Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38595174

RESUMEN

OBJECTIVE: The aim of this study was to compare portal venous phase photon-counting CT (PCCT) using 20 cc less than weight-based contrast dosing with energy-integrating detector CT (EID-CT) using weight-based dosing by quantitative and qualitative analysis. METHODS: Fifty adult patients who underwent a reduced intravenous contrast dose portal venous phase PCCT from May 1, 2023, to August 10, 2023, and a prior portal-venous EID-CT with weight-based contrast dosing were retrospectively identified. Hounsfield units (HU) and noise (SD of HU) were obtained from region-of-interest measurements on 70-keV PCCT and EID-CT in 4 hepatic segments, the main and right portal vein, and both paraspinal muscles. Signal-to-noise and contrast-to-noise ratios were computed. Three abdominal radiologists qualitatively assessed overall image quality, hepatic enhancement, and confidence for metastasis identification on 5-point Likert scales. Readers also recorded the presence/absence of hepatic metastases. Quantitative variables were compared with paired t tests, and multiple comparisons were accounted for with a Bonferroni-adjusted α level of .0016. Ordinal logistic regression was used to evaluate qualitative assessments. Interreader agreement for hepatic metastases was calculated using Fleiss' κ. RESULTS: Fifty patients (32 women; mean [SD] age, 64 [13] years) were included. There was no significant difference in hepatic HU, portal vein HU, noise, and signal-to-noise or contrast-to-noise ratio between reduced contrast dose portal venous phase PCCT versus EID-CT (all Ps > 0.0016). Image quality, degree of hepatic enhancement, and confidence for metastasis identification were not different for reduced dose PCCT 70-keV images and EID-CT (P = 0.06-0.69). κ Value for metastasis identification was 0.86 (95% confidence interval, 0.70-1.00) with PCCT and 0.78 (95% confidence interval, 0.59-0.98) with EID-CT. CONCLUSION: Reduced intravenous contrast portal venous phase PCCT 70-keV images had similar attenuation and image quality as EID-CT with weight-based dosing. Metastases were identified with near-perfect agreement in reduced dose PCCT 70-keV images.

2.
Abdom Radiol (NY) ; 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38630314

RESUMEN

PURPOSE: To compare the inter-reader agreement of pancreatic adenocarcinoma resectability assessment at pancreatic protocol photon-counting CT (PCCT) with conventional energy-integrating detector CT (EID-CT). METHODS: A retrospective single institution database search identified all contrast-enhanced pancreatic mass protocol abdominal CT performed at an outpatient facility with both a PCCT and EID-CT from 4/11/2022 to 10/30/2022. Patients without pancreatic adenocarcinoma were excluded. Four fellowship-trained abdominal radiologists, blinded to CT type, independently assessed vascular tumor involvement (uninvolved, abuts ≤ 180°, encases > 180°; celiac, superior mesenteric artery (SMA), common hepatic artery (CHA), superior mesenteric vein (SMV), main portal vein), the presence/absence of metastases, overall tumor resectability (resectable, borderline resectable, locally advanced, metastatic), and diagnostic confidence. Fleiss's kappa was used to calculate inter-reader agreement. CTDIvol was recorded. Radiation dose metrics were compared with a two-sample t-test. A p < .05 indicated statistical significance. RESULTS: 145 patients (71 men, mean[SD] age: 66[9] years) were included. There was substantial inter-reader agreement, for celiac artery, SMA, and SMV involvement at PCCT (kappa = 0.61-0.69) versus moderate agreement at EID-CT (kappa = 0.56-0.59). CHA had substantial inter-reader agreement at both PCCT (kappa = 0.67) and EIDCT (kappa = 0.70). For metastasis identification, radiologists had substantial inter-reader agreement at PCCT (kappa = 0.78) versus moderate agreement at EID-CT (kappa = 0.56). CTDIvol for PCCT and EID-CT were 16.9[7.4]mGy and 29.8[26.6]mGy, respectively (p < .001). CONCLUSION: There was substantial inter-reader agreement for involvement of 4/5 major peripancreatic vessels (celiac artery, SMA, CHA, and SMV) at PCCT compared with 2/5 for EID-CT. PCCT also afforded substantial inter-reader agreement for metastasis detection versus moderate agreement at EID-CT with statistically significant radiation dose reduction.

