Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Sci Technol ; 56(19): 13644-13653, 2022 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-36150089

RESUMEN

Amines are frequently included in formulations of the herbicides glyphosate, 2,4-D, and dicamba to increase herbicide solubility and reduce herbicide volatilization by producing herbicide-amine salts. Amines, which typically have higher vapor pressures than the corresponding herbicides, could potentially volatilize from these salts and enter the atmosphere, where they may impact atmospheric chemistry, human health, and climate. Amine volatilization from herbicide-amine salts may additionally contribute to volatilization of dicamba and 2,4-D. In this study, we established that amines applied in herbicide-amine salt formulations undergo extensive volatilization. Both dimethylamine and isopropylamine volatilized when aqueous salt solutions were dried to a residue at ∼20 °C, while lower-vapor pressure amines like diglycolamine and n,n-bis-(3-aminopropyl)methylamine did not. However, all four amines volatilized from salt residues at 40-80 °C. Because amine loss typically exceeded herbicide loss, we proposed that neutral amines dominated volatilization and that higher temperatures altered their protonation state and vapor pressure. Due to an estimated 4.0 Gg N/yr applied as amines to major U.S. crops, amine emissions from herbicide-amine salts may be important on regional scales. Further characterization of worldwide herbicide-amine use would enable this contribution to be compared to the 285 Gg N/yr of methylamines emitted globally.


Asunto(s)
Dicamba , Herbicidas , Ácido 2,4-Diclorofenoxiacético , Aminas , Dicamba/química , Dimetilaminas , Herbicidas/química , Humanos , Metilaminas , Sales (Química) , Volatilización
2.
BMJ Open ; 11(9): e045557, 2021 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-34475144

RESUMEN

OBJECTIVE: The COVID-19 pandemic has precipitated widespread shortages of filtering facepiece respirators (FFRs) and the creation and sharing of proposed substitutes (novel designs, repurposed materials) with limited testing against regulatory standards. We aimed to categorically test the efficacy and fit of potential N95 respirator substitutes using protocols that can be replicated in university laboratories. SETTING: Academic medical centre with occupational health-supervised fit testing along with laboratory studies. PARTICIPANTS: Seven adult volunteers who passed quantitative fit testing for small-sized (n=2) and regular-sized (n=5) commercial N95 respirators. METHODS: Five open-source potential N95 respirator substitutes were evaluated and compared with commercial National Institute for Occupational Safety and Health (NIOSH)-approved N95 respirators as controls. Fit testing using the 7-minute standardised Occupational Safety and Health Administration fit test was performed. In addition, protocols that can be performed in university laboratories for materials testing (filtration efficiency, air resistance and fluid resistance) were developed to evaluate alternate filtration materials. RESULTS: Among five open-source, improvised substitutes evaluated in this study, only one (which included a commercial elastomeric mask and commercial HEPA filter) passed a standard quantitative fit test. The four alternative materials evaluated for filtration efficiency (67%-89%) failed to meet the 95% threshold at a face velocity (7.6 cm/s) equivalent to that of a NIOSH particle filtration test for the control N95 FFR. In addition, for all but one material, the small surface area of two 3D-printed substitutes resulted in air resistance that was above the maximum in the NIOSH standard. CONCLUSIONS: Testing protocols such as those described here are essential to evaluate proposed improvised respiratory protection substitutes, and our testing platform could be replicated by teams with similar cross-disciplinary research capacity. Healthcare professionals should be cautious of claims associated with improvised respirators when suggested as FFR substitutes.


Asunto(s)
COVID-19 , Exposición Profesional , Dispositivos de Protección Respiratoria , Adulto , Diseño de Equipo , Humanos , Respiradores N95 , Pandemias/prevención & control , SARS-CoV-2 , Estados Unidos , Ventiladores Mecánicos
3.
Materials (Basel) ; 14(8)2021 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-33918714

RESUMEN

The use of facemasks is proven to mitigate the spread of the coronavirus and other biological agents that cause disease. Various forms of facemasks, made using different materials, are being used extensively, and it is important to determine their performance characteristics. The size-dependent filtration efficiency and breathing resistance of household sterilization wrap fabrics, and isolation media (American Society for Testing and Materials (ASTM)- and non-ASTM-rated), were measured in filter-holder- and mannequin-in-chamber-based systems, focusing on particles sizes between 20 nm and 2 µm. Double-layer MERV-14 (Minimum Efficiency Reporting Values with rating 14) showed the highest filtration efficiency (94.9-73.3%) amongst household filter media, whereas ASTM-rated isolation masks showed the highest filtration efficiencies (95.6-88.7) amongst all the masks considered. Filtration efficiency of 3D-printed masks with replaceable filter media was found to depend on the degree of sealing around the media holder, which depended on the material's compressibility. Filtration efficiencies of triple-layer combinations (95.8-85.3%) follow a profile similar to single layers but with improved filtration efficiencies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA