Semin Thromb Hemost ; 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39151905

RESUMEN

External quality assessment (EQA) is used to evaluate laboratory performance in tests of hemostasis; however, some esoteric tests are performed by too few centers in any one EQA program to allow valid statistical assessment. To explore the feasibility of pooling data from several EQA providers, an exercise was carried out by the External Quality Assurance in Thrombosis and Haemostasis group, using the International Society on Thrombosis and Haemostasis Scientific and Standardization Committee (SSC) plasma standard for thrombophilia screening assays. Six EQA providers took part in this exercise, distributing the SSC plasma standard as a "blinded" sample to participants for thrombophilia tests between November 2020 and December 2021. Data were collected by each provider, anonymized, and pooled for analysis. Results were analyzed as overall results from each EQA provider, and by kit/method-specific comparisons of data from all providers pooled together. For each parameter, median results and range were determined. Over 1,250 sets of data were returned in the six EQA programs. The overall medians (all data pooled) were <4% of the assigned values for each parameter with the exception of protein C activity by clot-based assay. Method-related differences in median results were observed for free protein S antigen and protein S activity-a pattern seen across data from the different EQA providers. Antithrombin antigen results reported in mg/dL provided an example where small numbers of results for a single EQA provider may be supplemented by pooling data from multiple providers with good agreement seen among results reported by the different EQA providers. This study demonstrated that a multicenter EQA provider collaboration can be carried out and demonstrated benefit for assays with smaller number of participants. In addition, results showed good agreement with the assigned values of the SSC plasma standard. Further exercises for tests performed by only small numbers of laboratories can be planned.

2.
Int J Lab Hematol ; 46(4): 731-740, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38644463

RESUMEN

INTRODUCTION: Direct oral anticoagulants (DOACs) reflect anticoagulation agents given to treat or prevent thrombosis, having largely replaced vitamin K antagonists (VKAs) such as warfarin. DOACs are given in fixed daily doses and generally do not need monitoring. However, there may be a variety of reasons that justify measurement of plasma DOAC levels in individual patients. METHODS: We report updated findings for DOAC testing in our geographic region, using recent data from the RCPAQAP, an international external quality assessment (EQA) program, currently with some 40-60 participants in each of the different DOAC (rivaroxaban, apixaban, dabigatran) modules, to assess laboratory performance in this area. Data has been assessed for the past 5 years (2019-2023 inclusive), with 20 samples each per DOAC. RESULTS: Data shows a limited repertoire of assays in use, and mostly consistency in reported numerical values when assessing proficiency samples. Available assays mostly comprised reagents from four manufacturing suppliers. There was good consistency across what participants identified as 'DOAC detected', but some variability when participants attempted to grade DOAC levels as low vs moderate vs high. Inter-laboratory/method coefficient of variation (CVs) were generally <15% for each DOAC, when present at >100 ng/mL. CONCLUSION: We hope our findings, reflecting on mostly consistent reporting of DOAC levels and interpretation provides reassurance for clinicians requesting these measurements, and helps support their implementation in regions where there is a paucity of test availability.


Asunto(s)
Anticoagulantes , Humanos , Administración Oral , Anticoagulantes/administración & dosificación , Pruebas de Coagulación Sanguínea/normas , Pruebas de Coagulación Sanguínea/métodos , Hemostasis/efectos de los fármacos , Rivaroxabán/sangre , Piridonas/administración & dosificación , Australasia , Dabigatrán , Monitoreo de Drogas/métodos , Monitoreo de Drogas/normas , Pirazoles/uso terapéutico , Pirazoles/administración & dosificación , Pirazoles/sangre
3.
Semin Thromb Hemost ; 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38428840

RESUMEN

D-dimers represent the breakdown products of fibrin. Thus, elevated plasma D-dimers will arise following a thrombotic event, such as a deep vein thrombosis or a pulmonary embolism, and therefore, a nonelevated D-dimer is used to effectively exclude such events. D-dimers are also elevated in a range of other conditions, for example, during disseminated intravascular coagulation. D-dimer levels may also be associated with prognostic value. For example, highly raised D-dimer levels can be associated with worsening clinical features in coronavirus disease 2019. Thus, D-dimer testing represents a commonly requested hemostasis test, often performed in 24/7 laboratories. Unfortunately, D-dimer testing is neither standardized nor harmonized across manufacturers or laboratories. Indeed, considering reporting units and the magnitude of units, up to 28 different combinations may be reported by laboratories. We provide updated findings for D-dimer testing in our geographic region, using recent data from the Royal College of Pathologists of Australasia Quality Assurance Programs, an international external quality assessment program, currently with over 450 participants in the D-dimer module. Data show a wide variety of assays in use and variable outcomes in reported numerical values when assessing proficiency samples. D-dimer testing mostly comprised reagents from three main manufacturing suppliers, with a small number of users of reagents from other manufacturers. Reported results showed important differences in numerical values for the same homogeneous tested samples when normalized to a single reporting unit (e.g., mg/L). Nevertheless, despite using different test reagents and reporting, most participants uniformly identified D-dimer values as below or above a "detection" cut-off for samples that were constructed to be below or above most cut-off values. As expected, mixed findings were reported for samples containing levels around expected cut-off values. We hope that our findings, reflecting on the heterogeneity of test reagents and test data, help improve diagnostic testing for D-dimer testing and facilitate harmonization and standardization, in the future.