Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Neurosurgery ; 93(6): 1296-1304, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37319401

RESUMEN

BACKGROUND AND OBJECTIVES: Peripheral nerve injuries resulting in a nerve defect require surgical repair. The gold standard of autograft (AG) has several limitations, and therefore, new alternatives must be developed. The main objective of this study was to assess nerve regeneration through a long gap nerve injury (50 mm) in the peroneal nerve of sheep with a decellularized nerve allograft (DCA). METHODS: A 5-cm long nerve gap was made in the peroneal nerve of sheep and repaired using an AG or using a DCA. Functional tests were performed once a month and electrophysiology and echography evaluations at 6.5 and 9 months postsurgery. Nerve grafts were harvested at 9 months for immunohistochemical and morphological analyses. RESULTS: The decellularization protocol completely eliminated the cells while preserving the extracellular matrix of the nerve. No significant differences were observed in functional tests of locomotion and pain response. Reinnervation of the tibialis anterior muscles occurred in all animals, with some delay in the DCA group compared with the AG group. Histology showed a preserved fascicular structure in both AG and DCA; however, the number of axons distal to the nerve graft was higher in AG than in DCA. CONCLUSION: The decellularized graft assayed supported effective axonal regeneration when used to repair a 5-cm long gap in the sheep. As expected, a delay in functional recovery was observed compared with the AG because of the lack of Schwann cells.


Asunto(s)
Traumatismos de los Nervios Periféricos , Ovinos , Animales , Traumatismos de los Nervios Periféricos/cirugía , Traumatismos de los Nervios Periféricos/patología , Nervio Peroneo/lesiones , Células de Schwann , Trasplante Autólogo/métodos , Músculo Esquelético/inervación , Regeneración Nerviosa/fisiología , Nervio Ciático/patología , Nervios Periféricos/fisiología
2.
J Neural Eng ; 20(4)2023 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-37369194

RESUMEN

Objective.Peripheral nerve interfaces have the potential to restore sensory, motor, and visceral functions. In particular, intraneural interfaces allow targeting deep neural structures with high selectivity, even if their performance strongly depends upon the implantation procedure and the subject's anatomy. Currently, few alternatives exist for the determination of the target subject structural and functional anatomy, and statistical characterizations from cadaveric samples are limited because of their high cost. We propose an optimization workflow that can guide both the pre-surgical planning and the determination of maximally selective multisite stimulation protocols for implants consisting of several intraneural electrodes, and we characterize its performance in silico. We show that the availability of structural and functional information leads to very high performances and allows taking informed decisions on neuroprosthetic design.Approach.We employ hybrid models (HMs) of neuromodulation in conjunction with a machine learning-based surrogate model to determine fiber activation under electrical stimulation, and two steps of optimization through particle swarm optimization to optimize in silico implant geometry, implantation and stimulation protocols using morphological data from the human median nerve at a reduced computational cost.Main results.Our method allows establishing the optimal geometry of multi-electrode transverse intra-fascicular multichannel electrode implants, the optimal number of electrodes to implant, their optimal insertion, and a set of multipolar stimulation protocols that lead in silico to selective activation of all the muscles innervated by the human median nerve.Significance.We show how to use effectively HMs for optimizing personalized neuroprostheses for motor function restoration. We provide in-silico evidences about the potential of multipolar stimulation to increase greatly selectivity. We also show that the knowledge of structural and functional anatomies of the target subject leads to very high selectivity and motivate the development of methods for theirin vivocharacterization.


Asunto(s)
Nervio Mediano , Nervios Periféricos , Humanos , Electrodos Implantados , Electrodos , Nervios Periféricos/fisiología , Estimulación Eléctrica/métodos , Biofisica
3.
Int J Mol Sci ; 24(2)2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36674848

RESUMEN

Despite advances in microsurgery, full functional recovery of severe peripheral nerve injuries is not commonly attained. The sheep appears as a good preclinical model since it presents nerves with similar characteristics to humans. In this study, we induced 5 or 7 cm resection in the peroneal nerve and repaired with an autograft. Functional evaluation was performed monthly. Electromyographic and ultrasound tests were performed at 6.5 and 9 months postoperation (mpo). No significant differences were found between groups with respect to functional tests, although slow improvements were seen from 5 mpo. Electrophysiological tests showed compound muscle action potentials (CMAP) of small amplitude at 6.5 mpo that increased at 9 mpo, although they were significantly lower than the contralateral side. Ultrasound tests showed significantly reduced size of tibialis anterior (TA) muscle at 6.5 mpo and partially recovered size at 9 mpo. Histological evaluation of the grafts showed good axonal regeneration in all except one sheep from autograft 7 cm (AG7) group, while distal to the graft there was a higher number of axons than in control nerves. The results indicate that sheep nerve repair is a useful model for investigating long-gap peripheral nerve injuries.


Asunto(s)
Traumatismos de los Nervios Periféricos , Humanos , Ovinos , Animales , Traumatismos de los Nervios Periféricos/terapia , Nervios Periféricos/fisiología , Nervio Peroneo , Axones , Regeneración Nerviosa/fisiología , Nervio Ciático/lesiones
4.
Cells ; 11(24)2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36552838

RESUMEN

Decellularized nerve allografts (DC) are an alternative to autografts (AG) for repairing severe peripheral nerve injuries. We have assessed a new DC provided by VERIGRAFT. The decellularization procedure completely removed cellularity while preserving the extracellular matrix. We first assessed the DC in a 15 mm gap in the sciatic nerve of rats, showing slightly delayed but effective regeneration. Then, we assayed the DC in a 70 mm gap in the peroneal nerve of sheep compared with AG. Evaluation of nerve regeneration and functional recovery was performed by clinical, electrophysiology and ultrasound tests. No significant differences were found in functional recovery between groups of sheep. Histology showed a preserved fascicular structure in the AG while in the DC grafts regenerated axons were grouped in small units. In conclusion, the DC was permissive for axonal regeneration and allowed to repair a 70 mm long gap in the sheep nerve.


Asunto(s)
Tejido Nervioso , Nervio Ciático , Ratas , Animales , Ovinos , Nervio Ciático/patología , Trasplante Homólogo/métodos , Trasplante Autólogo/métodos , Autoinjertos/trasplante , Regeneración Nerviosa/fisiología
5.
Brain ; 145(11): 3859-3871, 2022 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-35953082

RESUMEN

One outstanding challenge for machine learning in diagnostic biomedical imaging is algorithm interpretability. A key application is the identification of subtle epileptogenic focal cortical dysplasias (FCDs) from structural MRI. FCDs are difficult to visualize on structural MRI but are often amenable to surgical resection. We aimed to develop an open-source, interpretable, surface-based machine-learning algorithm to automatically identify FCDs on heterogeneous structural MRI data from epilepsy surgery centres worldwide. The Multi-centre Epilepsy Lesion Detection (MELD) Project collated and harmonized a retrospective MRI cohort of 1015 participants, 618 patients with focal FCD-related epilepsy and 397 controls, from 22 epilepsy centres worldwide. We created a neural network for FCD detection based on 33 surface-based features. The network was trained and cross-validated on 50% of the total cohort and tested on the remaining 50% as well as on 2 independent test sites. Multidimensional feature analysis and integrated gradient saliencies were used to interrogate network performance. Our pipeline outputs individual patient reports, which identify the location of predicted lesions, alongside their imaging features and relative saliency to the classifier. On a restricted 'gold-standard' subcohort of seizure-free patients with FCD type IIB who had T1 and fluid-attenuated inversion recovery MRI data, the MELD FCD surface-based algorithm had a sensitivity of 85%. Across the entire withheld test cohort the sensitivity was 59% and specificity was 54%. After including a border zone around lesions, to account for uncertainty around the borders of manually delineated lesion masks, the sensitivity was 67%. This multicentre, multinational study with open access protocols and code has developed a robust and interpretable machine-learning algorithm for automated detection of focal cortical dysplasias, giving physicians greater confidence in the identification of subtle MRI lesions in individuals with epilepsy.


Asunto(s)
Epilepsias Parciales , Epilepsia , Malformaciones del Desarrollo Cortical , Humanos , Estudios Retrospectivos , Malformaciones del Desarrollo Cortical/complicaciones , Malformaciones del Desarrollo Cortical/diagnóstico por imagen , Epilepsia/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Aprendizaje Automático , Epilepsias Parciales/diagnóstico por imagen
6.
Eur Eat Disord Rev ; 30(4): 353-363, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35322504

RESUMEN

BACKGROUND: Up to 20% of the cases of anorexia nervosa (AN) are chronic and treatment-resistant. Recently, the efficacy of deep brain stimulation (DBS) for severe cases of AN has been explored, with studies showing an improvement in body mass index and other psychiatric outcomes. While the effects of DBS on cognitive domains have been studied in patients with other neurological and psychiatric conditions so far, no evidence has been gathered in AN. METHODS: Eight patients with severe, chronic, treatment-resistant AN received DBS either to the nucleus accumbens (NAcc) or subcallosal cingulate (SCC; four subjects on each target). A comprehensive battery of neuropsychological and clinical outcomes was used before and 6-month after surgery. FINDINGS: Although Body Mass Index (BMI) did not normalise, statistically significant improvements in BMI, quality of life, and performance on cognitive flexibility were observed after 6 months of DBS. Changes in BMI were related to a decrease in depressive symptoms and an improvement in memory functioning. INTERPRETATION: These findings, although preliminary, support the use of DBS in AN, pointing to its safety, even for cognitive functioning; improvements of cognitive flexibility are reported. DBS seems to exert changes on cognition and mood that accompany BMI increments. Further studies are needed better to determine the impact of DBS on cognitive functions.


Asunto(s)
Anorexia Nerviosa , Estimulación Encefálica Profunda , Anorexia Nerviosa/psicología , Anorexia Nerviosa/terapia , Índice de Masa Corporal , Cognición/fisiología , Estimulación Encefálica Profunda/efectos adversos , Humanos , Núcleo Accumbens , Calidad de Vida
7.
Epilepsia ; 63(1): 61-74, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34845719

RESUMEN

OBJECTIVE: Drug-resistant focal epilepsy is often caused by focal cortical dysplasias (FCDs). The distribution of these lesions across the cerebral cortex and the impact of lesion location on clinical presentation and surgical outcome are largely unknown. We created a neuroimaging cohort of patients with individually mapped FCDs to determine factors associated with lesion location and predictors of postsurgical outcome. METHODS: The MELD (Multi-centre Epilepsy Lesion Detection) project collated a retrospective cohort of 580 patients with epilepsy attributed to FCD from 20 epilepsy centers worldwide. Magnetic resonance imaging-based maps of individual FCDs with accompanying demographic, clinical, and surgical information were collected. We mapped the distribution of FCDs, examined for associations between clinical factors and lesion location, and developed a predictive model of postsurgical seizure freedom. RESULTS: FCDs were nonuniformly distributed, concentrating in the superior frontal sulcus, frontal pole, and temporal pole. Epilepsy onset was typically before the age of 10 years. Earlier epilepsy onset was associated with lesions in primary sensory areas, whereas later epilepsy onset was associated with lesions in association cortices. Lesions in temporal and occipital lobes tended to be larger than frontal lobe lesions. Seizure freedom rates varied with FCD location, from around 30% in visual, motor, and premotor areas to 75% in superior temporal and frontal gyri. The predictive model of postsurgical seizure freedom had a positive predictive value of 70% and negative predictive value of 61%. SIGNIFICANCE: FCD location is an important determinant of its size, the age at epilepsy onset, and the likelihood of seizure freedom postsurgery. Our atlas of lesion locations can be used to guide the radiological search for subtle lesions in individual patients. Our atlas of regional seizure freedom rates and associated predictive model can be used to estimate individual likelihoods of postsurgical seizure freedom. Data-driven atlases and predictive models are essential for evidence-based, precision medicine and risk counseling in epilepsy.


Asunto(s)
Epilepsia Refractaria , Epilepsia , Malformaciones del Desarrollo Cortical , Niño , Epilepsia Refractaria/complicaciones , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/cirugía , Epilepsia/diagnóstico por imagen , Epilepsia/etiología , Epilepsia/cirugía , Libertad , Humanos , Imagen por Resonancia Magnética , Malformaciones del Desarrollo Cortical/complicaciones , Malformaciones del Desarrollo Cortical/diagnóstico por imagen , Malformaciones del Desarrollo Cortical/cirugía , Estudios Retrospectivos , Convulsiones/diagnóstico por imagen , Convulsiones/etiología , Convulsiones/cirugía , Resultado del Tratamiento
8.
J Neuroimaging ; 31(3): 560-568, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33817887

RESUMEN

BACKGROUND AND PURPOSE: Magnetic resonance imaging (MRI) is essential in the diagnosis of pharmacoresistant epilepsy (PRE), because patients with lesions detected by MRI have a better prognosis after surgery. Focal cortical dysplasia (FCD) is one of the most frequent etiologies of PRE but can be difficult to identify by MRI. Voxel-based morphometric analysis programs, like the Morphometric Analysis Program (MAP), have been developed to help improve MRI detection. Our objective was to evaluate the clinical usefulness of MAP in patients with PRE and an apparently normal MRI. METHODS: We studied 70 patients with focal PRE and a nonlesional MRI. The 3DT1 sequence was processed with MAP, obtaining three z-score maps. Patients were classified as MAP+ if one or more z-score maps showed a suspicious area of brightness, and MAP- if the z-score maps did not show any suspicious areas. For MAP+ cases, a second-look MRI was performed with a dedicated inspection based on the MAP findings. The MAP results were correlated with the epileptogenic zone. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. RESULTS: Thirty-one percent of patients were classified as MAP+ and 69% were MAP-. Results showed a sensitivity of 0.57, specificity of 0.8, PPV of 0.91, and NPV of 0.35. In 19% of patients, an FCD was found in the second-look MRI after MAP. CONCLUSIONS: MAP was helpful in the detection of lesions in PRE patients with a nonlesional MRI, which could have important repercussions for the clinical management and postoperative prognosis of these patients.


Asunto(s)
Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/cirugía , Epilepsia/patología , Imagen por Resonancia Magnética/métodos , Malformaciones del Desarrollo Cortical de Grupo I/patología , Malformaciones del Desarrollo Cortical/diagnóstico por imagen , Adolescente , Adulto , Pesos y Medidas Corporales , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Mapeo Encefálico/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
9.
Comput Methods Programs Biomed ; 203: 106042, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33743489

RESUMEN

BACKGROUND AND OBJECTIVE: We present SYLVIUS, a software platform intended to facilitate and improve the complex workflow required to diagnose and surgically treat drug-resistant epilepsies. In complex epilepsies, additional invasive information from exploration with stereoencephalography (SEEG) with deep electrodes may be needed, for which the input from different diagnostic methods and clinicians from several specialties is required to ensure diagnostic efficacy and surgical safety. We aim to provide a software platform with optimal data flow among the different stages of epilepsy surgery to provide smooth and integrated decision making. METHODS: The SYLVIUS platform provides a clinical workflow designed to ensure seamless and safe patient data sharing across specialities. It integrates tools for stereo visualization, data registration, transfer of electrode plans referred to distinct datasets, automated postoperative contact segmentation, and novel DWI tractography analysis. Nineteen cases were retrospectively evaluated to track modifications from an initial plan to obtain a final surgical plan, using SYLVIUS. RESULTS: The software was used to modify trajectories in all 19 consulted cases, which were then imported into the robotic system for the surgical intervention. When available, SYLVIUS provided extra multimodal information, which resulted in a greater number of trajectory modifications. CONCLUSIONS: The architecture presented in this paper streamlines epilepsy surgery allowing clinicians to have a digital clinical tool that allows recording of the different stages of the procedure, in a common multimodal 2D/3D setting for participation of different clinicians in defining and validating surgical plans for SEEG cases.


Asunto(s)
Electroencefalografía , Epilepsia , Electrodos Implantados , Epilepsia/diagnóstico por imagen , Epilepsia/cirugía , Humanos , Estudios Retrospectivos , Programas Informáticos
10.
World Neurosurg ; 147: e47-e56, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33249218

RESUMEN

OBJECTIVE: Stereoelectroencephalography (SEEG) consists of the implantation of microelectrodes for the electrophysiological characterization of epileptogenic networks. To reduce a possible risk of intracranial bleeding by vessel rupture during the electrode implantation, the stereotactic trajectories must follow avascular corridors. The use of digital subtraction angiography (DSA) for vascular visualization during planning is controversial due to the additional risk related to this procedure. Here we evaluate the utility of this technique for planning when the neurosurgeon has it available together with gadolinium-enhanced T1-weighted magnetic resonance sequence (T1-Gd) and computed tomography angiography (CTA). METHODS: Twenty-two implantation plans for SEEG were initially done using T1-Gd imaging (251 trajectories). DSA was only used later during the revision process. In 6 patients CTA was available at this point as well. We quantified the position of the closest vessel to the trajectory in each of the imaging modalities. RESULTS: Two thirds of the trajectories that appeared vessel free in the T1-Gd or CTA presented vessels in their proximity, as shown by DSA. Those modifications only required small shifts of both the entry and target point, so the diagnostic aims were preserved. CONCLUSIONS: T1-Gd and CTA, despite being the most commonly used techniques for SEEG planning, frequently fail to reveal vessels that are dangerously close to the trajectories. Higher-resolution vascular imaging techniques, such as DSA, can provide the neurosurgeon with crucial information about vascular anatomy, resulting in safer plans.


Asunto(s)
Epilepsia Refractaria/fisiopatología , Electrocorticografía/métodos , Epilepsias Parciales/fisiopatología , Complicaciones Intraoperatorias/prevención & control , Microelectrodos , Implantación de Prótesis/métodos , Técnicas Estereotáxicas , Lesiones del Sistema Vascular/prevención & control , Adulto , Angiografía de Substracción Digital , Angiografía Cerebral , Angiografía por Tomografía Computarizada , Medios de Contraste , Epilepsia Refractaria/cirugía , Electrodos Implantados , Epilepsias Parciales/cirugía , Femenino , Humanos , Imagenología Tridimensional , Hemorragias Intracraneales/prevención & control , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Adulto Joven
11.
J Clin Med ; 9(6)2020 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-32580399

RESUMEN

BACKGROUND: The main objective of this study was to assess the safety and efficacy of deep brain stimulation (DBS) in patients with severe anorexia nervosa (AN). METHODS: Eight participants received active DBS to the subcallosal cingulate (SCC) or nucleus accumbens (NAcc) depending on comorbidities (affective or anxiety disorders, respectively) and type of AN. The primary outcome measure was body mass index (BMI). RESULTS: Overall, we found no significant difference (p = 0.84) between mean preoperative and postoperative (month 6) BMI. A BMI reference value (BMI-RV) was calculated. In patients that received preoperative inpatient care to raise the BMI, the BMI-RV was defined as the mean BMI value in the 12 months prior to surgery. In patients that did not require inpatient care, the BMI-RV was defined as the mean BMI in the 3-month period before surgery. This value was compared to the postoperative BMI (month 6), revealing a significant increase (p = 0.02). After 6 months of DBS, five participants showed an increase of ≥10% in the BMI-RV. Quality of life was improved (p = 0.03). Three cases presented cutaneous complications. CONCLUSION: DBS may be effective for some patients with severe AN. Cutaneous complications were observed. Longer term data are needed.

12.
J Tissue Eng Regen Med ; 12(4): e1991-e2000, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29266822

RESUMEN

Segregation of regenerating motor and sensory axons may be a good strategy to improve selective functionality of regenerative interfaces to provide closed-loop commands. Provided that extracellular matrix components and neurotrophic factors exert guidance effects on different neuronal populations, we assessed in vivo the potential of separating sensory and motor axons regenerating in a bicompartmental Y-type tube, with each branch prefilled with an adequate combination of extracellular matrix and neurotrophic factors. The severed rat sciatic nerve was repaired using a bicompartmental tube filled with a collagen matrix enriched with fibronectin (FN) and brain-derived neurotrophic factor (BDNF) encapsulated in poly-lactic co-glycolic acid microspheres (FN + MP.BDNF) in one compartment to preferentially attract motor axons and collagen enriched with laminin (LM) and nerve growth factor (NGF) and neurotrophin-3 (NT-3) in microspheres (LM + MP.NGF/NT-3) in the other compartment for promoting sensory axons regeneration. Control animals were implanted with the same Y-tube with a collagen matrix with microspheres (MP) containing PBS (Col + MP.PBS). By using retrotracer labelling, we found that LM + MP.NGF/NT-3 did not attract higher number of regenerated sensory axons compared with controls, and no differences were observed in sensory functional recovery. However, FN + MP.BDNF guided a higher number of regenerating motor axons compared with controls, improving also motor recovery. A small proportion of sensory axons with large soma size, likely proprioceptive neurons, was also attracted to the FN + MP.BDNF compartment. These results demonstrate that muscular axonal guidance can be modulated in vivo by the addition of fibronectin and BDNF.


Asunto(s)
Axones/metabolismo , Matriz Extracelular/química , Neuronas Motoras/metabolismo , Factores de Crecimiento Nervioso , Regeneración/efectos de los fármacos , Células Receptoras Sensoriales/metabolismo , Animales , Axones/patología , Femenino , Neuronas Motoras/patología , Factores de Crecimiento Nervioso/química , Factores de Crecimiento Nervioso/farmacología , Ratas , Ratas Sprague-Dawley , Células Receptoras Sensoriales/patología
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 1938-1941, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29060272

RESUMEN

A biomedical interface that combines into a single and compact device the recording of biopotentials and the electrical stimulation of neural fibres is presented. It is intended for enabling the control over a robotic hand and for restoring the sensory feedback in amputees by directly interfacing the peripheral nervous system (PNS) in closed-loop. A modular system consisting in one or more independent 16-channels bidirectional units was conceived. Each module is based on three 0.35µm bulk-CMOS integrated circuits (ICs): a recording unit, a High-Voltage (HV) stimulator and a HV booster. A tunable bandwidth (10Hz-8kHz) allows the recording IC to acquire both electroneurographyc (ENG) and electromiographyc (EMG) signals with a programmable gain up to 43.5dB. The signals are then converted into a digital domain by means of a ΣΔ converter. Due to the typical high impedance at the electrode-tissue interface, a programmable HV booster that increases the stimulation voltage up to 19V was designed. It is directly controlled by the stimulation module that generates current-based pulses with a programmable amplitude and pulse-width. The whole system was validated by means of in-vivo experiments in rats.


Asunto(s)
Sistema Nervioso Periférico , Amputados , Animales , Estimulación Eléctrica , Ratas
14.
J Neural Eng ; 14(6): 066016, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28695839

RESUMEN

OBJECTIVE: Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. APPROACH: We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. MAIN RESULTS: The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. SIGNIFICANCE: Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.


Asunto(s)
Electrodos Implantados , Diseño de Equipo/métodos , Rayos Láser , Ensayo de Materiales/métodos , Nervio Ciático/fisiología , Potenciales de Acción/fisiología , Animales , Ensayo de Materiales/instrumentación , Ratas , Ratas Sprague-Dawley , Factores de Tiempo
15.
Front Neurosci ; 10: 286, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27445660

RESUMEN

One of the most sought-after applications of neuroengineering is the communication between the arm and an artificial prosthetic device for the replacement of an amputated hand or the treatment of peripheral nerve injuries. For that, an electrode is placed around or inside the median nerve to serve as interface for recording and stimulation of nerve signals coming from the fascicles that innervate the muscles responsible for hand movements. Due to the lack of a standard procedure, the electrode implantation by the surgeon is strongly based on intuition, which may result in poor performance of the neuroprosthesis because of the suboptimal location of the neural interface. To provide morphological data that can aid the neuroprosthetic surgeon with this procedure, we investigated the fascicular topography of the human median nerve along the forearm and upper arm. We first performed a description of the fascicular content and branching patterns along the length of the arm. Next we built a 3D reconstruction of the median nerve so we could analyze the fascicle morphological features in relation to the arm level. Finally, we characterized the motor content of the median nerve fascicles in the upper arm. Collectively, these results indicate that fascicular organization occurs in a short segment distal to the epicondyles and remains unaltered until the muscular branches leave the main trunk. Based on our results, overall recommendations based on electrode type and implant location can be drawn to help and aid the neuroprosthetic procedure. Invasive interfaces would be more convenient for the upper arm and the most proximal third of the forearm. Epineural electrodes seem to be most suitable for the forearm segment after fascicles have been divided from the main trunk.

16.
IEEE Trans Biomed Eng ; 63(3): 581-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26276980

RESUMEN

This paper demonstrates flexible epineural strip electrodes (FLESE) for recording from small nerves. Small strip-shaped FLESE enables us to easily and closely stick on various sized nerves for less damage in a nerve and optimal recording quality. In addition, in order to enhance the neural interface, the gold electrode contacts were coated with carbon nanotubes, which reduced the impedance of the electrodes. We used the FLESEs to record electrically elicited nerve signals (compound neural action potentials) from the sciatic nerve in rats. Bipolar and differential bipolar configurations for the recording were investigated to optimize the recording configuration of the FLESEs. The successful results from differential bipolar recordings showed that the total length of FLESEs could be further reduced, maintaining the maximum recording ability, which would be beneficial for recording in very fine nerves. Our results demonstrate that new concept of FLESEs could play an important role in electroceuticals in near future.


Asunto(s)
Electrofisiología/instrumentación , Nanotubos de Carbono/química , Procesamiento de Señales Asistido por Computador/instrumentación , Animales , Estimulación Eléctrica/instrumentación , Electrodos , Diseño de Equipo , Femenino , Ratas , Ratas Sprague-Dawley , Nervio Ciático/fisiología
17.
PLoS One ; 9(11): e114033, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25422940

RESUMEN

Synchronization of neurotransmitter release with the presynaptic action potential is essential for maintaining fidelity of information transfer in the central nervous system. However, synchronous release is frequently accompanied by an asynchronous release component that builds up during repetitive stimulation, and can even play a dominant role in some synapses. Here, we show that substitution of SNAP-23 for SNAP-25 in mouse autaptic glutamatergic hippocampal neurons results in asynchronous release and a higher frequency of spontaneous release events (mEPSCs). Use of neurons from double-knock-out (SNAP-25, synaptotagmin-7) mice in combination with viral transduction showed that SNAP-23-driven release is triggered by endogenous synaptotagmin-7. In the absence of synaptotagmin-7 release became even more asynchronous, and the spontaneous release rate increased even more, indicating that synaptotagmin-7 acts to synchronize release and suppress spontaneous release. However, compared to synaptotagmin-1, synaptotagmin-7 is a both leaky and asynchronous calcium sensor. In the presence of SNAP-25, consequences of the elimination of synaptotagmin-7 were small or absent, indicating that the protein pairs SNAP-25/synaptotagmin-1 and SNAP-23/synaptotagmin-7 might act as mutually exclusive calcium sensors. Expression of fusion proteins between pHluorin (pH-sensitive GFP) and synaptotagmin-1 or -7 showed that vesicles that fuse using the SNAP-23/synaptotagmin-7 combination contained synaptotagmin-1, while synaptotagmin-7 barely displayed activity-dependent trafficking between vesicle and plasma membrane, implying that it acts as a plasma membrane calcium sensor. Overall, these findings support the idea of alternative syt∶SNARE combinations driving release with different kinetics and fidelity.


Asunto(s)
Neuronas/metabolismo , Proteínas Qb-SNARE/metabolismo , Proteínas Qc-SNARE/metabolismo , Transmisión Sináptica/fisiología , Sinaptotagminas/fisiología , Animales , Línea Celular , Ratones , Ratones Noqueados , Proteínas Qb-SNARE/genética , Proteínas Qc-SNARE/genética
18.
Artículo en Inglés | MEDLINE | ID: mdl-25571423

RESUMEN

Working memory (WM) refers to the retention of information over a short period of time. Accumulated evidence showed that training WM would lead to beneficial effects in untrained tasks, which could be attributed to the strengthening of the functional connections between brain regions through repeated training task. In this proof of concept investigation, we applied a graph theoretical approach to analyze the early changes of functional connectivity from two subjects undergoing a spatial n-back WM training task for three continuous days. A significant decreased clustering coefficient and normalized shortest path length was revealed, suggesting a reduced local efficiency with an increased global efficiency after WM training. Our findings thereby provide insightful implications for understanding the mechanisms of brain dynamics in cognitive training.


Asunto(s)
Aprendizaje , Memoria a Corto Plazo/fisiología , Red Nerviosa/fisiología , Adulto , Conducta , Humanos , Persona de Mediana Edad , Análisis y Desempeño de Tareas
19.
Artículo en Inglés | MEDLINE | ID: mdl-25570451

RESUMEN

Neuroprosthetic devices that interface with the nervous system to restore functional motor activity offer a viable alternative to nerve regeneration, especially in proximal nerve injuries like brachial plexus injuries where muscle atrophy may set in before nerve re-innervation occurs. Prior studies have used control signals from muscle or cortical activity. However, nerve signals are preferred in many cases since they permit more natural and precise control when compared to muscle activity, and can be accessed with much lower risk than cortical activity. Identification of nerve signals that control the appropriate muscles is essential for the development of such a `bionic link'. Here we examine the correlation between muscle and nerve signals responsible for hand grasping in the M. fascicularis. Simultaneous recordings were performed using a 4-channel thin-film longitudinal intra-fascicular electrode (tf-LIFE) and 9 bipolar endomysial muscle electrodes while the animal performed grasping movements. We were able to identify a high degree of correlation (r > 0.6) between nerve signals from the median nerve and movement-dependent muscle activity from the flexor muscles of the forearm, with a delay that corresponded to 25 m/s nerve conduction velocity. The phase of the flexion could be identified using a wavelet approximation of the ENG. This result confirms this approach for a future neuroprosthetic device for the treatment of peripheral nerve injuries.


Asunto(s)
Plexo Braquial/lesiones , Fuerza de la Mano/fisiología , Nervio Mediano/fisiología , Movimiento/fisiología , Músculo Esquelético/fisiología , Rango del Movimiento Articular , Animales , Estimulación Eléctrica , Electrodos , Electrodos Implantados , Macaca fascicularis , Tejido Nervioso , Conducción Nerviosa , Neuronas/fisiología , Nervios Periféricos/patología
20.
Biomed Eng Online ; 12: 38, 2013 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-23631798

RESUMEN

Optical imaging techniques reflect different biochemical processes in the brain, which is closely related with neural activity. Scientists and clinicians employ a variety of optical imaging technologies to visualize and study the relationship between neurons, glial cells and blood vessels. In this paper, we present an overview of the current optical approaches used for the in vivo imaging of neurovascular coupling events in small animal models. These techniques include 2-photon microscopy, laser speckle contrast imaging (LSCI), voltage-sensitive dye imaging (VSDi), functional photoacoustic microscopy (fPAM), functional near-infrared spectroscopy imaging (fNIRS) and multimodal imaging techniques. The basic principles of each technique are described in detail, followed by examples of current applications from cutting-edge studies of cerebral neurovascular coupling functions and metabolic. Moreover, we provide a glimpse of the possible ways in which these techniques might be translated to human studies for clinical investigations of pathophysiology and disease. In vivo optical imaging techniques continue to expand and evolve, allowing us to discover fundamental basis of neurovascular coupling roles in cerebral physiology and pathophysiology.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/irrigación sanguínea , Encéfalo/fisiología , Imagen Óptica/métodos , Animales , Humanos , Imagen Multimodal , Investigación Biomédica Traslacional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...