Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594705

RESUMEN

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Diseño de Prótesis , Válvula Aórtica/cirugía , Resultado del Tratamiento
3.
Antibiotics (Basel) ; 12(7)2023 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-37508278

RESUMEN

In our hospital, adherence to the guidelines for peri-operative antimicrobial prophylaxis (PAP) is suboptimal, with overly long courses being common. This practice does not offer any incremental benefit, and it only adds to the burden of antimicrobial consumption, promotes the emergence of antimicrobial resistance, and it is associated with adverse events. Our objective was to study the effect of an electronic reminder on the adherence to each element of PAP after cardiac surgery. We conducted a single center, before and after intervention, prospective cohort study from 1 June 2014 to 30 September 2017. The intervention consisted of a reminder of the hospital guidelines when ordering PAP through the hospital information system. The primary outcome was adherence to the suggested duration of PAP, while secondary outcomes included adherence to the other elements of PAP and incidence of surgical site infections (SSI). We have studied 1080 operations (400 pre-intervention and 680 post-intervention). Adherence to the appropriate duration of PAP increased significantly after the intervention [PRE 4.0% (16/399) vs. POST 15.4% (105/680), chi-square p < 0.001]; however, it remained inappropriately low. Factors associated with inappropriate duration of PAP were pre-operative hospitalization for <3 days, and duration of operation >4 h, while there were significant differences between the chief surgeons. Unexpectedly, the rate of SSIs increased significantly during the study (PRE 2.8% (11/400) vs. POST 5.9% (40/680), chi-square p < 0.019). The implemented intervention achieved a relative increase in adherence to the guideline-recommended PAP duration; however, adherence was still unacceptably low and further efforts to improve adherence are needed.

5.
Semin Thorac Cardiovasc Surg ; 34(1): 123-132, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33460764

RESUMEN

The impairment of intracellular calcium homeostasis plays an essential role during ischemia-reperfusion injury. Calcium release from sarcoplasmic reticulum which is triggered by myocardial ischemia is mainly mediated by ryanodine receptors. Dantrolene sodium is a ryanodine receptor antagonist. The objective of the present study was to evaluate the in-vivo impact of dantrolene sodium on myocardial ischemia-reperfusion injury in swine models. An in vivo, experimental trial comparing 10 experimental animals which received dantrolene sodium with 9 control swine models was conducted. Their left anterior descending coronary artery was temporarily occluded for 75 minutes via a vessel tourniquet, which was then released. Myocardial reperfusion was allowed for 24 hours. Dantrolene was administered at the onset of the reperfusion period and levels of troponin, creatine phosphokinase and creatine kinase myocardial band between the two groups were compared. Additionally, various other hemodynamic parameters and left ventricular morphology and function were examined. There were significantly lower values of troponin, creatine phosphokinase and creatine kinase myocardial band in the dantrolene group indicating less ischemia-reperfusion injury. Moreover, the postischemic cardiac index was also greater in the dantrolene group, whereas viable myocardium was also better preserved. In conclusion, the in vivo cardioprotective role of dantrolene sodium against ischemia-reperfusion injury in swine models was indicated in this study. Therefore, dantrolene sodium administration could be a promising treatment against ischemia-reperfusion injury in humans. However, large randomized clinical studies should be firstly carried out to prove this hypothesis.


Asunto(s)
Isquemia Miocárdica , Daño por Reperfusión Miocárdica , Animales , Calcio/metabolismo , Creatina Quinasa/metabolismo , Dantroleno/farmacología , Dantroleno/uso terapéutico , Homeostasis , Daño por Reperfusión Miocárdica/prevención & control , Miocardio/metabolismo , Rianodina , Canal Liberador de Calcio Receptor de Rianodina , Porcinos , Resultado del Tratamiento , Troponina
6.
Indian J Thorac Cardiovasc Surg ; 37(5): 584-587, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34511770

RESUMEN

Hybrid arch replacement is a well-accepted method for the treatment of lesions involving the aortic arch, though its benefits compared to classic surgical techniques remain controversial. Multiple surgical approaches have been analyzed in the literature for the treatment of such a challenging pathology. In this case report, we describe the surgical management of a 72-year-old man presenting with a complicated aortic arch rupture. The patient was treated urgently with a type I hybrid arch replacement in two stages, with total preservation of cerebral and systemic perfusion. Our case shows that hybrid arch methods are applicable even in emergency cases.

7.
J Cardiovasc Surg (Torino) ; 62(6): 625-631, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34014059

RESUMEN

Aortic valve replacement is the treatment of choice concerning aortic valve disease. Excellent short- and long-term clinical results are reported. Patients referred for aortic valve replacement are getting older and older, so bioprosthetic valves play a more central role worldwide. However, patient comorbidities are also increased more often rendering patients unsuitable for open conventional aortic valve replacement. As a result, transcatheter aortic valve implantation has become the treatment of choice in patients at very high surgical risk. However, the percutaneous technique is related to major disadvantages provided that the diseased native valve is left in place. Its durability is also uncertain. More recently, sutureless Perceval S valve bioprosthesis has gained ground in the field of aortic stenosis therapy filling the gap between conventional aortic valve replacement and transcatheter approach. Excellent hemodynamic and clinical results are reported. Its deployment is performed under direct view and ischemic and overall operative times are significantly decreased. Five-year follow-up results are also optimal. However, the "Achilles' heel" of sutureless technology is increased rates of postoperative permanent pacemaker implantation requirement compared to conventional approach. The incidence of this complication varies in literature. Patient-related factors such as preoperative conduction disorders, older age and short membranous septum are predictors of postoperative pacemaker requirement. However, several technical modifications regarding manufacturer recommendations can be adopted to mitigate this complication. Appropriate annular decalcification, higher guiding sutures placement, reduced balloon pressure and duration and avoiding of oversizing can contribute to prevent from this complication.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Arritmias Cardíacas/prevención & control , Bioprótesis , Prótesis Valvulares Cardíacas , Procedimientos Quirúrgicos sin Sutura , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Hemodinámica , Humanos , Marcapaso Artificial , Diseño de Prótesis , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Ann Card Anaesth ; 24(2): 247-249, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33884987

RESUMEN

Coronary artery bypass grafting is the mainstay of revascularization worldwide. However, the most widely used saphenous vein grafts are related to a number of late sequelae. Aortocoronary saphenous vein graft aneurysms mainly diagnosed incidentally are one of these complications. Although rare, given the fatal risk of rupture if left untreated, management either with percutaneous intervention or open redo surgery should be considered. However, no guidelines are established in current scarce literature. Hereby, we present the successful percutaneous management of a huge saphenous vein graft aneurysm via coiling, avoiding the risks of repeat sternotomy.


Asunto(s)
Aneurisma de la Aorta , Vena Safena , Aorta Torácica , Puente de Arteria Coronaria , Errores Diagnósticos , Humanos , Vena Safena/diagnóstico por imagen
9.
Am J Case Rep ; 21: e925931, 2020 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-32980852

RESUMEN

BACKGROUND The worldwide spread of the severe acute respiratory syndrome-coronavirus-2 (SARS-COV-2) has created unprecedented situations for healthcare professionals and healthcare systems. Although infection with this virus is considered the main health problem currently, other diseases are still prevalent. CASE REPORT This report describes a 59-year-old man who presented with symptoms of dyspnea and fever that were attributed to Covid-19 infection. His clinical condition deteriorated and further examinations revealed a subjacent severe aortic regurgitation due to acute infective endocarditis. Surgical treatment was successful. CONCLUSIONS The results of diagnostic tests for Covid-19 should be re-evaluated whenever there are clinical mismatches or doubts, as false-positive Covid-19 test results can occur. Clinical interpretation should not be determined exclusively by the Covid-19 pandemic. This case report highlights the importance of using validated and approved serological and molecular testing to detect infection with SARS-CoV-2, and to repeat tests when there is doubt about presenting symptoms.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Diagnóstico Tardío , Endocarditis/complicaciones , Endocarditis/diagnóstico , Neumonía Viral/diagnóstico , Anticuerpos Antivirales/análisis , Insuficiencia de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/diagnóstico , COVID-19 , Prueba de COVID-19 , Procedimientos Quirúrgicos Cardíacos/métodos , Infecciones por Coronavirus/complicaciones , Enfermedad Crítica , Progresión de la Enfermedad , Disnea/diagnóstico , Disnea/etiología , Endocarditis/virología , Reacciones Falso Positivas , Fiebre/diagnóstico , Fiebre/etiología , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/complicaciones , Pronóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Medición de Riesgo , Resultado del Tratamiento
11.
In Vivo ; 34(3 Suppl): 1603-1611, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32503818

RESUMEN

The aim of this systematic review was to identify the challenges imposed on medical and surgical education by the COVID-19 pandemic, and the proposed innovations enabling the continuation of medical student and resident training. A systematic review on the MEDLINE and EMBASE databases was performed on April 18th, 2020, and yielded 1288 articles. Sixty-one of the included manuscripts were synthesized in a qualitative description focused on two major axes, "challenges" and "innovative solutions", and two minor axes, "mental health" and "medical students in the frontlines". Shortage of personal protective equipment, suspension of clinical clerkships and observerships and reduction in elective surgical cases unavoidably affect medical and surgical education. Interesting solutions involving the use of virtual learning, videoconferencing, social media and telemedicine could effectively tackle the sudden cease in medical education. Furthermore, trainee's mental health should be safeguarded, and medical students can be involved in the COVID-19 clinical treatment if needed.


Asunto(s)
Infecciones por Coronavirus , Educación Médica/organización & administración , Cirugía General/educación , Medicina Interna/educación , Pandemias , Neumonía Viral , Estudiantes de Medicina/psicología , COVID-19 , Infecciones por Coronavirus/prevención & control , Educación a Distancia , Evaluación Educacional , Fuerza Laboral en Salud/estadística & datos numéricos , Humanos , Internado y Residencia , Pandemias/prevención & control , Neumonía Viral/prevención & control , Equipos de Seguridad/provisión & distribución , Entrenamiento Simulado , Medios de Comunicación Sociales , Telemedicina , Realidad Virtual , Carga de Trabajo
12.
J Vasc Surg ; 69(4): 996-1002.e3, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30528410

RESUMEN

OBJECTIVE: The aim of the study was to present the results for patients with atherosclerotic aneurysm of the descending thoracic aorta (DTA) treated with a novel thoracic stent graft. METHODS: A single-center retrospective review of prospectively collected data was performed. We extracted demographic variables as well as atherosclerotic comorbidities and operation-related and imaging-related data from patients' medical records. We estimated technical success rate, in-hospital and 30-day mortality, and mortality at the end of follow-up as well as complication and reintervention rate in our study cohort. Follow-up computed tomography angiography was performed after 1 month and 6 months and yearly thereafter. RESULTS: A total of 30 patients (80% male; mean age, 73.7 ± 6.33 years) were treated with Ankura Thoracic Stent Graft (Lifetech, Shenzhen, China) for DTA aneurysm from February 2014 until June 2017. Technical success of the thoracic endovascular aortic repair (TEVAR) was 97% (29/30 patients). A surgical conduit was required in one patient; in three patients, we intentionally covered the left subclavian artery because of insufficient proximal landing zone. No aorta-related deaths were recorded during follow-up. During the early postoperative period, two patients (7%) with long DTA coverage developed paralysis or paraparesis, which immediately resolved after lumbar drainage. No renal complications requiring dialysis were observed. One patient (3%) developed postoperative pulmonary infection, whereas access site complications were 7%. Two symptomatic patients treated outside instructions for use (7%) developed early type IA endoleak and one patient (3%) developed type IB endoleak; type II endoleak was recorded in 3% of the study cohort. During the 30-day postoperative period, two patients died of non-TEVAR-related causes, one of gastrointestinal bleeding and the other of pulmonary infection. During a median follow-up of 31.7 (range, 38.4) months, two more patients also died of non-TEVAR-related causes, one of stroke from carotid artery disease and the other of motor vehicle trauma. In the rest of the cohort, no other adverse events were noted. CONCLUSIONS: This novel endograft showed early evidence of a safe, effective, and durable endoprosthesis for the treatment of DTA aneurysms.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Indian J Surg ; 80(1): 68-76, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29581688

RESUMEN

Essential Skills in the Management of Surgical Cases (ESMSC) is an international wet lab simulation course aimed at undergraduate students. It combines basic science workshops, case-based lectures and ex vivo skills modules, as well as in vivo dissections using a swine model. This study aims to evaluate the effectiveness of high-fidelity In Vivo Simulation-Based Learning for undergraduate level trainees. Also our goal was to compare the skill-based performance of final year students vs. more junior-level ones. Forty undergraduate delegates at clinical rotation level (male = 28, female = 12, mean age = 23.12, 22-24, SD = 0.69) attended this 2-day course in Athens. N = 1 (2.5 %) was year 3, N = 4 (10 %) were year 4, N = 23 (57.5 %) were year 5 and N = 12 (30 %) were year 6. N = 30 (75 %) came from Hellenic universities, N = 8 (20 %) from the UK and N = 2 (5 %) from Germany. N = 20 (50 %) attended the in vivo dissections module first, and then the ex vivo one (type A rotation), whereas N = 20 followed the reverse training sequence with the ex vivo dissection first, followed by the in vivo one (type B rotation). The mean global rating scores for type A rotation were better in both the in vivo by 0.10 (2.40 vs. 2.30) and ex vivo modules by 0.15 (2.85 vs. 2.70), though it did not reach statistical significance (p > 0.05). Furthermore, the mean improvement of performance, in the laparoscopic skills station for the type A rotation, was better compared to type B by 0.351 (2.00 vs. 1.65, p = 0.003). Year 6 students performed better in the laparoscopic station (2.00 vs. 1.75, p = 0.059), whereas years 3, 4 and 5 performed better in the in vivo (2.42 vs. 2.16, p = 0.157) as well as the ex vivo dissections (2.78 vs. 2.75, p = 0.832), though none of those comparisons reached statistical significance. Delegates seemed to appreciate and enjoy the in vivo dissections as reflected in the feedback (8.67/10, min = 6 and max = 10, SD = 1.79). Although medical students seem to appreciate in vivo dissections modules, currently, further evidence is needed to support their recommendation in the undergraduate level. Surgical skills should be part of the undergraduate curriculum to improve final year students' performance in the theatre.

14.
Cardiovasc J Afr ; 29(1): e6-e8, 2018 01 23.
Artículo en Inglés | MEDLINE | ID: mdl-29582882

RESUMEN

Adult cardiac surgery is associated with significant perioperative morbidity and mortality rates, mainly in elderly patients with co-morbidities. A series of postoperative complications may arise and delay the recovery of patients undergoing cardiac surgery. Such complications also increase the burden of resource use and may affect late survival rates. Neurological complications appear mainly as stroke of varying degrees, with impairment of mobility and ability of the patient. We describe a rare case of progressive paraparesis after on-pump coronary artery bypass grafting, and review its aetiology, diagnosis and management.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Síndrome de Guillain-Barré/etiología , Paraparesia/etiología , Compresión de la Médula Espinal/etiología , Isquemia de la Médula Espinal/etiología , Anciano , Edema Encefálico/etiología , Puente Cardiopulmonar/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Resultado Fatal , Síndrome de Guillain-Barré/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Paraparesia/diagnóstico por imagen , Posicionamiento del Paciente/efectos adversos , Choque Séptico/etiología , Compresión de la Médula Espinal/diagnóstico por imagen , Isquemia de la Médula Espinal/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento
16.
Ann Card Anaesth ; 20(Supplement): S70-S72, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28074827

RESUMEN

We would like to present in this paper a patient with severe aortic valve stenosis referred to our department for surgical aortic valve replacement. In this patient, it was intraoperatively detected an unexpected heavily calcified porcelain ascending aorta. We present the treatment options in this situation, the difficulties affronted intraoperatively, the significance of the preoperative chest computed tomography scan and the use of the Perceval S aortic valve as ideal bioprosthesis implantation. This is a self-expanding, self-anchoring, and sutureless valve with a wide indication in all patients requiring aortic bioprosthesis.


Asunto(s)
Aorta/cirugía , Válvula Aórtica/cirugía , Calcinosis/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Calcinosis/diagnóstico por imagen , Ecocardiografía , Humanos , Masculino , Radiografía Torácica
17.
J Surg Res ; 207: 164-173, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27979473

RESUMEN

BACKGROUND: The adverse effects of myocardial ischemia and reperfusion during cardiopulmonary bypass (CPB) have been thoroughly described. Lazaroid U-74389G, a 21 aminosteroid, has been shown to attenuate ischemia and reperfusion injury and improve recovery in a variety of experimental models. METHODS: Sixteen male swine were randomly divided in two groups. All animals underwent 45 min of ischemic cardioplegic arrest, with U-74389G addition to the standard cardioplegic solution, whereas controls underwent the same procedure without U-74389G. Creatine kinase-MB isoenzyme (CK-MB) and cardiac troponin T levels were measured immediately before CPB (time point 0), during the ischemic period (time point 1) and 30 (time point 2), 60 (time point 3), and 120 (time point 4) min after reperfusion. Myocardial biopsies were obtained at time points 0 and 4. RESULTS: CK-MB levels (in U/L) at time points 0-4 were 205 (186-235) versus 219 (196-269; P = 0.72), 215 (167-248) versus 253 (193-339; P = 0.23), 234 (198-255) versus 338 (249-441; P = 0.02), 244 (217-272) versus 354 (269-496; P = 0.01), and 285 (230-321) versus 439 (432-530; P < 0.01) in lazaroid-treated animals versus controls, respectively. Cardiac troponin T levels (in ng/L) at time points 0-4 were 58 (26-287) versus 237 (26-395; P = 0.72), 129 (61-405) versus 265 (145-525; P = 0.23), 261 (123-467) versus 474 (427-1604; P = 0.04), 417 (204-750) versus 841 (584-1818; P = 0.11), and 643 (353-1259) versus 1600 (1378-2313; P < 0.01), respectively. Necrosis grades at time point 4 were 0.0 (0.0-1.0) versus 1.5 (1.0-2.0; P < 0.01) in lazaroid-treated animals versus controls, respectively. CONCLUSIONS: The present study, in addition to reconfirming the well-described adverse effects of CPB, demonstrates the efficacy of the newer generation lazaroid U-74389G in alleviating these effects.


Asunto(s)
Cardiotónicos/uso terapéutico , Daño por Reperfusión Miocárdica/tratamiento farmacológico , Pregnatrienos/uso terapéutico , Animales , Biomarcadores/metabolismo , Biopsia , Masculino , Daño por Reperfusión Miocárdica/metabolismo , Daño por Reperfusión Miocárdica/patología , Miocardio/metabolismo , Miocardio/patología , Necrosis , Distribución Aleatoria , Porcinos , Resultado del Tratamiento
18.
J Cardiol ; 69(1): 46-56, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27727088

RESUMEN

A hybrid strategy, firstly performed in the 1990s, is a combination of tools available only in the catheterization laboratory with those available only in the operating room in order to minimize surgical morbidity and face with any cardiovascular lesion. The continuous evolution of stent technology along with the adoption of minimally invasive surgical approaches, make hybrid approaches an attractive alternative to standard surgical or transcatheter techniques for any given set of cardiovascular lesions. Examples include hybrid coronary revascularization, when an open surgical anastomosis of the left internal mammary artery to the left anterior descending coronary artery is performed along with stent implantation in non-left anterior descending coronary vessels, open heart valve surgery combined with percutaneous coronary interventions to coronary lesions, hybrid aortic arch debranching combined with endovascular grafting for thoracic aortic aneurysms, hybrid endocardial and epicardial atrial fibrillation procedures, and carotid artery stenting along with coronary artery bypass grafting. The cornerstone of success for all of these methods is the productive collaboration between cardiac surgeons and interventional cardiologists. The indications and patient selection of these procedures are still to be defined. However, high-risk patients have already been shown to benefit from hybrid approaches.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Enfermedades Cardiovasculares/cirugía , Terapia Combinada/métodos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Stents
19.
J Invest Surg ; 30(2): 71-77, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27611894

RESUMEN

BACKGROUND: Undergraduate Surgical Education is becoming an essential element in the training of the future generation of safe and efficient surgeons. Essential Skills in the Management of Surgical Cases (ESMSC), is an international, joint applied surgical science and simulation-based learning wet lab course. METHODS: We performed a review of the existing literature on the topic of undergraduate surgical education. Following that, we analyzed the feedback questionnaire received 480 from 2 recent series of ESMSC courses (May 2015, n = 49 and November 2015, n = 40), in order to evaluate European Union students' (UK, Germany, Greece) views on the ESMSC course, as well as on the undergraduate surgical education. Results Using a 10 point graded scale, the overall ESMSC concept was positively evaluated, with a mean score of 9.41 ± 0.72 (range: 8-10) and 8.94 ± 1.1 (range: 7-10). The majority of delegates from both series [9.86 ± 0.43 (range: 8-10) and 9.58 ± 0.91 (range: 6-10), respectively] believed that ESMSC should be incorporated in the undergraduate surgical curriculum. Comparison of responses from the UK to the Greek Medical Student, as well as the findings from the third and fourth year versus the fifth and sixth year Medical Students, revealed no statistically significant differences pertaining to any of the questions (p > 0.05). CONCLUSIONS: Current evidence in the literature supports the enhancement of surgical education through the systematic use of various modalities that provide Simulation-Based Training (SBT) hands-on experience, starting from the early undergraduate level. The findings of the present study are in agreement with these previous reports.


Asunto(s)
Curriculum , Educación de Pregrado en Medicina/métodos , Cirugía General/educación , Entrenamiento Simulado , Adulto , Femenino , Alemania , Grecia , Humanos , Masculino , Encuestas y Cuestionarios , Reino Unido , Adulto Joven
20.
Open Access Maced J Med Sci ; 4(4): 742-743, 2016 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-28028424

RESUMEN

Aortic valve replacement (AVR) in patients with a small aortic annulus is a challenging issue. The importance of prosthesis-patient mismatch (PPM) post aortic valve replacement (AVR) is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR) and the transcatheter valve implantation (TAVI).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...