1.
Rheumatology (Oxford) ; 61(4): 1600-1609, 2022 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-34320649

RESUMEN

OBJECTIVE: The aim of this study was to identify the main CT features that may help in distinguishing a progression of interstitial lung disease (ILD) secondary to SSc from COVID-19 pneumonia. METHODS: This multicentric study included 22 international readers grouped into a radiologist group (RADs) and a non-radiologist group (nRADs). A total of 99 patients, 52 with COVID-19 and 47 with SSc-ILD, were included in the study. RESULTS: Fibrosis inside focal ground-glass opacities (GGOs) in the upper lobes; fibrosis in the lower lobe GGOs; reticulations in lower lobes (especially if bilateral and symmetrical or associated with signs of fibrosis) were the CT features most frequently associated with SSc-ILD. The CT features most frequently associated with COVID- 19 pneumonia were: consolidation (CONS) in the lower lobes, CONS with peripheral (both central/peripheral or patchy distributions), anterior and posterior CONS and rounded-shaped GGOs in the lower lobes. After multivariate analysis, the presence of CONs in the lower lobes (P < 0.0001) and signs of fibrosis in GGOs in the lower lobes (P < 0.0001) remained independently associated with COVID-19 pneumonia and SSc-ILD, respectively. A predictive score was created that was positively associated with COVID-19 diagnosis (96.1% sensitivity and 83.3% specificity). CONCLUSION: CT diagnosis differentiating between COVID-19 pneumonia and SSc-ILD is possible through a combination of the proposed score and radiologic expertise. The presence of consolidation in the lower lobes may suggest COVID-19 pneumonia, while the presence of fibrosis inside GGOs may indicate SSc-ILD.


Asunto(s)
COVID-19 , Enfermedades Pulmonares Intersticiales , Esclerodermia Sistémica , COVID-19/complicaciones , COVID-19/diagnóstico por imagen , Prueba de COVID-19 , Fibrosis , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Enfermedades Pulmonares Intersticiales/complicaciones , Enfermedades Pulmonares Intersticiales/etiología , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen , Esclerodermia Sistémica/patología , Tomografía Computarizada por Rayos X
2.
J Cardiovasc Magn Reson ; 22(1): 31, 2020 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-32375896

RESUMEN

BACKGROUND: The T1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T1 measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B0 and B1, and "reference" slow T1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T1 variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B0 and B1 homogenous, and "reference" T1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T1 times with "reference" T1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R2 ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T1 across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T1 times for clinical use, although temperature correction is required for native T1 tubes at least.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/normas , Fantasmas de Imagen/normas , Consenso , Humanos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
3.
Am J Pathol ; 172(6): 1482-90, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18467700

RESUMEN

Early detection of myocardial dysfunction in Fabry disease (FD) cardiomyopathy suggests the contribution of myofilament structural alterations. Six males with untreated FD cardiomyopathy submitted to cardiac studies, including tissue Doppler imaging and left ventricular endomyocardial biopsy. Active and resting tensions before and after treatment with protein kinase A (PKA) were determined in isolated Triton-permeabilized cardiomyocytes. Cardiomyocyte cross-sectional area, glycosphingolipid vacuole area, myofibrillolysis, and extent of fibrosis were also determined. Biopsies of mitral stenosis in patients with normal left ventricles served as controls. Active tension was four times lower in FD cardiomyocytes and correlated with extent of myofibrillolysis. Resting tension was six times higher in FD cardiomyocytes than in controls. PKA treatment decreased resting tension but did not affect active force. Protein analysis revealed troponin I and desmin degradation products. FD cardiomyocytes were significantly larger and filled with glycosphingolipids. Fibrosis was mildly increased compared with controls. Tissue Doppler imaging lengthening and shortening velocities were reduced in FD cardiomyocytes compared with controls, correlating with resting and active tensions, respectively, but not with cardiomyocyte area, percentage of glycosphingolipids, or extent of fibrosis. In conclusion, myofilament degradation and dysfunction contribute to FD cardiomyopathy. Partial reversal of high resting tension after pharmacological PKA treatment of cardiomyocytes suggests potential benefits from enzyme replacement therapy and/or energy-releasing agents.


Asunto(s)
Citoesqueleto de Actina/patología , Enfermedad de Fabry/patología , Miocitos Cardíacos/patología , Citoesqueleto de Actina/fisiología , Adulto , Fenómenos Biomecánicos , Colágeno/metabolismo , Proteínas Quinasas Dependientes de AMP Cíclico/farmacología , Desmina/metabolismo , Enfermedad de Fabry/fisiopatología , Glicoesfingolípidos/metabolismo , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Mutación , Contracción Miocárdica , Miocardio/metabolismo , Miocardio/patología , Miocitos Cardíacos/efectos de los fármacos , Miocitos Cardíacos/fisiología , Troponina I/metabolismo , alfa-Galactosidasa/genética , alfa-Galactosidasa/metabolismo
4.
Eur J Radiol ; 61(2): 315-23, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17074459

RESUMEN

PURPOSE: Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0M gadobutrol compared to intraarterial DSA in body arteries. MATERIALS AND METHODS: In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. RESULTS: The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6-90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (NPV) for detection of relevant stenosis (>50%) were calculated for the right and left internal carotid arteries, and common and external iliac arteries: Sensitivity was 95-98% (onsite) and 76-96% (BR), specificity 94-96% (onsite) and 86-94% (BR), accuracy 96% (onsite) and 87-93% (BR), NPV 98-99% (onsite) and 84-98% (BR), and PPV 79-93% (onsite) and 44-91% (BR), respectively. CONCLUSION: CeMRA of body arteries using 1.0M gadobutrol provides diagnostic information comparable to intraarterial DSA.


Asunto(s)
Angiografía de Substracción Digital , Arterias/patología , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Constricción Patológica/diagnóstico , Medios de Contraste , Gadolinio , Humanos , Masculino , Persona de Mediana Edad , Compuestos Organometálicos , Estudios Prospectivos , Sensibilidad y Especificidad , Método Simple Ciego