Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int Urol Nephrol ; 49(1): 123-131, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27796695

RESUMEN

PURPOSE: Ultrasonography (US) is an inexpensive, noninvasive and easy imaging procedure to comment on the kidney disease. Data are limited about the relation between estimated glomerular filtration rate (e-GFR) and all 3 renal US parameters, including kidney length, parenchymal thickness and parenchymal echogenicity, in chronic kidney disease (CKD). In this study, we aimed to investigate the association between e-GFR and ultrasonographic CKD score calculated via these ultrasonographic parameters. METHODS: One hundred and twenty patients with stage 1-5 CKD were enrolled in this study. The glomerular filtration rate was estimated by the Chronic Kidney Disease Epidemiology Collaboration equation. US was performed by the same radiologist who was blinded to patients' histories and laboratory results. US parameters including kidney length, parenchymal thickness and parenchymal echogenicity were obtained from both kidneys. All 3 parameters were scored for each kidney, separately. The sum of the average scores of these parameters was used to calculate ultrasonographic CKD score. RESULTS: The mean age of patients was 63.34 ± 14.19 years. Mean kidney length, parenchymal thickness, ultrasonographic CKD score and median parenchymal echogenicity were found as 96.2 ± 12.3, 10.97 ± 2.59 mm, 6.28 ± 2.52 and 1.0 (0-3.5), respectively. e-GFR was positively correlated with kidney length (r = 0.343, p < 0.001), parenchymal thickness (r = 0.37, p < 0.001) and negatively correlated with CKD score (r = -0.587, p < 0.001) and parenchymal echogenicity (r = -0.683, p < 0.001). Receiver operating characteristic curve analysis for distinction of e-GFR lower than 60 mL/min showed that the ultrasonographic CKD score higher than 4.75 was the best parameter with the sensitivity of 81% and positive predictivity of 92% (AUC, 0.829; 95% CI, 0.74-0.92; p < 0.001). CONCLUSION: We found correlation between e-GFR and ultrasonographic CKD score via using all ultrasonographic parameters. Also, our study showed that ultrasonographic CKD score can be useful for distinction of CKD stage 3-5 from stage 1 and 2. We suggested that the ultrasonographic CKD score provided more objective data in the assessment of CKD.


Asunto(s)
Riñón/diagnóstico por imagen , Riñón/patología , Insuficiencia Renal Crónica/diagnóstico por imagen , Insuficiencia Renal Crónica/fisiopatología , Adulto , Anciano , Área Bajo la Curva , Femenino , Tasa de Filtración Glomerular , Humanos , Fallo Renal Crónico/diagnóstico por imagen , Fallo Renal Crónico/fisiopatología , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Valor Predictivo de las Pruebas , Curva ROC , Insuficiencia Renal Crónica/patología , Método Simple Ciego , Ultrasonografía
2.
Int Urol Nephrol ; 48(8): 1343-1348, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27118565

RESUMEN

PURPOSE: Neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) were established showing the poor prognosis in some diseases, such as cardiovascular diseases and malignancies. The risk of mortality in patients with end-stage renal disease (ESRD) was higher than normal population. In this study, we aimed to investigate the relationship between NLR, PLR, and all-cause mortality in prevalent hemodialysis (HD) patients. METHODS: Eighty patients were enrolled in study. NLR and PLR obtained by dividing absolute neutrophil to absolute lymphocyte count and absolute platelet count to absolute lymphocyte count, respectively. The patients were followed prospectively for 24 months. The primary end point was all-cause mortality. RESULTS: Mean levels of neutrophil, lymphocyte, and platelet were 3904 ± 1543/mm(3), 1442 ± 494/mm(3), 174 ± 56 × 10(3)/mm(3), respectively. Twenty-one patients died before the follow-up at 24 months. Median NLR and PLR were 2.52 and 130.4, respectively. All-cause mortality was higher in patients with high NLR group compared to the patients with low NLR group (18.8 vs. 7.5 %, p = 0.031) and in patients with higher PLR group compared to patients with lower PLR group (18.8 vs. 7.5 %, p = 0.022). Following adjusted Cox regression analysis, the association of mortality and high NLR was lost (p = 0.54), but the significance of the association of high PLR and mortality increased (p = 0.013). CONCLUSION: Although both NLR and PLR were associated with all-cause mortality in prevalent HD patients, only PLR could independently predict all-cause mortality in these populations.


Asunto(s)
Diálisis Renal/efectos adversos , Insuficiencia Renal Crónica/sangre , Insuficiencia Renal Crónica/mortalidad , Adulto , Anciano , Biomarcadores/sangre , Estudios de Cohortes , Femenino , Humanos , Estimación de Kaplan-Meier , Recuento de Leucocitos , Recuento de Linfocitos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Neutrófilos/metabolismo , Recuento de Plaquetas , Valor Predictivo de las Pruebas , Pronóstico , Modelos de Riesgos Proporcionales , Diálisis Renal/métodos , Diálisis Renal/mortalidad , Insuficiencia Renal Crónica/terapia , Estudios Retrospectivos , Análisis de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA