Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Environ Qual ; 46(6): 1146-1157, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29293835

RESUMEN

The study of the speciation of highly diluted elements by X-ray absorption spectroscopy (XAS) is extremely challenging, especially in environmental biogeochemistry sciences. Here we present an innovative synchrotron spectroscopy technique: high-energy resolution fluorescence detected XAS (HERFD-XAS). With this approach, measurement of the XAS signal in fluorescence mode using a crystal analyzer spectrometer with a ∼1-eV energy resolution helps to overcome restrictions on sample concentrations that can be typically measured with a solid-state detector. We briefly describe the method, from both an instrumental and spectroscopic point of view, and emphasize the effects of energy resolution on the XAS measurements. We then illustrate the positive impact of this technique in terms of detection limit with two examples dealing with Ce in ecologically relevant organisms and with Hg species in natural environments. The sharp and well-marked features of the HERFD-X-ray absorption near-edge structure spectra obtained enable us to determine unambiguously and with greater precision the speciation of the probed elements. This is a major technological advance, with strong benefits for the study of highly diluted elements using XAS. It also opens new possibilities to explore the speciation of a target chemical element at natural concentration levels, which is critical in the fields of environmental and biogeochemistry sciences.


Asunto(s)
Monitoreo del Ambiente , Espectroscopía de Absorción de Rayos X , Ecología
2.
Phys Chem Chem Phys ; 18(36): 25136-25142, 2016 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-27711527

RESUMEN

We have studied the local structure and valence electronic unoccupied states of thermoelectric CsBi4Te6 and superconducting CsBi3.5Pb0.5Te6 (Tc ∼ 3 K) by extended X-ray absorption fine structure (EXAFS) and X-ray absorption near edge structure (XANES) measurements. The Bi-L3 edge EXAFS reveals wide Bi-Te distance distribution for both compounds indicating complex atomic arrangements in the studied system. The mean square relative displacements (MSRDs) of the Bi-Te bond distances appear largely increased in Pb substituted system due to larger overall local disorder, however, one of the Bi-Te bonds shows a reduced disorder. On the other hand, the Bi-L3 edge XANES is hardly affected by Pb substitution while the Te-L1 edge XANES reveals increased density of unoccupied Te 5p states. This suggests that the carriers introduced by the Pb substitution in CsBi4-xPbxTe6 preferentially goes on Te sites. Similarly, the Cs-L3 edge XANES also shows small changes due to Pb-substitution and reduced local disorder indicated by the reduced width of the Cs-L3 edge white line. We have also shown that the X-ray photoemission spectroscopy (XPS) measurements on various electronic core levels are in a qualitative agreement with the XANES results. These findings are consistent with carrier doping and a reduced disorder in one direction to be likely factors to drive the thermoelectric CsBi4Te6 into a bulk superconductor by Pb-substitution in CsBi4-xPbxTe6.

3.
Proc Natl Acad Sci U S A ; 112(44): 13484-9, 2015 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-26460040

RESUMEN

Current models of the formation and distribution of gold deposits on Earth are based on the long-standing paradigm that hydrogen sulfide and chloride are the ligands responsible for gold mobilization and precipitation by fluids across the lithosphere. Here we challenge this view by demonstrating, using in situ X-ray absorption spectroscopy and solubility measurements, coupled with molecular dynamics and thermodynamic simulations, that sulfur radical species, such as the trisulfur ion S3(-), form very stable and soluble complexes with Au(+) in aqueous solution at elevated temperatures (>250 °C) and pressures (>100 bar). These species enable extraction, transport, and focused precipitation of gold by sulfur-rich fluids 10-100 times more efficiently than sulfide and chloride only. As a result, S3(-) exerts an important control on the source, concentration, and distribution of gold in its major economic deposits from magmatic, hydrothermal, and metamorphic settings. The growth and decay of S3(-) during the fluid generation and evolution is one of the key factors that determine the fate of gold in the lithosphere.

4.
Angew Chem Int Ed Engl ; 53(46): 12426-9, 2014 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-25056683

RESUMEN

Platinum nanoclusters highly dispersed on γ-alumina are widely used as heterogeneous catalysts. To understand the chemical interplay between the Pt nanoparticles, the support, and the reductive atmosphere, we performed X-ray absorption near edge structure (XANES) in situ experiments recorded in high energy resolution fluorescence detection (HERFD) mode. Spectra are assigned by comparison with simulated XANES spectra on models obtained by molecular dynamics (DFT-MD). We propose platinum cluster morphologies and quantify the hydrogen coverages compatible with XANES spectra recorded at variable hydrogen pressures and temperatures. Using cutting-edge methodologies to assign XANES spectra, this work gives unequalled atomic insights into the characterization of supported nanoclusters.

5.
J Synchrotron Radiat ; 16(Pt 2): 283-92, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19240341

RESUMEN

A bent-crystal spectrometer based on the Rowland circle geometry has been installed and tested on the BM30b/FAME beamline at the European Synchrotron Radiation Facility to improve its performances. The energy resolution of the spectrometer allows different kinds of measurements to be performed, including X-ray absorption spectroscopy, resonant inelastic X-ray scattering and X-ray Raman scattering experiments. The simplicity of the experimental device makes it easily implemented on a classical X-ray absorption beamline. This improvement in the fluorescence detection is of particular importance when the probed element is embedded in a complex and/or heavy matrix, for example in environmental sciences.


Asunto(s)
Espectrometría por Rayos X/instrumentación , Espectrometría por Rayos X/métodos , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...