Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Chromatogr A ; 1724: 464924, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38653038

RESUMEN

This work, reports the successful preparation a thin film by a simple and inexpensive process for quantification of a model analytes in the urine sample using HPLC-UV. To this end, cellulose paper was employed as a substrate for the in-situ synthesis of MOF-5, to increase the resistance of the prepared film. The prepared film can be reused 26 times with no reduction in its performance. The thin film prepared by MOF-5 modified cellulose substrate was utilized in thin film microextraction (TFME) method for the extraction and preconcentration of naproxen, aspirin, tolmetin, and celecoxib. Under optimal conditions, the linear dynamic range of the target analytes was 2-500 µg L-1 with correlation coefficients (R2) ranging from 0.9961 to 0.9990. Also, the limits of detection (LODs), the limits of quantification (LOQs) and relative standard deviation (RSD%) of the proposed method for selected analytes ranged between 0.57 and 0.77 µg L-1, 1.7 to 2.3 and 3.5 % to 6.2 %, respectively. Moreover, relative recoveries varied from of 94 % to 108 %, indicating the absence of matrices effect in the proposed method. Eventually, the TFME was successfully used for the extraction of selected analytes from urine samples.


Asunto(s)
Antiinflamatorios no Esteroideos , Celulosa , Límite de Detección , Estructuras Metalorgánicas , Microextracción en Fase Sólida , Cromatografía Líquida de Alta Presión/métodos , Celulosa/química , Estructuras Metalorgánicas/química , Humanos , Antiinflamatorios no Esteroideos/orina , Antiinflamatorios no Esteroideos/análisis , Antiinflamatorios no Esteroideos/aislamiento & purificación , Microextracción en Fase Sólida/métodos , Reproducibilidad de los Resultados
2.
Food Chem X ; 19: 100857, 2023 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-37780334

RESUMEN

The present research is the first report on the application of Keggin-type phosphotungstic acid/polyvinylidene fluoride membrane. This compound as a simple, cost-effective and novel sorbent was used for the extraction and pre-concentration of two organophosphorus pesticides in real samples in the thin film solid-phase microextraction (TFME) method. TFME as one of the sub-branches of solid phase microextraction resolves the problems of SPME methods, including their limited absorption capacity. These extraction methods have a high surface-to-volume ratio, which improves their sensitivity compared to other geometries. Under optimal conditions, the limit of detections (LODs), the limit of quantifications (LOQs), and relative standard deviation (RSD) of this method varied in the ranges of 0.29-0.31 µg L-1, 0.96-1.0 µg L-1, and 3.9%-6.2%, respectively. This method showed a linear dynamic range (LDR) of 1.0-500 µg L-1 with a coefficient of determination (r2) above 0.9978. This promising method was used to analyze malathion and diazinon.

3.
J Chromatogr A ; 1697: 463993, 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37084695

RESUMEN

Herein, a copper-chromium-layered double hydroxide (Cu/Cr-LDH) was synthesized by the co-precipitation method. The Cu/Cr-LDH was intercalated to the Keggin-type polyoxometalate (H3PW12O40). The modified LDH accommodated in the pores of hollow fiber (HF), to prepare the extracting device for the HF-solid phase microextraction method (HF-SPME). The method was used for the extraction of 4-chlorophenol, 2,4-dichlorophenol, and 2,4,6- trichlorophenol from tap water, river water, and tea sample. The extracted target analytes were quantified via high-performance liquid chromatography-UV detection. The figures of merit of the method such as, linear dynamic ranges (LDRs), limit of detections (LODs) and, limit of quantifications (LOQs), were determined based on the obtained optimum condition. Based on the results, the LDR was between 1 and 500 µg L - 1 and r2 higher than 0.9960. The LODs and LOQs were obtained in the ranges of 0.28-0.36 µg L - 1 and 0.92-1.1 µg L - 1, respectively. The relative standard deviations ((RSDs% for inter-and intra-day) of the method for the extraction of target analytes were calculated in two different concentrations of (2 and 10 µg L - 1) and (5 and 10 µg L - 1) between 3.70% - 5.30% and 3.50% - 5.70%-respectively. The enrichment factors were obtained between 57 and 61. In order to investigate the accuracy of the method, also the relative recovery was obtained, between 93 and 105%. Finally, the proposed method was used for the extraction of the selected analytes in different water and tea samples.


