Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Pers Med ; 12(1)2022 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-35055373

RESUMEN

OBJECTIVES: The aim of this retrospective study was to analyze peri-implant marginal bone loss levels/rates and peri-implant sulcular fluid levels/rates of metalloproteinase-8 in three timeframes (6 months post-surgery-restoration delivery (T0)-and 6 (T6) and 24 (T24)-months post-loading) and to evaluate if there is a correlation between peri-implant sulcular fluid levels of metalloproteinase-8 and peri-implant marginal bone loss progression. MATERIALS AND METHODS: Two cohorts of patients undergoing implant surgery between January 2017 and January 2019 were selected in this retrospective study. A total of 39 patients received 39 implants with a laser-microtextured collar surface, and 41 subjects received 41 implants with a machined/smooth surface. For each patient, periapical radiographs and a software package were used to measure marginal bone loss rates. Implant fluid samples were analyzed by an enzyme-linked immunosorbent assay (ELISA) test. The modified plaque index, probing depth, and bleeding on probing were also recorded. RESULTS: High marginal bone rates at T24 were strongly associated with elevated rates between T0 and T6. The levels of metalloproteinase-8 were significantly more elevated around implants with marginal bone loss, in relation to implants without marginal bone loss. Marginal bone loss (MBL) rates at 24 months were associated with initial bone loss rates and initial levels of metalloproteinase-8. CONCLUSIONS: Peri-implant marginal bone loss progression is statistically correlated to peri-implant sulcular fluid levels of metalloproteinase-8. Moreover, the initial high levels of marginal bone loss and metalloproteinase-8 can be considered as indicators of the subsequent progression of peri-implant MBL: implants with increased marginal bone loss rates and metalloproteinase-8 levels at 6 months after loading are likely to achieve additional marginal bone loss values.

2.
J Pers Med ; 11(4)2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33808091

RESUMEN

The action of stem cells is mediated by their paracrine secretions which comprise the secretory profile. Various approaches can be used to modify the secretory profile of stem cells. Creating a hypoxic environment is one method. The present study aims to demonstrate the influence of CoCl2 in generating hypoxic conditions in a dental pulp stem cell (DPSCs) culture, and the effect of this environment on their secretory profile. DPSCs that were isolated from human permanent teeth were characterized and treated with different concentrations of CoCl2 to assess their viability by an 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and proliferation by a cell counting kit (CCK)-8 assay. The gene expression level of hypoxia-inducible factor 1-alpha (HIF-1α) was analyzed by quantitative real time polymerase chain reaction (qRT-PCR) to demonstrate a hypoxic environment. Comparative evaluation of the growth factors and cytokines were done by cytometric bead array. Gene expression levels of transcription factors OCT4 and SOX2 were analyzed by qRT-PCR to understand the effect of CoCl2 on stemness in DPSCs. DPSCs were positive for MSC-specific markers. Doses of CoCl2, up to 20 µM, did not negatively affect cell viability; in low doses (5 µM), it promoted cell survival. Treatment with 10 µM of CoCl2 significantly augmented the genetic expression of HIF-1α. Cells treated with 10 µM of CoCl2 showed changes in the levels of growth factors and cytokines produced. It was very evident that CoCl2 also increased the expression of OCT4 and SOX2, which is the modulation of stemness of DPSCs. A CoCl2 treatment-induced hypoxic environment modulates the secretory profile of DPSCs.

3.
Odontology ; 109(3): 568-573, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33245455

RESUMEN

Torsional stresses are one of the most frequent causes of intracanal separation of nickel-titanium endodontic instruments, which represents a great concern of endodontists. For this reason, torsional resistance of rotary instruments has been deeply investigated by determining all parameters that can influenced it, that can be summarized in: (1) Tooth-related factors, (2) Strategy-related factors and (3) Instrument-related factors. This study was conducted to examine the influence of shaft length on torsional resistance of a nickel-titanium rotary instrument and if it should be considered as an Instrument-related factor. With this aim, 120 Twisted Files Adaptive M-L (TFA M-L) NiTi instruments (SybronEndo, Orange, CA, USA) were divided into 6 experimental groups (n = 20), according to instruments length and size: Group 1, 20 TFA M-L1 25/08 23 mm; Group 2, 20 TFA M-L1 25/08 27 mm; Group 3, 20 TFA M-L2 35/06 23 mm; Group 4, 20 TFA M-L2 35/06 27 mm; Group 5, 20 TFA M-L3 50/04 23 mm; and Group 6, 20 TFA M-L3 50/04 27 mm. All instruments were submitted to a static torsional test, blocking each instrument at 3 mm from the tip and rotating it until its fracture. Torque to Fracture (TtF) and fragments length were registered and all data were statistically analyzed. Results showed that Groups 2, 4 and 6 had a higher TtF, respectively, than Groups 1, 3 and 5, which differ from the former just for shaft length. Group 6 showed the highest torsional resistance (1.31 ± 0.08 Ncm), whilst Group 1 the lowest (0.40 ± 0.08 Ncm). According to that, it can be stated that the longer the instrument, the higher the torsional resistance is, proving that shaft length should be considered as an important factor about torsional resistance.


Asunto(s)
Níquel , Titanio , Aleaciones Dentales , Instrumentos Dentales , Diseño de Equipo , Falla de Equipo , Ensayo de Materiales , Preparación del Conducto Radicular , Estrés Mecánico , Torque , Torsión Mecánica
4.
J Contemp Dent Pract ; 21(7): 728-732, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-33020354

RESUMEN

AIM: The aim of the present study is twofold: to evaluate cyclic fatigue resistance differences of two different nickel-titanium rotary instruments, brand new and after an ex vivo instrumentation of single root extracted teeth. MATERIALS AND METHODS: Twenty new S One 20.06 were randomly divided into two groups. The first group (n = 10) was immediately subjected to a cyclic fatigue test (S One Group I). The second group (n = 10) (S one Group II) performed a cyclic fatigue test after three ex vivo root canal treatment with a single-file technique. The same process has been carried out for 20 M-Two 20.06 instruments. RESULTS: Mean time to fracture (TtF) for Group I was 51.14 ± 1.28 for S One and 32.62 ± 0.17 for M-Two 20.06 and for Group II was 46.00 ± 0.99 for S One and 27.75 ± 1.58 for M-Two 20.06. The reduction in TtF values from Group I to Group II was 11% for S One and 15% for M-Two. Statistical analysis found significant differences in all the groups examined (p value < 0.05). Mean fragment length (FL) for Group I was 3.07 ± 0.17 for S One and 3.05 ± 0.14 for M-Two 20.06 and for Group II was 3.05 ± 0.07 for S One and 3.05 ± 0.14 for M-Two 20.06. Statistical analysis was pursued, and no significant difference was found (p value > 0.05). CONCLUSION: The S-One showed significantly more resistance to cyclic fatigue stress than M-Two for both new and used instruments. This validates the hypothesis that the AF H wire enables the S One files to endure more the cyclic fatigue stresses. CLINICAL SIGNIFICANCE: This study demonstrates the cyclic fatigue resistance of a new endodontic instrument after repetitive usage.


Asunto(s)
Níquel , Titanio , Cavidad Pulpar , Diseño de Equipo , Falla de Equipo , Ensayo de Materiales , Preparación del Conducto Radicular
5.
J Contemp Dent Pract ; 21(4): 351-352, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32584267

RESUMEN

In the last decades, the use of nickel-titanium (Ni-Ti) rotary instruments has become the most effective and popular method among endodontists for shaping root canals, even if there are still concerns regarding the increased risks of intracanal breakage or weakening of the instruments.1,2 So manufacturers started to modify the cross-sectional geometrical aspects of the files in order to improve their resistance to torsional and cyclic fatigue. Design is a major feature in determining instruments' properties including cutting efficiency, removal of debris, stresses generated during instrumentation, and the relative resistance to these stresses; however, a perfect design is not existing and any change in design is likely to provide some advantages but also some disadvantages.3,4.


Asunto(s)
Níquel , Titanio , Estudios Transversales , Aleaciones Dentales , Instrumentos Dentales , Diseño de Equipo , Falla de Equipo , Preparación del Conducto Radicular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA