Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Clin Res Cardiol ; 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38112746

RESUMEN

BACKGROUND: Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important. OBJECTIVE: To assess the performance of cryoablation procedural markers to predict long-term PVI. METHODS: In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. - 15 °C in the first 15 s of the ablation impulse). RESULTS: 47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05-0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27-7.74], p = 0.01) were the only variables independently associated with PV reconnection. CONCLUSION: T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI.

2.
J Clin Med ; 12(20)2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37892704

RESUMEN

Aims-Electrocardiography (ECG) and echocardiographic left atrial (LA) parameters may be helpful to assess the risk of atrial fibrillation (AF) in embolic stroke of unknown etiology (ESUS) and could therefore guide intensity of ECG monitoring. Methods-1153 consecutive patients with ischemic stroke or transient ischemic attack (TIA) were analyzed. An internal loop recorder (ILR) was implanted in 104 consecutive patients with ESUS. Multiple morphologic P-wave parameters in baseline 12-channel ECG and echocardiographic LA parameters were measured and analyzed in patients with and without ILR-detected AF. Using logistic regression, we evaluated the predictive value of several ECG parameters and LA dimensions on the occurrence of AF. Results-In 20 of 104 (19%) patients, AF was diagnosed by ILR during a mean monitoring time of 575 (IQR 470-580) days. Patients with AF were significantly older (72 (67-75) vs. 60 (52-72) years; p = 0.001) and premature atrial contractions (PAC) were more frequently observed (40% vs. 2%; p < 0.001) during baseline ECG. All morphologic P-wave parameters did not show a significant difference between groups. There was a non-significant trend towards a larger LA volume index (31 (24-36) vs. 29 (25-37) mL/m2; p = 0.09) in AF patients. Conclusions-Age and PAC are independently associated with incident AF in ESUS and could be used as markers for selecting patients that may benefit from more extensive rhythm monitoring or ILR implantation. In our consecutive cohort of patients with ESUS, neither morphological P-wave parameters nor LA size were predictive of AF.

3.
J Pers Med ; 11(11)2021 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-34834528

RESUMEN

BACKGROUND: Different electrocardiogram (ECG) findings are known to be independent predictors of clinical response to cardiac resynchronization therapy (CRT). It remains unknown how these findings influence very long-term prognosis. METHODS AND RESULTS: A total of 102 consecutive patients (75 males, mean age 65 ± 10 years) referred to our center for CRT implantation had previously been included in this prospective observational study. The same patient group was now re-evaluated for death from all causes over a prolonged median follow-up of 10.3 years (interquartile range 9.4-12.5 years). During follow-up, 55 patients died, and 82% of the clinical non-responders (n = 23) and 44% of the responders (n = 79) were deceased. We screened for univariate associations and found QRS width during biventricular (BIV) pacing (p = 0.02), left ventricular (LV) pacing (p < 0.01), Δ LV paced-right ventricular (RV) paced (p = 0.03), age (p = 0.03), New York Heart Association (NYHA) class (p < 0.01), CHA2DS2-Vasc score (p < 0.01), glomerular filtration rate (p < 0.01), coronary artery disease (p < 0.01), non-ischemic cardiomyopathy (NICM) (p = 0.01), arterial hypertension (p < 0.01), NT-proBNP (p < 0.01), and clinical response to CRT (p < 0.01) to be significantly associated with mortality. In the multivariate analysis, NICM, the lower NYHA class, and smaller QRS width during BIV pacing were independent predictors of better outcomes. CONCLUSION: Our data show that QRS width duration during biventricular pacing, an ECG parameter easily obtainable during LV lead placement, is an independent predictor of mortality in a long-term follow-up. Our data add further evidence that NICM and lower NYHA class are independent predictors for better outcome after CRT implantation.

4.
J Pers Med ; 11(9)2021 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-34575689

RESUMEN

INTRODUCTION: Multiple studies have shown that left atrial (LA) enlargement is a strong predictor of poor outcome after catheter ablation of atrial fibrillation (AF). LA size is commonly approximated as the diameter in the parasternal long axis. It remains unknown whether more precise echocardiographic measurements of LA size allow for better correlation with outcome after pulmonary vein isolation (PVI). METHODS AND RESULTS: We performed a retrospective study of 131 consecutive patients (43 females, 60% paroxysmal AF, mean CHA2DS2-Vasc score 1.6, mean age 61 ± 12 years) referred for PVI. Measurements of the LA were carried out by a single observer in transthoracic echocardiograms (TTE) performed prior to ablation. We calculated diameter of the LA in the parasternal long axis (PLAX), LA area in the 2- as well as 4-Chamber (CH) view. LA volume was computed using the disc summation technique (LAV) and indexed to body surface area (LAVI). Procedural and follow-up data were gathered from a prospective AF database. Ablation was performed exclusively using the second generation cryoballoon by the same operators. Follow-up visits at 3, 6 and 12 months showed freedom from AF in 76%, 73% and 73% respectively. Mean values of LA calculations were LAPLAX: 37.9 mm ± 6.3 mm, 2CH area: 22.5 cm2 ± 6.7 cm2, 4CH area: 21.4 cm2 ± 5.5 cm2, LAV: 73.7 mL ± 26.1 mL and LAVI: 36.2 mL/m2 ± 12.7 mL/m2, respectively. C statistic revealed the best concordance of LAVI with outcome after 12 months (C = 0.67), LAV also exhibited a satisfactory value (C = 0.61) in comparison to surfaces in 2CH (C = 0.59) and 4CH (C = 0.57). PLAX showed the worst correlation (C = 0.51). Additionally, different binary logistic regression models identified three independent predictors of AF outcome after cryoballoon PVI: gender (OR = 0.95 per year; p = 0.01); LAV (OR = 1.3/10mL; p = 0.02) and LAVI (OR = 1.58/10 mL/m2; p = 0.02). In all models, PLAX and area measurements were not predictive. CONCLUSIONS: Our data add further to evidence that LA size lends itself well as a predictor of PVI outcome. LAVI and LAV were independently predictive of rhythm outcome after PVI. This did not hold true for more commonly used measurements, such as PLAX diameter and surfaces of the LA, irrespective of the view chosen.

5.
J Electrocardiol ; 67: 89-93, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34091368

RESUMEN

AIMS: The present study aims at analyzing the role of a preimplantation 12-lead electrocardiogram (ECG) on the prediction of inappropriate S-ICD® episodes. METHODS: N=116 screened patients (pts) with an S-ICD® and a follow-up of at least 6 months were included. A preimplantation 12-lead ECG (50 mm/s, 10 mm/mV) was analyzed with regard to QRS and T-wave amplitude, T wave concordance or discordance and QRS/T wave ratio in all 12 leads. To ensure an exact determination of parameters Datinf® Measure software was used. Results were correlated to the occurrence of oversensing of cardiac signals during follow-up. RESULTS: N = 116 pts. (63,8% male, mean age 40,9 ± 15,5 years) were included (primary prevention in 47.4% of pts). The most frequent cardiac diseases were hypertrophic cardiomyopathy (HCM) in n = 25 (21,6%), electrical heart disease in n = 20 (17,2%), and dilated cardiomyopathy in n = 17 (14,7%). Mean follow-up was 740 ± 549 days. During follow- up n = 17 (14.7%) pts. experienced n = 27 inappropriate episodes due to T-wave oversensing. Besides HCM (OR 6.16, CI 1.79-21.15, p = 0.004) a discordance of QRS to T-wave in lead I (OR 6.5, CI 1.86-22.67, p = 0.003) was found to be a strong predictor for inappropriate shocks. In multivariate analysis the pts. with a combination of both had an 8.4-fold higher risk of misclassification of intracardiac signals (p = 0.003) with consecutive inappropriate therapy. CONCLUSION: A discordance of QRS to T-wave in lead I turned out to be a strong predictor for future inappropriate shocks in a typical S-ICD® cohort with special impact on HCM pts.


Asunto(s)
Cardiomiopatía Dilatada , Cardiomiopatía Hipertrófica , Desfibriladores Implantables , Cardiopatías , Adulto , Arritmias Cardíacas , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad
6.
Clin Res Cardiol ; 110(6): 905-912, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33961097

RESUMEN

INTRODUCTION: Supraventricular tachycardias (SVT) are often difficult to document due to their intermittent, short-lasting nature. Smartphone-based one-lead ECG monitors (sECG) were initially developed for the diagnosis of atrial fibrillation. No data have been published regarding their potential role in differentiating inappropiate sinus tachycardia (IST) from regular SVT. If cardiologists could distinguish IST from SVT in sECG, economic health care burden might be significantly reduced. METHODS: We prospectively recruited 75 consecutive patients with known SVT undergoing an EP study. In all patients, four ECG were recorded: a sECG during SVT and during sinus tachycardia and respective 12-lead ECG. Two experienced electrophysiologists were blinded to the diagnoses and separately evaluated all ECG. RESULTS: Three hundred individual ECG were recorded in 75 patients (47 female, age 50 ± 18 years, BMI 26 ± 5 kg/m2, 60 AVNRT, 15 AVRT). The electrophysiologists' blinded interpretation of sECG recordings showed a sensitivity of 89% and a specificity of 91% for the detection of SVT (interobserver agreement κ = 0.76). In high-quality sECG recordings (68%), sensitivity rose to 95% with a specificity of 92% (interobserver agreement of κ = 0.91). Specificity increased to 96% when both electrophysiologists agreed on the diagnosis. Respective 12-lead ECG had a sensitivity of 100% and specificity of 98% for the detection of SVT. CONCLUSION: A smartphone-based one-lead ECG monitor allows for differentiation of SVT from IST in about 90% of cases. These results should encourage cardiologists to integrate wearables into clinical practice, possibly reducing time to definitive diagnosis of an arrhythmia and unnecessary EP procedures. A smartphone-based one lead ECG device (panel A) can be used reliably to differentiate supraventricular tachycardia (panel B) from inappropriate sinus tachycardia when compared to a simultaneously conducted gold-standard electrophysiology study (panels C, D).


Asunto(s)
Electrocardiografía/métodos , Teléfono Inteligente , Taquicardia Supraventricular/diagnóstico , Diagnóstico Diferencial , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/fisiopatología , Taquicardia Supraventricular/fisiopatología
7.
Heart Rhythm ; 18(9): 1539-1547, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33957319

RESUMEN

BACKGROUND: Cardiac sarcoidosis (CS) with right ventricular (RV) involvement can mimic arrhythmogenic right ventricular cardiomyopathy (ARVC). Histopathological differences may result in disease-specific RV activation patterns detectable on the 12-lead electrocardiogram. Dominant subepicardial scar in ARVC leads to delayed activation of areas with reduced voltages, translating into terminal activation delay and occasionally (epsilon) waves with a small amplitude. Conversely, patchy transmural RV scar in CS may lead to conduction block and therefore late activated areas with preserved voltages reflected as preserved R' waves. OBJECTIVE: The purpose of this study was to evaluate the distinct terminal activation patterns in precordial leads V1 through V3 as a discriminator between CS and ARVC. METHODS: Thirteen patients with CS affecting the RV and 23 patients with gene-positive ARVC referred for ventricular tachycardia ablation were retrospectively included in a multicenter approach. A non-ventricular-paced 12-lead surface electrocardiogram was analyzed for the presence and the surface area of the R' wave (any positive deflection from baseline after an S wave) in leads V1 through V3. RESULTS: An R' wave in leads V1 through V3 was present in all patients with CS compared to 11 (48%) patients with ARVC (P = .002). An algorithm including a PR interval of ≥220 ms, the presence of an R' wave, and the surface area of the maximum R' wave in leads V1 through V3 of ≥1.65 mm2 had 85% sensitivity and 96% specificity for diagnosing CS, validated in a second cohort (18 CS and 40 ARVC) with 83% sensitivity and 88% specificity. CONCLUSION: An easily applicable algorithm including PR prolongation and the surface area of the maximum R' wave in leads V1 through V3 of ≥1.65 mm2 distinguishes CS from ARVC. This QRS terminal activation in precordial leads V1 through V3 may reflect disease-specific scar patterns.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/complicaciones , Cardiomiopatías/diagnóstico , Electrocardiografía , Sarcoidosis/diagnóstico , Taquicardia Ventricular/complicaciones , Adulto , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Cardiomiopatías/complicaciones , Cardiomiopatías/fisiopatología , Diagnóstico Diferencial , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sarcoidosis/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología
8.
Herzschrittmacherther Elektrophysiol ; 32(2): 186-198, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34032905

RESUMEN

Arrhythmogenic cardiomyopathy (AC) is a rare heart muscle disease with a genetic background and autosomal dominant mode of transmission. The clinical manifestation is characterized by ventricular arrhythmias (VA), heart failure (HF) and the risk of sudden cardiac death (SCD). Pregnancy in young female patients with AC represents a challenging condition for the life and family planning of young affected women. In addition to genetic mechanisms that influence the complex pathophysiology of AC, experimental and clinical data have confirmed the pathogenetic role of strenuous exercise and competitive sports in the early onset and rapid progression of AC symptoms and complications. Pregnancy and exercise share a number of physiological aspects of adaptation. In AC, both result in ventricular volume overload and myocardial stretch. Therefore, pregnancy has been postulated as a potential risk factor for HF, VA, SCD, and pregnancy-related obstetric complications in patients with AC. However, the available evidence on pregnancy in AC does not confirm this hypothesis. In most women with AC, pregnancies are well tolerated, uneventful, and follow a benign course. Pregnancy-related symptoms (VA, syncope, HF) and mortality, as well as obstetric complications, are uncommon in AC patients and range in the order of background populations and cohorts with AC and no pregnancy. The number of completed pregnancies is not associated with an acceleration of AC pathology or an increased risk of VA or HF during pregnancy and follow-up. Accordingly, there is no medical indication to advise against pregnancy in patients with AC. Preconditions include stability of rhythm and hemodynamics at baseline, as well as clinical follow-ups and the availability of multidisciplinary expert consultation during pregnancy and postpartum. Genetic counseling is recommended prior to pregnancy for all couples and their families affected by AC.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Cardiomiopatías , Arritmias Cardíacas , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/genética , Muerte Súbita Cardíaca/prevención & control , Femenino , Humanos , Embarazo , Factores de Riesgo
9.
Int Heart J ; 62(1): 72-77, 2021 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-33455989

RESUMEN

Atrioventricular nodal reentry tachycardia (AVNRT) is the most common regular supraventricular tachycardia (SVT). Slow pathway modification (SPM) is the accepted first line treatment with reported success rates around 95%. Information regarding possible predictors of AVNRT recurrence is scarce.Out of 4170 consecutive patients with SPM in our department from 1993-2018, we identified 78 patients (1.9%) receiving > 1 SPM (69% female, median age 50 years) with a recurrence of AVNRT after a successful SPM. We matched these patients for age, gender and number of radiofrequency applications during first SPM with 78 patients who received one successful SPM in our center without AVNRT recurrence. Both groups were analyzed for possible predictors of a recurrence of AVNRT during long-term follow-up. The recurrence group contained a significantly lower proportion of patients with an occurrence of junctional beats during SPM (69% versus 89%, P = 0.006). Moreover, significantly more cases of previously diagnosed atrial fibrillation/tachycardia (AF/AT; 21% versus 5%, P = 0.007) and inducible AF/AT during electrophysiology study (23% versus 6%, P = 0.006) were present in the recurrence group. While more than half of patients had a recurrence within the first year, in 20% symptoms reappeared ≥ 4 years after ablation.In a small percentage of patients, AVNRT recurs after an initially successful ablation. Interestingly, these patients had significantly fewer junctional beats during ablation and a higher rate of other (inducible) arrhythmias. AVNRT recurrence spanned a considerable timeframe and should remain a differential diagnosis, even years after ablation.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Fascículo Atrioventricular/cirugía , Ablación por Catéter/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Adulto , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Fascículo Atrioventricular/fisiopatología , Electrofisiología Cardíaca/métodos , Electrofisiología Cardíaca/estadística & datos numéricos , Estudios de Casos y Controles , Diagnóstico Diferencial , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia Supraventricular/clasificación , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento
10.
J Interv Card Electrophysiol ; 61(1): 55-62, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32458180

RESUMEN

BACKGROUND: The impact of structural heart disease (SHD) on safety and efficacy of catheter ablation of cavo-tricuspid isthmus-dependent atrial flutter (AFLU) is unclear. In addition, recent data suggest a higher complication rate of AFLU ablation compared to the more complex atrial fibrillation (AF) ablation procedure. METHODS AND RESULTS: Within our prospective multicenter registry, 3526 consecutive patients underwent AFLU ablation at 49 German electrophysiological centers from 2007 to 2010. For the present analysis, the patients were divided into a group with SHD (n = 2164 [61.4%]; median age 69 years; 78.5% male) and a group without SHD (n = 1362 [38.6%]; 65 years; 70.3% male). In our study, SHD mainly encompasses coronary artery disease (52.6%), left ventricular ejection fraction ≤ 50% (47.6%), and hypertensive heart disease (28.0%). The primary ablation success (97%) and the incidence of major (0.2%) or moderate (1.2%) complications did not differ significantly between the two groups (P = 1.0 and 0.87, respectively). Vascular access site complications (0.6%), AV block III° (0.2%), and bleeding (≥ BARC II: 0.2%) were most common. After a median 562 days of follow-up, we observed a 2.92-fold higher one-year mortality (P < 0.0001) in patients with SHD. Patients' satisfaction with the ablation therapy (72.0% satisfied) was close to the overall subjective tachyarrhythmia-free rate (70.7%). CONCLUSIONS: The present analysis demonstrates that ablation of cavo-tricuspid isthmus dependent AFLU in patients with SHD has a comparable, excellent risk-benefit profile in our large "real-world" registry. Mortality rates expectedly are higher in patients with SHD and AFLU compared to patients without SHD. CLINICALTRIALS.GOV: NCT01197638, http://clinicaltrials.gov/ct2/show/NCT01197638.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Cardiopatías , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Femenino , Humanos , Recién Nacido , Masculino , Estudios Prospectivos , Sistema de Registros , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
11.
J Cardiol ; 77(2): 154-159, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32917454

RESUMEN

Sarcoidosis is a multisystem granulomatous disease of unknown etiology characterized by noncaseating granulomas. Cardiac involvement is often limiting patients' prognosis. Cardiac sarcoidosis can manifest with variant cardiac arrhythmias, of which atrioventricular (AV)-block-related bradycardia and ventricular tachycardias are the most common. Although cardiac sarcoidosis remains a histopathological diagnosis, the significance of imaging modalities, especially cardiac magnetic resonance imaging is increasing rapidly but mainly remains reserved for patients with a high suspicion due to a previous arrhythmia or unknown cardiomyopathy. Thus, there is a need for screening in daily clinical practice so that possible characteristic electrocardiographic (ECG) findings may guide the way to detect the disease. We therefore evaluated the ECG as a potential tool for screening of cardiac sarcoidosis and present different electrophysiological manifestations of cardiac sarcoidosis based on a literature review. The ECG is a valuable tool for screening of cardiac involvement in patients with sarcoidosis. Several parameters have been shown to be associated with cardiac involvement in sarcoidosis such as higher-degree AV-block, QRS complex fragmentation and widening, as well as certain T wave abnormalities that may indicate cardiac involvement, of which the latter two are most promising and specific. However, prospective studies examining a large number of trials are desirable.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Electrocardiografía/métodos , Sarcoidosis/diagnóstico por imagen , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/etiología , Bloqueo Atrioventricular/diagnóstico por imagen , Bloqueo Atrioventricular/etiología , Cardiomiopatías/complicaciones , Diagnóstico Diferencial , Humanos , Estudios Prospectivos , Sarcoidosis/complicaciones
12.
Clin Cardiol ; 43(12): 1579-1584, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33073878

RESUMEN

BACKGROUND: The role and technique of catheter ablation of atrial fibrillation (AF) in the elderly is unclear. While in young patients pulmonary vein isolation (PVI) has evolved as first option, in older patients decision is often made in favor of drugs as higher complication rates and less benefit are suspected. Therefore, data on PVI of paroxysmal and persistent AF in these patients is still sparse but of eminent importance. HYPOTHESIS: PVI is comparably safe in the very elderly with similar recurrence and complication rates. METHODS: We enrolled all patients (n = 146) aged >75 years who underwent a first PVI over a period of 10 years (2009-2019) from our prospective single-center ablation registry. Mean follow-up time was 231 ± 399 days. RESULTS: Acute ablation success defined as complete PVI and sinus rhythm at the end of the ablation procedure was high (99%). Severe periprocedural complications occurred in 3.3% (stroke/TIA n = 2; 1.3%; pericardial effusion n = 3; 2%). In 4.6% of patients symptomatic sick-sinus-syndrome was unmasked after PVI resulting in pacemaker implantation. There were no deaths related to PVI. Recurrence rate of symptomatic AF was 37.3% resulting in a Re-PVI and/or substrate ablation in 32 pts (20.9%). During follow-up pacemaker implantation plus atrioventricular node ablation was performed in 10 pts (6.8%). There was a trend toward lower recurrence rates with single-shot devices (cryoballoon, multielectrode phased-radiofrequency ablation catheter) than with point-by-point radiofrequency while complication rates did not differ. CONCLUSION: PVI for AF is a feasible treatment option also in patients >75 years with a reasonable success and safety profile. Higher success rates occurred in patients treated with a single-shot device as compared to point-by-point ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Registros , Taquicardia Paroxística/cirugía , Factores de Edad , Anciano , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Recurrencia , Taquicardia Paroxística/fisiopatología , Resultado del Tratamiento
13.
Clin Cardiol ; 43(12): 1423-1427, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32865252

RESUMEN

BACKGROUND: Ablation emerged as first line therapy in the treatment of various arrhythmias. Nevertheless, in older patients (pts), decision is often made pro drug treatment as more complications and less benefit are suspected. HYPOTHESIS: We hypothesized that different kind of ablations can be performed safely regardless of the pts age. METHODS: We enrolled all pts aged >80 years (yrs) who underwent ablation for three different arrhythmias (atrial flutter [AFL], atrioventricular nodal re-entry tachycardia [AVNRT], ventricular tachycardia [VT]) between August 2002 and December 2018. Procedural data and outcome were compared with matched groups aged 60 to 80 years and 40 to 60 years, respectively. Periprocedural and in-hospital complications were analyzed. RESULTS: The analysis included 1191 patients (397 pts per group: 63% AFL, 23% AVNRT, 14% VT) who underwent ablation. Acute success was high in all types of arrhythmias irrespective of age (>80, 60-80, 40-60 years: AFL 97%/98%/98%, AVNRT 97%/95%/97%, VT 82%/86%/93%). Rate of periprocedural complications were similar in all groups treated for AFL and AVNRT. For VT ablations significant differences were noted between pts > 80 or 60 to 80 years and those aged 40-60 years (16.1%/14.3%/3.6%). Most complications were infections and groin haematoma. No strokes, iatrogenic atrioventricular blocks and deaths related to the ablation occurred. CONCLUSION: Ablation appears safe in pts > 80 years. Success rates were comparable to matched younger cohorts. A significant difference was observed for VT patients.


Asunto(s)
Arritmias Cardíacas/cirugía , Ablación por Catéter/métodos , Electrocardiografía , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento
14.
Cardiology ; 145(10): 676-681, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32854099

RESUMEN

INTRODUCTION: Periprocedural oral anticoagulation (OAC) strategies for atrial fibrillation (AF) ablation procedures are changing rapidly. OBJECTIVE: To assess the management and course of periprocedural OAC for AF ablation procedures in experienced electrophysiology (EP) centers in Germany over the last 12 months. METHODS: The data are based on an electronic questionnaire, which was sent to 35 experienced EP centers in September 2018 and then exactly 1 year later. Participants provided information on their periprocedural OAC management, the handling with dual therapy (OAC plus single antiplatelet therapy), the availability of specific antidotes, the transseptal puncture approach, and noteworthy complications. RESULTS: Responses were received from all 35 centers and represent 10,010 AF ablation procedures annually. In 2018, the administration of vitamin K antagonist (VKA) was continued throughout the procedure at all centers (100%). In contrast, the majority of centers used minimally interrupted periprocedural non-vitamin K antagonist oral anticoagulants (NOAC) (54.3%), 13 centers (37.2%) completely interrupted NOAC, and only 3 centers (8.5%) continued NOAC throughout the procedure. At the 1-year follow-up survey, 32 centers were found to have continued their previous strategy of periprocedural OAC and 3 changed from a minimally interrupted to a continued NOAC strategy. Of note, 30 centers (85.7%) performed transseptal puncture fluoroscopically without additional cardiac imaging. In the setting of uninterrupted periprocedural OAC management, no relevant complications were noted. CONCLUSION: Our survey shows marked heterogeneous periprocedural OAC management at experienced EP centers in Germany. Whereas continuation of VKA has already been integrated into clinical practice, the majority of centers still use a minimally interrupted NOAC strategy.


Asunto(s)
Anticoagulantes , Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Administración Oral , Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Alemania , Heparina de Bajo-Peso-Molecular , Humanos , Accidente Cerebrovascular/tratamiento farmacológico , Encuestas y Cuestionarios
15.
Sci Rep ; 10(1): 12133, 2020 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-32699382

RESUMEN

There is conflicting evidence regarding the impact of propofol on cardiac repolarization and the risk of torsade de pointes (TdP). The purpose of this study was to elucidate the risk of propofol-induced TdP and to investigate the impact of propofol in drug-induced long QT syndrome. 35 rabbit hearts were perfused employing a Langendorff-setup. 10 hearts were perfused with increasing concentrations of propofol (50, 75, 100 µM). Propofol abbreviated action potential duration (APD90) in a concentration-dependent manner without altering spatial dispersion of repolarization (SDR). Consequently, no proarrhythmic effects of propofol were observed. In 12 further hearts, erythromycin was employed to induce prolongation of cardiac repolarization. Erythromycin led to an amplification of SDR and triggered 36 episodes of TdP. Additional infusion of propofol abbreviated repolarization and reduced SDR. No episodes of TdP were observed with propofol. Similarly, ondansetron prolonged cardiac repolarization in another 13 hearts. SDR was increased and 36 episodes of TdP occurred. With additional propofol infusion, repolarization was abbreviated, SDR reduced and triggered activity abolished. In this experimental whole-heart study, propofol abbreviated repolarization without triggering TdP. On the contrary, propofol reversed prolongation of repolarization caused by erythromycin or ondansetron, reduced SDR and thereby eliminated drug-induced TdP.


Asunto(s)
Corazón/efectos de los fármacos , Propofol/toxicidad , Torsades de Pointes/etiología , Potenciales de Acción/efectos de los fármacos , Animales , Modelos Animales de Enfermedad , Electrocardiografía , Eritromicina/farmacología , Corazón/fisiología , Ventrículos Cardíacos/efectos de los fármacos , Ventrículos Cardíacos/fisiopatología , Conejos , Riesgo , Torsades de Pointes/inducido químicamente
16.
Clin Res Cardiol ; 109(10): 1282-1291, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32157380

RESUMEN

BACKGROUND: Outcome of ischemic VT ablation may differ between patients with previous myocardial infarction (MI) in relation to infarct localization. METHODS: We analyzed procedural data, acute and long-term outcomes of 152 consecutive patients (139 men, mean age 67 ± 9 years) with previous anterior or inferior MI who underwent ischemic VT ablation at our institution between January 2010 and October 2015. RESULTS: More patients had a history of inferior MI (58%). Mean ejection fraction was significantly lower in anterior MI patients (28 ± 10% vs. 34 ± 10%, p < 0.001). NYHA class and presence of comorbidities were not different between the groups. Indication for the procedure was electrical storm in 43% of patients, and frequent implantable cardioverter defibrillator (ICD) therapies in 57%, and did not differ significantly between anterior and inferior MI patients. A mean of 3 ± 2 VT morphologies were inducible, with a trend towards more VT in the anterior MI group (3.1 ± 2.2 vs. 2.6 ± 1.9, p = 0.18). Procedural parameters and acute success did not differ between the groups. During a mean follow-up of 3 ± 2 years, more anterior MI patients had undergone a re-ablation (49% vs. 33%, p = 0.09, Chi-square test). There was a trend towards more ICD shocks in patients with previous anterior MI (46% vs. 34%). After adjusting for risk factors and ejection fraction, multivariable Cox regression analyses showed no significant difference in mortality (p = 0.78) and cardiovascular mortality between infarct localizations (p = 0.6). CONCLUSION: Clinical characteristics of patients with anterior and inferior MI are similar except for ejection fraction. Patients with inferior MI appear to have better outcome regarding survival, ICD shocks and re-ablation, but this appears to be related to better ejection fraction when compared with anterior MI.


Asunto(s)
Infarto de la Pared Anterior del Miocardio/complicaciones , Ablación por Catéter/métodos , Infarto de la Pared Inferior del Miocardio/complicaciones , Taquicardia Ventricular/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico/fisiología , Resultado del Tratamiento
18.
Cardiovasc Toxicol ; 20(2): 168-175, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31302839

RESUMEN

Several studies suggest QT prolongation and torsade de pointes with acetylcholine-esterase inhibitors. We therefore examined the electrophysiologic profile of donepezil, rivastigmine, and galantamine in a sensitive whole-heart model of proarrhythmia. 34 rabbit hearts were isolated and retrogradely perfused employing the Langendorff setup. Hearts were treated either with donepezil, rivastigmine, or galantamine in rising concentrations and electrophysiologic studies were performed. In the presence of donepezil and galantamine, spatial dispersion of repolarization was amplified. Cardiac repolarization (QT interval and action potential duration) was prolonged with donepezil but not with galantamine. Remarkably, both drugs induced triggered activity (early afterdepolarizations and torsade de pointes tachycardia). Despite a pronounced prolongation of repolarization with rivastigmine, no increase in spatial dispersion of repolarization and thus no triggered activity was observed. In the present study, donepezil and galantamine provoked triggered activity, whereas rivastigmine did not have proarrhythmic effects. Spatial dispersion of repolarization but not duration of cardiac repolarization was associated with increased risk of drug-induced proarrhythmia with acetylcholine-esterase inhibitors. Consequently, QT interval duration might be insufficient to estimate the risk of proarrhythmia with acetylcholine-esterase inhibitors. Our findings emphasize the need for further electrocardiographic risk predictors.


Asunto(s)
Arritmias Cardíacas/inducido químicamente , Inhibidores de la Colinesterasa/toxicidad , Donepezilo/toxicidad , Galantamina/toxicidad , Sistema de Conducción Cardíaco/efectos de los fármacos , Frecuencia Cardíaca/efectos de los fármacos , Rivastigmina/toxicidad , Potenciales de Acción/efectos de los fármacos , Animales , Arritmias Cardíacas/fisiopatología , Cardiotoxicidad , Sistema de Conducción Cardíaco/fisiopatología , Preparación de Corazón Aislado , Conejos , Periodo Refractario Electrofisiológico/efectos de los fármacos , Medición de Riesgo , Factores de Tiempo
19.
Eur J Intern Med ; 73: 72-75, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31806411

RESUMEN

INTRODUCTION: The AliveCor Kardia ECG monitor (ACK) offers a smartphone-based one-lead ECG recording for the detection of atrial fibrillation. We compared ACK lead I recordings with the 12-lead ECG and introduce a novel parasternal lead (NPL). METHODS: Consecutive cardiac inpatients were recruited. In all patients a 12-lead ECG, ACK lead I and NPL were obtained. Two experienced electrophysiologists were blinded and separately evaluated all ECG. We calculated sensitivity, specificity, and predictive values of the ACK ECG compared to the 12-lead ECG. RESULTS: 296 ECG from 99 patients (38 female, age 64 ± 15 years, BMI 27.8 ± 5.1 kg/m2) were analyzed. 20% of ACK lead I recordings contained a critical amount of artifact. The electrophysiologists' interpretation of the ACK recordings yielded a sensitivity of 100% and specificity of 94% for atrial fibrillation or flutter in lead I (κ = 0.90) and a sensitivity of 96% and specificity of 97% in the NPL (κ = 0.92). The ACK diagnostic algorithm displayed a significantly lower sensitivity (55-70%), specificity (60-69%), and accuracy (κ = 0.4-0.53) but a high negative predictive value (100%). Patients with atrial flutter (n = 5) and with ventricular stimulation (n = 12) had a high likelihood of being misclassified by the algorithm. CONCLUSION: The AliveCor Kardia ECG monitor allows a highly accurate detection of atrial fibrillation by an interpreting electrophysiologist both in the standard lead I and a novel parasternal lead. The diagnostic algorithm offered by the system may be useful in screening recordings for further review. Diagnostic challenges present in atrial flutter and ventricular pacemaker stimulation.


Asunto(s)
Fibrilación Atrial , Aplicaciones Móviles , Anciano , Fibrilación Atrial/diagnóstico , Electrocardiografía , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Teléfono Inteligente
20.
Heart Vessels ; 35(5): 699-704, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31705185

RESUMEN

Atrial fibrillation and other atrial tachyarrhythmias are increasing with age and concomitant morbidity. First options in symptomatic patients are drug treatment and catheter ablation. Nevertheless, a considerable number of patients suffer from refractory atrial tachyarrhythmias despite treatment. Atrioventricular node ablation (AVNA) may be helpful in many of these patients. Therefore, we investigated AVNA patients with a long-term follow-up. We enrolled 82 patients with a follow-up longer than 1 year receiving AVNA for drug- and ablation-resistant atrial tachyarrhythmias (AA) in a retrospective manner. Mean follow-up duration was 48 ± 24 months. 50% of the patients initially received AVNA to optimize biventricular pacing in cardiac resynchronization therapy, the other 50% because of refractory symptomatic tachyarrhythmias. Persistent AV block was achieved in every patient. Symptom relief and patient satisfaction were high during follow-up. Due to system upgrades there were 63% of patients with a biventricular system during follow-up. In these patients, left-ventricular ejection fraction (LV-EF) increased by 7% (42-49%) after ablation. AVNA is effective in increasing biventricular pacing as well as for symptom relief in patients with refractory atrial tachyarrhythmias. AVNA should be considered as a valuable option in patients with refractory atrial tachyarrhythmias lacking other treatment options.


Asunto(s)
Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Ablación por Catéter , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Nodo Atrioventricular/fisiopatología , Ablación por Catéter/efectos adversos , Bases de Datos Factuales , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Recuperación de la Función , Estudios Retrospectivos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...