Asunto(s)
Clorofenoles , Microextracción en Fase Líquida , Cromatografía Líquida de Alta Presión/métodos , Microextracción en Fase Sólida/métodos , Ácido Fosfotúngstico/análisis , Cobre/análisis , Porosidad , Agua/química , Clorofenoles/análisis , , Microextracción en Fase Líquida/métodos
4.
J Chromatogr A ; 1641: 461984, 2021 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-33611121

RESUMEN

The in-situ synthesis and application of nanocubic Co3O4-coated graphene oxide (Co3O4@ GO) was introduced for the first time to present a cost-effective, stable and convenient operation and a simple device for hollow fiber solid-phase microextraction (HF-SPME) of four selected nonsteroidal anti-inflammatory drugs (NSAIDs) including diclofenac, mefenamic acid, ibuprofen and indomethacin. The extracted analytes were desorbed by an appropriate organic solvent and analyzed via high-performance liquid chromatography-ultraviolet detection (HPLC-UV). The prepared sorbent was approved using different characterization methods such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The variables effective on the Co3O4@GO-HF-SPME method including extraction time, desorption time, desorption solvent volume, sample pH, stirring rate and ionic strength were screened via Plackett-Burman design and then optimized by Box-Behnken design. Under optimal condition, the calibration curves were linear within the range of 1.0-200.0 µg L-1 of analyte concentration with detection limits of 0.18-1.1 µg L-1 and the relative standard deviations less than 10.1%. The limits of quantification (LOQs) were in the range of 0.60-3.67 µg L-1. Matrix effect was not observed with this method; therefore, standard addition is not necessary for quantification of target compounds. The enrichment factors were obtained in the range of 49-68. The relative recoveries of the urine sample analysis were calculated in the range of 93-102%. Finally, the presented method exhibited good sensitivity, excellent repeatability, high reusability and acceptable precision, which will be a promising method to analyze various nonsteroidal anti-inflammatory drugs in urine samples.


Asunto(s)
Antiinflamatorios no Esteroideos/orina , Cobalto/química , Grafito/química , Nanocompuestos/química , Óxidos/química , Microextracción en Fase Sólida/métodos , Rayos Ultravioleta , Adulto , Cromatografía Líquida de Alta Presión , Diclofenaco/orina , Femenino , Humanos , Ibuprofeno/orina , Límite de Detección , Masculino , Ácido Mefenámico/orina
5.
Anal Chim Acta ; 1140: 99-110, 2020 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-33218494

RESUMEN

An effective, sensitive, relatively-fast and cost-effective method was developed to determine two types of selected organophosphorus pesticides (OPPs) including diazinon and chlorpyrifos in tomato, cucumber and agricultural water samples through applying MIL-101@ graphene oxide-reinforced hollow fiber solid-phase microextraction (MIL-101@GO-HF-SPME). The extracted analytes were desorbed via organic solvent and analyzed through high-performance liquid chromatography-ultraviolet detection (HPLC-UV) after extraction. MIL-101@ GO sorbent which was previously prepared and characterized was first dispersed in methanol by ultrasonication and then immobilized into the pores of a hollow fiber (HF). Several factors involved in MIL-101@GO-HF-SPME experiment such as desorption volume, ionic strength, desorption time, sample pH, extraction time and stirring rate were screened via Plackett-Burman design and then optimized through Box-Behnken design with the purpose of reaching the highest extraction efficiency. The above method showed a good linear range (1-500 µg L-1) with coefficient of determination higher than 0.9948, low limits of determination (LODs, 0.21 and 0.27 µg L-1), acceptable limits of quantifications (LOQs, 0.72 and 0.91 µg L-1), good enrichment factors (EFs, 49 and 41), acceptable absolute recoveries (AR%, 49 and 41%) and good spiking recoveries (88-104%) under the optimized condition at three different spiked levels for chlorpyrifos and diazinon, respectively. It is worth mentioning that due to the clean-up function of HF, there is no time-consuming sample pretreatment procedure (e.g. filtration or centrifugation) prior to the microextraction. Therefore, the presented method took advantage of both excellent adsorption performance of MIL-101@GO and the clean-up function of HF. The results confirmed that the presented method would be promising for the analysis of various types of these pesticides in environmental and vegetable samples.


Asunto(s)
Cloropirifos , Cucumis sativus , Microextracción en Fase Líquida , Solanum lycopersicum , Cromatografía Líquida de Alta Presión , Diazinón , Grafito , Límite de Detección , Estructuras Metalorgánicas , Microextracción en Fase Sólida , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA