Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
J Neurosurg Case Lessons ; 7(15)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38588592

RESUMEN

BACKGROUND: Robot-assisted sacroiliac joint (SIJ) fusion has gained popularity, but it carries the risk of complications such as injury to the superior gluteal artery (SGA). The authors present the case of an awake percutaneous robot-assisted SIJ fusion leading to an SGA pseudoaneurysm. OBSERVATIONS: An 80-year-old male, who had undergone an awake percutaneous robot-assisted SIJ fusion, experienced postoperative left hip pain and bruising. Subsequent arteriography demonstrated an SGA branch pseudoaneurysm requiring coil embolization. LESSONS: An SGA injury, although uncommon (1.2% incidence), can arise from percutaneous screw placement, aberrant anatomy, or hardware contact. Thorough preoperative imaging, precise robot-assisted screw insertion, and soft tissue protection are crucial to mitigate risks. Immediate angiography aids in prompt diagnosis and effective intervention. Comprehensive knowledge of anatomical variants is essential for managing complications and optimizing preventative measures in robot-assisted SIJ fusion.

2.
J Frailty Sarcopenia Falls ; 9(1): 4-9, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444543

RESUMEN

Objectives: Osteoporosis is associated with greater risk of fracture, which can lead to increased morbidity and mortality. DEXA scans are often inaccessible for patients, leaving many cases of osteoporosis undetected. A portable 3D topographical scan offers an easily accessible and inexpensive potential adjunct screening tool. We hypothesized that 3D scanning of arm and calf circumference and volume would correlate with DEXA T-scores. Methods: 96 female patients were enrolled. Patients were consented and completed a topographical scan of bilateral arms and lower legs with a mobile 3D scanner for arm and calf circumference and volume in clinic. Patient charts were then retrospectively reviewed for DEXA T-scores. Results: Forearm DEXA T-score was positively correlated with arm circumference (r = 0.49, p<0.01), arm volume (r=0.62, p<0.01), and calf volume (r=0.47, p<0.01). Femoral neck DEXA T-score was positively correlated with calf circumference (r=0.36, p<0.01) and calf volume (r=0.36, p<0.01). Conclusions: Our results showed significant correlations between DEXA T-scores and topographical measurements from mobile device acquired 3D scans, although these were in the "moderate" range. Mobile device-based 3D scanning may hold promise as an adjunct screening tool for osteoporosis when DEXA scanning is not available or feasible for patients, although further studies are needed to elucidate the full potential of its clinical utility. At a minimum, identifying a patient as high risk may promote earlier diagnostic DEXA scanning.

3.
Eur J Orthop Surg Traumatol ; 34(2): 1111-1120, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37955721

RESUMEN

INTRODUCTION: Existing research has established a correlation between post-traumatic mental health conditions, including anxiety and depression, and various aspects of recovery, such as pain exacerbations, reduced functional recovery, and lowered patient satisfaction. However, the influence of pre-existing mental health conditions on orthopaedic trauma outcomes has not been thoroughly investigated. The objective of this study was to systematically review literature addressing the association between pre-existing mental health conditions and patient outcomes following surgical interventions for lower extremity fractures in non-geriatric populations. METHODS: A systematic literature review was conducted using Medline, Embase, and Scopus databases following PRISMA-ScR guidelines to select studies that examined lower extremity orthopaedic trauma outcomes in relation to pre-existing mental health conditions. Studies that evaluated patients with surgically treated lower extremity fractures and a history of mental health conditions such as anxiety, depression, or mood disorders were included. Studies with a mean patient age above 65 years of age were excluded to focus on non-geriatric injury patterns. RESULTS: The systematic review identified 12 studies investigating the relationship between surgical outcomes of orthopaedic lower extremity fractures and pre-existing mental health disorders in non-geriatric populations. Studies included patients with pelvis, femur, tibia, and ankle fractures. A majority (83%) of these studies demonstrated that patients with pre-existing mental health diagnoses had inferior functional outcomes, heightened pain levels, or an increase in postoperative complications. DISCUSSION: The presence of pre-existing mental health conditions, particularly anxiety and depression, may predispose orthopaedic trauma patients to an elevated risk of suboptimal functional outcomes, increased pain, or complications after surgical intervention for lower extremity fractures. Future research should focus on interventions that mitigate the impact of mental health conditions on orthopaedic outcomes and patient wellness in this population.


Asunto(s)
Fracturas de Tobillo , Traumatismos de la Pierna , Ortopedia , Humanos , Anciano , Salud Mental , Traumatismos de la Pierna/complicaciones , Traumatismos de la Pierna/cirugía , Extremidad Inferior/cirugía , Extremidad Inferior/lesiones , Dolor
4.
JBJS Case Connect ; 13(4)2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37831804

RESUMEN

CASE: A 16-year-old male patient presented with isolated bilateral sacroiliac (SI) joint dislocation. In this report, we discuss the presentation and focus on strategies for operative reduction and fixation for this rare injury. CONCLUSION: In conclusion, we present a case of a bilateral ligamentous SI joint dislocation in an adolescent. The patient was reduced in the supine position with a sacral bump and bilateral traction with direct and indirect reduction aids inserted through a lateral window. Bilateral SI screws stabilized the pelvis, facilitating uncomplicated healing.


Asunto(s)
Tornillos Óseos , Luxaciones Articulares , Masculino , Adolescente , Humanos , Luxaciones Articulares/diagnóstico por imagen , Luxaciones Articulares/cirugía , Articulación Sacroiliaca/diagnóstico por imagen , Articulación Sacroiliaca/cirugía , Articulación Sacroiliaca/lesiones , Fijación Interna de Fracturas , Pelvis
5.
Cureus ; 15(7): e41283, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37533619

RESUMEN

Background Studies demonstrate that metabolic syndrome (MetS) negatively impacts surgical outcomes. This study sought to identify how metabolic syndrome affects outcomes after open reduction and internal fixation (ORIF) of traumatic pilon fractures. Methods Patients who underwent ORIF for pilon fractures from 2012 to 2019 were identified in the American College of Surgeons National Surgical Quality Improvement Program database. Patients with MetS were compared to non-MetS patients for rates of adverse events, prolonged stay, readmission, discharge location, and operative time in the 30-day postoperative period. All statistical analyses were conducted using SPSS version 26.0 (IBM Corp., Armonk, NY, USA). Paired student t-tests were used to assess continuous variables. Pearson's Chi-square and odds ratios were used for categorical variables. Results A total of 1,915 patients met this study's inclusion criteria, and 127 MetS patients were identified in the cohort. The MetS cohort was older (62.7 vs 49.5 years old, p-value <0.01), with a greater proportion of female patients (59.1% vs 50.2%, p=0.054). MetS patients experienced significantly higher rates of infectious complications (7.9% vs 3.9% OR 2.75 (CI 1.36-5.53), p=0.008), major adverse events (11% vs 4.3%, OR 2.79 (CI 1.53-5.09) p=0.002), and readmissions. MetS patients also had longer lengths of stay (7 days vs 3.8 days, p-value<0.001), and were more likely to be discharged to a non-home location (51.2% vs 19.5%, p-value<0.01, OR 4.32 (CI=3.0-6.24) p<0.001). Conclusion Patients with MetS have an increased risk of 30-day major complications, infection, readmissions, discharge to a non-home location, and prolonged operative time, and therefore warrant additional consideration for perioperative monitoring.

6.
J Shoulder Elbow Surg ; 32(12): 2567-2574, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37579941

RESUMEN

BACKGROUND: The purpose of this study was to perform a meta-analysis of randomized controlled trials (RCTs) to compare outcomes following intramedullary nailing (IMN) vs. open reduction-internal fixation (ORIF) for humeral shaft fractures. METHODS: A literature search of 3 databases was performed based on the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. RCTs comparing IMN and ORIF for humeral shaft fractures were included. Clinical outcomes were compared using RevMan. P < .05 was considered statistically significant. RESULTS: Ten RCTs with 512 patients were included. Overall, 8.4% of patients treated with IMN and 6.4% of patients treated with ORIF had nonunion (P = .57, I2 = 0%), with a significantly faster time to union with IMN (10 weeks vs. 11.9 weeks, P < .05). There was no significant difference in the rate of reoperation (11.6% in IMN group vs. 7.6% in ORIF group, P = .26) or radial nerve palsy (2.8% in IMN group vs. 4.2% in ORIF group, P = .58). A lower rate of infection was noted with IMN (1.2% vs. 5.3%, P < .05). Additionally, there was a lower operative time with IMN (61 minutes vs. 88 minutes, P < .05). CONCLUSIONS: The Level I evidence in the literature does not show a significant difference in rates of union, reoperation, or radial nerve palsy between IMN and ORIF for humeral shaft fractures. Overall, treatment with IMN results in a lower infection rate, less operative time, and a modestly quicker time to union. The optimal treatment strategy for humeral shaft fractures may be best informed by fracture pattern and surgeon preference.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas del Húmero , Neuropatía Radial , Humanos , Fijación Intramedular de Fracturas/métodos , Placas Óseas , Ensayos Clínicos Controlados Aleatorios como Asunto , Fijación Interna de Fracturas/métodos , Fracturas del Húmero/cirugía , Húmero , Resultado del Tratamiento
7.
Eur J Orthop Surg Traumatol ; 33(8): 3299-3305, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37284986

RESUMEN

PURPOSE: Interfragmentary strain influences whether a fracture will undergo direct and indirect fracture healing. Orthopedic trauma surgeons modulate strain and create optimal biomechanical environments for specific fracture patterns using fixation constructs. However, objective intraoperative interfragmentary strain measurement does not currently inform fixation strategy in common practice. This review identifies potential methods and technologies to enable intraoperative strain measurement for guiding optimal fracture fixation strategies. METHODS: PubMed, Scopus, and Web of Science were methodologically queried for manuscripts containing terms related to "bone fracture," "strain," "measurement," and "intraoperative." Manuscripts were systematically screened for relevance and adjudicated by three reviewers. Relevant articles describing methods to measure interfragmentary strain intraoperatively were summarized. RESULTS: After removing duplicates, 1404 records were screened initially. There were 49 manuscripts meeting criteria for in-depth review. Of these, four reports were included in this study that described methods applicable to measuring interfragmentary strain intraoperatively. Two of these reports described a method using instrumented staples, one described optical tracking of Kirschner wires, and one described using a digital linear variable displacement transducer with a custom external fixator. CONCLUSION: The four reports identified by this review describe potential methods to quantify interfragmentary strain after fixation. However, further studies are needed to confirm the precision and accuracy of these measurements across a range of fractures and fixation methods. Additionally, described methods require the insertion and likely removal of additional implants into the bone. Ideally, innovations that measure interfragmentary strain intraoperatively would provide dynamic biomechanical feedback for the surgeon to proactively modulate construct stability.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas , Humanos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Hilos Ortopédicos , Curación de Fractura , Toma de Decisiones , Fenómenos Biomecánicos
8.
J Am Acad Orthop Surg ; 31(13): 669-675, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37294617

RESUMEN

Modern blocking techniques are useful to achieve anatomic alignment and stable fixation during end-segment nailing. Whether with screws or drill bits, blocking implants can correct both angular and translational deformities. Understanding the biomechanics of blocking implants allows the surgeon to properly plan their placement based on principles rather than dogma. We use case examples to highlight updates in blocking techniques during acute surgical fixation and chronic deformity correction.


Asunto(s)
Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/métodos , Tornillos Óseos , Extremidad Inferior
9.
World Neurosurg ; 2023 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-37315895

RESUMEN

BACKGROUND: High-energy traumatic sacral fractures, particularly U-type or AOSpine classification type C fractures, may lead to significant functional deficits. Traditionally, spinopelvic fixation for unstable sacral fractures was performed with open reduction and fixation, but robotic-assisted minimally invasive surgical methods now present new, less invasive approaches. The objective here was to present a series of patients with traumatic sacral fractures treated with robotic-assisted minimally invasive spinopelvic fixation and discuss early experience, considerations, and technical challenges. METHODS: Between June 2022 and January 2023, 7 consecutive patients met the inclusion criteria. Intraoperative fluoroscopic images were merged with intraoperative computed tomography images using a robotic system to plan the trajectories for placement of bilateral lumbar pedicle and iliac screws. Intraoperative computed tomography was performed after pedicle and pelvic screw insertion to confirm appropriate placement before insertion of rods percutaneously without the need for a side connector. RESULTS: The cohort consisted of 7 patients (4 female, 3 male) with ages ranging from 20 to 74. Intraoperatively, the mean blood loss was 85.7 ± 84.0 mL, and mean operative time was 178.4 ± 63.9 minutes. There were no complications in 6 patients; 1 patient experienced both a medially breached pelvic screw and a complicated rod pullout. All patients were safely discharged to their homes or an acute rehabilitation facility. CONCLUSIONS: Our early experience reveals that robotic-assisted minimally invasive spinopelvic fixation for traumatic sacral fractures is a safe and feasible treatment option with the potential to improve outcomes and reduce complications.

10.
Am J Sports Med ; 51(9): 2366-2373, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37358235

RESUMEN

BACKGROUND: Meniscus root tears are associated with chondral injury, early degenerative change, and a high conversion rate to total knee arthroplasty. It is well-established that meniscus root tears lead to decreased femorotibial contact area, increased peak contact pressures, and increased stress on the articular cartilage. PURPOSE: To evaluate the biomechanical characteristics of the all-inside meniscus root repair procedure and compare it with the previously described transtibial technique. STUDY DESIGN: Controlled laboratory study. METHODS: Nine paired cadaveric knees were prepared by removing skin, subcutaneous tissues, quadriceps muscles, patella, and patellar tendon, while leaving the capsule in place. Pressure-mapping sensors were inserted, and specimens underwent compressive loading to obtain peak pressures, mean pressures, and femorotibial contact area in the medial and lateral compartments. Tests were performed as static compression tests with the knee locked at 0° of flexion. Compression testing was performed in 3 states: meniscus intact, meniscus root cut, and after meniscus root repair with an all-inside repair technique. Additionally, testing was completed on 9 pairs of cadaveric knees to compare stiffness and maximal load to failure between the all-inside and transtibial meniscus root repair techniques. RESULTS: In the medial compartment, there were significant increases in median peak pressures and median mean pressures in the root cut state as compared with the intact state (+636 kPA [95% CI, 246 to 1026] and +190 kPA [95% CI, 49 to 330], respectively). All-inside meniscus root repair restored median peak pressures and median mean pressures to approach those of the intact meniscus (+311 kPA [95% CI, -79 to 701] and +137 kPA [95% CI, -3 to 277]). In the lateral compartment, there were also significant increases in median peak pressures and median mean pressures in the root cut state as compared with the intact state (+718 kPA [95% CI, 246 to 1191] and +203 kPA [95% CI, 51 to 355]). All-inside meniscus root repair restored median peak pressures and median mean pressures such that they were not significantly different from the intact state (+322 kPA [95% CI, -150 to 795] and +18 kPA [95% CI, -134 to 171]). There was no difference between repair techniques regarding load to failure (P = .896). Transtibial meniscus root repair had significantly more stiffness (mean ± SD, 24.8 ± 9.3 N/mm) as compared with the all-inside meniscus root repair technique (13.6 ± 3.8 N/mm, P = .015). CONCLUSION: All-inside meniscus root repair reduced median peak and mean pressures to those of the native intact meniscus with the knee in extension in the cadaveric model. When compared with a transtibial meniscus root repair technique, all-inside repair demonstrated decreased stiffness and a similar load to failure. CLINICAL RELEVANCE: All-inside meniscus root repair restored mean and peak femorotibial pressures to those of the intact meniscus. Additionally, it offers a technically easier technique for management of meniscus root tears.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Traumatismos de la Rodilla , Menisco , Lesiones de Menisco Tibial , Humanos , Meniscos Tibiales/cirugía , Traumatismos de la Rodilla/cirugía , Lesiones de Menisco Tibial/cirugía , Fenómenos Biomecánicos/fisiología , Cadáver , Articulación de la Rodilla/cirugía , Menisco/cirugía
11.
J Am Acad Orthop Surg ; 31(12): 641-649, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37162437

RESUMEN

INTRODUCTION: Peripheral nerve blocks (PNB) has been increasingly used in the care of patients with geriatric hip fracture to reduce perioperative opiate use and the need for general anesthesia. However, the associated motor palsy may impair patients' ability to mobilize effectively after surgery and subsequently may increase latency to key mobility milestones postoperatively, as well as increase inpatient length of stay (LOS). The aim of this study was to investigate time-to-mobility milestones and length of hospital stay between peripheral, epidural, and general anesthesia. METHODS: A retrospective review identified 1,351 patients aged 65 years or older who underwent surgery for hip fracture between 2012 and 2018 at a single academic health system. Patients were excluded if baseline nonambulatory, restricted weight-bearing postoperatively, or sustained concomitant injuries precluding mobilization, with a final cohort of 1,013 patients. Time-to-event analyses for discharge and mobility milestones were assessed using univariate Kaplan-Meier and multivariate Cox proportional hazard regression analyses. RESULTS: PNB was associated with delayed postoperative time to ambulation ( P < 0.001) and time to out-of-bed ( P = 0.029), along with increased LOS ( P < 0.001). Epidural anesthesia was associated with less delay to first out-of-bed ( P = 0.002), less delay to ambulation ( P = 0.001), and overall reduced length of stay ( P < 0.001). DISCUSSION: PNB was associated with slower mobilization and longer hospitalization while epidural anesthesia was associated with quicker mobilization and shorter hospital stays. Epidural anesthesia may be a preferable anesthesia choice in patients with geriatric hip fracture when possible. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Anestesia de Conducción , Fracturas de Cadera , Humanos , Anciano , Tiempo de Internación , Fracturas de Cadera/cirugía , Hospitalización , Estudios Retrospectivos
12.
J Am Acad Orthop Surg ; 31(5): 252-257, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36729759

RESUMEN

OBJECTIVE: The purpose of this study was to determine whether type III open high-energy tibia fractures treated with immediate intramedullary nailing (IMN) and primary closure yield low rates of flap coverage. METHODS: Patients with high-energy type IIIA open tibia (OTA/AO42/43) fractures treated with IMN over a 10-year period at a level 1 academic center with at least 90 days of in-person postoperative follow-up were included. Single-stage reamed IMN with acute primary skin closure using Allgower-Donati suture technique was utilized in patients without notable skin loss. The primary outcome was treatment failure of acute primary skin closure requiring subsequent soft-tissue coverage procedures. RESULTS: A total of 111 patients with type IIIA tibia fractures met inclusion criteria. Of 107 of the 111 patients (96%) with skin closure at the index surgery, 95 of the 107 patients (89%) healed their soft-tissue envelop uneventfully. Among the patients who failed primary closure (11%), five required free tissue transfers, five required local rotational flaps, and two underwent split thickness skin grafting only. Patients who failed acute primary closure declared within an average of 8 weeks postoperatively. DISCUSSION: Treatment of type IIIA open high-energy tibia fractures with immediate IMN and primary closure using meticulous soft-tissue handling yields low rates of flap coverage.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas Abiertas , Fracturas de la Tibia , Humanos , Fijación Intramedular de Fracturas/métodos , Tibia , Fracturas de la Tibia/cirugía , Colgajos Quirúrgicos , Piel , Fracturas Abiertas/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Curación de Fractura
13.
Artículo en Inglés | MEDLINE | ID: mdl-36701242

RESUMEN

INTRODUCTION: This is a retrospective study evaluating the use of a new six-item modified frailty index (MF-6) to predict short-term outcomes of patients receiving surgery for lower extremity fractures. METHODS: Patients older than 65 years undergoing open reduction and internal fixation for lower extremity, pelvic, and acetabulum fractures were identified from the American College of Surgeons National Surgical Quality Improvement Program. The MF-6 was calculated by assigning one point for each of six common conditions. Multivariable analysis was used to compare patients with an MF-6 of <3 and ≥3. Outcome measures included complications, mortality, readmission, revision surgery, and length of stay. An area under the curve receiver operator analysis was conducted to compare the MF-6 with MF-5, an existing five-item frailty index. RESULTS: Nine thousand four hundred sixty-three patients were included. Patients with an MF-6 of ≥3 were at markedly higher risk of discharge destination other than home (Exp[B] = 2.09), mortality (Exp[B] = 2.48), major adverse events (Exp[B] = 2.16), and readmission (Exp[B] = 1.82). Receiver-operating curve analysis demonstrated an area under the curve of 0.65 for mortality, 0.62 for major adverse events, and 0.62 for discharge destination other than home, all of which outperformed the MF-5. DISCUSSION: The MF-6 was correlated with a 30-day postoperative incidence of infectious complications, readmission, and discharge destination. MF-6 scores can be used to risk-stratify patient populations as shifts to value-based care continue to develop.


Asunto(s)
Fragilidad , Fracturas de Cadera , Fracturas de la Columna Vertebral , Humanos , Anciano , Estudios Retrospectivos , Fragilidad/complicaciones , Readmisión del Paciente , Complicaciones Posoperatorias/etiología , Fracturas de la Columna Vertebral/complicaciones , Fracturas de Cadera/cirugía , Fracturas de Cadera/complicaciones , Extremidad Inferior
14.
Eur J Orthop Surg Traumatol ; 33(5): 1629-1633, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35788424

RESUMEN

OBJECTIVE: To determine if screw fixation across a cement mantle is safe and effective during plate fixation of well-fixed periprosthetic femur fractures. DESIGN: Retrospective cohort study. SETTING: Academic Level I Trauma Center. PATIENTS: Twenty-eight patients with AO/OTA 32A[B1] or 32A[C] periprosthetic femur fractures treated with open reduction and internal plate and screw fixation after cemented or uncemented hip arthroplasty. INTERVENTION: Screw placement into the cement mantle during internal fixation. OUTCOME MEASUREMENTS: Primary outcome was revision arthroplasty for aseptic loosening. Secondary outcomes included radiographic evidence of aseptic loosening, infection, nonunion, implant failure, and overall reoperation rate. RESULTS: There were 28 patients who met inclusion criteria. A total of 9 patients had screws placed in the cement mantle while the remaining 19 patients had screws placed around an uncemented stem. At a mean of 3.7-year follow-up, there were no cases of revision arthroplasty or aseptic loosening in either group. There were no significant differences in rates of infection, nonunion, implant failure, or reoperation rate between patients who had screw placement into a cement mantle vs around an uncemented stem. CONCLUSION: Drilling into the cement mantle during fixation of a periprosthetic femur fracture around a well-fixed cemented hip stem appears safe and effective. When possible, surgeons can consider bicortical screws around a cemented stem, given the biomechanical advantages over unicortical screw or cerclage fixation. Larger prospective trials confirming the safety of this technique are warranted prior to routine implementation. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Estudios Prospectivos , Estudios Retrospectivos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Reoperación/efectos adversos , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Cementos para Huesos/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fémur/cirugía
15.
J Orthop Trauma ; 36(12): 610-614, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36399672

RESUMEN

OBJECTIVE: To evaluate whether a single proximal interlocking bolt was sufficient during the treatment of extra-articular femur fractures with retrograde medullary nailing. DESIGN: Retrospective comparative study. SETTING: Academic Level 1 trauma center. PATIENTS: The study included 136 patients with extra-articular femur fractures treated with retrograde medullary nailing who met inclusion and follow-up criteria. INTERVENTION: The intervention included surgical treatment for a femur fracture with retrograde medullary nailing, with comparisons made between those treated with a single proximal interlocking (1 IL) bolt and those treated with 2 proximal interlocking bolts (2 IL). MAIN OUTCOME MEASUREMENT: The main outcome measurements were as follows: (1) rate of nonunion and (2) rate of catastrophic implant failure. RESULTS: There was no difference in the rate of nonunion requiring surgical intervention between the 2 groups. There were no catastrophic failures in either group. CONCLUSIONS: A single proximal interlocking bolt may be sufficient when using retrograde nailing for the treatment of extra-articular femur fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/efectos adversos , Estudios Retrospectivos , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Fémur
16.
Injury ; 53(11): 3814-3819, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36064758

RESUMEN

BACKGROUND: Tibial plateau fractures with an ipsilateral compartment syndrome are a clinical challenge with limited guidance regarding the best time to perform open reduction and internal fixation (ORIF) relative to fasciotomy wound closure. This study aimed to determine if the risk of fracture-related infection (FRI) differs based on the timing of tibial plateau ORIF relative to closure of ipsilateral fasciotomy wounds. METHODS: A retrospective cohort study identified patients with tibial plateau fractures and an ipsilateral compartment syndrome treated with 4-compartment fasciotomy at 22 US trauma centers from 2009 to 2019. The primary outcome measure was FRI requiring operative debridement after ORIF. The ORIF timing relative to fasciotomy closure was categorized as ORIF before, at the same time as, or after fasciotomy closure. Bayesian hierarchical regression models with a neutral prior were used to determine the association between timing of ORIF and infection. The posterior probability of treatment benefit for ORIF was also determined for the three timings of ORIF relative to fasciotomy closure. RESULTS: Of the 729 patients who underwent ORIF of their tibial plateau fracture, 143 (19.6%) subsequently developed a FRI requiring operative treatment. Patients sustaining infections were: 21.0% of those with ORIF before (43 of 205), 15.9% at the same time as (37 of 232), and 21.6% after fasciotomy wound closure (63 of 292). ORIF at the same time as fasciotomy closure demonstrated a 91% probability of being superior to before closure (RR, 0.75; 95% CrI, 0.38 to 1.10). ORIF after fasciotomy closure had a lower likelihood (45%) of a superior outcome than before closure (RR, 1.02; 95% CrI; 0.64 to 1.39). CONCLUSION: Data from this multicenter cohort confirms previous reports of a high FRI risk in patients with a tibial plateau fracture and ipsilateral compartment syndrome. Our results suggest that ORIF at the time of fasciotomy closure has the highest probability of treatment benefit, but that infection was common with all three timings of ORIF in this difficult clinical situation.


Asunto(s)
Síndromes Compartimentales , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Teorema de Bayes , Infección de la Herida Quirúrgica/etiología , Factores de Riesgo , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/cirugía , Síndromes Compartimentales/cirugía , Síndromes Compartimentales/complicaciones , Estudios de Cohortes , Resultado del Tratamiento
17.
J Orthop ; 30: 41-45, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35241886

RESUMEN

INTRODUCTION: Though long-term functional outcomes of olecranon fracture plate fixation are favorable, postoperative implant irritation commonly leads to elective removal. We hypothesized that mini-fragment plates will decrease implant removal compared to precontoured plates. METHODS: Patients with isolated olecranon fracture (AO/OTA 2U1-B1) treated with plate fixation were retrospectively reviewed. Patients were stratified into groups based on whether they underwent open reduction and internal fixation with a (1) surgeon contoured mini-fragment or (2) precontoured olecranon-specific plate. Rates of symptomatic implants and implant removal were compared. RESULTS: 98 and 32 patients were treated with precontoured and mini-fragment plates, respectively. Baseline demographics and comorbidities were similar. Mean follow-up was 20.6 months. There were no differences in rates of postoperative complication (22/98, 22.4% vs. 5/32, 15.6%; p = 0.41) or reoperation (37/98, 37.8% vs. 8/32, 25%; p = 0.19). Symptomatic implants were common in the precontoured cohort (44/98, 44.9% vs. 7/32, 21.9%; p < 0.05). Implant removal rates were 36.7% and 18.8%, respectively (p = 0.06). DISCUSSION/CONCLUSION: Olecranon fracture stabilization with mini-fragment plate is associated with lower rates of symptomatic implants, with no difference in postoperative complications or reoperations. Mini-fragment plating is a safe and promising alternative to precontoured plating.

18.
Injury ; 53(4): 1368-1374, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35078617

RESUMEN

OBJECTIVES: High energy long bone fractures with critical bone loss are at risk for nonunion without strategic intervention. We hypothesize that a synthetic membrane implanted at a single stage improves bone healing in a preclinical nonunion model. METHODS: Using standard laboratory techniques, microspheres encapsulating bone morphogenic protein-2 (BMP2) or platelet derived growth factor (PDGF) were designed and coupled to a type 1 collagen sheet. Critical femoral defects were created in rats and stabilized by locked retrograde intramedullary nailing. The negative control group had an empty defect. The induced membrane group (positive control) had a polymethylmethacrylate spacer inserted into the defect for four weeks and replaced with a bare polycaprolactone/beta-tricalcium phosphate (PCL/ß-TCP) scaffold at a second stage. For the experimental groups, a bioactive synthetic membrane embedded with BMP2, PDGF or both enveloped a PCL/ß-TCP scaffold was implanted in a single stage. Serial radiographs were taken at 1, 4, 8, and 12 weeks postoperatively from the definitive procedure and evaluated by two blinded observers using a previously described scoring system to judge union as primary outcome. RESULTS: All experimental groups demonstrated better union than the negative control (p = 0.01). The groups with BMP2 incorporated into the membrane demonstrated higher average union scores than the other groups (p = 0.01). The induced membrane group performed similarly to the PDGF group. Complete union was only demonstrated in groups with BMP2-eluting membranes. CONCLUSIONS: A synthetic membrane comprised of type 1 collagen embedded with controlled release BMP2 improved union of critical bone defects in a preclinical nonunion model.


Asunto(s)
Fosfatos de Calcio , Fijación Intramedular de Fracturas , Animales , Fosfatos de Calcio/farmacología , Fémur , Humanos , Polimetil Metacrilato , Ratas
19.
Injury ; 53(2): 752-755, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34654551

RESUMEN

OBJECTIVE: To determine the accuracy of International Classification of Disease Version 10 (ICD-10) coding for ankle fracture injury patterns. DESIGN: Retrospective cohort study PATIENTS: 97 adult patients with fractures about the ankle (rotational ankle fracture or distal tibia fracture) from 2016 to 2020, selected by stratified random sampling. INTERVENTION: Assignment of an ICD-10 code representative of a rotational ankle fracture, pilon fracture, or unspecified fracture of the lower leg. OUTCOME MEASUREMENTS: Injury radiographs were reviewed by three authors to determine the correct code. Agreement between the correct code and the electronic medical record (EMR) assigned code was determined using kappa's statistic in the aggregate as well as percent agreement, sensitivity, specificity, and positive predictive value (PPV) between individual codes. RESULTS: 59 of 97 cases (60.8%) demonstrated discordance between the existing EMR and surgeon-assigned codes. Aggregate agreement between all codes was fair (K = 0.26). Lateral malleolus fracture codes demonstrated the highest PPV (0.91, 95% CI 0.72-0.99), while the lowest PPV was found for "other fractures of the lower leg" (0.05, 95% CI 0.0-0.24) and "other fracture of the fibula" (0.0, 95% CI 0.0-0.15). Generalized "other fracture" codes comprised 45% of EMR codes compared to only 6% of assigned codes (p < 0.001). EMR codes were specific but not sensitive. CONCLUSION: There is substantial discordance between existing EMR and surgeon-assigned ICD-10 codes for ankle fractures. Database research that relies on ICD-10 coding as a surrogate for primary clinical data should be interpreted with caution and institutions should make efforts to increase the accuracy of their coding.


Asunto(s)
Fracturas de Tobillo , Adulto , Fracturas de Tobillo/diagnóstico por imagen , Bases de Datos Factuales , Humanos , Clasificación Internacional de Enfermedades , Reproducibilidad de los Resultados , Estudios Retrospectivos
20.
Arch Orthop Trauma Surg ; 142(10): 2533-2544, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33829301

RESUMEN

INTRODUCTION: Achieving durable mechanical stability in geriatric intertrochanteric proximal femur fractures remains a challenge. Concomitant poor bone quality, unstable fracture patterns, and suboptimal reduction are additional risk factors for early mechanical failure. Cement augmentation of the proximal locking screw or blade is one proposed method to augment implant anchorage. The purpose of this review is to describe the biomechanical and clinical evidence for cement augmentation of geriatric intertrochanteric fractures, and to elaborate indications for cement augmentation. METHODS: The PubMed database was searched for English language studies up to January 2021. Studies that assessed effect of calcium phosphate or methylmethacrylate cement augmentation during open reduction and internal fixation of intertrochanteric fractures were included. Studies with sample size < 5, nontraumatic or periprosthetic fractures, and nonunion or revision surgery were excluded. Study selection adhered to PRISMA criteria. RESULTS: 801 studies were identified, of which 40 met study criteria. 9 studies assessed effect of cement augmentation on fracture displacement. All but one found that cement decreased fracture displacement. 10 studies assessed effect of cement augmentation on total load or cycles to failure. All but one demonstrated that augmented implants increased this variable. Complication rates of cement augmentation during ORIF of intertrochanteric fractures ranged from 0 to 47%, while non-augmented implants ranged from 0 to 51%. Reoperation rates ranged from 0 to 11% in the cement-augmented group and 0 to 11% in the non-augmented group. Fixation failure ranged from 0 to 11% in the cement-augmented group and 0 to 20% in the non-augmented group. Nonunion ranged from 0 to 3.6% in the cement-augmented group and 0 to 34% in the non-augmented group. CONCLUSIONS: Calcium phosphate or PMMA-augmented CMN fixation of IT fractures increased construct stability and improved outcomes in biomechanical and early clinical studies. The findings of these studies suggest an important role for cement augmentation in patient populations at high risk of mechanical failure.


Asunto(s)
Cementos para Huesos , Fracturas de Cadera , Anciano , Fenómenos Biomecánicos , Tornillos Óseos , Fosfatos de Calcio/uso terapéutico , Fémur , Fijación Interna de Fracturas/métodos , Fracturas de Cadera/cirugía , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...