Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neurocirugia (Astur : Engl Ed) ; 33(2): 71-81, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35248301

RESUMEN

BACKGROUND: Spinal instrumentation using transpedicular screws has been used for decades to stabilize the spine. In October 2018, an intraoperative CT system was acquired in the Neurosurgery service of the University Hospital Complex of Vigo, this being the first model of these characteristics in the Spanish Public Health System, so we began a study from January 2015 to December 2019 to assess the precision of the transpedicular screws implanted with this system compared with a control group performed with the classical technique and final fluoroscopic control. METHODS: The study was carried out in patients who required transpedicular instrumentation surgery, in total 655 screws were placed, 339 using the free-hand technique (Group A) and 316 assisted with intraoperative CT navigation (Group B) (p>0.05). Demographic characteristics, related to surgery and the screw implantation grades were assessed using the Gertzbein-Robbins classification. RESULTS: 92 patients were evaluated, between 12 and 86 years (average: 57.1 years). 161 thoracic screws (24.6%) and 494 lumbo-sacral screws (75.4%) were implanted. Of the thoracic screws, 33 produced a pedicle rupture. For the lumbo-sacral screws, 71 have had pedicle violation. The overall correct positioning rate for the free-hand group was 72.6% and for the CT group it was 96.5% (p<0.05). CONCLUSION: The accuracy rate is higher in thoracic-lumbar instrumentation in the navigation group versus free-hand group with fluoroscopic control.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Fluoroscopía/métodos , Humanos , Procedimientos Neuroquirúrgicos , Fusión Vertebral/métodos , Tomografía Computarizada por Rayos X/métodos
2.
Artículo en Inglés, Español | MEDLINE | ID: mdl-33663907

RESUMEN

BACKGROUND: Spinal instrumentation using transpedicular screws has been used for decades to stabilize the spine. In October 2018, an intraoperative CT system was acquired in the Neurosurgery service of the University Hospital Complex of Vigo, this being the first model of these characteristics in the Spanish Public Health System, so we began a study from January 2015 to December 2019 to assess the precision of the transpedicular screws implanted with this system compared with a control group performed with the classical technique and final fluoroscopic control. METHODS: The study was carried out in patients who required transpedicular instrumentation surgery, in total 655 screws were placed, 339 using the free-hand technique (Group A) and 316 assisted with intraoperative CT navigation (Group B) (p>0.05). Demographic characteristics, related to surgery and the screw implantation grades were assessed using the Gertzbein-Robbins classification. RESULTS: 92 patients were evaluated, between 12 and 86 years (average: 57.1 years). 161 thoracic screws (24.6%) and 494 lumbo-sacral screws (75.4%) were implanted. Of the thoracic screws, 33 produced a pedicle rupture. For the lumbo-sacral screws, 71 have had pedicle violation. The overall correct positioning rate for the free-hand group was 72.6% and for the CT group it was 96.5% (p<0.05). CONCLUSION: The accuracy rate is higher in thoracic-lumbar instrumentation in the navigation group versus free-hand group with fluoroscopic control.

3.
Neurocirugia (Astur : Engl Ed) ; 30(5): 207-214, 2019.
Artículo en Inglés, Español | MEDLINE | ID: mdl-31155281

RESUMEN

INTRODUCTION AND OBJECTIVES: The anterior communicating complex is one the most common locations for aneurysm development. It receives blood from both carotid circulations and the effect of synchrony on the arrival of blood flow has not been previously studied. The objective of this study was to compare the asynchrony conditions of the A1 pulse and its effects on the haemodynamic conditions of anterior communicating artery (ACoA) aneurysms. MATERIALS AND METHODS: From 2008 to 2017, 54 anterior communicating artery aneurysms treated at our centre were included in the study. Computational fluid dynamics (CFD) techniques were employed and simulations consisted of complete conditions of synchrony and introducing a delay of 0.2s in the non-dominant A1 artery. Time-averaged wall shear stress (TAWSS), low shear area (LSA), A1 diameter and ACoA angles were measured. RESULTS: The difference in the LSA in conditions of synchrony and asynchrony resulted in a broad range of positive and negative values. The symmetry index (p=0.04) and A1/A2 angle on the dominant artery (p=0.04) were associated with changes in LSA. CONCLUSIONS: In asynchrony, LSA increased in the absence of A1 asymmetry and low A1/A2 angles, potentially increasing the risk of aneurysm rupture in this location.


Asunto(s)
Aneurisma Roto/fisiopatología , Arteria Cerebral Anterior/fisiopatología , Hidrodinámica , Aneurisma Intracraneal/fisiopatología , Pulso Arterial , Adulto , Anciano , Aneurisma Roto/complicaciones , Velocidad del Flujo Sanguíneo , Angiografía por Tomografía Computarizada , Simulación por Computador , Femenino , Hemorreología , Humanos , Aneurisma Intracraneal/complicaciones , Masculino , Persona de Mediana Edad , Flujo Pulsátil , Factores de Riesgo , Hemorragia Subaracnoidea/etiología
4.
World Neurosurg ; 103: 291-302, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28435119

RESUMEN

BACKGROUND: Linear accelerator stereotactic radiosurgery is one of the modalities available for the treatment of central nervous system arteriovenous malformations (AVMs). The aim of this study was to describe our 15-year experience with this technique in a single tertiary center and the analysis of outcome-related factors. METHODS: From 1998 to 2013, 195 patients were treated with linear accelerator-based radiosurgery; we conducted a retrospective study collecting patient- and AVM-related variables. Treatment outcomes were obliteration, posttreatment hemorrhage, symptomatic radiation-induced changes, and 3-year neurologic status. We also analyzed prognostic factors of each outcome and predictability analysis of 5 scales: Spetzler-Martin grade, Lawton-Young supplementary and Lawton combined scores, radiosurgery-based AVM score, Virginia Radiosurgery AVM Scale, and Heidelberg score. RESULTS: Overall obliteration rate was 81%. Nidus diameter and venous drainage were predictive of obliteration (P < 0.05), ruptured status and previous embolization were not related to rate of obliteration, and low-grade AVMs had higher obliteration rates. Posttreatment hemorrhage incidence was 8.72%; nidus diameter was the only predictor (P = 0.05). Symptomatic radiation-induced changes occurred in 11.79% of patients and were significantly associated with unruptured status (P < 0.05). Treatment success as a composite measure was obtained in 70.77% of patients. Receiver operating characteristic curves were presented for each scoring system and outcome measure; best area under the curve was 0.687 for Lawton combined score in the obliteration outcome. CONCLUSIONS: In the long-term, linear accelerator-based radiosurgery is a useful, valid, effective, and safe modality for treatment of brain AVMs.


Asunto(s)
Hemorragia Cerebral/epidemiología , Malformaciones Arteriovenosas Intracraneales/radioterapia , Radiocirugia , Adulto , Angiografía de Substracción Digital , Angiografía Cerebral , Embolización Terapéutica , Femenino , Humanos , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Rotura Espontánea , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...