Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Hand Surg Rehabil ; 40(5): 535-546, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34033928

RESUMEN

Flexor tendon rupture after volar plate fixation of distal radius fracture (DRF) is rare. There is no consensus as to how to prevent them. The aim of our study was to identify the pathological mechanisms, and to establish the clinical and epidemiological profile of patients suffering from this complication. We carried out a systematic review using the PubMed, Scopus and Cochrane databases. Studies were included if they described complete or partial flexor tendon rupture following volar plate fixation of DRF. Forty-six 46 were included, for a total of 145 patients were reported: 138 from the literature, and 7 from our personal experience. Etiology was usually mechanical, by impingement with either the plate or protruding screws. Plate impingement was due to positioning beyond the watershed line, consolidation with posterior tilt, plate thickness, or low palmar cortical angle. Mean patient age was 62.4 years (range, 23-89 years). Median postoperative interval was 8 months (range, 3-120 months). Flexor pollicis longus was the most frequently injured tendon. The plate should be positioned proximally to the watershed line if possible, to ensure good initial reduction. Hardware should be removed 4 months after surgery if the plate is causing impingement according to the Soong criteria or if signs of tenosynovitis appear.


Asunto(s)
Fracturas del Radio , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Humanos , Persona de Mediana Edad , Fracturas del Radio/complicaciones , Fracturas del Radio/cirugía , Rotura/etiología , Tendones , Adulto Joven
2.
Hand Surg Rehabil ; 39(5): 437-441, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32387690

RESUMEN

Wrapping microsurgical sutures with a vein conduit is a well-described procedure for microsurgical nerve repair. While this has rarely been described in the context of vascular repair, this technique could increase the permeability of the sutured vessels. As part of a University Diploma in Microsurgery, 9 junior surgeons performed a comparative study of 18 microsurgical repairs on rats with and without vein sleeve. The vessels used were an external jugular vein sleeve on the end-to-end anastomosis of the common carotid artery and comparing it to this same anastomosis without a sleeve. The data analyzed were rat weight, suture time with carotid clamping time, number of stitches used, complications as well as vascular leakage and permeability of the repair at 0 and 5minutes evaluated with a patency test. The average rat body weight was 255g. Mean suture time was 52minutes in group A (sleeved repairs) and 41minutes in group B (standard repairs). The number of stitches placed was 5.1 points on average in group A and 5.6 points in group B. The time to perform the repair and the number of stitches was not statistically different between groups. The patency test was positive in 100% of cases in group A and in 78% of cases in group B. There was a significant difference between the permeability rate of the repairs, with better results in group A (p=0.03). There were two anastomotic leaks after declamping in the sleeve group and five in the standard suture group, thus 2.5 times more leaks in the group without a sleeve (p<0.01). The addition of a vein sleeve around an end-to-end arterial suture repair seems to improve its permeability and therefore its reliability.


Asunto(s)
Anastomosis Quirúrgica/métodos , Arteria Carótida Común/cirugía , Venas Yugulares/trasplante , Microcirugia/métodos , Animales , Modelos Animales , Tempo Operativo , Distribución Aleatoria , Ratas Wistar , Suturas , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...