Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 793
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38984693

RESUMEN

AIMS: To evaluate the prognostic implications of left atrial reservoir strain-defined diastolic dysfunction (LARS-DD) grade in patients undergoing TAVI for severe aortic stenosis (AS) and to determine if post-TAVI LARS was more closely associated with new-onset atrial fibrillation than pre-TAVI LARS. METHODS AND RESULTS: Pre-TAVI LARS-DD was evaluated by speckle-tracking echocardiography and was assigned as grade 0 to 1 (LARS≥24%), grade 2 (LARS≥19 to <24%) and grade 3 (LARS<19%). Patients were followed-up for the primary endpoint of all-cause mortality from the date of TAVI. For the secondary endpoint, patients with pre- and post-TAVI LARS measurements and no history of atrial fibrillation were evaluated for the occurrence of new-onset atrial fibrillation. A total of 601 patients (median age 81 [76-85] years, 53% male) were included. Overall, 169 patients (28%) were LARS-DD grade 0/1, 96 patients (16%) were LARS-DD grade 2 and 336 (56%) were LARS-DD grade 3. Over a median follow-up of 40 (IQR 26-58) months, a total of 258 (43%) patients died. In a comprehensive multivariable Cox regression model, LARS-DD grade was independently associated with all-cause mortality (adjusted HR 1.28 per one-grade increase, 95%CI 1.07-1.53, P=0.007). For the secondary endpoint of new-onset atrial fibrillation, a total of 285 patients were evaluated. Post-TAVI LARS (SDHR 1.14 per 1%<20%, 95%CI 1.05-1.23, P=0.0009), but not pre-TAVI LARS (P=0.93) was independently associated with new-onset atrial fibrillation. CONCLUSIONS: Increasing LARS-DD grade was independently associated with long-term post-TAVI survival in patients with severe AS. Post-TAVI LARS was closely related to the occurrence of new-onset atrial fibrillation.

2.
ESC Heart Fail ; 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38894578

RESUMEN

AIMS: In low-risk patients with severe aortic stenosis (AS), sutureless surgical aortic valve replacement (SU-SAVR) may be an alternative to transcatheter aortic valve implantation (TAVI). The risk of heart failure hospitalization (HFH) after aortic valve replacement (AVR) in this population is incompletely characterized. This study aims to investigate the incidence, predictors, and outcomes of HFH in patients undergoing SU-SAVR versus TAVI. METHODS AND RESULTS: Patients referred for AVR between 2013 and 2020 at two centres were consecutively included. The decision for SU-SAVR or TAVI was determined by a multidisciplinary Heart Team. Cox regression and competing risk analysis were conducted to assess adverse events. Of 594 patients (mean age 77.5 ± 6.4, 59.8% male), 424 underwent SU-SAVR, while 170 underwent TAVI. Following a mean follow-up of 34.1 ± 23.1 months, HFH occurred in 112 (27.8%) SU-SAVR patients and in 8 (4.8%) TAVI patients (P < 0.001). The SU-SAVR cohort exhibited higher all-cause mortality (138 [32.5%] patients compared with 30 [17.6%] in the TAVI cohort [P < 0.001]). These differences remained significant after sensitivity analyses with 1:1 propensity score matching for baseline variables. SU-SAVR with HFH was associated with increased all-cause mortality (61.6% vs. 23.1%, P < 0.001). Independent associates of HFH in SU-SAVR patients included diabetes, atrial fibrillation, chronic obstructive pulmonary disease, lower glomerular filtration rate and lower left ventricular ejection fraction. SU-SAVR patients with HFH had a 12-month LVEF of 59.4 ± 12.7. CONCLUSIONS: In low-risk AS, SU-SAVR is associated with a higher risk of HFH and all-cause mortality compared to TAVI. In patients with severe AS candidate to SU-SAVR or TAVI, TAVI may be the preferred intervention.

3.
Reprod Fertil Dev ; 36(10): NULL, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38905444

RESUMEN

Context The Rsa I polymorphism of the melatonin receptor MTNR1A gene affects seasonal reproduction in sheep, but its effect on ram spermatozoa and their response to melatonin is unknown. Aims This study aims to evaluate whether Rsa I polymorphism of the MTNR1A gene influences the response of ram spermatozoa to in vitro added melatonin. Methods Spermatozoa from rams carrying different Rsa I allelic variants were incubated with melatonin in a TALP medium or a capacitation-triggering medium during the reproductive and non-reproductive seasons. After incubation, sperm motility, membrane integrity, mitochondria activity, oxidative damage, apoptotic markers and capacitation status were assessed. Key results In the reproductive season, the T/T genotype was related to some adverse effects of melatonin when spermatozoa were incubated in TALP medium, whereas the C/C genotype was linked with adverse effects when the hormone was added in a capacitation-triggering medium. The decapacitating effect of melatonin on spermatozoa was also different depending on genotype. Conclusions The melatonin effect on spermatozoa from rams carrying different Rsa I genotypes differed depending on the season and the medium. Implications The knowledge of the Rsa I allelic variant of the MTNR1A gene of rams could be helpful when carrying out in vitro reproductive techniques in the ovine species.


Asunto(s)
Melatonina , Estaciones del Año , Motilidad Espermática , Espermatozoides , Melatonina/farmacología , Animales , Masculino , Espermatozoides/efectos de los fármacos , Ovinos , Motilidad Espermática/efectos de los fármacos , Motilidad Espermática/genética , Receptor de Melatonina MT1/genética , Receptor de Melatonina MT1/metabolismo , Polimorfismo Genético , Alelos , Capacitación Espermática/efectos de los fármacos , Capacitación Espermática/genética , Genotipo
4.
Arch. cardiol. Méx ; 94(2): 219-239, Apr.-Jun. 2024. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1556919

RESUMEN

resumen está disponible en el texto completo


Abstract This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38772454

RESUMEN

BACKGROUND: This study sought to explore the prevalence and clinical utility of different patterns of multiorgan venous congestion as assessed by the venous excess ultrasound (VExUS) score in hospitalized patients with acute heart failure (HF). METHODS: Consecutive patients admitted for acute HF were prospectively enrolled. Inferior vena cava diameter, hepatic vein, portal vein, and renal vein Doppler waveforms were assessed at admission, and patients were stratified based on VExUS score from 0 to 3, with higher values indicating worse congestion. The clinical score Get with the Guidelines (GWTG)-HF for predicting in-hospital mortality in HF was evaluated. In-hospital mortality was recorded. RESULTS: Two hundred ninety patients admitted with acute HF were included, and 114 (39%) of them were classified as VExUS score 3, which was the most prevalent group. Patients with VExUS score 3 suffered more frequently from chronic atrial fibrillation, chronic kidney disease, and anemia. Parameters independently associated with VExUS score 3 were higher mean E/e' ratio, larger right ventricular size, severe tricuspid regurgitation, and impaired right atrial function. A VExUS score of 3 was associated with in-hospital mortality (odds ratio, 8.03; 95% CI [2.25-28.61], P = .001). The addition of VExUS score on top of the GWTG-HF score improved the predictability of the model (Δx2 = +8.44, P = .03) for in-hospital mortality, whereas other indices of venous congestion (right atrial function, inferior vena cava size) did not. CONCLUSIONS: Patients admitted with acute HF commonly had severe venous congestion based on the VExUS score. The VExUS score improved the prediction of in-hospital mortality compared with other indices of venous congestion.

6.
Reprod Fertil Dev ; 362024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38753960

RESUMEN

Context Several polymorphisms in the melatonin receptor 1A gene (MTNR1A ) have been related to reproductive performance in ovine. Aims To investigate the effect of the Rsa I and Mnl I polymorphisms on ram seminal quality. Methods Eighteen Rasa Aragonesa rams were genotyped for the Rsa I (C/C, C/T, T/T) and Mnl I (G/G, G/A, A/A) allelic variants of the MTNR1A gene. Individual ejaculates were analysed once a month throughout the whole year. Sperm motility, morphology, membrane integrity, levels of reactive oxygen species (ROS), phosphatidylserine (PS) inversion, DNA fragmentation and capacitation status were assessed. The effect of the season and polymorphisms on seminal quality was evaluated by mixed ANOVA. Key results Both polymorphisms had an effect on membrane integrity and viable spermatozoa with low levels of ROS and without PS translocation, and Rsa I also on motile and DNA-intact spermatozoa. An interaction between both polymorphisms was found, pointing to a negative effect on seminal quality of carrying the T or A allele in homozygosity. Differences were higher in the reproductive than in the non-reproductive season. Conclusions Mutations substituting C by T and G by A at Rsa I and Mnl I polymorphic sites, respectively, in the MTNR1A gene in rams could decrease the seminal quality. Implications Genotyping of rams based on melatonin receptor 1A could be a powerful tool in sire selection.


Asunto(s)
Receptor de Melatonina MT1 , Motilidad Espermática , Espermatozoides , Masculino , Animales , Receptor de Melatonina MT1/genética , Receptor de Melatonina MT1/metabolismo , Espermatozoides/metabolismo , Motilidad Espermática/genética , Ovinos/genética , Genotipo , Análisis de Semen/veterinaria , Polimorfismo Genético , Especies Reactivas de Oxígeno/metabolismo , Fragmentación del ADN , Polimorfismo de Nucleótido Simple
7.
Eur J Clin Invest ; : e14241, 2024 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767226

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38795108

RESUMEN

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6 and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).

11.
Circ Arrhythm Electrophysiol ; 17(5): e012517, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38666379

RESUMEN

BACKGROUND: Sacubitril/valsartan (Sac/Val) is superior to angiotensin-converting enzyme inhibitors in reducing the risk of heart failure hospitalization and cardiovascular death, but its mechanistic data on myocardial scar after myocardial infarction (MI) are lacking. The objective of this work was to assess the effects of Sac/Val on inflammation, fibrosis, electrophysiological properties, and ventricular tachycardia inducibility in post-MI scar remodeling in swine. METHODS: After MI, 22 pigs were randomized to receive ß-blocker (BB; control, n=8) or BB+Sac/Val (Sac/Val, n=9). The systemic immune response was monitored. Cardiac magnetic resonance data were acquired at 2-day and 29-day post MI to assess ventricular remodeling. Programmed electrical stimulation and high-density mapping were performed at 30-day post MI to assess ventricular tachycardia inducibility. Myocardial samples were collected for histological analysis. RESULTS: Compared with BB, BB+Sac/Val reduced acute circulating leukocytes (P=0.009) and interleukin-12 levels (P=0.024) at 2-day post MI, decreased C-C chemokine receptor type 2 expression in monocytes (P=0.047) at 15-day post MI, and reduced scar mass (P=0.046) and border zone mass (P=0.043). It also lowered the number and mass of border zone corridors (P=0.009 and P=0.026, respectively), scar collagen I content (P=0.049), and collagen I/III ratio (P=0.040). Sac/Val reduced ventricular tachycardia inducibility (P=0.034) and the number of deceleration zones (P=0.016). CONCLUSIONS: After MI, compared with BB, BB+Sac/Val was associated with reduced acute systemic inflammatory markers, reduced total scar and border zone mass on late gadolinium-enhanced magnetic resonance imaging, and lower ventricular tachycardia inducibility.


Asunto(s)
Aminobutiratos , Compuestos de Bifenilo , Cicatriz , Modelos Animales de Enfermedad , Combinación de Medicamentos , Infarto del Miocardio , Miocardio , Taquicardia Ventricular , Valsartán , Remodelación Ventricular , Animales , Valsartán/farmacología , Aminobutiratos/farmacología , Infarto del Miocardio/tratamiento farmacológico , Infarto del Miocardio/fisiopatología , Infarto del Miocardio/complicaciones , Infarto del Miocardio/patología , Cicatriz/fisiopatología , Cicatriz/etiología , Cicatriz/patología , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/metabolismo , Remodelación Ventricular/efectos de los fármacos , Compuestos de Bifenilo/farmacología , Miocardio/patología , Miocardio/metabolismo , Antiinflamatorios/farmacología , Tetrazoles/farmacología , Fibrosis , Porcinos , Antiarrítmicos/farmacología , Femenino , Masculino , Factores de Tiempo , Imagen por Resonancia Cinemagnética , Frecuencia Cardíaca/efectos de los fármacos
15.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38441886

RESUMEN

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia
16.
Int J Cardiol ; 406: 131996, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38555056

RESUMEN

OBJECTIVE: Management of patients with severe aortic stenosis (AS) may differ according to the patient sex. This study aimed to describe patterns of aortic valve replacement (AVR) for severe AS across Europe, including stratification by sex. METHODS: Procedure volume data for surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) for six years (2015-2020) were extracted from national databases for Austria, Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland and stratified by sex. Patients per million population (PPM) undergoing AVR per year were calculated using population estimates from Eurostat. RESULTS: Between 2015 and 2019, AVR procedures grew at an average annual rate of 3.9%. In 2020, the average total PPM undergoing AVR across all countries was 339, with 51% of procedures being TAVI and 49% SAVR. AVR PPM varied widely between countries, with the highest and lowest in Germany and Poland, respectively. The average total PPM was higher for men than women (423 vs. 258), but a higher proportion of women (62%) than men (44%) received TAVI. The proportion of TAVI among total AVR procedures increased with age, with an overall average of 96% of men and 98% of women aged ≥85 years receiving TAVI; however, adoption of TAVI varied by country. CONCLUSIONS: The analysis of temporal trends in the adoption of TAVI vs. SAVR across Europe showed significant variations. Despite the higher use of TAVI vs. SAVR in women, overall rates of AV intervention in women were lower compared to men.


Asunto(s)
Estenosis de la Válvula Aórtica , Humanos , Femenino , Masculino , Europa (Continente)/epidemiología , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Anciano de 80 o más Años , Factores Sexuales , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Válvula Aórtica/cirugía , Persona de Mediana Edad
18.
Eur Heart J ; 45(13): 1104-1115, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38366821

RESUMEN

Research performed in Europe has driven cardiovascular device innovation. This includes, but is not limited to, percutaneous coronary intervention, cardiac imaging, transcatheter heart valve implantation, and device therapy of cardiac arrhythmias and heart failure. An important part of future medical progress involves the evolution of medical technology and the ongoing development of artificial intelligence and machine learning. There is a need to foster an environment conducive to medical technology development and validation so that Europe can continue to play a major role in device innovation while providing high standards of safety. This paper summarizes viewpoints on the topic of device innovation in cardiovascular medicine at the European Society of Cardiology Cardiovascular Round Table, a strategic forum for high-level dialogue to discuss issues related to the future of cardiovascular health in Europe. Devices are developed and improved through an iterative process throughout their lifecycle. Early feasibility studies demonstrate proof of concept and help to optimize the design of a device. If successful, this should ideally be followed by randomized clinical trials comparing novel devices vs. accepted standards of care when available and the collection of post-market real-world evidence through registries. Unfortunately, standardized procedures for feasibility studies across various device categories have not yet been implemented in Europe. Cardiovascular imaging can be used to diagnose and characterize patients for interventions to improve procedural results and to monitor devices long term after implantation. Randomized clinical trials often use cardiac imaging-based inclusion criteria, while less frequently trials randomize patients to compare the diagnostic or prognostic value of different modalities. Applications using machine learning are increasingly important, but specific regulatory standards and pathways remain in development in both Europe and the USA. Standards are also needed for smart devices and digital technologies that support device-driven biomonitoring. Changes in device regulation introduced by the European Union aim to improve clinical evidence, transparency, and safety, but they may impact the speed of innovation, access, and availability. Device development programmes including dialogue on unmet needs and advice on study designs must be driven by a community of physicians, trialists, patients, regulators, payers, and industry to ensure that patients have access to innovative care.


Asunto(s)
Cardiología , Procedimientos Quirúrgicos Torácicos , Humanos , Inteligencia Artificial , Diagnóstico por Imagen , Técnicas de Imagen Cardíaca
19.
Arch Cardiol Mex ; 94(2): 219-239, 2024 02 07.
Artículo en Español | MEDLINE | ID: mdl-38325117

RESUMEN

This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.


Este consenso de nomenclatura y clasificación para la válvula aórtica bicúspide congénita y su aortopatía está basado en la evidencia y destinado a ser utilizado universalmente por médicos (tanto pediatras como de adultos), médicos ecocardiografistas, especialistas en imágenes avanzadas cardiovasculares, cardiólogos intervencionistas, cirujanos cardiovasculares, patólogos, genetistas e investigadores que abarcan estas áreas de investigación clínica y básica. Siempre y cuando se disponga de nueva investigación clave y de referencia, este consenso internacional puede estar sujeto a cambios de acuerdo con datos basados en la evidencia1.

20.
Eur J Heart Fail ; 26(2): 483-501, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38269474

RESUMEN

Implantable devices form an integral part of the management of patients with heart failure (HF) and provide adjunctive therapies in addition to cornerstone drug treatment. Although the number of these devices is growing, only few are supported by robust evidence. Current devices aim to improve haemodynamics, improve reverse remodelling, or provide electrical therapy. A number of these devices have guideline recommendations and some have been shown to improve outcomes such as cardiac resynchronization therapy, implantable cardioverter-defibrillators and long-term mechanical support. For others, more evidence is still needed before large-scale implementation can be strongly advised. Of note, devices and drugs can work synergistically in HF as improved disease control with devices can allow for further optimization of drug therapy. Therefore, some devices might already be considered early in the disease trajectory of HF patients, while others might only be reserved for advanced HF. As such, device therapy should be integrated into HF care programmes. Unfortunately, implementation of devices, including those with the greatest evidence, in clinical care pathways is still suboptimal. This clinical consensus document of the Heart Failure Association (HFA) and European Heart Rhythm Association (EHRA) of the European Society of Cardiology (ESC) describes the physiological rationale behind device-provided therapy and also device-guided management, offers an overview of current implantable device options recommended by the guidelines and proposes a new integrated model of device therapy as a part of HF care.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...