3.
Eur J Radiol ; 175: 111437, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38520805

RESUMEN

PURPOSE: To calculate the prevalence of pancreatic cysts on photon counting CT (PCCT) and compare with that of 128-slice conventional energy-integrating detector CT (EIDCT). METHOD: A retrospective single institution database search identified all contrast-enhanced abdominal CT examinations performed at an outpatient facility that has both a PCCT and EIDCT between 4/11/2022 and 7/26/2022. The presence and size of pancreatic cysts were recorded. In patients with PCCT reported pancreatic cysts, prior CT imaging (EIDCT) was reviewed for reported pancreatic cysts. Fisher's exact test was used to compare the pancreatic cyst detection rate for PCCT and EIDCT. Wilcoxon rank sum test was used to compare cyst size and patient age. A p <.05 indicated statistical significance. RESULTS: 2494 patients were included. Our pancreatic cyst detection rate was 4.9 % (49/1009) with PCCT and 3.0 % (44/1485) for EIDCT (p =.017). For CT angiograms, pancreatic cysts were detected in 6.6 % (21/319) with PCCT and 0.0 % (0/141) with EIDCT (p <.001). Pancreatic cyst detection rate was not statistically different for portal venous, enterography, renal mass, pancreas, 3-phase liver, or venogram protocols (all p >.05). Mean[SD] pancreatic cyst size was 13.7[9.7]mm for PCCT and 15.3[14.7] for EIDCT (p =.95). 55.1 % (27/49) of PCCT and 61.4 % (27/44) of EIDCT that described pancreatic cysts had prior contrast-enhanced EIDCTs. Of these, 40.7 % (11/27) of PCCT and 14.8 % (4/27) of EIDCT described pancreatic cysts were not previously reported (p =.027). CONCLUSIONS: Photon-counting CT afforded greater pancreatic cyst detection than conventional energy-integrating detector CT, particularly with CT angiograms.


Asunto(s)
Quiste Pancreático , Fotones , Tomografía Computarizada por Rayos X , Humanos , Quiste Pancreático/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Anciano , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano de 80 o más Años , Medios de Contraste
4.
Abdom Radiol (NY) ; 49(5): 1762-1770, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38546824

RESUMEN

PURPOSE: Photon-counting detector CT (PCD CT) is a promising technology for abdominal imaging due to its ability to provide high spatial and contrast resolution images with reduced patient radiation exposure. However, there is currently no consensus regarding the optimal imaging protocols for PCD CT. This article aims to present the PCD CT abdominal imaging protocols used by two tertiary care academic centers in the United States. METHODS: A review of PCD CT abdominal imaging protocols was conducted by two abdominal radiologists at different academic institutions. Protocols were compared in terms of acquisition parameters and reconstruction settings. Both imaging centers independently selected similar protocols for PCD CT abdominal imaging, using QuantumPlus mode. RESULTS: There were some differences in the use of reconstruction kernels and iterative reconstruction levels, however the individual combination at each site resulted in similar image impressions. Overall, the imaging protocols used by both centers provide high-quality images with low radiation exposure. CONCLUSION: These findings provide valuable insights into the development of standardized protocols for PCD CT abdominal imaging, which can help to ensure consistent as well as high-quality imaging across different institutions and allow for future multicenter research collaborations.


Asunto(s)
Dosis de Radiación , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Radiografía Abdominal/métodos , Fotones , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Consenso , Estados Unidos , Centros Médicos Académicos
5.
Radiology ; 310(3): e232298, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38441091

RESUMEN

Gastrointestinal (GI) bleeding is the most common GI diagnosis leading to hospitalization within the United States. Prompt diagnosis and treatment of GI bleeding is critical to improving patient outcomes and reducing high health care utilization and costs. Radiologic techniques including CT angiography, catheter angiography, CT enterography, MR enterography, nuclear medicine red blood cell scan, and technetium-99m pertechnetate scintigraphy (Meckel scan) are frequently used to evaluate patients with GI bleeding and are complementary to GI endoscopy. However, multiple management guidelines exist, which differ in the recommended utilization of these radiologic examinations. This variability can lead to confusion as to how these tests should be used in the evaluation of GI bleeding. In this document, a panel of experts from the American College of Gastroenterology and Society of Abdominal Radiology provide a review of the radiologic examinations used to evaluate for GI bleeding including nomenclature, technique, performance, advantages, and limitations. A comparison of advantages and limitations relative to endoscopic examinations is also included. Finally, consensus statements and recommendations on technical parameters and utilization of radiologic techniques for GI bleeding are provided. © Radiological Society of North America and the American College of Gastroenterology, 2024. Supplemental material is available for this article. This article is being published concurrently in American Journal of Gastroenterology and Radiology. The articles are identical except for minor stylistic and spelling differences in keeping with each journal's style. Citations from either journal can be used when citing this article. See also the editorial by Lockhart in this issue.


Asunto(s)
Hemorragia Gastrointestinal , Radiología , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Angiografía , Catéteres
6.
ACG Case Rep J ; 11(1): e01247, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38179265

RESUMEN

Although extraintestinal manifestations of inflammatory bowel disease (IBD) are common, pulmonary IBD is extremely rare. Owing to its nonspecific clinical, radiologic, and pathologic features, pulmonary IBD is difficult to diagnose and may mimic more concerning disease processes. We present a rare case of a patient with known Crohn's disease whose initial presentation was highly suspicious for malignancy before further investigation revealed pulmonary IBD.

7.
AJR Am J Roentgenol ; 222(2): e2330422, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38054957

RESUMEN

MR enterography (MRE) protocols used in patients with Crohn disease are burdened by long acquisition time, high cost, and suboptimal patient experience. For several indications, highly diagnostic MRE can be performed in five or fewer sequences, without IV contrast material or antiperistaltic medication and with an examination room time of less than 12 minutes. As such, MRE could be more patient friendly, more frequently performed, and require fewer health care resources.


Asunto(s)
Enfermedad de Crohn , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Medios de Contraste
8.
Abdom Radiol (NY) ; 49(3): 868-874, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38006415

RESUMEN

PURPOSE: To quantitatively and qualitatively compare the degree of iodine removal in the collecting system from PCCT urographic phase-derived virtual noncontrast (VNC) images obtained at 140 kV versus 120 kV. METHODS: A retrospective PACS search identified adult patients (>18 years) who underwent a PCCT urogram for hematuria from 4/2022 to 4/2023 with available urographic phase-derived VNC images in PACS. Tube voltage (120 kV, 140 kV), body mass index, CTDIvol, dose length product (DLP), and size-specific dose estimate (SSDE) were recorded. Hounsfield Unit (HU) in both renal pelvises and the urinary bladder on urographic-derived VNC were recorded. Three radiologists qualitatively assessed the degree of iodine removal (renal pelvis, urinary bladder) and diagnostic confidence for urinary stone detection. Continuous variables were compared for 140 kV versus 120 kV with the Wilcoxon rank sum test. A p < .05 indicated statistical significance. RESULTS: 63 patients (34 male; median (Q1, Q3) age: 30 (26, 34) years; 140 kV/120 kV: 30 patients/33 patients) were included. BMI, CTDIvol, DLP, and SSDE were not different for 140 kV and 120 kV (all p > .05). Median (Q1, Q3) collecting system HU (renal pelvis and bladder) was 0.9 (- 3.6, 4.4) HU at 140 kV and 10.5 (3.6, 26.7) HU at 120 kV (p = .04). Diagnostic confidence for urinary calculi was 4.6 [1.1] at 140 kV and 4.1 [1.4] at 120 kV (p = .005). Diagnostic confidence was 5/5 (all readers) in 82.2% (74/90) at 140 kV and 59.6% (59/99) at 120 kV (p < .001). CONCLUSION: PCCT urographic phase-derived VNC images obtained at 140 kV had better collecting system iodine removal than 120 kV with similar patient radiation exposure. With excellent PCCT urographic phase iodine removal at 140 kV, consideration can be made to utilize a single-phase CT urogram in young patients.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Cálculos Urinarios , Adulto , Humanos , Masculino , Estudios Retrospectivos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos
9.
J Comput Assist Tomogr ; 48(2): 251-256, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38013203

RESUMEN

PURPOSE: This study aimed to compare the image quality of portal venous phase-derived virtual noncontrast (VNC) images from photon-counting computed tomography (PCCT) with energy-integrating dual-energy computed tomography (EI-DECT) in the same patient using quantitative and qualitative analyses. METHODS: Consecutive patients retrospectively identified with available portal venous phase-derived VNC images from both PCCT and EI-DECT were included. Patients without available VNC in picture archiving and communication system in PCCT or prior EI-DECT and non-portal venous phase acquisitions were excluded. Three fellowship-trained radiologists blinded to VNC source qualitatively assessed VNC images on a 5-point scale for overall image quality, image noise, small structure delineation, noise texture, artifacts, and degree of iodine removal. Quantitative assessment used region-of-interest measurements within the aorta at 4 standard locations, both psoas muscles, both renal cortices, spleen, retroperitoneal fat, and inferior vena cava. Attenuation (Hounsfield unit), quantitative noise (Hounsfield unit SD), contrast-to-noise ratio (CNR) (CNR vascular , CNR kidney , CNR spleen , CNR fat ), signal-to-noise ratio (SNR) (SNR vascular , SNR kidney , SNR spleen , SNR fat ), and radiation dose were compared between PCCT and EI-DECT with the Wilcoxon signed rank test. A P < 0.05 indicated statistical significance. RESULTS: A total of 74 patients (27 men; mean ± SD age, 63 ± 13 years) were included. Computed tomography dose index volumes for PCCT and EI-DECT were 9.2 ± 3.5 mGy and 9.4 ± 9.0 mGy, respectively ( P = 0.06). Qualitatively, PCCT VNC images had better overall image quality, image noise, small structure delineation, noise texture, and fewer artifacts (all P < 0.00001). Virtual noncontrast images from PCCT had lower attenuation (all P < 0.05), noise ( P = 0.006), and higher CNR ( P < 0.0001-0.04). Contrast-enhanced structures had lower SNR on PCCT ( P = 0.001, 0.002), reflecting greater contrast removal. The SNRfat (nonenhancing) was higher for PCCT than EI-DECT ( P < 0.00001). CONCLUSIONS: Virtual noncontrast images from PCCT had improved image quality, lower noise, improved CNR and SNR compared with those derived from EI-DECT.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Relación Señal-Ruido , Aorta , Riñón , Imagen Radiográfica por Emisión de Doble Fotón/métodos
10.
Abdom Radiol (NY) ; 49(1): 271-278, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37814149

RESUMEN

PURPOSE: To determine optimal iodine density thresholds for active inflammation in CD patients with PCCT enterography and determine if iodine density can be used to stratify CD activity severity. METHODS: A retrospective PACS search identified patients with CD imaged with PCCT enterography from 4/11/2022 to 10/30/2022 and with clinical notes, endoscopic/surgical pathology and available source PCCT data for iodine density analysis. Two abdominal radiologists with expertise in CD each drew two region of interest measurements within the visibly most affected region of terminal or neoterminal ileum wall on commercially available system (SyngoVia). Radiologists were blinded to clinical information and pathologic findings. Disease activity and severity were recorded from the pathology report. Harvey-Bradshaw Index, medications, and laboratory values were recorded. Receiver operating characteristic (ROC) curves were utilized to determine the optimum iodine density threshold for active inflammation and mild versus moderate-to-severe inflammation. Intra- and inter-reader agreement was assessed by intra-class correlation coefficient (ICC). RESULTS: 23 CD patients (15 females; mean [SD] age: 52 [17] years) imaged with PCCT enterography were included. 15/23 had active inflammation: 9/15 mild, 4/15 moderate, and 2/15 severe active inflammation. The optimal iodine density threshold for active inflammation was 2.7 mg/mL, with 97% sensitivity, 100% specificity, and 98% accuracy (AUC = 1.00). The optimal iodine density threshold for distinguishing mild from moderate-to-severe inflammation was 3.4 mg/mL, with 83% sensitivity, 89% specificity, and 87% accuracy (AUC = 0.85). Intra-reader reliability (R1/R2) ICC was 0.81/0.86. Inter-reader reliability ICC was 0.94. CONCLUSION: Iodine density from PCCT enterography can distinguish mild from moderate-to-severe active inflammation.


