Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
2.
Clin Gastroenterol Hepatol ; 15(6): 820-826, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28528939

RESUMEN

Endoscopic image-enhancement technologies provide opportunities to visualize normal and abnormal tissues within the gastrointestinal (GI) tract in a manner that complements conventional white light endoscopic imaging. The additional information that is obtained enables the endoscopist to better identify, delineate, and characterize lesions and can facilitate targeted biopsies or, in some cases, eliminate the need to send samples for histologic analysis. Some of these technologies have been available for more than a decade, but despite this fact, there is limited use of these technologies by endoscopists. Lack of formalized training in their use and a scarcity of guidelines on implementation of these technologies into clinical practice are contributing factors. In November 2014, the American Gastroenterological Association's Center for GI Innovation and Technology conducted a 2-day workshop to discuss endoscopic image-enhancement technologies. This article represents the third of 3 separate documents generated from the workshop and discusses the published literature pertaining to training and outlines a proposed framework for the implementation of endoscopic image-enhancement technologies in clinical practice. There was general agreement among participants in the workshop on several key considerations. Training and competency assessment for endoscopic image-enhancement technologies should incorporate competency-based education paradigms. To facilitate successful training, multiple different educational models that can cater to variations in learning styles need to be developed, including classroom-style and self-directed programs, in-person and web-based options, image and video atlases, and endoscopic simulator programs. To ensure safe and appropriate use of these technologies over time, refresher courses, skill maintenance programs, and options for competency reassessment should be established. Participants also generally agreed that although early adopters of novel endoscopic image-enhancement modalities can successfully implement these technologies by pursuing training and ensuring self-competency, widespread implementation is likely to require support from GI societies and buy-in from other key stakeholders including payors/purchasers and patients. Continued work by manufacturers and the GI societies in providing training programs and patient education, working with payors and purchasers, and creating environments and policies that motivate endoscopists to adopt new practices is essential in creating widespread implementation.


Asunto(s)
Endoscopía Gastrointestinal/educación , Endoscopía Gastrointestinal/métodos , Aumento de la Imagen/métodos , Preceptoría/métodos , Humanos , Competencia Profesional
3.
Gastrointest Endosc ; 86(6): 1048-1055.e2, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28385584

RESUMEN

BACKGROUND AND AIMS: Direct pancreas juice testing of bicarbonate, lipase, or trypsin after stimulation by secretin or cholecystokinin is used to determine exocrine function, a surrogate for diagnosing chronic pancreatitis (CP). Endoscopic pancreas function tests (ePFTs), where a peak bicarbonate concentration (PBC) ≥80 mEq/L in pancreas juice is considered normal, are now used more frequently. In this ePFT, aspirates start 35 minutes after secretin administration because pancreas output peaks 30 minutes after secretagogue administration. The performance of ePFT in a cohort of patients with a presumptive diagnosis of CP referred to a pancreas clinic for consideration of an intervention including total pancreatectomy and islet autotransplantation was studied, compared with EUS, ERCP, histology, and consensus diagnosis. The effect of sedation, narcotic use, aspirate volume, body mass index, age, and proton pump inhibitors (PPIs) on test performance is reported. METHODS: After a test dose, synthetic human secretin was administered intravenously, and 30 minutes later sedation was achieved with midazolam and fentanyl or propofol. A gastroscope was advanced to the major papilla where 4 continuous aspiration samples were performed at 5-minute intervals in sealed bottles. PBC ≥80 mEq/L was normal. RESULTS: Eighty-one patients had ePFTs from August 2010 through October 2015. Twenty-seven patients (33%) were diagnosed with CP. Eighteen of the 27 patients with CP and 1 of the 54 patients without CP had an abnormal ePFT, producing a sensitivity of 66% (95% CI, 46.0-83.5), specificity 98% (95% CI, 90.1-99.9), positive predictive value 94.7% (95% CI, 74-99.9), and negative predictive value 85.5% (95% CI, 74.2-93.1). ERCP and PBC concordance was generally poor, but none of the patients without CP had major EUS changes, and only 3 patients with a PBC <80 mEq/L had a normal EUS. The PBC was affected by narcotics and PPI use. CONCLUSION: A 20-minute ePFT after secretin administration had a marginal sensitivity for diagnosis of CP. The diagnosis of CP should not rely on a single study and certainly not a PFT. The duodenal aspirate volume did not correlate with the PBC, which contrasts with current secretin-enhanced MRCP knowledge; therefore, further studies on this subject are warranted. Neither type of sedation, BMI, nor age affected test performance. Narcotics and PPIs may affect the PBC, so borderline results should be interpreted with caution in these groups.


Asunto(s)
Endoscopía del Sistema Digestivo , Fármacos Gastrointestinales/administración & dosificación , Pruebas de Función Pancreática/métodos , Jugo Pancreático/química , Pancreatitis Crónica/diagnóstico , Secretina/administración & dosificación , Adulto , Factores de Edad , Bicarbonatos/metabolismo , Índice de Masa Corporal , Colangiopancreatografia Retrógrada Endoscópica , Endosonografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Narcóticos/farmacología , Jugo Pancreático/efectos de los fármacos , Jugo Pancreático/metabolismo , Pancreatitis Crónica/diagnóstico por imagen , Pancreatitis Crónica/patología , Valor Predictivo de las Pruebas , Inhibidores de la Bomba de Protones/farmacología , Sensibilidad y Especificidad , Factores de Tiempo
4.
Wound Repair Regen ; 24(3): 589-95, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27027492

RESUMEN

It is widely accepted that elevated protease activity (EPA) in chronic wounds impedes healing. However, little progress has occurred in quantifying the level of protease activity that is detrimental for healing. The aim of this study was to determine the relationship between inflammatory protease activity and wound healing status, and to establish the level of EPA above which human neutrophil-derived elastase (HNE) and matrix metalloproteases (MMP) activities correlate with nonhealing wounds. Chronic wound swab samples (n = 290) were collected from four wound centers across the USA to measure HNE and MMP activity. Healing status was determined according to percentage reduction in wound area over the previous 2-4 weeks; this was available for 211 wounds. Association between protease activity and nonhealing wounds was determined by receiver operating characteristic analysis (ROC), a statistical technique used for visualizing and analyzing the performance of diagnostic tests. ROC analysis showed that area under the curve (AUC) for HNE were 0.69 for all wounds and 0.78 for wounds with the most reliable wound trajectory information, respectively. For MMP, the corresponding AUC values were 0.70 and 0.82. Analysis suggested that chronic wounds having values of HNE >5 and/or MMP ≥13, should be considered wound healing impaired. EPA is indicative of nonhealing wounds. Use of a diagnostic test to detect EPA in clinical practice could enable clinicians to identify wounds that are nonhealing, thus enabling targeted treatment with protease modulating therapies.


Asunto(s)
Inhibidores Enzimáticos/uso terapéutico , Péptido Hidrolasas/metabolismo , Cicatrización de Heridas , Heridas y Lesiones/diagnóstico , Heridas y Lesiones/terapia , Área Bajo la Curva , Pie Diabético/diagnóstico , Pie Diabético/enzimología , Pie Diabético/fisiopatología , Pie Diabético/terapia , Activación Enzimática/efectos de los fármacos , Inhibidores Enzimáticos/farmacología , Humanos , Metaloproteinasas de la Matriz/metabolismo , Úlcera por Presión/diagnóstico , Úlcera por Presión/enzimología , Úlcera por Presión/fisiopatología , Úlcera por Presión/terapia , Curva ROC , Resultado del Tratamiento , Úlcera Varicosa/enzimología , Úlcera Varicosa/fisiopatología , Úlcera Varicosa/terapia , Cicatrización de Heridas/efectos de los fármacos , Heridas y Lesiones/enzimología , Heridas y Lesiones/fisiopatología
5.
Clin Gastroenterol Hepatol ; 13(13): 2209-18, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26462567

RESUMEN

Enhanced imaging technologies such as narrow band imaging, flexible spectral imaging color enhancement, i-Scan, confocal laser endomicroscopy, and optical coherence tomography are readily available for use by endoscopists in routine clinical practice. In November 2014, the American Gastroenterological Association's Center for GI Innovation and Technology conducted a 2-day workshop to discuss endoscopic image enhancement technologies, focusing on their role in 2 specific clinical conditions (colon polyps and Barrett's esophagus) and on issues relating to training and implementation of these technologies (white papers). Although the majority of the studies that use enhanced imaging technologies have been positive, these techniques ideally need to be validated in larger cohorts and in community centers. As it stands today, detailed endoscopic examination with high-definition white-light endoscopy and random 4-quadrant biopsy remains the standard of care. However, the workshop panelists agreed that in the hands of endoscopists who have met the preservation and incorporation of valuable endoscopic innovation thresholds (diagnostic accuracy) with enhanced imaging techniques (specific technologies), use of the technique in Barrett's esophagus patients is appropriate.


Asunto(s)
Esófago de Barrett/diagnóstico , Procesamiento de Imagen Asistido por Computador/métodos , Imagen Óptica/métodos , Pólipos del Colon/diagnóstico , Humanos , Procesamiento de Imagen Asistido por Computador/tendencias , Imagen Óptica/tendencias
6.
Clin Gastroenterol Hepatol ; 13(11): 1860-6; quiz e168-9, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26192139

RESUMEN

Diminutive colon polyps, defined as 5 mm or less, are encountered increasingly at colonoscopy. The risk of serious pathology in such polyps is low. There is a risk and cost of resecting all such polyps and sending tissue for pathologic evaluation. Enhancement of endoluminal imaging may enable discrimination of neoplastic vs non-neoplastic polyps. If this discrimination can be performed accurately with high confidence, it may be possible to either resect and discard diminutive adenomas, or inspect and do-not-resect diminutive hyperplastic polyps. In 2011, an expert group recommended thresholds of 90% negative predictive value for adenomas, and 90% accuracy in predicting appropriate surveillance intervals. Since 2011, criteria for polyp discrimination have been published and validated by experts and nonexperts. In vivo studies have been performed to compare endoscopic impression and pathologic diagnosis. An expert panel was convened in late 2014 to review the literature to determine if the proposed thresholds for discrimination can be attained and to recommend the next steps for introducing changes in clinical practice. We conclude that threshold levels can be achieved with several endoscopic image enhancements. The next steps to implementation of practice change include acquiring data on training and competence, determining best practices for auditing performance, understanding patient education needs, and the potential cost benefit of such changes.


Asunto(s)
Neoplasias del Colon/diagnóstico , Neoplasias del Colon/cirugía , Colonoscopía/métodos , Imagen Óptica/métodos , Pólipos/diagnóstico , Pólipos/cirugía , Humanos
7.
Cancer Discov ; 5(6): 636-51, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25829425

RESUMEN

UNLABELLED: We have recently recapitulated metastasis of human PTEN/TP53-mutant prostate cancer in the mouse using the RapidCaP system. Surprisingly, we found that this metastasis is driven by MYC, and not AKT, activation. Here, we show that cell-cell communication by IL6 drives the AKT-MYC switch through activation of the AKT-suppressing phosphatase PHLPP2, when PTEN and p53 are lost together, but not separately. IL6 then communicates a downstream program of STAT3-mediated MYC activation, which drives cell proliferation. Similarly, in tissues, peak proliferation in Pten/Trp53-mutant primary and metastatic prostate cancer does not correlate with activated AKT, but with STAT3/MYC activation instead. Mechanistically, MYC strongly activates the AKT phosphatase PHLPP2 in primary cells and prostate cancer metastasis. We show genetically that Phlpp2 is essential for dictating the proliferation of MYC-mediated AKT suppression. Collectively, our data reveal competition between two proto-oncogenes, MYC and AKT, which ensnarls the Phlpp2 gene to facilitate MYC-driven prostate cancer metastasis after loss of Pten and Trp53. SIGNIFICANCE: Our data identify IL6 detection as a potential causal biomarker for MYC-driven metastasis after loss of PTEN and p53. Second, our finding that MYC then must supersede AKT to drive cell proliferation points to MYC inhibition as a critical part of PI3K pathway therapy in lethal prostate cancer.


Asunto(s)
Genes myc , Interleucina-6/metabolismo , Neoplasias/genética , Neoplasias/metabolismo , Fosfohidrolasa PTEN/deficiencia , Fosfoproteínas Fosfatasas/metabolismo , Proteínas Proto-Oncogénicas c-akt/metabolismo , Proteína p53 Supresora de Tumor/deficiencia , Animales , Comunicación Celular/genética , Proliferación Celular , Epitelio/metabolismo , Epitelio/patología , Eliminación de Gen , Genotipo , Humanos , Neoplasias Pulmonares/secundario , Masculino , Ratones , Mutación , Metástasis de la Neoplasia , Neoplasias/patología , Fosforilación , Neoplasias de la Próstata/genética , Neoplasias de la Próstata/metabolismo , Neoplasias de la Próstata/patología , Unión Proteica , Factor de Transcripción STAT3/metabolismo , Transducción de Señal , Células del Estroma/metabolismo
8.
Proc (Bayl Univ Med Cent) ; 28(2): 227-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25829662

RESUMEN

We describe a 68-year-old man who presented with headaches, nausea, and dizziness and was found to have a superior sagittal sinus venous thrombosis on magnetic resonance imaging. His initial hypercoagulable workup was negative. Computed tomography of the abdomen revealed a large mass originating from the kidney. A radical nephrectomy was performed at an outside hospital, and histological study of the excised mass disclosed clear cell renal carcinoma.

9.
Artículo en Inglés | MEDLINE | ID: mdl-24995164

RESUMEN

Shiga toxin-producing Escherichia coli (STEC) and Salmonella are food-borne pathogens commonly associated with beef, and reliable methods are needed to determine their prevalence in beef and to ensure food safety. Retail ground beef was tested for the presence of E. coli O157:H7, STEC serogroups O26, O45, O103, O111, O121, and O145, and Salmonella using the DuPont™ BAX® system method. Ground beef (325 g) samples were enriched in 1.5 L of TSB with 2 mg/L novobiocin at 42°C for 18 h, and then evaluated using the BAX® System real-time PCR assays for E. coli O157:H7 and STEC suite, and the BAX® System standard PCR assays for E. coli O157:H7 MP and Salmonella. Samples positive for STEC target genes by the BAX® System assays were subjected to immunomagnetic separation (IMS) and plating onto modified Rainbow Agar O157. Enrichments that were PCR positive for Salmonella were inoculated into RV broth, incubated for 18 h at 42°C, and then plated onto XLT-4 agar. Presumptive positive STEC and Salmonella colonies were confirmed using the BAX® System assays. Results of the BAX® System STEC assays showed 20/308 (6.5%) of samples positive for both the Shiga toxin (stx) and intimin (eae) genes; 4 (1.3%) for stx, eae, and O26; 1 (0.3%) for stx, eae, and O45; 3 (1%) for stx, eae, and O103; and 1 (0.3%) for stx, eae, and O145. There were also 3 samples positive for stx, eae, and more than one STEC serogroup. Three (1.0%) of the samples were positive using the BAX® System real-time E. coli O157:H7 assay, and 28 (9.1%) were positive using the BAX® System Salmonella assay. STEC O103 and E. coli O157:H7 were isolated from 2/6 and 2/3 PCR positive samples, respectively. Salmonella isolates were recovered and confirmed from 27 of the 28 Salmonella PCR positive samples, and a portion of the isolates were serotyped and antibiotic resistance profiles determined. Results demonstrate that the BAX® System assays are effective for detecting STEC and Salmonella in beef.


Asunto(s)
Técnicas Bacteriológicas/métodos , Carne/microbiología , Técnicas de Diagnóstico Molecular/métodos , Salmonella/aislamiento & purificación , Toxina Shiga/genética , Escherichia coli Shiga-Toxigénica/aislamiento & purificación , Adhesinas Bacterianas/genética , Animales , Bovinos , Proteínas de Escherichia coli/genética , Humanos , Pruebas de Sensibilidad Microbiana , Prevalencia , Salmonella/clasificación , Salmonella/genética , Serotipificación , Escherichia coli Shiga-Toxigénica/clasificación , Escherichia coli Shiga-Toxigénica/genética
10.
J AOAC Int ; 97(3): 868-75, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25051636

RESUMEN

A multilaboratory study was conducted to evaluate the ability of the DuPont BAX System Real-Time PCR Assay for Salmonella to detect the target species in a variety of foods and environmental surfaces. Internal validation studies were performed by DuPont Nutrition & Health on 24 different sample types to demonstrate the reliability of the test method among a wide variety of sample types. Two of these matrixes-pork and turkey frankfurters and pasteurized, not-from-concentrate orange juice without pulp-were each evaluated in 14 independent laboratories as part of the collaborative study to demonstrate repeatability and reproducibility of the internal laboratory results independent of the end user. Frankfurter samples were evaluated against the U.S. Department of Agriculture, Food Safety and Inspection Service reference method as a paired study, while orange juice samples were evaluated against the U.S. Food and Drug Administration reference method as an unpaired study, using a proprietary media for the test method. Samples tested in this study were artificially inoculated with a Salmonella strain at levels expected to produce low (0.2-2.0 CFU/test portion) or high (5 CFU/test portion) spike levels on the day of analysis. For each matrix, the collaborative study failed to show a statistically significant difference between the candidate method and the reference method using the probability of detection statistical model.


Asunto(s)
Técnicas Bacteriológicas/métodos , Microbiología de Alimentos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Salmonella/aislamiento & purificación , Reproducibilidad de los Resultados , Salmonella/genética
11.
J Food Prot ; 77(2): 180-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24490911

RESUMEN

The "top-six" non-O157 Shiga toxin-producing Escherichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) most frequently associated with outbreaks and cases of foodborne illnesses have been declared as adulterants in beef by the U.S. Department of Agriculture Food Safety and Inspection Service (FSIS). Regulatory testing in beef began in June 2012. The purpose of this study was to evaluate the DuPont BAX System method for detecting these top six STEC strains and strains of E. coli O157:H7. For STEC, the BAX System real-time STEC suite was evaluated, including a screening assay for the stx and eae virulence genes and two panel assays to identify the target serogroups: panel 1 detects O26, O111, and O121, and panel 2 detects O45, O103, O145. For E. coli O157:H7, the BAX System real-time PCR assay for this specific serotype was used. Sensitivity of each assay for the PCR targets was ≥1.23 × 10(3) CFU/ml in pure culture. Each assay was 100% inclusive for the strains tested (20 to 50 per assay), and no cross-reactivity with closely related strains was observed in any of the assays. The performance of the BAX System methods was compared with that of the FSIS Microbiology Laboratory Guidebook (MLG) methods for detection of the top six STEC and E. coli O157:H7 strains in ground beef and beef trim. Generally, results of the BAX System method were similar to those of the MLG methods for detecting non-O157 STEC and E. coli O157:H7. Reducing or eliminating novobiocin in modified tryptic soy broth (mTSB) may improve the detection of STEC O111 strains; one beef trim sample inoculated with STEC O111 produced a negative result when enriched in mTSB with 8 mg/liter novobiocin but was positive when enriched in mTSB without novobiocin. The results of this study indicate the feasibility of deploying a panel of real-time PCR assay configurations for the detection and monitoring of the top six STEC and E. coli O157:H7 strains in beef. The approach could easily be adapted for additional multiplex assays should regulations expand to include other O serogroups or virulence genes.


Asunto(s)
Contaminación de Alimentos/análisis , Carne/microbiología , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Escherichia coli Shiga-Toxigénica/aislamiento & purificación , Animales , Técnicas Bacteriológicas/métodos , Bovinos , Proteínas de Escherichia coli/genética , Inspección de Alimentos/métodos , Inspección de Alimentos/normas , Microbiología de Alimentos , Humanos , Sensibilidad y Especificidad , Estados Unidos
12.
Proc (Bayl Univ Med Cent) ; 26(3): 311-3, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23814401
13.
Gastroenterology ; 145(1): 129-137.e3, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23567348

RESUMEN

BACKGROUND & AIMS: Weight regain or insufficient loss after Roux-en-Y gastric bypass (RYGB) is common. This is partially attributable to dilatation of the gastrojejunostomy (GJ), which diminishes the restrictive capacity of RYGB. Endoluminal interventions for GJ reduction are being explored as alternatives to revision surgery. We performed a randomized, blinded, sham-controlled trial to evaluate weight loss after sutured transoral outlet reduction (TORe). METHODS: Patients with weight regain or inadequate loss after RYGB and GJ diameter greater than 2 cm were assigned randomly to groups that underwent TORe (n = 50) or a sham procedure (controls, n = 27). Intraoperative performance, safety, weight loss, and clinical outcomes were assessed. RESULTS: Subjects who received TORe had a significantly greater mean percentage weight loss from baseline (3.5%; 95% confidence interval, 1.8%-5.3%) than controls (0.4%; 95% confidence interval, 2.3% weight gain to 3.0% weight loss) (P = .021), using a last observation carried forward intent-to-treat analysis. As-treated analysis also showed greater mean percentage weight loss in the TORe group than controls (3.9% and 0.2%, respectively; P = .014). Weight loss or stabilization was achieved in 96% subjects receiving TORe and 78% of controls (P = .019). The TORe group had reduced systolic and diastolic blood pressure (P < .001) and a trend toward improved metabolic indices. In addition, 85% of the TORe group reported compliance with the healthy lifestyle eating program, compared with 53.8% of controls; 83% of TORe subjects said they would undergo the procedure again, and 78% said they would recommend the procedure to a friend. The groups had similar frequencies of adverse events. CONCLUSIONS: A multicenter randomized trial provides Level I evidence that TORe reduces weight regain after RYGB. These results were achieved using a superficial suction-based device; greater levels of weight loss could be achieved with newer, full-thickness suturing devices. TORe is one approach to avoid weight regain; a longitudinal multidisciplinary approach with dietary counseling and behavioral changes are required for long-term results. ClinicalTrials.gov identifier: NCT00394212.


Asunto(s)
Anastomosis en-Y de Roux , Derivación Gástrica/métodos , Técnicas de Sutura , Pérdida de Peso , Adolescente , Adulto , Anciano , Endoscopía Gastrointestinal , Femenino , Derivación Gástrica/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
16.
World J Gastroenterol ; 18(26): 3400-8, 2012 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-22807609

RESUMEN

AIM: To determine which patients might benefit most from retrograde viewing during colonoscopy through subset analysis of randomized, controlled trial data. METHODS: The Third Eye® Retroscope® Randomized Clinical Evaluation (TERRACE) was a randomized, controlled, multicenter trial designed to evaluate the efficacy of a retrograde-viewing auxiliary imaging device that is used during colonoscopy to provide a second video image which allows viewing of areas on the proximal aspect of haustral folds and flexures that are difficult to see with the colonoscope's forward view. We performed a post-hoc analysis of the TERRACE data to determine whether certain subsets of the patient population would gain more benefit than others from use of the device. Subjects were patients scheduled for colonoscopy for screening, surveillance or diagnostic workup, and each underwent same-day tandem examinations with standard colonoscopy (SC) and Third Eye colonoscopy (TEC), randomized to SC followed by TEC or vice versa. RESULTS: Indication for colonoscopy was screening in 176/345 subjects (51.0%), surveillance after previous polypectomy in 87 (25.2%) and diagnostic workup in 82 (23.8%). In 4 subjects no indication was specified. Previously reported overall results had shown a net additional adenoma detection rate (ADR) with TEC of 23.2% compared to SC. Relative risk (RR) of missing adenomas with SC vs TEC as the initial procedure was 1.92 (P = 0.029). Post-hoc subset analysis shows additional ADRs for TEC compared to SC were 4.4% for screening, 35.7% for surveillance, 55.4% for diagnostic and 40.7% for surveillance and diagnostic combined. The RR of missing adenomas with SC vs TEC was 1.11 (P = 0.815) for screening, 3.15 (P = 0.014) for surveillance, 8.64 (P = 0.039) for diagnostic and 3.34 (P = 0.003) for surveillance and diagnostic combined. Although a multivariate Poisson regression suggested gender as a possibly significant factor, subset analysis showed that the difference between genders was not statistically significant. Age, bowel prep quality and withdrawal time did not significantly affect the RR of missing adenomas with SC vs TEC. Mean sizes of adenomas detected with TEC and SC were similar at 0.59 cm and 0.56 cm, respectively (P = NS). CONCLUSION: TEC allows detection of significantly more adenomas compared to SC in patients undergoing surveillance or diagnostic workup, but not in screening patients (ClinicalTrials.gov Identifier: NCT01044732).


Asunto(s)
Adenoma/diagnóstico , Neoplasias del Colon/diagnóstico , Colonoscopía/métodos , Endoscopios , Oncología Médica/métodos , Adenoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias del Colon/patología , Detección Precoz del Cáncer , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Análisis de Regresión , Reproducibilidad de los Resultados
18.
Clin Gastroenterol Hepatol ; 9(12): 1044-9, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21871249

RESUMEN

Clostridium difficile infection is increasing in incidence, severity, and mortality. Treatment options are limited and appear to be losing efficacy. Recurrent disease is especially challenging; extended treatment with oral vancomycin is becoming increasingly common but is expensive. Fecal microbiota transplantation is safe, inexpensive, and effective; according to case and small series reports, about 90% of patients are cured. We discuss the rationale, methods, and use of fecal microbiota transplantation.


Asunto(s)
Clostridioides difficile/aislamiento & purificación , Infecciones por Clostridium/terapia , Heces/microbiología , Probióticos/administración & dosificación , Humanos , Resultado del Tratamiento
19.
J AOAC Int ; 94(3): 863-71, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21797015

RESUMEN

The new BAX System PCR Assay for Genus Listeria 24E was evaluated for detecting Listeria spp. in frankfurters, spinach, cooked shrimp, queso fresco cheese, and on stainless steel surfaces with a single-stage enrichment in BAX System 24 Listeria Enrichment Broth (24 LEB). Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the U.S. Food and Drug Administration's Bacteriological Analytical Manual and the U.S. Department of Agriculture-Food Safety and Inspection Service culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined, within the range of deviations from specified parameters examined, affect the performance of the assay.


Asunto(s)
Técnicas Bacteriológicas/métodos , Microbiología de Alimentos , Listeria/aislamiento & purificación , Microbiología Ambiental , Contaminación de Equipos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...