Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(7)2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38610388

RESUMEN

An original approach has been proposed for designing a nanofibrous (NF) layer using UV-cured polyvinylpyrrolidone (PVP) as a matrix, incorporating mesoporous graphene carbon (MGC) nanopowder both inside and outside the fibers, creating a sandwich-like structure. This architecture is intended to selectively adsorb and detect acetic acid vapors, which are known to cause health issues in exposed workers. The nanocomposite MGC-PVP-NFs layer was fabricated through electrospinning deposition onto interdigitated microelectrodes (IDEs) and stabilized under UV-light irradiation. To enhance the adhesion of MGC onto the surface of the nanocomposite polymeric fibers, the layer was dipped in a suspension of polyethyleneimine (PEI) and MGC. The resulting structure demonstrated promising electrical and sensing properties, including rapid responses, high sensitivity, good linearity, reversibility, repeatability, and selectivity towards acetic acid vapors. Initial testing was conducted in a laboratory using a bench electrometer, followed by validation in a portable sensing device based on consumer electronic components (by ARDUINO®). This portable system was designed to provide a compact, cost-effective solution with high sensing capabilities. Under room temperature and ambient air conditions, both laboratory and portable tests exhibited favorable linear responses, with detection limits of 0.16 and 1 ppm, respectively.

2.
Sensors (Basel) ; 20(21)2020 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-33113994

RESUMEN

Passive air samplers (PASs) have been used for mapping gaseous mercury concentration in extensive areas. In this work, an easy-to-use and -prepare gold nanoparticle (NP)-based PAS has been investigated. The PAS is constituted of a microfibrous quartz disk filter impregnated of gold NP photo-growth on TiO2 NPs (Au@TiO2) and used as gaseous mercury adsorbing material. The disk was housed in a cylinder glass container and subjected to an axial diffusive sampling. The adsorbed mercury was measured by thermal desorption using a Tekran® instrument. Different amounts of Au@TiO2 (ranging between 4.0 and 4.0 × 10-3 mg) were deposited by drop-casting onto the fibrous substrate and assessed for about 1 year of deployment in outdoor environment with a mercury concentration mean of about 1.24 ± 0.32 ng/m3 in order to optimize the adsorbing layer. PASs showed a linear relation of the adsorbed mercury as a function of time with a rate of 18.5 ± 0.4 pg/day (≈1.5% of the gaseous concentration per day). However, only the PAS with 4 mg of Au@TiO2, provided with a surface density of about 3.26 × 10-2 mg/mm2 and 50 µm thick inside the fibrous quartz, kept stability in working, with a constant sampling rate (SR) (0.0138 ± 0.0005 m3/day) over an outdoor monitoring experimental campaign of about 1 year. On the other hand, higher sampling rates have been found when PASs were deployed for a few days, making these tools also effective for one-day monitoring. Furthermore, these PASs were used and re-used after each thermal desorption to confirm the chance to reuse such structured layers within their samplers, thus supporting the purpose to design inexpensive, compact and portable air pollutant sampling devices, ideal for assessing both personal and environmental exposures. During the whole deployment, PASs were aided by simultaneous Tekran® measurements.

3.
Nanomaterials (Basel) ; 9(2)2019 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-30781545

RESUMEN

Structural and functional properties of polymer composites based on carbon nanomaterials are so attractive that they have become a big challenge in chemical sensors investigation. In the present study, a thin nanofibrous layer, comprising two insulating polymers (polystyrene (PS) and polyhydroxibutyrate (PHB)), a known percentage of nanofillers of mesoporous graphitized carbon (MGC) and a free-base tetraphenylporphyrin, was deposited onto an Interdigitated Electrode (IDE) by electrospinning technology. The potentials of the working temperature to drive both the sensitivity and the selectivity of the chemical sensor were studied and described. The effects of the porphyrin combination with the composite graphene⁻polymer system appeared evident when nanofibrous layers, with and without porphyrin, were compared for their morphology and electrical and sensing parameters. Porphyrin fibers appeared smoother and thinner and were more resistive at lower temperature, but became much more conductive when temperature increased to 60⁻70 °C. Both adsorption and diffusion of chemicals seemed ruled by porphyrin according its combination inside the composite fiber, since the response rates dramatically increased (toluene and acetic acid). Finally, the opposite effect of the working temperature on the sensitivity of the porphyrin-doped fibers (i.e., increasing) and the porphyrin-free fibers (i.e., decreasing) seemed further confirmation of the key role of such a macromolecule in the VOC (volatile organic compound) adsorption.

4.
Nanomaterials (Basel) ; 8(10)2018 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-30301278

RESUMEN

Passive sampling systems (PASs) are a low cost strategy to quantify Hg levels in air over both different environmental locations and time periods of few hours to weeks/months. For this reason, novel nanostructured materials have been designed and developed. They consist of an adsorbent layer made of titania nanoparticles (TiO2NPs, ≤25 nm diameter) finely decorated with gold nanoparticles. The TiO2NPs functionalization occurred for the photocatalytic properties of titania-anatase when UV-irradiated in an aqueous solution containing HAuCl4. The resulting nanostructured suspension was deposited by drop-casting on a thin quartz slices, dried and then incorporated into a common axial sampler to be investigated as a potential PAS device. The morphological characteristics of the sample were studied by High-Resolution Transmission Electron Microscopy, Atomic Force Microscopy, and Optical Microscopy. UV-Vis spectra showed a blue shift of the membrane when exposed to Hg° vapors. The adsorbed mercury was thermally desorbed for a few minutes, and then quantified by a mercury vapor analyzer. Such a sampling system reported an efficiency of adsorption that was equal to ≈95%. Temperature and relative humidity only mildly affected the membrane performances. These structures seem to be promising candidates for mercury samplers, due to both the strong affinity of gold with Hg, and the wide adsorbing surface.

5.
Front Chem ; 6: 432, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30320064

RESUMEN

The potentials to use the working temperature to tune both the sensitivity and the selectivity of a chemical sensor based on a nanostructured and nanocomposite polymer layer have been investigated and described. Thus, in a single step, a peculiar chemical layer was grown up onto IDE (Interdigitated Electrode) microtransducers by electrospinning deposition and using a single-needle strategy. The 3-component nanofibers, obtained from a mixture of polystyrene and polyhydroxibutyrate (insulating thermoplastics) and a known concentration of mesoporous graphitized carbon nanopowder, appeared highly rough on the surface and decorated with jagged islands but homogeneous in shape and diameter, with the nanofillers aggregated into clusters more or less densely packed through the fibers. The resulting sensor was conductive at room temperature and could work between 40 and 80°C without any apparent degradation. As the fibrous sensing layer was heated, the current increased and the sensitivity to some classes of VOCs such as an oxidizing gas drastically changed depending on the working temperature. More in detail, the sensor resulted highly sensitive and selective to acetic acid at 40°C but the sensitivity fell down, decreasing by 96%, when the sensor operated at 80°C. On the other hand, although an increase in temperature caused a general decrease in sensitivity to the tested VOCs (with a maximum of 14, 81, and 78% for amine, acetone and toluene, respectively) and water vapors (with a maximum of 55%), higher temperature affected only slightly the amine permeation, thus modifying the partial selectivity of the sensor to these chemicals. Conversely, when the operating temperature increased, the sensitivity to the detected gas, NO2, increased too, reporting a ~2 ppb limit of detection (LOD), thus confirming that the temperature was able to drive the selectivity of nanocomposite polymeric sensors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...