Asunto(s)
Enfermedad de Crohn , Yodo , Femenino , Humanos , Persona de Mediana Edad , Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/patología , Estudios Retrospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Inflamación/diagnóstico por imagen , Inflamación/patología
11.
Ann Plast Surg ; 92(1): 68-74, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38117047

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the role of body mass index (BMI) in predicting postoperative complications following myocutaneous free flap transfer. In addition, we sought to identify certain body composition variables that may be used to stratify patients into low- versus high-risk for gracilis myocutaneous free flap with skin paddle failure. METHODS: Using the National Surgical Quality Improvement Program database, we collected data for all patients who underwent myocutaneous free flap transfer from 2015 to 2021. Demographic data, medical history, surgical characteristics, and postoperative outcomes, including complications, reoperations, and readmissions, were collected. Body mass index was correlated with outcome measures to determine its role in predicting myocutaneous free flap reliability. Subsequently, we retrospectively obtained measurements of perigracilis anatomy in patients who underwent computed tomography angiography bilateral lower extremity scans with intravenous contrast at our institution. We compared body composition data with mathematical equations calculating the potential area along the skin of the thigh within which the gracilis perforator may be found. RESULTS: Across the United States, 1549 patients underwent myocutaneous free flap transfer over the 7-year study period. Being in obesity class III (BMI ≥40 kg/m2) was associated with a 4-times greater risk of flap complications necessitating a return to the operating room compared with being within the normal BMI range. In our computed tomography angiography analysis, average perigracilis adipose thickness was 18.3 ± 8.0 mm. Adipose thickness had a strong, positive exponential relationship with the area of skin within which the perforator may be found. CONCLUSIONS: In our study, higher BMI was associated with decreased myocutaneous free flap reliability. Specifically, inner thigh adipose thickness can be used to estimate the area along the skin within which the gracilis perforator may be found. This variable, along with BMI, can be used to identify patients who are considered high-risk for flap failure and who may benefit from additional postoperative monitoring, such as the use of a color flow Doppler probe and more frequent and prolonged skin paddle monitoring.


Asunto(s)
Colgajos Tisulares Libres , Mamoplastia , Colgajo Miocutáneo , Colgajo Perforante , Humanos , Colgajos Tisulares Libres/efectos adversos , Índice de Masa Corporal , Estudios Retrospectivos , Reproducibilidad de los Resultados , Mamoplastia/métodos , Colgajo Miocutáneo/trasplante , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Obesidad/complicaciones , Obesidad/cirugía , Algoritmos , Colgajo Perforante/cirugía
12.
J Am Coll Radiol ; 20(11S): S471-S480, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-38040465

RESUMEN

The differential diagnosis for left lower quadrant pain is wide and conditions range from the benign and self-limited to life-threatening surgical emergencies. Along with patient history, physical examination, and laboratory tests, imaging is often critical to limit the differential diagnosis and identify life-threatening abnormalities. This document will discuss the guidelines for the appropriate use of imaging in the initial workup for patients who present with left lower quadrant pain, patients with suspected diverticulitis, and patients with suspected complications from diverticulitis. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Asunto(s)
Diverticulitis , Sociedades Médicas , Humanos , Dolor Abdominal , Diagnóstico por Imagen , Medicina Basada en la Evidencia , Estados Unidos
13.
Radiol Clin North Am ; 61(6): 1031-1049, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37758355

RESUMEN

The use of dual-energy computed tomography (CT) allows for reconstruction of energy- and material-specific image series. The combination of low-energy monochromatic images, iodine maps, and virtual unenhanced images can improve lesion detection and disease characterization in the gastrointestinal tract in comparison with single-energy CT.

14.
Radiol Clin North Am ; 61(6): 945-961, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37758362

RESUMEN

Compared to conventional single-energy CT (SECT), dual-energy CT (DECT) provides additional information to better characterize imaged tissues. Approaches to DECT acquisition vary by vendor and include source-based and detector-based systems, each with its own advantages and disadvantages. Despite the different approaches to DECT acquisition, the most utilized DECT images include routine SECT equivalent, virtual monoenergetic, material density (eg, iodine map), and virtual non-contrast images. These images are generated either through reconstructions in the projection or image domains. Designing and implementing an optimal DECT workflow into routine clinical practice depends on radiologist and technologist input with special considerations including appropriate patient and protocol selection and workflow automation. In addition to better tissue characterization, DECT provides numerous advantages over SECT such as the characterization of incidental findings and dose reduction in radiation and iodinated contrast.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Dosis de Radiación , Imagen Radiográfica por Emisión de Doble Fotón/métodos
15.
Abdom Radiol (NY) ; 48(9): 3000-3004, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37340153

RESUMEN

The sections of this special issue on the ileal pouch demonstrate that in the nearly 45 years since the ileal pouch has been utilized to treat patients with colitis and familial adenomatous polyposis, a substantial number of patients experience both short- and long-term morbidity and that imaging plays an important role in their management. Further, referral centers are encountering an increasing number of patients with pouch and peri-pouch complications and dysfunction. Many of these patients have had their pouches for years, and many have experienced a reduced quality of life as a result of their symptoms.As we look to the future, what are the specific questions that arise from this compilation of experience from institutions that see large numbers of patients with an ileal pouch? In what areas are we deficient? In what areas are we using the wrong methods? What should we be doing differently?


Asunto(s)
Poliposis Adenomatosa del Colon , Colitis , Reservorios Cólicos , Proctocolectomía Restauradora , Humanos , Calidad de Vida , Poliposis Adenomatosa del Colon/complicaciones , Poliposis Adenomatosa del Colon/cirugía , Colitis/complicaciones
16.
Abdom Radiol (NY) ; 48(7): 2284-2291, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37148320

RESUMEN

OBJECTIVE: To analyze the findings of proctitis in patients with laboratory-confirmed Mpox and correlate the patient clinical presentation and laboratory findings. METHODS: 21 patients with PCR-positive Mpox who obtained abdominopelvic CT were retrospectively identified by electronic medical record search. Three radiologists independently evaluated CT images, measuring rectal wall thickness (cm), degree of perirectal fat stranding on a 5-point Likert scale, and size of perirectal lymph nodes (cm, short axis). Mann-Whitney U-test (Wilcoxon rank sum test) was used to assess the association of rectal wall thickness and perirectal fat standing between patients with rectal symptoms and patients without rectal symptoms. RESULTS: 20 of 21 patients presented with perirectal fat stranding, with mean Likert score of 3.0 ± 1.4, indicating moderate perirectal stranding. Mean transverse rectal wall thickness was 1.1 ± 0.5 cm (range 0.3-2.3 cm); it was thicker among patients with HIV (1.2 cm vs 0.7 cm; p = .019). Mean perirectal fat stranding was greater among patients presenting with HIV, and with rectal symptoms, though not significantly so. 17/21 (81%) patients had abnormal mesorectal lymph nodes by at least two of three readers, with mean short-axis measurement 1.0 ± 0.3 cm (range 0.5-1.6 cm). Multiple linear regression showed no significant correlation between rectal thickness and laboratory values or HIV status. CONCLUSION: Nearly all patients with Mpox who presented with additional symptoms warranting a CT demonstrated proctitis. Degree of proctitis varied greatly within the cohort, with greatest thickening among patients with HIV. Physicians should have a high suspicion for proctitis in patients with suspected Mpox.


Asunto(s)
Infecciones por VIH , Mpox , Proctitis , Neoplasias del Recto , Humanos , Neoplasias del Recto/patología , Estudios Retrospectivos , Monkeypox virus , Proctitis/diagnóstico por imagen , Tomografía Computarizada por Rayos X
17.
Radiographics ; 43(6): e220192, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37167088

RESUMEN

Gastrointestinal (GI) bleeding is a potentially life-threatening condition accounting for more than 300 000 annual hospitalizations. Multidetector abdominopelvic CT angiography is commonly used in the evaluation of patients with GI bleeding. Given that many patients with severe overt GI bleeding are unlikely to tolerate bowel preparation, and inpatient colonoscopy is frequently limited by suboptimal preparation obscuring mucosal visibility, CT angiography is recommended as a first-line diagnostic test in patients with severe hematochezia to localize a source of bleeding. Assessment of these patients with conventional single-energy CT systems typically requires the performance of a noncontrast series followed by imaging during multiple postcontrast phases. Dual-energy CT (DECT) offers several potential advantages for performing these examinations. DECT may eliminate the need for a noncontrast acquisition by allowing the creation of virtual noncontrast (VNC) images from contrast-enhanced data, affording significant radiation dose reduction while maintaining diagnostic accuracy. VNC images can help radiologists to differentiate active bleeding, hyperattenuating enteric contents, hematomas, and enhancing masses. Additional postprocessing techniques such as low-kiloelectron voltage virtual monoenergetic images, iodine maps, and iodine overlay images can increase the conspicuity of contrast material extravasation and improve the visibility of subtle causes of GI bleeding, thereby increasing diagnostic confidence and assisting with problem solving. GI bleeding can also be diagnosed with routine single-phase DECT scans by constructing VNC images and iodine maps. Radiologists should also be aware of the potential pitfalls and limitations of DECT. ©RSNA, 2023 Quiz questions for this article are available through the Online Learning Center.


Asunto(s)
Hemorragia Gastrointestinal , Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagen , Intestino Delgado , Yodo , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos
18.
Abdom Radiol (NY) ; 48(7): 2219-2227, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37097450

RESUMEN

PURPOSE: To compare dual-source dual-energy CT enterography (dsDECTE) obtained iodine density (I) (mg/mL) and I normalized to the aorta (I%) with Crohn's disease (CD) phenotypes defined by the SAR-AGA small bowel CD consensus statement. METHODS: Fifty CD patients (31 male, 19 female; mean [SD] age: 50.4 [15.2] years) who underwent dsDECTE were retrospectively identified. Two abdominal radiologists assigned CD phenotypes: no active inflammation (group-2), active inflammation without (group-3) or with luminal narrowing (group-4), stricture with active inflammation (group-5), stricture without active inflammation (group-1), and penetrating disease (group-6). Semiautomatic prototype software was used to determine the median I and I% of CD-affected small bowel mucosa for each patient. The means of the I and I% medians were compared among 4 groups ("1 + 2", "3 + 4", "5", "6") using one-way ANOVA (significance level 0.05 for each outcome) for each outcome individually followed by Tukey's range test for pairwise comparisons with adjusted p-values (overall alpha = 0.05). RESULTS: Mean [SD] I was 2.14 [1.07] mg/mL for groups 1 + 2 (n = 16), 3.54 [1.71] mg/mL for groups 3 + 4 (n = 15), 5.5 [3.27] mg/mL for group- "5" (n = 9), and 3.36 [1.43] mg/mL for group-"6" (n = 10) (ANOVA p = .001; group "1 + 2" versus "5" adj-p = .0005). Mean [SD] I% was 21.2 [6.13]% for groups 1 + 2, 39.47 [9.71]% for groups 3 + 4, 40.98 [11.76]% for group-5, and 35.01 [7.58]% for group-6 (ANOVA p < .0001; groups "1 + 2" versus "3 + 4" adj-p < .0001, group "1 + 2" versus "5" adj-p < .0001, and groups "1 + 2" versus "6" adj-p = .002). CONCLUSION: Iodine density obtained from dsDECTE significantly differed among CD phenotypes defined by SAR-AGA, with I (mg/mL) increasing with phenotype severity and decreasing for penetrating disease. I and I% can be used to phenotype CD.


Asunto(s)
Enfermedad de Crohn , Yodo , Masculino , Femenino , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Constricción Patológica , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Inflamación , Fenotipo , Imagen por Resonancia Magnética
19.
Abdom Radiol (NY) ; 48(9): 2935-2943, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37043026

RESUMEN

This manuscript is part of the ileal pouch symposium and will describe the water-soluble contrast enema, CT, and small bowel series. MRI and other imaging modalities are discussed elsewhere in the symposium. Water-soluble contrast enema and CT are excellent for the evaluation of the ileal pouch. Contrast enema and CT with anal contrast administration can allow for anastomotic integrity and pouch assessment. Pre-pouch ileum, extra-intestinal manifestations, and acute symptomatology are best assessed with CT. The contrast small bowel examination is of limited utility in pouch patients and should not be performed. Indications, imaging technique, and anatomic pouch assessment with water-soluble contrast enema, CT, and contrast small bowel examination will be reviewed here.


Asunto(s)
Enema , Íleon , Humanos , Enema/métodos , Canal Anal/cirugía , Tomografía Computarizada por Rayos X , Agua
20.
Abdom Radiol (NY) ; 48(9): 2978-2985, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36871233

RESUMEN

PURPOSE: Given that ileal pouch-anal anastomosis (IPAA) surgery is a technically challenging and high-morbidity procedure, there are numerous pertinent imaging findings that need to be clearly and efficiently communicated to the IBD surgeons for essential patient management and surgical planning. Structured reporting has been increasingly used over the past decade throughout various radiology subspecialties to improve reporting clarity and completeness. We compare structured versus non-structured reporting of pelvic MRI for ileal pouch to evaluate for clarity and effectiveness. METHODS: 164 consecutive pelvic MRI's for ileal pouch evaluation, excluding subsequent exams for the same patient, acquired between 1/1/2019 and 7/31/2021 at one institution were included, before and after implementation (11/15/2020) of a structured reporting template, which was created with institutional IBD surgeons. Reports were assessed for the presence of 18 key features required for complete ileal pouch assessment: anastomosis (IPAA, tip of J, pouch body), cuff (length, cuffitis), pouch body (size, pouchitis, stricture), pouch inlet/pre-pouch ileum (stricture, inflammation, sharp angulation), pouch outlet (stricture), peripouch mesentery (position, mesentery twist), pelvic abscess, peri-anal fistula, pelvic lymph nodes, and skeletal abnormalities. Subgroup analysis was performed based on reader experience and divided into three categories: experienced (n = 2), other intra-institutional (n = 20), or affiliate site (n = 6). RESULTS: 57 (35%) structured and 107 (65%) non-structured pelvic MRI reports were reviewed. Structured reports contained 16.6 [SD:4.0] key features whereas non-structured reports contained 6.3 [SD:2.5] key features (p < .001). The largest improvement following template implementation was for reporting sharp angulation of the pouch inlet (91.2% vs. 0.9%, p < .001), tip of J suture line and pouch body anastomosis (both improved to 91.2% from 3.7%). Structured versus non-structured reports contained mean 17.7 versus 9.1 key features for experienced readers, 17.0 versus 5.9 for other intra-institutional readers, and 8.7 versus 5.3 for affiliate site readers. CONCLUSION: Structured reporting of pelvic MRI guides a systematic search pattern and comprehensive evaluation of ileal pouches, and therefore facilitates surgical planning and clinical management. This standardized reporting template can serve as baseline at other institutions for adaptation based on specific radiology and surgery preferences, fostering a collaborative environment between radiology and surgery, and ultimately improving patient care.


Asunto(s)
Reservorios Cólicos , Enfermedades Inflamatorias del Intestino , Proctocolectomía Restauradora , Humanos , Constricción Patológica/cirugía , Proctocolectomía Restauradora/métodos , Imagen por Resonancia Magnética , Complicaciones Posoperatorias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...