Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cureus ; 14(8): e28003, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36134101

RESUMEN

Background The ECG diagnosis of left ventricular hypertrophy (LVH) has been challenging for over a hundred years. ECG diagnosis of LVH has shown good specificity but lacks sensitivity. In addition, voltage-based criteria can be affected by multiple conditions such as obesity and chronic lung disease. Therefore, we sought to compare Romhilt-Estes (R-E) criteria with commonly used voltage-based criteria in presumptive ECG diagnosis of LVH.  Methods This is a retrospective electronic medical record study from September 1, 2017, to September 1, 2018, of 499 consecutive ECGs from Boca Raton Regional Hospital. Different ECG criteria were used to identify the presence of LVH, including the Cornell criteria, modified Cornell criteria, Sokolow-Lyon criteria, and Romhilt-Estes criteria. The main study outcome was to compare the R-E criteria in presumptive ECG diagnosis of LVH to the voltage-based criteria (Cornell, modified Cornell, and Sokolow-Lyon).  Results After analyzing the ECGs using the different ECG criteria, R-E criteria were positive with LVH present (score ≥ 5 points) in 162 patients. In contrast, Cornell criteria were positive in 42 patients (8.4%), modified Cornell criteria in 50 patients (10%), and Sokolow-Lyon criteria in 13 patients (2.6%). In addition, R-E criteria showed higher positivity of LVH diagnosis compared to the sum of three voltage-based criteria (32.7% versus 21% respectively, p<0.001). Conclusion We presume that R-E criteria can help better diagnose LVH by ECG compared to other commonly-used voltage-based criteria. However, further studies are needed using confirmatory imaging to confirm the accuracy of R-E criteria and compare it with other voltage based-criteria.

2.
J Cardiothorac Surg ; 16(1): 234, 2021 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-34399802

RESUMEN

Prosthetic valve endocarditis after transcatheter aortic valve implantation (TAVI) is a rare complication associated with a high mortality rate. Nonetheless, the rapid expansion of TAVI in recent years has proportionally increased the number of patients exposed to the risk of developing transcatheter valve infection. A 71-year-old female with recent history of TAVI was diagnosed with prosthetic valve obstruction secondary to endocarditis. The characteristics of clinical presentation of endocarditis in the balloon-expandable transcatheter valve and the intra-operative findings are discussed with a review of the literature and tips of management.


Asunto(s)
Válvula Aórtica , Endocarditis Bacteriana , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Estreptococos Viridans/aislamiento & purificación , Anciano , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/microbiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/microbiología , Estenosis de la Válvula Aórtica/terapia , Bovinos , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/terapia , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/microbiología , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/terapia , Factores de Riesgo , Infecciones Estreptocócicas/diagnóstico , Infecciones Estreptocócicas/microbiología , Infecciones Estreptocócicas/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
3.
Eur Heart J Case Rep ; 5(5): ytab137, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34124562

RESUMEN

BACKGROUND: Coronary flow compromise is a significant risk of transcatheter aortic valve therapy. Warranting preservation of coronary flow is even more challenging with transcatheter aortic valve re-intervention since the implantation of a transcatheter valve within a degenerated bioprosthetic or transcatheter valve increases significantly this hazard. CASE SUMMARY: We present a case of heart failure secondary to transcatheter aortic valve degeneration requiring a transcatheter aortic valve re-intervention. Pre-operative imaging studies demonstrated a high risk for iatrogenic coronary flow impairment. The patient underwent a successful surgical removal of the prosthetic valve leaflets followed by direct transcatheter aortic valve implantation. CONCLUSION: We reviewed the literature on the approach to difficult coronaries in transcatheter aortic valve therapy, and we describe an innovative hybrid approach that may represent a viable alternative in cases where catheter techniques of coronary flow preservation are not applicable.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA