Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Eng Sci Med ; 45(4): 1335-1340, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36227496

RESUMEN

This work details the clinical pilot study methodology used at Wellington Blood and Cancer Centre (WBCC) before the clinical release of in vivo dosimetry (IVD) system EPIgray™ for head and neck (H&N) volumetric modulated arc therapy (VMAT) treatments. Clinical pilot studies make it possible to select appropriate, department-specific tolerance ranges for the treatment type and site under investigation. An IVD clinical pilot study of H&N VMAT treatments was conducted over 3 months at WBCC using EPIgray™ dose reconstruction software and included 12 patients and 32 individual treatment fractions. Statistical analysis of the dose deviations between the treatment planning system (TPS) dose and EPIgray™ reconstructed dose confirmed that a deviation tolerance range of ± 7.0% was an appropriate choice for H&N VMAT at WBCC.


Asunto(s)
Dosimetría in Vivo , Neoplasias , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Proyectos Piloto , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
2.
Med Phys ; 42(4): 1625-39, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25832053

RESUMEN

PURPOSE: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. METHODS: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. RESULTS: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was -2.1% ± 2.2% (1 SD), -1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about -2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. CONCLUSIONS: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.


Asunto(s)
Radiometría/instrumentación , Radiometría/métodos , Radioterapia de Intensidad Modulada/métodos , Estudios de Factibilidad , Humanos , Neoplasias/radioterapia , Aceleradores de Partículas , Reconocimiento de Normas Patrones Automatizadas/métodos , Fantasmas de Imagen , Fotones/uso terapéutico , Poliestirenos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/instrumentación , Programas Informáticos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA