Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Scand J Work Environ Health ; 47(2): 95-107, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33258478

RESUMEN

Objective A consensual definition of occupational burnout is currently lacking. We aimed to harmonize the definition of occupational burnout as a health outcome in medical research and reach a consensus on this definition within the Network on the Coordination and Harmonisation of European Occupational Cohorts (OMEGA-NET). Methods First, we performed a systematic review in MEDLINE, PsycINFO and Embase (January 1990 to August 2018) and a semantic analysis of the available definitions. We used the definitions of burnout and burnout-related concepts from the Systematized Nomenclature of Medicine Clinical Terms (SNOMED-CT) to formulate a consistent harmonized definition of the concept. Second, we sought to obtain the Delphi consensus on the proposed definition. Results We identified 88 unique definitions of burnout and assigned each of them to 1 of the 11 original definitions. The semantic analysis yielded a first proposal, further reformulated according to SNOMED-CT and the panelists` comments as follows: "In a worker, occupational burnout or occupational physical AND emotional exhaustion state is an exhaustion due to prolonged exposure to work-related problems". A panel of 50 experts (researchers and healthcare professionals with an interest for occupational burnout) reached consensus on this proposal at the second round of the Delphi, with 82% of experts agreeing on it. Conclusion This study resulted in a harmonized definition of occupational burnout approved by experts from 29 countries within OMEGA-NET. Future research should address the reproducibility of the Delphi consensus in a larger panel of experts, representing more countries, and examine the practicability of the definition.


Asunto(s)
Agotamiento Profesional , Consenso , Técnica Delphi , Humanos , Reproducibilidad de los Resultados , Semántica , Encuestas y Cuestionarios
2.
J Orthop Traumatol ; 12(2): 81-6, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21544549

RESUMEN

BACKGROUND: Isolated reports indicate the efficacy of infrared thermography for monitoring wound healing and septic complications, but no long-term analysis has ever been performed on this, and there are no data on the telethermographic patterns of surgical site healing after uncomplicated total hip prosthesis and after knee prosthesis. MATERIALS AND METHODS: In this prospective, observational, nonrandomized cohort study, two groups with forty consecutive patients each, who were operated on respectively for total hip and for total knee replacements, underwent telethermographic examination of the operated and contralateral joints prior to and at fixed intervals for up to 1 year after uncomplicated surgery. A digital, portable telethermocamera and dedicated software were used for data acquisition and processing. RESULTS: No thermographic difference was observed preoperatively between the affected side and the contralateral side in both groups. After the intervention, a steep increase in the temperature of the operated joint was recorded after total hip replacement and after knee replacement, with a peak mean differential temperature measured three days postoperatively between the operated and unoperated joint of 3.1 ± 0.8°C after total hip replacement, and 3.4 ± 0.7°C after total knee replacement. Thereafter, the mean differential temperature declined slowly to 0.7 ± 1.1°C and to 0.5 ± 1.3°C at 60 days, and to 0.0 ± 1.0°C and -0.1 ± 1.1°C 90 days post-operatively, respectively. No further changes were observed for up to 1 year after surgery. Results were similar when comparing the average telethermographic values of an elliptical area where the main axis corresponded to the surgical wound. CONCLUSIONS: The surgical sites after uncomplicated total hip or total knee replacement show similar telethermographic patterns for up to 1 year from surgery, and can easily be monitored using a portable, digital, telethermocamera.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Complicaciones Posoperatorias/diagnóstico , Termografía/métodos , Cicatrización de Heridas/fisiología , Anciano , Temperatura Corporal/fisiología , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios , Complicaciones Posoperatorias/fisiopatología , Estudios Prospectivos , Termografía/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA