Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
JCO Oncol Pract ; 19(6): e811-e821, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36821818

RESUMEN

PURPOSE: Although electronic patient-reported outcomes (ePROs) are efficacious in symptom management, much is unknown about the utility of vital signs surveillance. We examined the feasibility of a remote patient monitoring platform that integrates ePROs and biometrics into the ambulatory management of symptom burden. METHODS: Using a decentralized workflow, patients with gastrointestinal or thoracic cancer were approached for a 1-month study. Patients reported symptom burden via ePROs and biometrics (blood pressure, oxygen saturation, pulse, weight, and temperature) using bluetooth-enabled devices daily. Alerts on the basis of prespecified thresholds were managed via nurse-led triage. Adherence was defined as the completion of > 70% of daily symptom and biometric reporting requirements. Pilot acceptability, appropriateness, and feasibility were measured using validated instruments. Net promoter score, system usability scale, and emergency department (ED) admission rates were collected. RESULTS: Over 8 months, 36 patients were enrolled and 25 (60% gastrointestinal) completed the study. Participants had a mean age of 58.0 years, mean Eastern Cooperative Oncology Group score of 0.88, were 52% female, and predominantly had stage IV or recurrent disease (72%). Program adherence was 73% and associated with high acceptability (4.63), feasibility (4.56), and appropriateness (4.46). System usability scale and net promoter score scores were 88 and 55, respectively. Seventy percent of alerts were generated by biometrics, 28% for symptoms, and 2% were patient-initiated communication. Finally, the ED visitation rate over the pilot period was 8%. CONCLUSION: Our remote patient monitoring pilot program was highly acceptable, feasible, and appropriate. It had high rates of patient adherence and satisfaction and was associated with low ED visitation rates.


Asunto(s)
Neoplasias , Cooperación del Paciente , Humanos , Adulto , Femenino , Persona de Mediana Edad , Masculino , Proyectos Piloto , Estudios de Factibilidad , Biometría
2.
Sports Health ; 15(3): 361-371, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35762124

RESUMEN

BACKGROUND: Muscle atrophy is common after an injury to the knee and anterior cruciate ligament reconstruction (ACLR). Blood flow restriction therapy (BFR) combined with low-load resistance exercise may help mitigate muscle loss and improve the overall condition of the lower extremity (LE). PURPOSE: To determine whether BFR decreases the loss of LE lean mass (LM), bone mass, and bone mineral density (BMD) while improving function compared with standard rehabilitation after ACLR. STUDY DESIGN: Randomized controlled clinical trial. METHODS: A total of 32 patients undergoing ACLR with bone-patellar tendon-bone autograft were randomized into 2 groups (CONTROL: N = 15 [male = 7, female = 8; age = 24.1 ± 7.2 years; body mass index [BMI] = 26.9 ± 5.3 kg/m2] and BFR: N = 17 [male = 12, female = 5; age = 28.1 ± 7.4 years; BMI = 25.2 ± 2.8 kg/m2]) and performed 12 weeks of postsurgery rehabilitation with an average follow-up of 2.3 ± 1.0 years. Both groups performed the same rehabilitation protocol. During select exercises, the BFR group exercised under 80% arterial occlusion of the postoperative limb (Delfi tourniquet system). BMD, bone mass, and LM were measured using DEXA (iDXA, GE) at presurgery, week 6, and week 12 of rehabilitation. Functional measures were recorded at week 8 and week 12. Return to sport (RTS) was defined as the timepoint at which ACLR-specific objective functional testing was passed at physical therapy. A group-by-time analysis of covariance followed by a Tukey's post hoc test were used to detect within- and between-group changes. Type I error; α = 0.05. RESULTS: Compared with presurgery, only the CONTROL group experienced decreases in LE-LM at week 6 (-0.61 ± 0.19 kg, -6.64 ± 1.86%; P < 0.01) and week 12 (-0.39 ± 0.15 kg, -4.67 ± 1.58%; P = 0.01) of rehabilitation. LE bone mass was decreased only in the CONTROL group at week 6 (-12.87 ± 3.02 g, -2.11 ± 0.47%; P < 0.01) and week 12 (-16.95 ± 4.32 g,-2.58 ± 0.64%; P < 0.01). Overall, loss of site-specific BMD was greater in the CONTROL group (P < 0.05). Only the CONTROL group experienced reductions in proximal tibia (-8.00 ± 1.10%; P < 0.01) and proximal fibula (-15.0±2.50%,P < 0.01) at week 12 compared with presurgery measures. There were no complications. Functional measures were similar between groups. RTS time was reduced in the BFR group (6.4 ± 0.3 months) compared with the CONTROL group (8.3 ± 0.5 months; P = 0.01). CONCLUSION: After ACLR, BFR may decrease muscle and bone loss for up to 12 weeks postoperatively and may improve time to RTS with functional outcomes comparable with those of standard rehabilitation.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Terapia de Restricción del Flujo Sanguíneo , Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Adulto , Lesiones del Ligamento Cruzado Anterior/cirugía , Extremidad Inferior/fisiología , Articulación de la Rodilla , Músculos
3.
BMJ Open ; 12(4): e057693, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-35383081

RESUMEN

INTRODUCTION: Remote patient monitoring (RPM) has emerged as a potential avenue for optimising the management of symptoms in patients undergoing chemotherapy. However, RPM is a complex, multilevel intervention with technology, workflow, contextual and patient experience components. The purpose of this pilot study is to determine the feasibility of RPM protocol implementation with respect to decentralised recruitment, patient retention, adherence to reporting recommendations, RPM platform usability and patient experience in ambulatory cancer patients at high risk for chemotherapy-related symptoms. METHODS AND ANALYSIS: This protocol describes a single-arm decentralised feasibility pilot study of technology-enhanced outpatient symptom management system in patients with gastrointestinal and thoracic cancer receiving chemotherapy and cancer care at a single site (MD Anderson Cancer Center, Houston Texas). An anticipated total of 25 patients will be recruited prior to the initiation of chemotherapy and provided with a set of validated questionnaires at enrollment and after our 1-month feasibility pilot trial period. Our intervention entails the self-reporting of symptoms and vital signs via a HIPAA-compliant, secure tablet interface that also enables (1) the provision of self-care materials to patients, (2) generation of threshold alerts to a dedicated call-centre and (3) videoconferencing. Vital sign information (heart rate, blood pressure, pulse, oxygen saturation, weight and temperature) will be captured via Bluetooth-enabled biometric monitoring devices which are integrated with the tablet interface. Protocolised triage and management of symptoms will occur in response to the alerts. Feasibility and acceptability metrics will characterise our recruitment process, protocol adherence, patient retention and usability of the RPM platform. We will also document the perceived effectiveness of our intervention by patients. ETHICS AND DISSEMINATION: This study has been granted approval by the institutional review board of MD Anderson Cancer Center. We anticipate dissemination of our pilot and subsequent effectiveness trial results via presentations at national conferences and peer-reviewed publications in the relevant medical journals. Our results will also be made available to cancer survivors, their caregivers and hospital administration. TRIAL REGISTRATION NUMBER: NCI202107464.


Asunto(s)
Neoplasias , Espera Vigilante , Electrónica , Estudios de Factibilidad , Humanos , Neoplasias/tratamiento farmacológico , Medición de Resultados Informados por el Paciente , Proyectos Piloto , Signos Vitales
4.
Front Psychol ; 12: 685815, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34566764

RESUMEN

This study fills a void in the literature by both validating images of nature for use in future research experiments and examining which characteristics of these visual stimuli are found to be most representative of nature. We utilized a convenience sample of university students to assess 129 different nature images on which best represented nature. Participants (n = 40) viewed one image per question (n = 129) and were asked to rate images using a 5-point Likert scale, with the anchors "best represents nature" (5) and "least represents nature" (1). Average ratings across participants were calculated for each image. Canopies, mountains, bodies of water, and unnatural elements were identified as semantic categories of interest, as well as atmospheric perspectives and close-range views. We conducted the ordinary least squares (OLS) regression and the ordered logistic regression analyses to identify semantic categories highly representative of nature, controlling for the presence/absence of other semantic categories. The results showed that canopies, bodies of water, and mountains were found to be highly representative of nature, whereas unnatural elements and close-range views were inversely related. Understanding semantic categories most representative of nature is useful in developing nature-centered interventions in behavioral performance research and other neuroimaging modalities. All images are housed in an online repository and we welcome the use of the final 10 highly representative nature images by other researchers, which will hopefully prompt and expedite future examinations of nature across multiple research formats.

5.
Orthop J Sports Med ; 9(1): 2325967120968099, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33786328

RESUMEN

BACKGROUND: The Beighton score is commonly used to assess the degree of hypermobility in patients with hypermobility spectrum disorder. Since proper diagnosis and treatment in this challenging patient population require valid, reliable, and responsive clinical assessments such as the Beighton score, studies must properly evaluate efficacy and effectiveness. PURPOSE: To succinctly present a systematic review to determine the inter- and intrarater reliability of the Beighton score and the methodological quality of all analyzed studies for use in clinical applications. STUDY DESIGN: Systematic review; Level of evidence, 3. METHODS: A systematic review of the MEDLINE, Embase, CINAHL, and SPORTDiscus databases was performed. Studies that measured inter- or intrarater reliability of the Beighton score in humans with and without hypermobility were included. Non-English, animal, cadaveric, level 5 evidence, and studies utilizing the Beighton score self-assessment version were excluded. Data were extracted to compare scoring methods, population characteristics, and measurements of inter- and intrarater reliability. Risk of bias was assessed with the COSMIN (Consensus-Based Standards for the Selection of Health Measurement Instruments) 2017 checklist. RESULTS: Twenty-four studies were analyzed (1333 patients; mean ± SD age, 28.19 ± 17.34 years [range, 4-71 years]; 640 females, 594 males, 273 unknown sex). Of the 24 studies, 18 reported raters were health care professionals or health care professional students. For interrater reliability, 5 of 8 (62.5%) intraclass correlation coefficients and 12 of 19 (63.2%) kappa values were substantial to almost perfect. Intrarater reliability was reported as excellent in all studies utilizing intraclass correlation coefficients, and 3 of the 7 articles using kappa values reported almost perfect values. Utilizing the COSMIN criteria, we determined that 1 study met "very good" criteria, 7 met "adequate," 15 met "doubtful," and 1 met "inadequate" for overall risk of bias in the reliability domain. CONCLUSION: The Beighton score is a highly reliable clinical tool that shows substantial to excellent inter- and intrarater reliability when used by raters of variable backgrounds and experience levels. While individual components of risk of bias among studies demonstrated large discrepancy, most of the items were adequate to very good.

6.
Orthop J Sports Med ; 8(7): 2325967120937643, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32782904

RESUMEN

BACKGROUND: Few investigations have examined dance-specific injury prevention programs (IPPs), and no published randomized controlled trials are available that evaluate IPPs for dance. HYPOTHESIS: The implementation of an IPP will significantly reduce the risk of injury in professional ballet dancers. STUDY DESIGN: Randomized controlled trial; Level of evidence, 2. METHODS: A randomized controlled trial was designed that entailed a superiority model for the intervention group. All professional dancers from a single ballet company were eligible to participate. Randomization and allocation were performed before the start of the season. The control group practiced and performed without change to preexisting standard operating practice. The IPP group was instructed to perform a 30-minute exercise program 3 times per week over the 52-week study period. Injuries were recorded. Standard continuous and categorical data comparisons and correlations were used. Cox proportional hazards regression models for recurrent failures were used wherein the hazard ratio indicates the relative likelihood of injury in the control versus intervention groups. RESULTS: Of the 52 eligible dancers, 75% (n = 39) participated. Of these 39 dancers, 19 (9 males, 10 females; mean age, 26.6 ± 4.0 years) were randomized to the control group and 20 (11 males, 9 females; mean age, 25.1 ± 5.1 years) to the IPP group. No significant (P > .05) difference was found in baseline demographics between groups. A total of 116 injuries were recorded for the entire study population (49 IPP; 67 control). Traumatic and chronic injuries accounted for 54% and 46% of injuries, respectively. The injury rate was 82% less (IPP hazard ratio, 0.18; z = -2.29; P = .022) in the IPP group after adjustment for confounding variables, and time between injuries was 45% longer (IPP hazard ratio, 0.55; z = -2.20; P = .028) than for controls. CONCLUSION: The present study is the first prospective randomized controlled investigation of an IPP for professional ballet. The results showed an 82% decrease in injury rate for the intervention group and an extended period from previous injury to subsequent injury. REGISTRATION: NCT04110002 (ClinicalTrials.gov identifier).

7.
Int J Exerc Sci ; 13(3): 802-817, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32509120

RESUMEN

Performing yoga in a heated environment (HY) is a popular exercise mode purported to improve range of motion (ROM), body composition, and aerobic fitness. The purpose of this investigation was to compare a session of HY to room temperature yoga (RTY) with regards to ROM, oxygen consumption, caloric expenditure, and biomarkers of acute stress and inflammation. Sixteen experienced yoga practitioners (F14, M2; 40 ± 11yr; 22.6 ± 1.8 kg/m2) completed a 1-hour standardized Bikram sequence in HY (105°F, 40°C) and RTY (74°F, 23.3°C) conditions (order of conditions randomized, humidity standardized at 40%). Intra-exercise metabolic gas exchange and heart rate (HR) was monitored using a metabolic cart. ROM measures were taken pre and post-exercise at the elbow, shoulder, hip, and knee. Cytokines interleukin 6,10 (IL-6, IL-10) and tumor-necrosis-factor alpha (TNF-α) were analyzed from blood samples collected pre- and 30-minutes post-exercise. Intra-exercise metabolic gas exchange and heart rate (HR) was monitored using a metabolic cart. Both bouts elicited similar acute changes in ROM although HY elicited a greater increase in hip abduction (RTYΔ° = 2.3 ± 1.3|HYΔ° = 6.6 ± 1.5; p < 0.05). Mean VO2, peak VO2, %VO2max, HR, and kcal expenditure did not differ between conditions. RER was lower during the HY (RTY = 0.95 ± 0.02| HY = 0.89 ± 0.02; p < 0.05) with a concomitant elevation in fat oxidation (RTY = 0.05 ± 0.01|HY = 0.09 ± 0.01, g·min-1; p < 0.05) and decrease in carbohydrate oxidation (RTY = 0.51 ± 0.04|HY = 0.44 ± 0.03, g·min-1; p < 0.05). Serum IL-6 was increased (15.5 ± 8.0-fold) following HY only (p < 0.05). HY does not significantly elevate aerobic energy cost compared to RTY but may acutely increase fat substrate utilization and hip ROM. Future studies remain needed to establish dose-response relationships for including HY or RTY into well-rounded fitness programs.

8.
Am J Sports Med ; 48(1): 222-228, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31765226

RESUMEN

BACKGROUND: There is a high prevalence of hypermobility spectrum disorder (HSD) in dancers. While there is no known genetic variant for HSD, hypermobile Ehlers-Danlos syndrome is a genetic disorder that exists within HSD. There are many connective tissue disorders (CTDs) with known (and unknown) genes associated with hypermobility. Hypermobility has distinct advantages for participation in flexibility sports, including ballet. PURPOSE: To determine the prevalence of gene variants associated with hypermobility in a large professional ballet company. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: In this cross-sectional investigation, 51 professional male and female dancers from a large metropolitan ballet company were eligible and offered participation after an oral and written informed consent process. Whole blood was obtained from peripheral venipuncture, and DNA was isolated. Isolated DNA was subsequently enriched for the coding exons of 60 genes associated with CTD that included hypermobility as a phenotype, including Ehlers-Danlos syndromes, osteogenesis imperfecta, Marfan syndrome, and others. Genes were targeted with hybrid capture technology. Prepared DNA libraries were then sequenced with next-generation sequencing technology. Genetic database search tools (Human Gene Mutation Database and e!Ensembl, http://useast.ensembl.org/ ) were used to query specific variants. Descriptive statistics were calculated. RESULTS: Of 51 dancers, 32 (63%) agreed to participate in DNA analysis (mean ± SD age, 24.3 ± 4.4 years; 18 men, 14 women). Twenty-eight dancers had at least 1 variant in the 60 genes tested, for an 88% prevalence. A total of 80 variants were found. A variant in 26 of the 60 genes was found in at least 1 dancer. Among the 28 dancers with variants, 16 were found in the TTN gene; 10 in ZNF469; 5 in RYR1; 4 in COL12A1; 3 in ABCC6 and COL6A2; 2 in ADAMTS2, CBS, COL1A2, COL6A3, SLC2A10, TNC, and TNXB; and 1 in ATP6V0A2, B4GALT7, BMP1, COL11A1, COL5A2, COL6A1, DSE, FBN1, FBN2, NOTCH1, PRDM5, SMAD3, and TGFBR1. Nine variants found in this population have never been reported. No identified variant was identical to any other variant. No identified variant was known to be disease causing. In the general population, the prevalence of each variant ranges from never reported to 0.33%. In the study population, the prevalence of each variant was 3.13%. There was no association between hypermobility scores and genetic variants. CONCLUSION: Genetic variants in CTD-associated genes are highly prevalent (88%) in professional ballet dancers. This may significantly account for the high degree of motion in this population.


Asunto(s)
Enfermedades del Tejido Conjuntivo/genética , Tejido Conectivo/metabolismo , Baile/fisiología , Adolescente , Adulto , Estudios Transversales , Síndrome de Ehlers-Danlos/genética , Femenino , Humanos , Masculino , Prevalencia , Adulto Joven
9.
J Am Acad Orthop Surg Glob Res Rev ; 2(3): e088, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30211382

RESUMEN

BACKGROUND: The visual analog scale (VAS) is a validated, subjective measure for acute and chronic pain. Scores are recorded by making a handwritten mark on a 10-cm line that represents a continuum between "no pain" and "worst pain." METHODS: One hundred consecutive patients aged ≥18 years who presented with a chief complaint of pain were asked to record pain scores via a paper VAS and digitally via both the laptop computer and mobile phone. Ninety-eight subjects, 51 men (age, 44 ± 16 years) and 47 women (age, 46 ± 15 years), were included. A mixed-model analysis of covariance with the Bonferroni post hoc test was used to detect differences between the paper and digital VAS scores. A Bland-Altman analysis was used to test for instrument agreement between the platforms. The minimal clinically important difference was set at 1.4 cm (14% of total scale length) for detecting clinical relevance between the three VAS platforms. A paired one-tailed Student t-test was used to determine whether differences between the digital and paper measurement platforms exceeded 14% (P < 0.05). RESULTS: A significant difference in scores was found between the mobile phone-based (32.9% ± 0.4%) and both the laptop computer- and paper-based platforms (31.0% ± 0.4%, P < 0.01 for both). These differences were not clinically relevant (minimal clinically important difference <1.4 cm). No statistically significant difference was observed between the paper and laptop computer platforms. Measurement agreement was found between the paper- and laptop computer-based platforms (mean difference, 0.0% ± 0.5%; no proportional bias detected) but not between the paper- and mobile phone-based platforms (mean difference, 1.9% ± 0.5%; proportional bias detected). CONCLUSION: No clinically relevant difference exists between the traditional paper-based VAS assessment and VAS scores obtained from laptop computer- and mobile phone-based platforms.

10.
Orthop J Sports Med ; 6(8): 2325967118791790, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30159357

RESUMEN

BACKGROUND: Sexual difficulties and dysfunction are common in patients with femoroacetabular impingement syndrome (FAIS) secondary to hip pain and stiffness. PURPOSE: To determine the risk of impingement in patients with FAIS during common sexual positions using 3-dimensional computer-simulated collision detection before and after cam correction. STUDY DESIGN: Descriptive laboratory study. METHODS: Ten computed tomography scans of the pelvis and femur from patients with FAIS due to isolated cam morphology were retrospectively reviewed. Three-dimensional osseous models were developed using Mimics software. The cam deformity was then completely corrected. Simulations of hip range of motion for the most common sexual positions for men (n = 15) and women (n = 14) were conducted before and after cam resection. Impingement was determined for each sexual position. Position safety was defined as ≤20% of models demonstrating impingement in a position. Descriptive and simple comparative statistics were calculated. RESULTS: There was no sexual position that was impingement free in all models before cam correction. After cam correction, 11 (37.9%) of 29 total positions were impingement free. There was a significant decrease in impingement from before to after cam correction (40.7% vs 11.4%, respectively, of all female positions [P < .0001]; 26.0% vs 6.7%, respectively, of all male positions [P < .0001]). There was a significant increase in the number of "safe" positions from before to after cam correction (4 vs 11, respectively, of all female positions [P = .008]; 7 vs 15, respectively, of all male positions [P = .001]). CONCLUSION: After cam correction, there was a significant reduction in the impingement rate and a significant increase in the number of "safe" sexual positions. CLINICAL RELEVANCE: Impingement in patients with cam morphology is common during sexual activity. Surgical correction of cam morphology significantly reduces the rate of impingement. Although this laboratory imaging-only study did not account for patient symptoms, this likely translates to significant symptomatic improvement during sexual activity after surgical cam correction.

11.
Hip Int ; 28(5): 542-547, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29756502

RESUMEN

BACKGROUND: Supraacetabular fossae (SAF) are normal anatomic variants found at the 12 o'clock position of the acetabulum and can be mistaken for osteochondral defects. PURPOSE: Determine SAF prevalence on MRI of patients with hip pain. Characterise SAF by type, size, and location. Determine sensitivity of radiology reports and sensitivity of radiographs in SAF detection. METHODS: MRIs performed over 1 year in patients with hip/groin pain were analysed for SAF. Measurements of SAF in the coronal and sagittal planes and location using clockface notation were recorded. Radiology reports were reviewed to determine if SAF were identified and radiographs were assessed for presence of SAF. Mean characteristics of type 1 and 2 SAF were compared using Student's t-test. RESULTS: 214 hips (mean age 35.9 ± 14.2 years; 66.8% female) were analysed. Twenty-seven hips (12.6%) had SAF. There were five type 1 SAF (mean age 16.8 ± 2.2 years) and 23 type 2 SAF (mean age 33.0 ± 16.3 years). Mean dimensions of type 1 and 2 SAF (coronal width × sagittal width × depth, in millimetres) were 7.1 × 6.5 × 3.4 and 6.1 × 5.9 × 2.8, respectively. Mean clockwise location in the coronal and sagittal planes (in minutes) was 1236 and 1212 for type 1 SAF and 1213 and 1207 for type 2 SAF. Radiology reports identified 7.1% of SAF identified on MRI. Plain radiographs demonstrated 67.9% of SAF identified on MRI. CONCLUSION: This study found a 12.6% prevalence of SAF in hips. Radiology reports had a 7.1% sensitivity in correctly identifying SAF on MRI. IRB: Pro00016584.


Asunto(s)
Acetábulo/patología , Artralgia/diagnóstico , Cartílago Articular/patología , Articulación de la Cadera/patología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven
12.
J Am Acad Orthop Surg ; 26(10): e221-e229, 2018 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-29688961

RESUMEN

INTRODUCTION: Our study assessed the effect of total intravenous anesthesia (TIVA) with short-acting spinal anesthesia and aggressive day-of-surgery postoperative day 0 physical therapy (POD#0 PT) on hospital length of stay (LOS) in patients who underwent primary total joint arthroplasty. METHODS: A retrospective chart review compared the hospital LOS of 116 patients who underwent primary total hip arthroplasty and total knee arthroplasty with TIVA and short-acting spinal blockade ("Updated protocol group") with that of the control group of 228 patients who were under standard anesthesia ("Traditional protocol group"). RESULTS: Both total hip arthroplasty and total knee arthroplasty patients in the Updated protocol group had markedly reduced LOS compared with those in the Traditional protocol group (1.5 ± 0.1 days versus 2.4 ± 0.1 days; P < 0.05 and 1.4 ± 0.1 days versus 2.3 ± 0.1 days; P < 0.05). A higher proportion of patients in the Updated protocol group received at least 1 POD#0 PT session compared with those in the Traditional protocol group. CONCLUSION: Total intravenous anesthesia combined with short-acting spinal anesthetics provided the following benefits for patients who underwent primary total joint arthroplasty: more day-of-surgery PT sessions and earlier discharge by nearly 1 full day. LEVEL OF EVIDENCE: III.


Asunto(s)
Anestesia Intravenosa , Anestesia Raquidea , Anestésicos Locales/administración & dosificación , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Anciano , Anciano de 80 o más Años , Protocolos Clínicos , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Modalidades de Fisioterapia , Estudios Retrospectivos , Factores de Tiempo
13.
Arthroscopy ; 34(6): 1856-1861, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29477606

RESUMEN

PURPOSE: To determine if there are significant differences in preoperative patient-reported outcome (PRO) scores in patients with and without self-reported medication allergies undergoing hip arthroscopy. METHODS: Consecutive subjects undergoing hip arthroscopy for femoroacetabular impingement (FAI) syndrome by a single surgeon were retrospectively reviewed. PROs were collected within 6 weeks of the date of surgery. PROs included International Hip Outcome Tool (iHOT-12), Hip Outcome Score (HOS), and Short-Form (SF-12) scores. Allergies to medications were self-reported preoperatively within 6 weeks of the date of surgery. Patient demographics were recorded. Bivariate correlations and multivariate regression models were calculated to identify associations with baseline hip outcome scores. RESULTS: Two hundred twelve subjects were analyzed (56% female, mean age 35.1 ± 13.2 years). Seventy-two subjects (34%) self-reported allergies (range 1-10; 41 subjects had 1 allergy; 14 subjects had 2; 8 subjects had 3; 2 subjects had 4; 7 subjects had 5 or more). The most commonly reported allergies included penicillin (18), sulfa (13), and codeine (11). Female gender was significantly correlated with number of allergies (Pearson correlation coefficient, 0.188; P < .001). SF-12 Mental Component Score (MCS) was significantly correlated with HOS-ADL (Pearson correlation coefficient, 0.389; P < .001), HOS-SSS (Pearson correlation coefficient, 0.251; P < .001), and iHOT-12 (Pearson correlation coefficient, 0.385; P < .001). There was no significant correlation between number of allergies and all hip PROs. In all multivariate models, the SF-12 MCS had the strongest association with HOS-ADL, HOS-SSS, and iHOT-12 (P < .001 for all). Allergies were not significantly associated with any hip PROs. CONCLUSIONS: In patients undergoing hip arthroscopy for FAI syndrome, self-reported medication allergies are not significantly associated with preoperative patient-reported hip outcome scores. LEVEL OF EVIDENCE: Level III, retrospective comparative case series.


Asunto(s)
Artroscopía/efectos adversos , Hipersensibilidad a las Drogas , Pinzamiento Femoroacetabular/cirugía , Medición de Resultados Informados por el Paciente , Autoinforme , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
14.
Am J Sports Med ; 46(5): 1220-1227, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29466679

RESUMEN

BACKGROUND: Fifth metatarsal base fractures of the metaphyseal-diaphyseal watershed junction (Jones fracture) are commonly treated with surgical fixation in athletes. Intramedullary screw fixation remains the most utilized construct, although plantar-lateral plating is an alternative. Purpose/Hypothesis: The purpose was to compare the mechanical strength of fracture fixation between an intramedullary screw and plantar-lateral plating. The hypothesis was that plantar-lateral plate fixation would allow for more cycles and higher peak loads before failure, as well as less fracture gapping, than would an intramedullary screw in cadaveric foot specimens with simulated Jones fractures exposed to cantilever bending. STUDY DESIGN: Controlled laboratory study. METHODS: Twelve pairs of male cadaver feet were separated into 2 groups (plate or screw) to conduct contralateral comparative testing of 2 devices with equally numbered right and left feet. For each fifth metatarsal, an osteotomy with a microsagittal saw was created to simulate a Jones fracture. The plate group underwent fixation with a 3.0-mm 4-hole low-profile titanium plate placed plantar-laterally with 3 locking screws and 1 nonlocking screw. The screw group underwent fixation with a 40- or 45-mm × 5.5-mm partially threaded solid titanium intramedullary screw. After fixation, the metatarsals were excised for biomechanical testing. Cyclic cantilever failure testing was conducted with a gradient-cycle method. Sinusoidal loading forces were applied, increasing by 5.0-pound-force increments per 10 cycles, until each specimen experienced mechanical failure of implant or bone. Failure mode, number of cycles to failure, peak failure load, gap width at the last mutual prefailure loading, and video data were recorded. Paired 2-tailed t test (α = 0.05) was used to compare groups ( P < .05 set for significance). RESULTS: Failure mode in both groups occurred predominantly at the bone-implant interface. Plate fixation resulted in significantly higher mean ± SD values for cycles to failure (63.9 ± 27.0 vs 37.3 ± 36.9, P = .01) and peak failure load (159.2 ± 60.5 N vs 96.5 ± 45.8 N, P = .01), with a significantly lower mean gap width (0.0 ± 0.0 mm vs 3.2 ± 2.4 mm, P < .01). CONCLUSION: As compared with intramedullary screw fixation, plantar-lateral plating allowed for greater cycles to failure and peak load before failure, as well as less gap width, when applied to cadaver foot specimens with simulated Jones fractures exposed to cantilever bending in a load frame. CLINICAL RELEVANCE: Early return to play among athletes before Jones fracture union is associated with increased risk of failure. This study introduces a plantar-lateral plating construct that performed more favorably than intramedullary screw fixation when applied to simulated Jones fractures in cadaveric foot specimens. Further clinical comparative studies are needed to assess the clinical use of this construct.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Huesos Metatarsianos/lesiones , Huesos Metatarsianos/cirugía , Anciano , Fenómenos Biomecánicos , Cadáver , Epífisis , Fijación Interna de Fracturas/instrumentación , Fijación Intramedular de Fracturas , Humanos , Masculino , Persona de Mediana Edad
15.
Knee Surg Sports Traumatol Arthrosc ; 26(9): 2733-2742, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28918500

RESUMEN

PURPOSE: To determine (1) whether a correlation exists between tibial tubercle-posterior cruciate ligament (TT-PCL) and tibial tubercle-trochlear groove (TT-TG) distances in patellar instability patients; (2) reliability when measuring TT-PCL distance; (3) whether TT-PCL distances measured on MRI are equivalent to those on CT; and (4) whether a correlation exists between TT-PCL distance and number of instability events or recurrence of instability following stabilization surgery. METHODS: A systematic review was performed using PRISMA guidelines. Clinical studies investigating the relationships of TT-PCL with TT-TG on CT and/or MRI in patellar instability patients were sought. English language studies with Levels of evidence I-IV were eligible for inclusion. RESULTS: Four studies (285 subjects [300 knees] with patellar instability [74.2% female; mean age 26.1 ± 8.2 years]; 114 controls [144 knees; 77% female; mean age 23.1 years]) were included. Mean TT-PCL of instability and control groups was 21.1 ± 4.1 and 18.8 ± 4.0 mm (p < 0.0001), respectively. Two studies reported significant positive (strong and moderate) correlations between TT-PCL and TT-TG MRI measurements in instability patients. All four investigations reported excellent interobserver and intraobserver reliability in MRI measurement of TT-PCL distance. No study compared TT-PCL distances on MRI and CT. No study assessed correlation between TT-PCL distance and number of instability events or recurrence of instability after surgery. CONCLUSION: A moderate-to-strong positive correlation exists between TT-PCL and TT-TG measurements taken from MRIs of patellar instability patients. There is excellent interobserver and intraobserver reliability when taking TT-PCL measurements using MRI. This review advocates use of a new pathologic TT-PCL threshold of 21 mm. LEVEL OF EVIDENCE: Level III, systematic review of Level II-III studies.


Asunto(s)
Inestabilidad de la Articulación/cirugía , Articulación Patelofemoral/fisiopatología , Ligamento Cruzado Posterior/patología , Tibia/patología , Humanos , Articulación de la Rodilla/patología , Imagen por Resonancia Magnética , Estudios Observacionales como Asunto , Variaciones Dependientes del Observador , Luxación de la Rótula/patología , Recurrencia , Reproducibilidad de los Resultados
16.
Arthroscopy ; 34(3): 943-950, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29162364

RESUMEN

PURPOSE: To perform a systematic review to determine if there is (1) an association between decreased hip internal rotation and anterior cruciate ligament (ACL) tear rates; (2) an association between radiographic femoroacetabular impingement (FAI) and ACL tear rates; and (3) biomechanical evidence demonstrating increased strain in the ACL of patients with decreased hip internal rotation. METHODS: A systematic review was performed using Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Studies investigating relationships between hip motion, hip radiographs, and ACL tear were sought. Studies with Levels of evidence I-IV were eligible for inclusion. Study methodology/evidence were evaluated using Methodological Index for Non-Randomized Studies (MINORS), Strengthening the Reporting of Observational Studies in Epidemiology (STROBE), and Grading of Recommendations Assessment, Development, and Evaluation (GRADE) criteria. RESULTS: Eleven studies were analyzed (2 cadaveric in vitro models, 8 clinical studies measuring hip internal rotation (2 concurrently assessing radiographic FAI), and 1 clinical study assessing radiographic FAI alone). Mean MINORS, STROBE, and GRADE for the studies was 82.4%, 20.9 out of 22, and "low," respectively. A total of 959 subjects (84.8% male; mean age 23.6 ± 3.8 years) were analyzed. Overall, 378 subjects sustained 427 ACL tears (399 primary ACL ruptures, 28 reruptures). Six of 8 clinical studies identified a significant association between limited rotation (internal rotation [IR; loss greater than 10°-20°], external rotation [ER], or combined IR + ER [loss greater than 20°]) and ACL tears. Two studies found an association between ACL ruptures and radiographic cam/pincer impingement. Two cadaveric models found a significant association between ACL strain and limited hip internal rotation. CONCLUSIONS: This systematic review identified a significant association between ACL tear and both limited hip rotation and radiographic FAI. LEVEL OF EVIDENCE: Level IV, systematic review of Levels II-IV studies.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/etiología , Lesiones del Ligamento Cruzado Anterior/fisiopatología , Traumatismos en Atletas/etiología , Traumatismos en Atletas/fisiopatología , Pinzamiento Femoroacetabular/diagnóstico por imagen , Pinzamiento Femoroacetabular/fisiopatología , Cadera/fisiopatología , Rango del Movimiento Articular/fisiología , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Traumatismos en Atletas/diagnóstico por imagen , Fenómenos Biomecánicos , Pinzamiento Femoroacetabular/complicaciones , Humanos , Radiografía , Factores de Riesgo , Rotación
17.
Arthroscopy ; 33(12): 2248-2254, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29066268

RESUMEN

PURPOSE: To use simulated arthroscopic knot tying to assess (1) whether epithelial cells from the surgeon's hands were transmitted to the suture and (2) whether the number of knots tied or the presence of glove tears would correlate with the number of cells transmitted. METHODS: Knots were tied in a simulated arthroscopic environment using a nonabsorbable No. 2 suture over a metal hook. The surgeon was double gloved for each knot tied. For each "anchor," a surgeon's knot was tied, followed by 3 reversed half-hitches on alternating posts. Multiple skin lacerations were sustained by the surgeon during each knot-tying session. Gloves were collected after tying 2, 4, or 6 anchors. Gloves were tested for perforation by (1) electroconductivity and (2) saline solution load testing. Cytopathologic ThinPrep analysis was applied and allowed for the number of epithelial cells found on each suture (within 10 high-powered fields) to be counted. Statistical analysis included analysis of variance and logistic regression. RESULTS: There was no significant difference in the number of epithelial cells identified in any of the groups compared with the negative control groups (P > .05) or with each other (P > .05). Glove tears were present in 3.3% of gloves (50% in inner and 50% in outer gloves) and 1.7% of gloves (50% in inner and 50% in outer gloves) by electroconductivity and saline solution load testing, respectively. There was no significant association between glove tears and the number of epithelial cells found on the suture (P > .05). CONCLUSIONS: Epithelial cells were transmitted to the suture during simulated arthroscopic knot tying. However, despite multiple skin lacerations produced during knot-tying sessions, the number of cells transmitted was not significantly different when compared with the negative controls. The number of cells transmitted did not correlate with the number of knots tied and/or the presence of glove tears. CLINICAL RELEVANCE: Skin lacerations on the surgeon's fingers are often noted after arthroscopic knot tying. However, despite these skin lacerations, no skin tissue is transferred across the surgical gloves to the suture itself.


Asunto(s)
Artroscopía , Células Epiteliales/citología , Guantes Quirúrgicos , Piel/lesiones , Suturas , Recuento de Células , Falla de Equipo , Humanos , Laceraciones , Cirujanos
18.
Arthroscopy ; 33(10): 1804-1809, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28969816

RESUMEN

PURPOSE: To determine if (1) absorbed radiation dose and (2) fluoroscopy time decreased with experience over the first 100 cases of a single surgeon's hip arthroscopy practice. METHODS: Subjects who underwent hip arthroscopy for symptomatic femoroacetabular impingement and labral injury were eligible for analysis. Inclusion criteria included the first 100 subjects who underwent hip arthroscopy by a single surgeon (December 2013 to December 2014). Subject demographics, procedure details, fluoroscopy absorbed dose (milligray [mGy]), and time were recorded. Subjects were categorized by date of surgery to one of 4 possible groups (25 per group). One-way analysis of variance was used to determine if a significant difference in dose (mGy) or time was present between groups. Simple linear regression analysis was performed to determine the relation between case number and both radiation dose and fluoroscopy time. RESULTS: Subjects underwent labral repair (n = 93), cam osteoplasty (n = 90), and pincer acetabuloplasty (n = 65). There was a significant (P < .001 for both) linear regression between case number and both radiation dose and fluoroscopy time. A significant difference in mGy was observed between groups, group 1 the highest and group 4 the lowest amounts of radiation (P = .003). Comparing individual groups, group 4 was found to have a significantly lower amount of radiation than group 1 (P = .002), though it was not significantly lower than that of group 2 (P = .09) or group 3 (P = .08). A significant difference in fluoroscopy time was observed between groups, group 1 the highest and group 4 the lowest times (P = .05). Comparing individual groups, group 4 was found to have a significantly lower fluoroscopy time than group 1 (P = .039). Correction for weight, height, and body mass index all revealed the same findings: significant (P < .05) differences in both dose and time across groups. CONCLUSIONS: The absorbed dose of radiation and fluoroscopy time decreased significantly over the first 100 cases of a single surgeon's hip arthroscopy practice learning curve. LEVEL OF EVIDENCE: Level IV, therapeutic, retrospective, noncomparative case series.


Asunto(s)
Artroscopía , Fluoroscopía , Curva de Aprendizaje , Adulto , Cartílago Articular/lesiones , Cartílago Articular/cirugía , Femenino , Pinzamiento Femoroacetabular/cirugía , Articulación de la Cadera/cirugía , Humanos , Modelos Lineales , Masculino , Dosis de Radiación , Estudios Retrospectivos , Factores de Tiempo
19.
Arthroscopy ; 33(8): 1560-1566, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28499922

RESUMEN

PURPOSE: To critically analyze the "lever test" in detecting anterior cruciate ligament (ACL) tears and to compare its accuracy with the Lachman, anterior drawer (AD), and pivot shift tests. METHODS: From June 2014 to June 2015, 91 subjects were analyzed. Inclusion criteria were subjects aged 16 to 60 years, presenting after a knee injury with subjective swelling, or an objective effusion and an uninjured normal contralateral knee for comparison. Exclusion criteria included previous knee ligamentous reconstruction, fracture of the distal femur or proximal tibia, bilateral knee injuries, or known cruciate ligament tear. The Lachman, AD, pivot shift, and lever tests were performed in the office by 2 board-certified orthopaedic surgeons with patient awake. Examiners were blinded to the presence or absence of ACL injury. Magnetic resonance imaging was used to determine injury. Sensitivity, specificity, and accuracy were evaluated for all 4 tests. Accuracy was compared using χ-square and receiver operator curves. RESULTS: Average subject age was 28 ± 11 years (61 males, 30 females). Seventy-one (79%) had ACL tears diagnosed by magnetic resonance imaging. The sensitivity, specificity, and accuracy of the lever test were 83%, 80%, and 82%, respectively. Accuracy was not statistically different from the Lachman, AD, and pivot shift tests (P = .78, .99, .07, respectively). Subanalyses were performed based on the presence of another ligament tear, timing of injury, and the presence of a meniscus tear. Although the groups were smaller and thus underpowered, the results were reported. Neither the presence of another ligament tear nor the timing of the injury affected accuracy (P = .62 and P = .47); however, the presence of a meniscus tear decreased its accuracy (P = .003). CONCLUSIONS: The lever test showed high sensitivity, specificity, and overall accuracy in the detection of ACL tears. The accuracy of the lever test was not significantly different from the Lachman, AD, or pivot shift tests. LEVEL OF EVIDENCE: Level II, prospective comparative study.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/diagnóstico , Inestabilidad de la Articulación/diagnóstico , Articulación de la Rodilla , Adolescente , Adulto , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Femenino , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/cirugía , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Examen Físico/métodos , Estudios Prospectivos , Rotura/diagnóstico , Rotura/diagnóstico por imagen , Rotura/cirugía , Sensibilidad y Especificidad , Adulto Joven
20.
Orthopedics ; 40(3): e563-e566, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28358977

RESUMEN

Proximal fifth metatarsal fractures, zones II and III, are commonly treated surgically, especially in elite athletes. Intramedullary screw fixation remains the most used construct despite nonunion and refracture. High tensile forces on the plantar-lateral aspect of the fifth metatarsal are difficult to control, and intramedullary screw fixation depends on ideal screw position, length, and width. The authors present a plantar plating technique with cancellous bone autograft for zones II and III proximal fifth metatarsal fractures. Rotational instability and plantar-lateral gapping are resisted by applying a compression plate to the tension side of the fracture, eliminating causes for failure. [Orthopedics. 2017; 40(3):e563-e566.].


Asunto(s)
Atletas , Tornillos Óseos , Traumatismos de los Pies/cirugía , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Huesos Metatarsianos/cirugía , Trasplante Autólogo , Traumatismos del Tobillo , Placas Óseas , Hueso Esponjoso , Epífisis , Humanos , Traumatismos de la Rodilla
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...