnosis and monitoring of ocular disease. DESIGN: The authors reviewed techniques for acquiring and displaying 3-D ultrasound data of the eye. PARTICIPANTS: The authors applied these techniques to representative individual cases, including a choroidal hemorrhage, a ciliary body melanoma, a ciliary body detachment, a displaced posterior chamber intraocular lens, and topographic analysis of a normal cornea. INTERVENTION: A computer-controlled motion system was used to perform very high-frequency (VHF) (50-MHz) and conventional (10-MHz) digital 3-D ultrasound data collection. The scanning system allowed digitization of ultrasound data from a series of parallel planes. The 3-D data could be manipulated interactively to obtain two-dimensional images in any plane through the scan volume. The 3-D images were constructed by volume rendering and could be positioned for viewing from a variety of perspectives. The 3-D ultrasound parameter images representing acoustic scatterer properties were generated by spectrum analysis of digitized echo data. Color maps representing the contour and thickness of the epithelium and stroma of the central corneal were generated by digital signal processing of 3-D echo data. RESULTS: Quantitative volume measurement and biometric techniques enhanced the diagnostic and treatment planning information content in 3-D ultrasound images. The location and extent of hemorrhage and clots within the suprachoroidal space were shown with solid modeling. Volume changes in ciliary body melanoma over time were documented and 3-D ultrasound parameter image changes associated with radiation therapy observed. In ciliary body detachment, the extent of the detachment was shown. Solid modeling of a posterior chamber intraocular lens showed misplacement of the haptic in relation to the lens capsule remnants. Keratopachymetric maps showed the range and variance of thickness and local radius of curvature measurements in the cornea. CONCLUSIONS: Quantitative volume measurement and biometric tools combined with segmentation of 3-D ultrasound images improve diagnostic and treatment planning informational content of 3-D ultrasound images through improved localization of tissue structures.


Asunto(s)
Oftalmopatías/diagnóstico por imagen , Ultrasonografía/métodos , Hemorragia de la Coroides/diagnóstico por imagen , Cuerpo Ciliar/diagnóstico por imagen , Topografía de la Córnea/métodos , Migración de Cuerpo Extraño/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Lentes Intraoculares , Melanoma/diagnóstico por imagen , Enfermedades de la Úvea/diagnóstico por imagen , Neoplasias de la Úvea/diagnóstico por imagen
4.
Radiol Clin North Am ; 36(6): 1073-82, x, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9884689

RESUMEN

New ultrasound technologies, including three-dimensional imaging, tissue characterization, and very high frequency (50 MHz) ultrasound, have become available recently. We demonstrate how these technologies can be used alone and together to improve the use of ultrasound for diagnosis of ocular pathology.


Asunto(s)
Oftalmopatías/diagnóstico por imagen , Ojo/diagnóstico por imagen , Humanos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Ciencia del Laboratorio Clínico/métodos , Ultrasonido/clasificación , Ultrasonografía/instrumentación , Ultrasonografía/métodos
5.
J Trop Med Hyg ; 94(5): 333-7, 1991 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1942212

RESUMEN

The present study was conducted on 14 patients with established fascioliasis. The effect of infection on the haematological and biochemical parameters was determined and the liver and gall bladder were studied by ultrasonography. Bithionol was given in the dose of 30 mg kg-1 body weight every other day for 5 doses. The therapeutic efficacy was assessed by egg and eosinophilic counts and quantitative estimation of antibody titres by indirect haemagglutination test. Results revealed that fascioliasis caused normocytic hypochromic anaemia and eosinophilia. Serum bilirubin, ALT and AST were within normal range. Ultrasonography showed a normal echogenic pattern of the liver and gall bladder. One case showed thickness of the gall bladder wall which was tender under the transiducer. Fasciola eggs disappeared completely after the 5th dose giving a cure rate of 100%. Antibody titres reached a normal level at the end of the 3rd month post treatment. Bithionol proved to be a potent fasciolicidal drug with minimal side-effects.


Asunto(s)
Bitionol/uso terapéutico , Fascioliasis/sangre , Vesícula Biliar/diagnóstico por imagen , Hígado/diagnóstico por imagen , Adolescente , Adulto , Anemia Hipocrómica/etiología , Bitionol/efectos adversos , Egipto , Eosinofilia/etiología , Índices de Eritrocitos , Fascioliasis/diagnóstico por imagen , Fascioliasis/tratamiento farmacológico , Femenino , Hematócrito , Hemoglobinas/análisis , Humanos , Masculino , Persona de Mediana Edad , Ultrasonografía
7.
Pediatr Radiol ; 13(4): 227-8, 1983.
Artículo en Inglés | MEDLINE | ID: mdl-6888995

RESUMEN

A case of unsuspected aspiration of an oropharyngeal airway causing dysphagia is described. Visualization of this airway on plain film would be facilitated if radio-opaque material were included at manufacture.


Asunto(s)
Cuerpos Extraños/diagnóstico por imagen , Hipofaringe/diagnóstico por imagen , Adolescente , Trastornos de Deglución/etiología , Humanos , Inhalación , Intubación/instrumentación , Masculino , Radiografía , Heridas y Lesiones/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...