Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PLOS Digit Health ; 3(8): e0000558, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39102377

RESUMEN

Online symptom checkers are increasingly popular health technologies that enable patients to input their symptoms to produce diagnoses and triage advice. However, there is concern regarding the performance and safety of symptom checkers in diagnosing and triaging patients with life-threatening conditions. This retrospective cross-sectional study aimed to evaluate and compare commercially available symptom checkers for performance in diagnosing and triaging myocardial infarctions (MI). Symptoms and biodata of MI patients were inputted into 8 symptom checkers identified through a systematic search. Anonymised clinical data of 100 consecutive MI patients were collected from a tertiary coronary intervention centre between 1st January 2020 to 31st December 2020. Outcomes included (1) diagnostic sensitivity as defined by symptom checkers outputting MI as the primary diagnosis (D1), or one of the top three (D3), or top five diagnoses (D5); and (2) triage sensitivity as defined by symptom checkers outputting urgent treatment recommendations. Overall D1 sensitivity was 48±31% and varied between symptom checkers (range: 6-85%). Overall D3 and D5 sensitivity were 73±20% (34-92%) and 79±14% (63-94%), respectively. Overall triage sensitivity was 83±13% (55-91%). 24±16% of atypical cases had a correct D1 though for female atypical cases D1 sensitivity was only 10%. Atypical MI D3 and D5 sensitivity were 44±21% and 48±24% respectively and were significantly lower than typical MI cases (p<0.01). Atypical MI triage sensitivity was significantly lower than typical cases (53±20% versus 84±15%, p<0.01). Female atypical cases had significantly lower diagnostic and triage sensitivity than typical female MI cases (p<0.01).Given the severity of the pathology, the diagnostic performance of symptom checkers for correctly diagnosing an MI is concerningly low. Moreover, there is considerable inter-symptom checker performance variation. Patients presenting with atypical symptoms were under-diagnosed and under-triaged, especially if female. This study highlights the need for improved clinical performance, equity and transparency associated with these technologies.

2.
J Clin Endocrinol Metab ; 107(1): e71-e83, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34427658

RESUMEN

CONTEXT: Antenatal complications such as hypertensive disorders of pregnancy (HDP), fetal growth restriction (FGR), gestational diabetes (GDM), and preterm birth (PTB) are associated with placental dysfunction. Kisspeptin has emerged as a putative marker of placental function, but limited data exist describing circulating kisspeptin levels across all 3 trimesters in women with antenatal complications. OBJECTIVE: We aimed to assess whether kisspeptin levels are altered in women with antenatal complications. METHODS: Women with antenatal complications (n = 105) and those with uncomplicated pregnancies (n = 265) underwent serial ultrasound scans and blood sampling at the Early Pregnancy Assessment Unit at Hammersmith Hospital, UK, at least once during each trimester (March 2014 to March 2017). The women with antenatal complications (HDP [n = 32], FGR [n = 17], GDM [n = 35], PTB [n = 11], and multiple complications [n=10]) provided 373 blood samples and the controls provided 930 samples. Differences in circulating kisspeptin levels were assessed. RESULTS: Third-trimester kisspeptin levels were higher than controls in HDP but lower in FGR. The odds of HDP adjusted for gestational age, maternal age, ethnicity, BMI, smoking, and parity were increased by 30% (95% CI, 16%-47%; P < 0.0001), and of FGR were reduced by 28% (95% CI, 4-46%; P = 0.025), for every 1 nmol/L increase in plasma kisspeptin. Multiple of gestation-specific median values of kisspeptin were higher in pregnancies affected by PTB (P = 0.014) and lower in those with GDM (P = 0.020), but not significantly on multivariable analysis. CONCLUSION: We delineate changes in circulating kisspeptin levels at different trimesters and evaluate the potential of kisspeptin as a biomarker for antenatal complications.


Asunto(s)
Diabetes Gestacional/fisiopatología , Retardo del Crecimiento Fetal/epidemiología , Hipertensión Inducida en el Embarazo/epidemiología , Kisspeptinas/sangre , Enfermedades Placentarias/epidemiología , Preeclampsia/fisiopatología , Nacimiento Prematuro/epidemiología , Adulto , Biomarcadores/sangre , Estudios de Casos y Controles , Femenino , Retardo del Crecimiento Fetal/patología , Estudios de Seguimiento , Edad Gestacional , Humanos , Hipertensión Inducida en el Embarazo/patología , Recién Nacido , Londres/epidemiología , Masculino , Enfermedades Placentarias/patología , Embarazo , Trimestres del Embarazo , Nacimiento Prematuro/patología , Pronóstico
3.
JMIR Public Health Surveill ; 7(7): e29942, 2021 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-34081599

RESUMEN

BACKGROUND: Recent emergency authorization and rollout of COVID-19 vaccines by regulatory bodies has generated global attention. As the most popular video-sharing platform globally, YouTube is a potent medium for the dissemination of key public health information. Understanding the nature of available content regarding COVID-19 vaccination on this widely used platform is of substantial public health interest. OBJECTIVE: This study aimed to evaluate the reliability and quality of information on COVID-19 vaccination in YouTube videos. METHODS: In this cross-sectional study, the phrases "coronavirus vaccine" and "COVID-19 vaccine" were searched on the UK version of YouTube on December 10, 2020. The 200 most viewed videos of each search were extracted and screened for relevance and English language. Video content and characteristics were extracted and independently rated against Health on the Net Foundation Code of Conduct and DISCERN quality criteria for consumer health information by 2 authors. RESULTS: Forty-eight videos, with a combined total view count of 30,100,561, were included in the analysis. Topics addressed comprised the following: vaccine science (n=18, 58%), vaccine trials (n=28, 58%), side effects (n=23, 48%), efficacy (n=17, 35%), and manufacturing (n=8, 17%). Ten (21%) videos encouraged continued public health measures. Only 2 (4.2%) videos made nonfactual claims. The content of 47 (98%) videos was scored to have low (n=27, 56%) or moderate (n=20, 42%) adherence to Health on the Net Foundation Code of Conduct principles. Median overall DISCERN score per channel type ranged from 40.3 (IQR 34.8-47.0) to 64.3 (IQR 58.5-66.3). Educational channels produced by both medical and nonmedical professionals achieved significantly higher DISCERN scores than those of other categories. The highest median DISCERN scores were achieved by educational videos produced by medical professionals (64.3, IQR 58.5-66.3) and the lowest median scores by independent users (18, IQR 18-20). CONCLUSIONS: The overall quality and reliability of information on COVID-19 vaccines on YouTube remains poor. Videos produced by educational channels, especially by medical professionals, were higher in quality and reliability than those produced by other sources, including health-related organizations. Collaboration between health-related organizations and established medical and educational YouTube content producers provides an opportunity for the dissemination of high-quality information on COVID-19 vaccination. Such collaboration holds potential as a rapidly implementable public health intervention aiming to engage a wide audience and increase public vaccination awareness and knowledge.


Asunto(s)
Vacunas contra la COVID-19/administración & dosificación , Información de Salud al Consumidor/normas , Difusión de la Información/métodos , Salud Pública , Medios de Comunicación Sociales , Grabación en Video , COVID-19/epidemiología , COVID-19/prevención & control , Estudios Transversales , Humanos , Reproducibilidad de los Resultados , Reino Unido/epidemiología
4.
Fertil Steril ; 116(3): 809-819, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34053677

RESUMEN

OBJECTIVE: To compare the performance of kisspeptin and beta human chorionic gonadotropin (ßhCG), both alone and in combination, as biomarkers for miscarriage throughout the first trimester. DESIGN: Prospective, nested case-control study. SETTING: Tertiary Centre, Queen Charlotte Hospital, London, United Kingdom. PATIENT(S): Adult women who had miscarriages (n = 95, 173 samples) and women with healthy pregnancies (n = 265, 557 samples). INTERVENTION(S): The participants underwent serial ultrasound scans and blood sampling for measurement of plasma kisspeptin and ßhCG levels during the first trimester. MAIN OUTCOME MEASURE(S): The ability of plasma kisspeptin and ßhCG levels to distinguish pregnancies complicated by miscarriage from healthy pregnancies unaffected by miscarriage. RESULT(S): Gestation-adjusted levels of circulating kisspeptin and ßhCG were lower in samples from women with miscarriages than in women with healthy pregnancies by 79% and 70%, respectively. The area under the receiver-operating characteristic curve for identifying miscarriage during the first trimester was 0.874 (95% confidence interval [CI] 0.844-0.904) for kisspeptin, 0.859 (95% CI 0.820-0.899) for ßhCG, and 0.916 (95% CI 0.886-0.946) for the sum of the two markers. The performance of kisspeptin in identifying miscarriage improved with increasing length of gestation, whereas that of ßhCG worsened. A decision matrix incorporating kisspeptin, ßhCG, and gestational age had 83% to 87% accuracy for the prediction of miscarriage. CONCLUSION(S): Plasma kisspeptin is a promising biomarker for miscarriage and provides additional value to ßhCG alone, especially during later gestational weeks of the first trimester.


Asunto(s)
Aborto Espontáneo/sangre , Kisspeptinas/sangre , Primer Trimestre del Embarazo/sangre , Aborto Espontáneo/diagnóstico por imagen , Aborto Espontáneo/etiología , Biomarcadores/sangre , Estudios de Casos y Controles , Gonadotropina Coriónica Humana de Subunidad beta/sangre , Regulación hacia Abajo , Femenino , Edad Gestacional , Humanos , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Ultrasonografía Prenatal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA