Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Sci Adv ; 10(19): eadl1230, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38718109

RESUMEN

The spinal cord is crucial for transmitting motor and sensory information between the brain and peripheral systems. Spinal cord injuries can lead to severe consequences, including paralysis and autonomic dysfunction. We introduce thin-film, flexible electronics for circumferential interfacing with the spinal cord. This method enables simultaneous recording and stimulation of dorsal, lateral, and ventral tracts with a single device. Our findings include successful motor and sensory signal capture and elicitation in anesthetized rats, a proof-of-concept closed-loop system for bridging complete spinal cord injuries, and device safety verification in freely moving rodents. Moreover, we demonstrate potential for human application through a cadaver model. This method sees a clear route to the clinic by using materials and surgical practices that mitigate risk during implantation and preserve cord integrity.


Asunto(s)
Traumatismos de la Médula Espinal , Médula Espinal , Animales , Médula Espinal/fisiología , Ratas , Traumatismos de la Médula Espinal/terapia , Traumatismos de la Médula Espinal/fisiopatología , Humanos , Estimulación Eléctrica/métodos , Electrodos Implantados
2.
Nat Mater ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671159

RESUMEN

Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces.

3.
J Neurosurg Case Lessons ; 7(17)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38648674

RESUMEN

BACKGROUND: Peripheral neurolymphomatosis (NL) is an often-misdiagnosed condition characterized by lymphomatous infiltration within the peripheral nerves. Its rarity and complexity frequently result in delayed diagnosis and suboptimal patient outcomes. This study aims to elucidate the role of the paraneurium (circumneurium) in NL, emphasizing its diagnostic and therapeutic significance. OBSERVATIONS: A 72-year-old man presented with lesions on his right lower eyelid. Initial diagnostics were inconclusive until an excisional biopsy confirmed extranodal marginal zone lymphoma. Following a complete metabolic response to rituximab treatment, the patient relapsed 14 months later with progressive lymphoma and bilateral sciatic nerve involvement, as confirmed by positron emission tomography-computed tomography and magnetic resonance imaging. LESSONS: This paper underscores the critical role of the paraneurium in NL, enhancing understanding of its pathophysiology. Integrating advanced imaging techniques have proved essential in accurately identifying neurolymphomatous involvement within the paraneurium. This study paves the way for more effective management strategies in NL and similar conditions, focusing on improving patient care and outcomes.

4.
Ecol Evol ; 14(2): e10872, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38333101

RESUMEN

Animal size, a trait sensitive to spatial and temporal variables, is a key element in ecological and evolutionary dynamics. In the context of climate change, there is evidence that some bat species are increasing their body size via phenotypic responses to higher temperatures at maternity roosts. To test the generality of this response, we conducted a >20-year study examining body size changes in 15 bat species in Italy, analysing data from 4393 individual bats captured since 1995. In addition to examining the temporal effect, we considered the potential influence of sexual dimorphism and, where relevant, included latitude and altitude as potential drivers of body size change. Contrary to initial predictions of a widespread increase in size, our findings challenge this assumption, revealing a nuanced interplay of factors contributing to the complexity of bat body size dynamics. Specifically, only three species (Myotis daubentonii, Nyctalus leisleri, and Pipistrellus pygmaeus) out of the 15 exhibited a discernible increase in body size over the studied period, prompting a reassessment of bats as reliable indicators of climate change based on alterations in body size. Our investigation into influencing factors highlighted the significance of temperature-related variables, with latitude and altitude emerging as crucial drivers. In some cases, this mirrored patterns consistent with Bergmann's rule, revealing larger bats recorded at progressively higher latitudes (Plecotus auritus, Myotis mystacinus, and Miniopterus schreibersii) or altitudes (Pipistrellus kuhlii). We also observed a clear sexual dimorphism effect in most species, with females consistently larger than males. The observed increase in size over time in three species suggests the occurrence of phenotypic plasticity, raising questions about potential long-term selective pressures on larger individuals. The unresolved question of whether temperature-related changes in body size reflect microevolutionary processes or phenotypic plastic responses adds further complexity to our understanding of body size patterns in bats over time and space.

5.
Biomaterials ; 303: 122393, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37977006

RESUMEN

Spinal cord injuries have devastating consequences for humans, as mammalian neurons of the central nervous system (CNS) cannot regenerate. In the peripheral nervous system (PNS), however, neurons may regenerate to restore lost function following injury. While mammalian CNS tissue softens after injury, how PNS tissue mechanics changes in response to mechanical trauma is currently poorly understood. Here we characterised mechanical rat nerve tissue properties before and after in vivo crush and transection injuries using atomic force microscopy-based indentation measurements. Unlike CNS tissue, PNS tissue significantly stiffened after both types of tissue damage. This nerve tissue stiffening strongly correlated with an increase in collagen I levels. Schwann cells, which crucially support PNS regeneration, became more motile and proliferative on stiffer substrates in vitro, suggesting that changes in tissue stiffness may play a key role in facilitating or impeding nervous system regeneration.


Asunto(s)
Tejido Nervioso , Traumatismos de la Médula Espinal , Humanos , Ratas , Animales , Sistema Nervioso Central , Células de Schwann/fisiología , Neuronas , Regeneración Nerviosa/fisiología , Axones/fisiología , Mamíferos
6.
Sci Adv ; 9(12): eadd8162, 2023 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-36947608

RESUMEN

The development of neural interfaces with superior biocompatibility and improved tissue integration is vital for treating and restoring neurological functions in the nervous system. A critical factor is to increase the resolution for mapping neuronal inputs onto implants. For this purpose, we have developed a new category of neural interface comprising induced pluripotent stem cell (iPSC)-derived myocytes as biological targets for peripheral nerve inputs that are grafted onto a flexible electrode arrays. We show long-term survival and functional integration of a biohybrid device carrying human iPSC-derived cells with the forearm nerve bundle of freely moving rats, following 4 weeks of implantation. By improving the tissue-electronics interface with an intermediate cell layer, we have demonstrated enhanced resolution and electrical recording in vivo as a first step toward restorative therapies using regenerative bioelectronics.


Asunto(s)
Neuronas , Nervios Periféricos , Ratas , Humanos , Animales , Electrodos , Regeneración Nerviosa
7.
Neurosurgery ; 92(2): 251-257, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36542350

RESUMEN

BACKGROUND: In the first part of this report, the European Association of Neurosurgical Societies' section of peripheral nerve surgery presented a systematic literature review and consensus statements on anatomy, classification, and diagnosis of thoracic outlet syndrome (TOS) along with a subclassification system of neurogenic TOS (nTOS). Because of the lack of level 1 evidence, especially regarding the management of nTOS, we now add a consensus statement on nTOS treatment among experienced neurosurgeons. OBJECTIVE: To document consensus and controversy on nTOS management, with emphasis on timing and types of surgical and nonsurgical nTOS treatment, and to support patient counseling and clinical decision-making within the neurosurgical community. METHODS: The literature available on PubMed/MEDLINE was systematically searched on February 13, 2021, and yielded 2853 results. Screening and classification of abstracts was performed. In an online meeting that was held on December 16, 2021, 14 recommendations on nTOS management were developed and refined in a group process according to the Delphi consensus method. RESULTS: Five RCTs reported on management strategies in nTOS. Three prospective observational studies present outcomes after therapeutic interventions. Fourteen statements on nonsurgical nTOS treatment, timing, and type of surgical therapy were developed. Within our expert group, the agreement rate was high with a mean of 97.8% (± 0.04) for each statement, ranging between 86.7% and 100%. CONCLUSION: Our work may help to improve clinical decision-making among the neurosurgical community and may guide nonspecialized or inexperienced neurosurgeons with initial patient management before patient referral to a specialized center.


Asunto(s)
Síndrome del Desfiladero Torácico , Humanos , Síndrome del Desfiladero Torácico/diagnóstico , Síndrome del Desfiladero Torácico/cirugía , Resultado del Tratamiento , Estudios Prospectivos , Procedimientos Neuroquirúrgicos/efectos adversos , Descompresión Quirúrgica/efectos adversos , Nervios Periféricos/cirugía , Estudios Observacionales como Asunto
8.
Adv Mater ; 35(8): e2207847, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36458737

RESUMEN

Bioelectronics hold the key for understanding and treating disease. However, achieving stable, long-term interfaces between electronics and the body remains a challenge. Implantation of a bioelectronic device typically initiates a foreign body response, which can limit long-term recording and stimulation efficacy. Techniques from regenerative medicine have shown a high propensity for promoting integration of implants with surrounding tissue, but these implants lack the capabilities for the sophisticated recording and actuation afforded by electronics. Combining these two fields can achieve the best of both worlds. Here, the construction of a hybrid implant system for creating long-term interfaces with tissue is shown. Implants are created by combining a microelectrode array with a bioresorbable and remodellable gel. These implants are shown to produce a minimal foreign body response when placed into musculature, allowing one to record long-term electromyographic signals with high spatial resolution. This device platform drives the possibility for a new generation of implantable electronics for long-term interfacing.


Asunto(s)
Electrónica , Cuerpos Extraños , Humanos , Prótesis e Implantes , Microelectrodos , Medicina Regenerativa
9.
Neurol Res ; 45(1): 81-85, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36208460

RESUMEN

AIM: Peripheral nerve tumors (PNT) are rare lesions. To date, no systematic multicenter studies on epidemiology, clinical symptoms, treatment strategies and outcomes, genetic and histopathologic features, as well as imaging characteristics of PNT were published. The main goal of our PNT Registry is the systematic multicenter investigation to improve our understanding of PNT and to assist future interventional studies in establishing hypotheses, determining potential endpoints, and assessing treatment efficacy. METHODS: Aims of the PNT registry were set at the 2015 Meeting of the Section of Peripheral Nerve Surgery of the German Society of Neurosurgery. A study protocol was developed by specialists in PNT care. A minimal data set on clinical status, treatment types and outcomes is reported by each participating center at initial contact with the patient and after 1 year, 2 years, and 5 years. Since the study is coordinated by the Charité Berlin, the PNR Registry was approved by the Charité ethics committee (EA4/058/17) and registered with the German Trials Registry (www.drks.de). On a national level, patient inclusion began in June 2016. The registry was rolled out across Europe at the 2019 meeting of the European Association of Neurosurgery in Dublin. RESULTS: Patient recruitment has been initiated at 10 centers throughout Europe and 14 additional centers are currently applying for local ethics approval. CONCLUSION: To date, the PNT registry has grown into an international study group with regular scientific and clinical exchange awaiting the first results of the retrospective study arm.


Asunto(s)
Neoplasias del Sistema Nervioso Periférico , Humanos , Estudios Retrospectivos , Sistema de Registros , Europa (Continente) , Estudios de Cohortes
10.
Adv Healthc Mater ; 11(18): e2200739, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35871265

RESUMEN

Implantable electronic medical devices are used in functional mapping of the brain before surgery and to deliver neuromodulation for the treatment of neurological and neuropsychiatric disorders. Their electrode arrays are assembled by hand, and this leads to bulky form factors with limited flexibility and low electrode counts. Thin film implants, made using microfabrication techniques, are emerging as an attractive alternative, as they offer dramatically improved conformability and enable high density recording and stimulation. A major limitation of these devices, however, is that they are invisible to fluoroscopy, the most common method used to monitor the insertion of implantable electrodes. Here, the development of mechanically flexible X-ray markers using bismuth- and barium-infused elastomers is reported. Their X-ray attenuation properties in human cadavers are explored and it is shown that they are biocompatible in cell cultures. It is further shown that they do not distort magnetic resonance imaging images and their integration with thin film implants is demonstrated. This work removes a key barrier for the adoption of thin film implants in brain mapping and in neuromodulation.


Asunto(s)
Bismuto , Elastómeros , Bario , Electrodos Implantados , Humanos , Rayos X
11.
Mater Horiz ; 9(6): 1727-1734, 2022 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-35474130

RESUMEN

New fabrication approaches for mechanically flexible implants hold the key to advancing the applications of neuroengineering in fundamental neuroscience and clinic. By combining the high precision of thin film microfabrication with the versatility of additive manufacturing, we demonstrate a straight-forward approach for the prototyping of intracranial implants with electrode arrays and microfluidic channels. We show that the implant can modulate neuronal activity in the hippocampus through localized drug delivery, while simultaneously recording brain activity by its electrodes. Moreover, good implant stability and minimal tissue response are seen one-week post-implantation. Our work shows the potential of hybrid fabrication combining different manufacturing techniques in neurotechnology and paves the way for a new approach to the development of multimodal implants.


Asunto(s)
Fenómenos Electrofisiológicos , Neurociencias , Electrofisiología Cardíaca , Microtecnología , Prótesis e Implantes
12.
J Neural Eng ; 19(2)2022 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-35320780

RESUMEN

Bioelectronic stimulation of the spinal cord has demonstrated significant progress in the restoration of motor function in spinal cord injury (SCI). The proximal, uninjured spinal cord presents a viable target for the recording and generation of control signals to drive targeted stimulation. Signals have been directly recorded from the spinal cord in behaving animals and correlated with limb kinematics. Advances in flexible materials, electrode impedance and signal analysis will allow spinal cord recording (SCR) to be used in next-generation neuroprosthetics. In this review, we summarize the technological advances enabling progress in SCR and describe systematically the clinical challenges facing spinal cord bioelectronic interfaces and potential solutions, from device manufacture, surgical implantation to chronic effects of foreign body reaction and stress-strain mismatches between electrodes and neural tissue. Finally, we establish our vision of bi-directional closed-loop spinal cord bioelectronic bypass interfaces that enable the communication of disrupted sensory signals and restoration of motor function in SCI.


Asunto(s)
Traumatismos de la Médula Espinal , Médula Espinal , Animales , Fenómenos Biomecánicos , Electrodos , Médula Espinal/fisiología , Traumatismos de la Médula Espinal/terapia
13.
Proc Natl Acad Sci U S A ; 119(12): e2115857119, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35298334

RESUMEN

SignificanceImplantable electronic medical devices (IEMDs) are used for some clinical applications, representing an exciting prospect for the transformative treatment of intractable conditions such Parkinson's disease, deafness, and paralysis. The use of IEMDs is limited at the moment because, over time, a foreign body reaction (FBR) develops at the device-neural interface such that ultimately the IEMD fails and needs to be removed. Here, we show that macrophage nucleotide-binding oligomerization domain-like receptor family pyrin domain containing 3 (NLRP3) inflammasome activity drives the FBR in a nerve injury model yet integration of an NLRP3 inhibitor into the device prevents FBR while allowing full healing of damaged neural tissue to occur.


Asunto(s)
Cuerpos Extraños , Inflamasomas , Humanos , Macrófagos , Proteína con Dominio Pirina 3 de la Familia NLR , Prótesis e Implantes
14.
Oper Neurosurg (Hagerstown) ; 22(1): e48, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34982918

RESUMEN

Tumors around the cervicomedullary junction are rare and constitute 5% of spinal tumors and 1% of cranial tumors. The approach to these lesions is difficult because of the close proximity of the medulla and cervical spinal cord, lower cranial nerves, and vertebral artery (VA) as well as the complex articulation between occipital condyle, C1 and C2. Cervicomedullary junction meningiomas are commonly classified based on their origin in relation to the dentate ligament, but the relationship to the VA typically plays an important role in deciding the surgical approach. For lesions located dorsal to the dentate ligament and not involving the VA, a midline approach is typically sufficient. However, when the VA is involved a far lateral approach is preferred as it offers better access to the V4 segment. We describe a case of a 55-yr-old man who presented with accessory nerve palsy and mild upper motor neuron signs and was found to have a C1 meningioma encasing and narrowing the VA at the V3/V4 segment. Informed consent was obtained. The patient was treated with a right far lateral approach with limited condylectomy to gain access to the V4 segment. We described the steps used for safe resection of the tumor around the VA from distal to proximal. We demonstrate the relationship of the tumor to the VA and the need to completely skeletonize the VA to achieve a gross total resection. We supplement the discussion with a 3D surgical video.

15.
Oper Neurosurg (Hagerstown) ; 22(1): e49, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34982919

RESUMEN

Upper cervical schwannomas are rare lesions and together with meningiomas constitute around 5% of spinal tumors. The approach to these lesions is difficult because of the close proximity of the medulla and cervical spinal cord, lower cranial nerves, and the vertebral artery. Schwannomas in the upper cervical area typically arise from the dorsal roots and are located posterior to the dentate ligament. Nevertheless, a far lateral approach is often required for these lesions because of their lateral extent through the neural foramen and the proximity of both the V3 and V4 segments of the vertebral artery. With these lesions, an extensive condylectomy is rarely required. We present a case of a 40-yr-old woman who presented with an 8-mo history of deteriorating mobility and feeling of heaviness in the lower limbs with a further acute deterioration 1 wk before admission. She had a dissociated sensory loss and myelopathy in keeping with a partial hemicord syndrome. Imaging revealed a right-sided C2 intradural lesion extending through the C2 foramen in keeping with a C2 schwannoma. The patient was counseled on the treatment options, and informed consent for surgery was obtained. We describe a right-sided far lateral approach with minimal condylectomy for gross total resection of this lesion. We demonstrate the relationship of the tumor with the C2 nerve root, the spinal accessory nerve, and the cervical cord. We supplement the discussion with a 3D surgical video.

16.
Oper Neurosurg (Hagerstown) ; 22(1): e50, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34982920

RESUMEN

Cognard type V dural arteriovenous fistulae (dAVF) are typically located at the foramen magnum. Their presentation often mimics that of cervical myelopathy, and they can be easily misdiagnosed even if spinal vascular imaging is undertaken. Treatment typically involves endovascular embolization or surgery when embolization is not possible. We describe a case of a 67-yr-old man who presented with progressive symptoms of cervical myelopathy with a significant reduced ambulation and upper motor neuron signs. Imaging disclosed upper cervical cord edema, and angiography confirmed a Cognard type V dAVF with drainage into the perimedullary and spinal venous system. The dAVF was supplied by the hypoglossal division of the ascending pharyngeal artery. Endovascular treatment was believed to pose a risk of ischemic injury to the hypoglossal nerve, and therefore, surgery was offered. Informed consent was obtained. A far lateral approach was used to access the fistulous point. We describe the relevant vascular anatomy and the benefits of the far lateral approach for this lesion. We also demonstrate a tailored inferior condylectomy to gain access to the intracranial part of the hypoglossal canal, where the draining vein is expected to be found. We supplement the discussion with a 3D surgical video.

17.
World Neurosurg ; 158: 156-157, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34798340

RESUMEN

Medial orbitofrontal area arteriovenous malformations (AVMs) are located in the noneloquent cortex and typically drain superficially into Sylvian veins or the superior sagittal sinus, making them favorable for surgical treatment. However, while typically supplied by pial/cortical branches of the anterior cerebral artery (ACA), they can incorporate the recurrent artery of Heubner and other ACA perforators on their way to the anterior perforated substance located just posterior. We present a case of a 30-year-old female admitted with sudden collapse and intraventricular hemorrhage from a ruptured medial orbitofrontal area AVM. She was admitted to the intensive care unit and an external ventricular drain was placed to treat acute hydrocephalus. Catheter angiography demonstrated an AVM located just anteromedial to the termination of the internal carotid artery with a compact nidus and an associated intranidal flow aneurysm. Arterial supply originated from the orbitofrontal artery off the ACA, with medial lenticulostriates seen coursing past the nidus. Additional supply from the recurrent artery of Heubner could not be excluded. However, a hypodensity in the inferior frontal lobe seen on the presentation computed tomography scan was suggestive of a prior orbitofrontal infarct and thus cortical, rather than perforator, supply. In our practice, treatment of ruptured AVMs is dictated by the patients' clinical recovery and associated high-risk features (e.g., flow aneurysms). In this case, despite the presence of a flow aneurysm, treatment was delayed 18 days due to slow neurologic recovery and family preference. The patient remained in the intensive care unit under close neurologic observation. She was extubated on day 10, and the external ventricular drain was removed on day 12 after confirming resolution of intraventricular hemorrhage. Preoperatively the patient recovered to a Glasgow Coma Scale score of 15. Risks of treatment were discussed, and informed consent was obtained. The patient was treated using a standard pterional craniotomy. We describe the anatomic location of the lesion in the medial orbitofrontal area, the relationship to the olfactory tract and olfactory stria. We demonstrate olfactory tract dissection from its arachnoid cistern between the orbitofrontal lobe and gyrus rectus in order to access the lesion. Indocyanine green angiography is used to help surgical dissection and for quality control at the end of the procedure. We do not perform intraoperative angiography routinely; however, it can be a useful adjunct in deep and/or eloquent locations, which are difficult to image using videoangiography. Nevertheless, in the absence of intraoperative angiography close dissection directly over the nidus on the eloquent side ensures preservation of functional brain. We describe the microsurgical techniques of surgical treatment of AVMs, in particular the "cone" dissection technique of the AVM in order to allow identification of all feeding vessels and tracing "en passant" vessels from proximal to distal, as well as the use of intraoperative videoangiography to elucidate the nidus morphology and immediate postoperative quality control (Video 1, available at https://drive.google.com/file/d/1IXuLg84MwyMek1_Z1f1n7qssLThimvdx/view?usp=sharing).


Asunto(s)
Malformaciones Arteriovenosas Intracraneales , Adulto , Arteria Cerebral Anterior/diagnóstico por imagen , Arteria Cerebral Anterior/patología , Arteria Cerebral Anterior/cirugía , Angiografía Cerebral/métodos , Hemorragia Cerebral/complicaciones , Femenino , Lóbulo Frontal/diagnóstico por imagen , Lóbulo Frontal/patología , Lóbulo Frontal/cirugía , Humanos , Malformaciones Arteriovenosas Intracraneales/complicaciones , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Malformaciones Arteriovenosas Intracraneales/cirugía , Bulbo Olfatorio/patología
18.
Clin Ter ; 172(5): 489-494, 2021 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-34625783

RESUMEN

ABSTRACT: Bleedings occurring during a surgical intervention can be caused by haemostatic defects, but they are generally due to ineffective local haemostasis. Current coagulation systems may not be sufficient to achieve a good haemostasis, causing, at the same time, tissue dama-ge. Furthermore, the availability of such devices does not eliminate difficulties linked to the isolation of vessels, a crucial step of surgical procedures that require the removal of an organ or part of it, in case of inflammation or neoplasm. This difficulty is even more evident, and weighs more on operative times, when the surgeon engages with video-assisted surgery, where anatomical structures are difficult to detect and the manoeuvres of dissection and separation become more complex. The use of pre-operative radio-guided embolization of organ main arterial vessels with different embolic agents, could represent a great advantage, especially for mini-invasive procedures, such as laparoscopy in patients with high bleeding risk.


Asunto(s)
Embolización Terapéutica , Laparoscopía , Hemorragia , Humanos , Radiología Intervencionista
19.
World Neurosurg ; 154: e754-e761, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34358686

RESUMEN

BACKGROUND: Flow aneurysms (FAs) associated with brain arteriovenous malformations (AVMs) are thought to arise from increased hemodynamic stress due to high-flow shunting. This study aims to describe the changes in conservatively managed FAs after successful AVM treatment. METHODS: Patients with symptomatic AVMs and associated FAs who underwent successful treatment of the AVM between 2008 and 2017 were included. FA dimensions were measured on surveillance angiography to assess longitudinal changes. RESULTS: Thirty-two patients were identified with 48 FAs. Sixteen (33%) FAs were treated endovascularly; 18 (38%) FAs were treated surgically; and 14 (29%) FAs (11 patients) were monitored. FAs demonstrated a decrease in size from 5.0 mm to 3.8 mm (24%; P = 0.016) and 4.9 mm to 3.6 mm (27%; P = 0.013) in height and width, respectively, over a median 35 months. However, on subgroup analysis, only class IIb aneurysms demonstrated a significant decrease in size (51% reduction in largest diameter, P = 0.046) and only 3 FAs (21%) resolved. There were no hemorrhages observed during follow-up. CONCLUSIONS: While conservatively managed FAs demonstrated a reduction in size after the culprit AVM was treated, this was only significant in FAs located close to an AVM nidus (class IIb). There were no hemorrhages during the median 35 months' follow-up; however, long-term data are lacking. Our data support close observation of all conservatively managed aneurysms and a tailored approach based on the proximity to the nidus and observed changes in size.


Asunto(s)
Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/patología , Aneurisma Intracraneal/terapia , Malformaciones Arteriovenosas Intracraneales/complicaciones , Adulto , Anciano , Tratamiento Conservador , Procedimientos Endovasculares , Femenino , Humanos , Aneurisma Intracraneal/complicaciones , Malformaciones Arteriovenosas Intracraneales/cirugía , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
20.
Clin Ter ; 172(4): 329-335, 2021 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-34247216

RESUMEN

INTRODUCTION: Haemorrhoids are a very common disease, with a great economic burden. Many treatments have been developed for trying to solve the problem, being the standard not yet found. In 1995, Doppler-guided haemorrhoidal artery ligation was introduced, aiming to reduce postoperative pain and complications. In this work, an evolu-tion of the aforementioned surgical technique was described. MATERIALS AND METHODS: 183 patients treated with standard Doppler-Guided Haemorrhoidal Artery Ligation were statistically compared with 225 patients dealt with Colour Doppler-Guided Haemorrhoidal Artery Ligation. The procedures were performed under local anaes-thesia with patients in lithotomy position. A special proctoscope and a dedicated Colourdoppler US probe were employed in the second group. Superior haemorrhoidal artery terminal branches were con-secutively ligated according to provided technique in the first group and under vision in the second. In all cases, each ligation was followed by mucopexy. RESULTS: No significant differences between the two groups, in terms of post-operative pain, early complications (bleeding, urinary retention, incontinence) or patient satisfaction, were demonstrated. Recurrence rate was significantly higher in patients treated with stan-dard DG-HAL. No late complications (after one-year follow-up) were registered in both groups. CONCLUSIONS: Colour Doppler-Guided Haemorrhoidal Artery Li-gation represents an ideal management for 1-day surgery, and fulfils the requirements of minimally invasive surgery in patients with III-IV grade haemorrhoids. The absence of complications and the evidence of significant wellness of patients are the best advantages. Colour Doppler-Guided Haemorrhoidal Artery Ligation is a safe and easy procedure with good results and a very short-time training. It could be considered an easy and reliable method to treat symptomatic haemorrhoids.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Hemorreoidectomía/métodos , Hemorroides/cirugía , Ligadura/métodos , Arteria Mesentérica Inferior/cirugía , Ultrasonografía Doppler/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...