JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048253

RESUMEN

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Factores de Riesgo , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Medición de Riesgo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Estados Unidos/epidemiología , Índice de Severidad de la Enfermedad , Complicaciones Posoperatorias/mortalidad , Recuperación de la Función , Anciano de 80 o más Años , Persona de Mediana Edad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad
2.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36882136

RESUMEN

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Masculino , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
3.
Case Rep Cardiol ; 2022: 2749303, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35342650

RESUMEN

Background: Cancer and ischemic stroke are associated with significant morbidity and mortality. Hypercoagulability, disseminated intravascular coagulation, venous-to-arterial embolism, and non-bacterial thrombotic endocarditis are among recognized mechanisms. Emboli to the brain, or to other organs, are known to occur as a consequence of liberated thrombotic debris originating from the thrombogenic surface of intracardiac neoplastic entities. The most common primary malignancy of the heart is sarcoma; however, masses that occur in the heart are 20 to 40 times more likely as a consequence of metastasis from other sites. Case Report. A 67-year-old woman presented to the emergency room with two brief episodes of dizziness and diplopia for 2 minutes. She had a medical history of provoked upper extremity DVT after a fracture, hypothyroidism, hyperlipidemia, and soft tissue sarcoma. The sarcoma was initially diagnosed in, and subsequently resected from, the right triceps muscle. During posttreatment surveillance, a second lesion was discovered in the left upper pulmonary lobe, and this was also completely resected 9 months following initial diagnosis. We present a case of a woman with a tertiary (cardiac) site sarcoma that presented with embolic stroke. Conclusion: Our case highlights the benefits of multimodality imaging, heart-team approach with oncology support to define anatomy, thereby enable surgical treatment, of a complex intracardiac lesion.

4.
Tex Heart Inst J ; 33(2): 241-5, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16878637

RESUMEN

Endovascular aneurysm repair has considerable potential advantages over the surgical approach as a treatment for thoracic aortic rupture, in part because open surgical repair of ruptured thoracic aortic aneurysms is associated with high mortality and morbidity rates. We describe the successful endovascular deployment of stent-grafts to repair a contained rupture of a descending thoracic aortic aneurysm in an 86-year-old man whose comorbidities prohibited surgery. Two months after the procedure, magnetic resonance angiography showed a patent stent-graft, a patent left subclavian artery, and complete exclusion of the aneurysm.


Asunto(s)
Aneurisma Roto/cirugía , Aneurisma de la Aorta Torácica/cirugía , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Implantación de Prótesis Vascular , Cateterismo , Humanos , Angiografía por Resonancia Magnética , Masculino , Radiografía , Stents
5.
Chest ; 121(4): 1368-72, 2002 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11948081

RESUMEN

Paragonimiasis is an important cause of pulmonary disease worldwide. It results from an infection with Paragonimus, a parasite that reproduces through a complex life cycle involving snails, crustaceans, and mammals. Humans acquire the disease by ingesting uncooked freshwater crab or crayfish. Paragonimus species are distributed globally, and the disease is well known in endemic regions of Asia where culturally based methods of food preparation foster human transmission. Paragonimus also exists in regions of the United States but has been a rare cause of pulmonary disease. We report a case of a previously healthy young man who developed a dense empyema from Paragonimus kellicotti that ultimately required thoracotomy and praziquantel to eradicate his infection.


Asunto(s)
Enfermedades Pulmonares Parasitarias/diagnóstico por imagen , Paragonimiasis/diagnóstico por imagen , Adolescente , Diagnóstico Diferencial , Empiema Pleural/diagnóstico por imagen , Empiema Pleural/patología , Empiema Pleural/cirugía , Humanos , Enfermedades Pulmonares Parasitarias/patología , Enfermedades Pulmonares Parasitarias/cirugía , Masculino , Michigan , Óvulo , Paragonimiasis/patología , Paragonimiasis/cirugía , Recurrencia , Cirugía Torácica Asistida por Video , Tomografía Computarizada por Rayos X