Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Strength Cond Res ; 24(2): 517-21, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20072046

RESUMEN

The Lift-and-Raise hamstring flexibility test was developed as a field-based assessment to eliminate the effects of individual and developmental differences in arm, leg, and trunk lengths found with the commonly used Sit-and-Reach tests. This study assessed the initial reliability of the prototype instrument and its validity by comparing obtained values from a Cybex Testing and Rehabilitation System. Flexibility of the left leg was assessed on 53 college-aged participants (women, n = 28; men, n = 25) using the Lift-and-Raise test by 2 independent testers to determine initial reliability measures. The Cybex Testing and Rehabilitation System was compared with the Lift-and-Raise test when assessing the left hamstring of 39 college-aged students (women, n = 23; men, n = 16) to establish initial validity. A high intraclass correlation coefficient emerged between the 2 testers (r = 0.944) on the Lift-and-Raise instrument and between the Lift-and-Raise test and the Cybex testing protocol (r = 0.891). Based on initial results, the Lift-and-Raise test seems to be a reliable and valid test to measure hamstring flexibility.


Asunto(s)
Prueba de Esfuerzo/métodos , Pierna/fisiología , Contracción Muscular/fisiología , Músculo Esquelético/fisiología , Análisis de Varianza , Femenino , Humanos , Masculino , Docilidad , Reproducibilidad de los Resultados , Adulto Joven
2.
J Strength Cond Res ; 22(1): 310-7, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18296991

RESUMEN

This study assessed the mechanical reliability and validity of the INRTEK iSAM 9000 isokinetic dynamometer, and compared the obtained torque values of the prototype device with those from a traditional device. Sixty volunteers (40 men and 20 women) were tested at 60 degrees per second for shoulder, knee, and trunk flexion, and extension on both the Cybex 6000 and a new isokinetic dynamometer (iSAM 9000). Intraclass correlation coefficients (ICC) and standard errors of measurement (SEM) revealed a high level of reproducibility and precision in the device's torque measurements (ICC range = 0.94-0.98; SEM range = 5.2-29.7). Pearson r values revealed very high relationships between the two instruments (set 1: r = 0.84-0.93; set 2: r = 0.87-0.93; P < 0.05). Significantly higher peak torque for both sets of left and right knee flexion and extension, right shoulder extension and trunk extension was found for the iSAM 9000 compared to the Cybex 6000 (P < 0.05). The strong ICCs and small SEMs support the device's mechanical reliability and validity. The high correlation coefficients between the prototype dynamometer and the Cybex 6000 support the new device's validity in the measurement of isokinetic torque. The findings of this study will be used to refine the next generation of the INRTEK isokinetic device with respect to test protocols and the reliability of measuring human muscle performance.


Asunto(s)
Prueba de Esfuerzo/instrumentación , Dinamómetro de Fuerza Muscular , Fuerza Muscular/fisiología , Músculo Esquelético/fisiología , Esfuerzo Físico/fisiología , Adulto , Antropometría , Estudios de Cohortes , Diseño de Equipo , Seguridad de Equipos , Ejercicio Físico , Femenino , Humanos , Extremidad Inferior , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular/fisiología , Reproducibilidad de los Resultados , Torque , Extremidad Superior
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...