Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biointerphases ; 16(1): 011004, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33706519

RESUMEN

X-ray fluorescence analysis enables the study of trace element distributions in biological specimens. When this analysis is done under cryogenic conditions, cells are cryofixed as closely as possible to their natural physiological state, and the corresponding intracellular elemental densities can be analyzed. Details about the experimental setup used for analysis at the P06 beamline at Petra III, DESY and the used cryo-transfer system are described in this work. The system was applied to analyze the elemental distribution in single HeLa cells, a cell line frequently used in a wide range of biological applications. Cells adhered to silicon nitride substrates were cryoprotected within an amorphous ice matrix. Using a continuous scanning scheme and a KB x-ray focus, the distribution of elements in the cells was studied. We were able to image the intracellular potassium and zinc levels in HeLa cells as two key elements relevant for the physiology of cells.


Asunto(s)
Congelación , Espectrometría por Rayos X , Oligoelementos/análisis , Agua/química , Células HeLa , Humanos , Vacio , Rayos X
2.
Anal Chim Acta ; 1106: 22-32, 2020 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-32145852

RESUMEN

Analytical capabilities of Nanoscopic Secondary Ion Mass Spectrometry (nano-SIMS) and Synchrotron Radiation based X-ray Fluorescence (SR nano-XRF) techniques were compared for nanochemical imaging of polymorphonuclear human neutrophils (PMNs). PMNs were high pressure frozen (HPF), cryo-substituted, embedded in Spurr's resin and cut in thin sections (500 nm and 2 µm for both techniques resp.) Nano-SIMS enabled nanoscale mapping of isotopes of C, N, O, P and S, while SR based nano-XRF enabled trace level imaging of metals like Ca, Mn, Fe, Ni, Cu and Zn at a resolution of approx. 50 nm. The obtained elemental distributions were compared with those of whole, cryofrozen PMNs measured at the newly developed ID16A nano-imaging beamline at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Similarities were observed for elements more tightly bound to the cell structure such as phosphorus and sulphur, while differences for mobile ions such as chlorine and potassium were more pronounced. Due to the observed elemental redistribution of mobile ions such as potassium and chlorine, elemental analysis of high pressure frozen (HPF), cryo-substituted and imbedded cells should be interpreted critically. Although decreasing analytical sensitivity occurs due to the presence of ice, analysis of cryofrozen cells - close to their native state - remains the golden standard. In general, we found nanoscale secondary ion mass spectrometry (nano-SIMS) and synchrotron radiation based nanoscopic X-ray fluorescence (SR nano-XRF) to be two supplementary alternatives for nanochemical imaging of single cells at the nanoscale.


Asunto(s)
Neutrófilos/citología , Imagen Óptica , Análisis de la Célula Individual , Espectrometría de Masa de Ion Secundario , Sincrotrones , Humanos , Tamaño de la Partícula , Espectrometría por Rayos X , Propiedades de Superficie
3.
J Synchrotron Radiat ; 27(Pt 1): 185-198, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31868751

RESUMEN

Friedreich's ataxia (FRDA) is a neurodegenerative disease characterized by an increase in intracytoplasmic iron concentration. Here the nanoscale iron distribution within single fibroblasts from FRDA patients was investigated using synchrotron-radiation-based nanoscopic X-ray fluorescence and X-ray in-line holography at the ID16A nano-imaging beamline of the ESRF. This unique probe was deployed to uncover the iron cellular two-dimensional architecture of freeze-dried FRDA fibroblasts. An unsurpassed absolute detection capability of 180 iron atoms within a 30 nm × 50 nm nanoscopic X-ray beam footprint was obtained using state-of-the-art X-ray focusing optics and a large-solid-angle detection system. Various micrometre-sized iron-rich organelles could be revealed for the first time, tentatively identified as endoplasmic reticulum, mitochondria and lysosomes. Also a multitude of nanoscopic iron hot-spots were observed in the cytosol, interpreted as chaperoned iron within the fibroblast's labile iron pool. These observations enable new hypotheses on the storage and trafficking of iron in the cell and ultimately to a better understanding of iron-storage diseases such as Friedreich's ataxia.


Asunto(s)
Fibroblastos/química , Ataxia de Friedreich/patología , Holografía/métodos , Hierro/análisis , Análisis de la Célula Individual/métodos , Espectrometría por Rayos X/métodos , Carbono , Citoplasma/química , Fibroblastos/ultraestructura , Liofilización , Humanos , Nanoestructuras , Orgánulos/química , Orgánulos/ultraestructura , Análisis de la Célula Individual/instrumentación , Sincrotrones , Fijación del Tejido/métodos
4.
PLoS One ; 13(1): e0190495, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29342155

RESUMEN

Synchrotron radiation based nanoscopic X-ray fluorescence (SR nano-XRF) analysis can visualize trace level elemental distribution in a fully quantitative manner within single cells. However, in-air XRF analysis requires chemical fixation modifying the cell's chemical composition. Here, we describe first nanoscopic XRF analysis upon cryogenically frozen (-150°C) fibroblasts at the ID16A-NI 'Nano-imaging' end-station located at the European Synchrotron Radiation Facility (ESRF) in Grenoble (France). Fibroblast cells were obtained from skin biopsies from control and Friedreich's ataxia (FRDA) patients. FRDA is an autosomal recessive disorder with dysregulation of iron metabolism as a key feature. By means of the X-ray Fundamental Parameter (FP) method, including absorption correction of the ice layer deposited onto the fibroblasts, background-corrected mass fraction elemental maps of P, S, Cl, K, Ca, Fe and Zn of entire cryofrozen human fibroblasts were obtained. Despite the presence of diffracting microcrystals in the vitreous ice matrix and minor sample radiation damage effects, clusters of iron-rich hot-spots with similar mass fractions were found in the cytoplasm of both control and FRDA fibroblasts. Interestingly, no significant difference in the mean iron concentration was found in the cytoplasm of FRDA fibroblasts, but a significant decrease in zinc concentration. This finding might underscore metal dysregulation, beyond iron, in cells derived from FRDA patients. In conclusion, although currently having slightly increased limits of detection (LODs) compared to non-cryogenic mode, SR based nanoscopic XRF under cryogenic sample conditions largely obliterates the debate on chemical sample preservation and provides a unique tool for trace level elemental imaging in single cells close to their native state with a superior spatial resolution of 20 nm.


Asunto(s)
Ataxia de Friedreich/metabolismo , Espectrometría por Rayos X/métodos , Criopreservación , Fibroblastos/metabolismo , Ataxia de Friedreich/patología , Humanos , Límite de Detección , Nanotecnología , Estándares de Referencia
5.
Anal Chem ; 89(7): 4161-4168, 2017 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-28256828

RESUMEN

In this work, the three-dimensional elemental distribution profile within the freshwater crustacean Ceriodaphnia dubia was constructed at a spatial resolution down to 5 µm via a data fusion approach employing state-of-the-art laser ablation-inductively coupled plasma-time-of-flight mass spectrometry (LA-ICP-TOFMS) and laboratory-based absorption microcomputed tomography (µ-CT). C. dubia was exposed to elevated Cu, Ni, and Zn concentrations, chemically fixed, dehydrated, stained, and embedded, prior to µ-CT analysis. Subsequently, the sample was cut into 5 µm thin sections that were subjected to LA-ICP-TOFMS imaging. Multimodal image registration was performed to spatially align the 2D LA-ICP-TOFMS images relative to the corresponding slices of the 3D µ-CT reconstruction. Mass channels corresponding to the isotopes of a single element were merged to improve the signal-to-noise ratios within the elemental images. In order to aid the visual interpretation of the data, LA-ICP-TOFMS data were projected onto the µ-CT voxels representing tissue. Additionally, the image resolution and elemental sensitivity were compared to those obtained with synchrotron radiation based 3D confocal µ-X-ray fluorescence imaging upon a chemically fixed and air-dried C. dubia specimen.


Asunto(s)
Imagenología Tridimensional , Imagen Multimodal , Animales , Cladóceros , Cobre/análisis , Terapia por Láser , Espectrometría de Masas , Níquel/análisis , Distribución Tisular , Microtomografía por Rayos X , Zinc/análisis
6.
PLoS One ; 11(11): e0165604, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27812122

RESUMEN

High pressure frozen (HPF), cryo-substituted microtome sections of 2 µm thickness containing human neutrophils (white blood cells) were analyzed using synchrotron radiation based X-ray fluorescence (SR nano-XRF) at a spatial resolution of 50 nm. Besides neutrophils from a control culture, we also analyzed neutrophils stimulated for 1-2 h with phorbol myristate acetate (PMA), a substance inducing the formation of so-called Neutrophil Extracellular Traps (or NETs), a defense system again pathogens possibly involving proteins with metal chelating properties. In order to gain insight in metal transport during this process, precise local evaluation of elemental content was performed reaching limits of detection (LODs) of 1 ppb. Mean weight fractions within entire neutrophils, their nuclei and cytoplasms were determined for the three main elements P, S and Cl, but also for the 12 following trace elements: K, Ca, Mn, Fe, Co, Ni, Cu, Zn, Se, Br, Sr and Pb. Statistical analysis, including linear regression provided objective analysis and a measure for concentration changes. The nearly linear Ca and Cl concentration changes in neutrophils could be explained by already known phenomena such as the induction of Ca channels and the uptake of Cl under activation of NET forming neutrophils. Linear concentration changes were also found for P, S, K, Mn, Fe, Co and Se. The observed linear concentration increase for Mn could be related to scavenging of this metal from the pathogen by means of the neutrophil protein calprotectin, whereas the concentration increase of Se may be related to its antioxidant function protecting neutrophils from the reactive oxygen species they produce against pathogens. We emphasize synchrotron radiation based nanoscopic X-ray fluorescence as an enabling analytical technique to study changing (trace) element concentrations throughout cellular processes, provided accurate sample preparation and data-analysis.


Asunto(s)
Trampas Extracelulares/metabolismo , Espacio Intracelular/metabolismo , Neutrófilos/citología , Espectrometría por Rayos X/instrumentación , Sincrotrones , Calcio/metabolismo , Trampas Extracelulares/efectos de los fármacos , Humanos , Espacio Intracelular/efectos de los fármacos , Hierro/metabolismo , Acetato de Tetradecanoilforbol/farmacología , Zinc/metabolismo
7.
Anal Bioanal Chem ; 407(6): 1559-66, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25542585

RESUMEN

This study aims at evaluating the capabilities of synchrotron radiation micro X-ray fluorescence spectrometry (SR micro-XRF) for qualitative and semi-quantitative elemental mapping of the distribution of actinides in human tissues originating from individuals with documented occupational exposure. The investigated lymph node tissues were provided by the United States Transuranium and Uranium Registries (USTUR) and were analyzed following appropriate sample pre-treatment. Semi-quantitative results were obtained via calibration by external standards and demonstrated that the uranium concentration level in the detected actinide hot spots reaches more than 100 µg/g. For the plutonium hot spots, concentration levels up to 31 µg/g were found. As illustrated by this case study on these unique samples, SR micro-XRF has a high potential for this type of elemental bio-imaging owing to its high sensitivity, high spatial resolution, and non-destructive character.


Asunto(s)
Elementos de Series Actinoides/farmacocinética , Espectrometría por Rayos X/métodos , Humanos , Ganglios Linfáticos/metabolismo , Exposición Profesional , Sincrotrones , Distribución Tisular
8.
Anal Chem ; 86(23): 11826-32, 2014 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-25346101

RESUMEN

A new three-dimensional (3D) micro X-ray fluorescence (µXRF) methodology based on a novel 2D energy dispersive CCD detector has been developed and evaluated at the P06 beamline of the Petra-III storage ring (DESY) in Hamburg, Germany. This method is based on the illumination of the investigated sample cross-section by a horizontally focused beam (vertical sheet beam) while fluorescent X-rays are detected perpendicularly to the sheet beam by a 2D energy dispersive (ED) CCD detector allowing the collection of 2D cross-sectional elemental images of a certain depth within the sample, limited only by signal self-absorption effects. 3D elemental information is obtained by a linear scan of the sample in the horizontal direction across the vertically oriented sheet beam and combining the detected cross-sectional images into a 3D elemental distribution data set. Results of the 3D µXRF analysis of mineral inclusions in natural deep Earth diamonds are presented to illustrate this new methodology.

9.
Environ Sci Technol ; 48(1): 698-705, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24308862

RESUMEN

Larvae of Mytilus spp. are among the most Cu sensitive marine species. In this study we assessed the combined effect of salinity and dissolved organic carbon (DOC) on Cu accumulation on mussel larvae. Larvae were exposed for 48 h to three Cu concentrations in each of nine salinity/DOC treatments. Synchrotron radiation X-ray fluorescence was used to determine the Cu concentration in 36 individual larvae with a spatial resolution of 10 × 10 µm. Cu body burden concentrations varied between 1.1 and 27.6 µg/g DW larvae across all treatments and Cu was homogeneously distributed at this spatial resolution level. Our results indicate decreasing Cu accumulation with increasing DOC concentrations which can be explained by an increase in Cu complexation. In contrast, salinity had a nonlinear effect on Cu. This cannot be explained by copper speciation or competition processes and suggests a salinity-induced alteration in physiology.


Asunto(s)
Cobre/farmacocinética , Mytilus/metabolismo , Contaminantes Químicos del Agua/farmacocinética , Animales , Organismos Acuáticos , Carbono/análisis , Embrión no Mamífero/efectos de los fármacos , Larva/efectos de los fármacos , Larva/metabolismo , Mytilus/efectos de los fármacos , Mytilus/embriología , Salinidad , Espectrometría por Rayos X/métodos , Sincrotrones
10.
Anal Chim Acta ; 664(1): 19-26, 2010 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-20226927

RESUMEN

Visualization of elemental distributions in thin sections of biological tissue is gaining importance in many disciplines of biological and medical research. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and scanning micro-X-ray fluorescence spectrometry (micro-XRF) are two widely used microanalytical techniques for elemental mapping. This article compares the capabilities of the two techniques for imaging the distribution of selected elements in the model organism Daphnia magna in terms of detection power and spatial resolution. Sections with a thickness of 10 and 20 microm of the fresh water crustacean Daphnia magna were subjected to LA-ICP-MS and micro-XRF analysis. The elemental distributions obtained for Ca, P, S and Zn allow element-to-tissue correlation. LA-ICP-MS and micro-XRF offer similar limits of detection for the elements Ca and P and thus, allow a cross-validation of the imaging results. LA-ICP-MS was particularly sensitive for determining Zn (LOD 20 microg g(-1), 15 microm spot size) in Daphnia magna, while the detection power of micro-XRF was insufficient in this context. However, LA-ICP-MS was inadequate for the measurement of the S distributions, which could be better visualized with micro-XRF (LOD 160 microg g(-1), 5 s live time). Both techniques are thus complementary in providing an exhaustive chemical profiling of tissue samples.


Asunto(s)
Daphnia/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría por Rayos X/métodos , Animales , Calcio/análisis , Rayos Láser , Fósforo/análisis , Zinc/análisis
11.
Environ Sci Technol ; 43(12): 4537-46, 2009 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-19603674

RESUMEN

Cerium dioxide nanoparticles (CeO2 NPs) are increasingly being used as a catalyst in the automotive industry. Consequently, increasing amounts of CeO2 NPs are expected to enter the environment where their fate in and potential impacts are unknown. In this paper we describe the fate and effects of CeO2 NPs of three different sizes (14, 20, and 29 nm) in aquatic toxicity tests. In each standard test medium (pH 7.4) the CeO2 nanoparticles aggregated (mean aggregate size approximately 400 nm). Four test organisms covering three different trophic levels were investigated, i.e., the unicellular green alga Pseudokirchneriella subcapitata, two crustaceans: Daphnia magna and Thamnocephalus platyurus, and embryos of Danio rerio. No acute toxicity was observed for the two crustaceans and D. rerio embryos, up to test concentrations of 1000, 5000, and 200 mg/L, respectively. In contrast, significant chronic toxicity to P. subcapitata with 10% effect concentrations (EC10s) between 2.6 and 5.4 mg/L was observed. Food shortage resulted in chronic toxicity to D. magna, for wich EC10s of > or = 8.8 and < or = 20.0 mg/L were established. Chronic toxicity was found to increase with decreasing nominal particle diameter and the difference in toxicity could be explained by the difference in surface area. Using the data set, PNEC(aquatic)S > or = 0.052 and < or = 0.108 mg/L were derived. Further experiments were performed to explain the observed toxicity to the most sensitive organism, i.e., P. subcapitata. Toxicity could not be related to a direct effect of dissolved Ce or CeO2 NP uptake or adsorption, nor to an indirect effect of nutrient depletion (by sorption to NPs) or physical light restriction (through shading by the NPs). However, observed clustering of NPs around algal cells may locally cause a direct or indirect effect.


Asunto(s)
Cerio/química , Nanopartículas del Metal/química , Contaminantes Químicos del Agua/química , Agua/química , Animales , Crustáceos/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Embrión no Mamífero/efectos de los fármacos , Monitoreo del Ambiente , Eucariontes/ultraestructura , Pruebas de Toxicidad , Pez Cebra/embriología
12.
Anal Bioanal Chem ; 390(7): 1717-29, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18172622

RESUMEN

A combination of inductively coupled plasma mass spectrometry (ICP-MS) and electrospray ionization mass spectrometry (ESI-MS) was deployed for the metabolite profiling and metabolite identification of a new antituberculosis compound (R207910, also known as TMC207) that is currently in drug development. R207910 contains one bromine atom, allowing the detection by ICP-MS. Fluctuations in the Br sensitivity caused by the HPLC gradient were counteracted by the use of species-unspecific isotope dilution. In order to evaluate the method developed, the results obtained were compared with those acquired via radioactivity detection. HPLC-ESI-MS was used for the structural identification of R207910 and its metabolites. The (79)Br/(81)Br isotope ratio is also valuable in the search for metabolites in the complex background of endogenous compounds obtained using HPLC-ESI-MS analyses. Data-dependent scanning using isotope recognition with an ion trap mass spectrometer or processing of Q-Tof data provides HPLC-ICP-MS-like "bromatograms". The combination of accurate mass measurements and the fragmentation behavior in the MS(2) spectra obtained using the Q-Tof Ultima mass spectrometer or MS(n) spectra acquired using the LTQ-Orbitrap allowed structural characterization of the main metabolites of R207910 in methanolic dog and rat faeces extracts taken 0-24 h post-dose.


Asunto(s)
Antituberculosos/análisis , Bromo/química , Espectrometría de Masas/métodos , Quinolinas/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Administración Oral , Animales , Antituberculosos/administración & dosificación , Antituberculosos/metabolismo , Cromatografía Líquida de Alta Presión/métodos , Diarilquinolinas , Perros , Diseño de Fármacos , Isótopos , Masculino , Estructura Molecular , Quinolinas/administración & dosificación , Quinolinas/metabolismo , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
13.
Anal Bioanal Chem ; 389(3): 777-86, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17479254

RESUMEN

In this study, a high-performance liquid chromatography (HPLC) inductively coupled plasma (ICP) mass spectrometry (MS) method was developed intended for use in metabolism studies of bromine-containing drugs, administered to test animals (or test persons). As a case study, the method was applied to a new antituberculosis compound, the bromine-containing diarylquinoline R207910. A method has been proposed to overcome the incompatibilities between the high organic solvent content (45%CH3OH and 45% CH3CN) used in the reverse-phase liquid chromatography (LC) separation on one hand and the limitations of the ICP on the other hand. Therefore, several instrument modifications had to be made. For the introduction of the column effluent, a combination of a perfluoroalkoxy LC nebulizer with a PC(3) Peltier-cooled inlet system (operated at 2 degrees C) was used. Additionally, the standard injector tube (internal diameter 2 mm) was replaced by an injector tube with an internal diameter of 1 mm and to avoid carbon build-up on the interface cones and the torch, the nebulizer gas was admixed with 6% v/v of oxygen. After optimization of the method, HPLC-ICP-MS was applied for metabolite profiling of faeces samples after dosing of (14)C-radiolabelled R207910 to dogs and rats. To evaluate the method developed, the HPLC-ICP-MS results were compared with those of HPLC with UV spectrophotometric and (14)C radiochemical detection. As the HPLC-ICP-MS method gave rise to a higher selectivity than HPLC with UV detection and to a better detection limit (5 ng R207910) than the method with radiochemical detection (65 ng R207910), it can be concluded that ICP-MS can be used as a good alternative to the more traditional detection methods, even when a mobile phase with high organic solvent content has to be used in the LC separation.


Asunto(s)
Antituberculosos/análisis , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/métodos , Preparaciones Farmacéuticas/análisis , Animales , Radioisótopos de Carbono , Cromatografía Líquida de Alta Presión/instrumentación , Diarilquinolinas , Perros , Estabilidad de Medicamentos , Humanos , Espectrometría de Masas/instrumentación , Compuestos Orgánicos/química , Quinolinas/análisis , Ratas , Solventes/química , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...