Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Mov Disord ; 39(2): 328-338, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38151859

RESUMEN

BACKGROUND: Real-world monitoring using wearable sensors has enormous potential for assessing disease severity and symptoms among persons with Parkinson's disease (PD). Many distinct features can be extracted, reflecting multiple mobility domains. However, it is unclear which digital measures are related to PD severity and are sensitive to disease progression. OBJECTIVES: The aim was to identify real-world mobility measures that reflect PD severity and show discriminant ability and sensitivity to disease progression, compared to the Movement Disorder Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) scale. METHODS: Multicenter real-world continuous (24/7) digital mobility data from 587 persons with PD and 68 matched healthy controls were collected using an accelerometer adhered to the lower back. Machine learning feature selection and regression algorithms evaluated associations of the digital measures using the MDS-UPDRS (I-III). Binary logistic regression assessed discriminatory value using controls, and longitudinal observational data from a subgroup (n = 33) evaluated sensitivity to change over time. RESULTS: Digital measures were only moderately correlated with the MDS-UPDRS (part II-r = 0.60 and parts I and III-r = 0.50). Most associated measures reflected activity quantity and distribution patterns. A model with 14 digital measures accurately distinguished recently diagnosed persons with PD from healthy controls (81.1%, area under the curve: 0.87); digital measures showed larger effect sizes (Cohen's d: [0.19-0.66]), for change over time than any of the MDS-UPDRS parts (Cohen's d: [0.04-0.12]). CONCLUSIONS: Real-world mobility measures are moderately associated with clinical assessments, suggesting that they capture different aspects of motor capacity and function. Digital mobility measures are sensitive to early-stage disease and to disease progression, to a larger degree than conventional clinical assessments, demonstrating their utility, primarily for clinical trials but ultimately also for clinical care. © 2023 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/complicaciones , Pruebas de Estado Mental y Demencia , Modelos Logísticos , Índice de Severidad de la Enfermedad , Progresión de la Enfermedad
2.
Front Bioeng Biotechnol ; 11: 1143248, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37214281

RESUMEN

Introduction: Accurately assessing people's gait, especially in real-world conditions and in case of impaired mobility, is still a challenge due to intrinsic and extrinsic factors resulting in gait complexity. To improve the estimation of gait-related digital mobility outcomes (DMOs) in real-world scenarios, this study presents a wearable multi-sensor system (INDIP), integrating complementary sensing approaches (two plantar pressure insoles, three inertial units and two distance sensors). Methods: The INDIP technical validity was assessed against stereophotogrammetry during a laboratory experimental protocol comprising structured tests (including continuous curvilinear and rectilinear walking and steps) and a simulation of daily-life activities (including intermittent gait and short walking bouts). To evaluate its performance on various gait patterns, data were collected on 128 participants from seven cohorts: healthy young and older adults, patients with Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, congestive heart failure, and proximal femur fracture. Moreover, INDIP usability was evaluated by recording 2.5-h of real-world unsupervised activity. Results and discussion: Excellent absolute agreement (ICC >0.95) and very limited mean absolute errors were observed for all cohorts and digital mobility outcomes (cadence ≤0.61 steps/min, stride length ≤0.02 m, walking speed ≤0.02 m/s) in the structured tests. Larger, but limited, errors were observed during the daily-life simulation (cadence 2.72-4.87 steps/min, stride length 0.04-0.06 m, walking speed 0.03-0.05 m/s). Neither major technical nor usability issues were declared during the 2.5-h acquisitions. Therefore, the INDIP system can be considered a valid and feasible solution to collect reference data for analyzing gait in real-world conditions.

3.
Sensors (Basel) ; 23(8)2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37112261

RESUMEN

The analysis of the stability of human gait may be effectively performed when estimates of the base of support are available. The base of support area is defined by the relative position of the feet when they are in contact with the ground and it is closely related to additional parameters such as step length and stride width. These parameters may be determined in the laboratory using either a stereophotogrammetric system or an instrumented mat. Unfortunately, their estimation in the real world is still an unaccomplished goal. This study aims at proposing a novel, compact wearable system, including a magneto-inertial measurement unit and two time-of-flight proximity sensors, suitable for the estimation of the base of support parameters. The wearable system was tested and validated on thirteen healthy adults walking at three self-selected speeds (slow, comfortable, and fast). Results were compared with the concurrent stereophotogrammetric data, used as the gold standard. The root mean square errors for the step length, stride width and base of support area varied from slow to high speed between 10-46 mm, 14-18 mm, and 39-52 cm2, respectively. The mean overlap of the base of support area as obtained with the wearable system and with the stereophotogrammetric system ranged between 70% and 89%. Thus, this study suggested that the proposed wearable solution is a valid tool for the estimation of the base of support parameters out of the laboratory.


Asunto(s)
Caminata , Dispositivos Electrónicos Vestibles , Adulto , Humanos , Marcha , Pie , Fotogrametría
4.
Sensors (Basel) ; 22(19)2022 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-36236525

RESUMEN

Cerebral palsy, the most common childhood neuromotor disorder, is often diagnosed through visual assessment of general movements (GM) in infancy. This skill requires extensive training and is thus difficult to implement on a large scale. Automated analysis of GM performed using low-cost instrumentation in the home may be used to estimate quantitative metrics predictive of movement disorders. This study explored if infants' GM may be successfully evaluated in a familiar environment by processing the 3D trajectories of points of interest (PoI) obtained from recordings of a single commercial RGB-D sensor. The RGB videos were processed using an open-source markerless motion tracking method which allowed the estimation of the 2D trajectories of the selected PoI and a purposely developed method which allowed the reconstruction of their 3D trajectories making use of the data recorded with the depth sensor. Eight infants' GM were recorded in the home at 3, 4, and 5 months of age. Eight GM metrics proposed in the literature in addition to a novel metric were estimated from the PoI trajectories at each timepoint. A pediatric neurologist and physiatrist provided an overall clinical evaluation from infants' video. Subsequently, a comparison between metrics and clinical evaluation was performed. The results demonstrated that GM metrics may be meaningfully estimated and potentially used for early identification of movement disorders.


Asunto(s)
Parálisis Cerebral , Trastornos del Movimiento , Parálisis Cerebral/diagnóstico , Niño , Humanos , Lactante , Movimiento (Física) , Movimiento , Trastornos del Movimiento/diagnóstico , Redes Neurales de la Computación
5.
Sensors (Basel) ; 21(18)2021 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-34577514

RESUMEN

The orientation of a magneto-inertial measurement unit can be estimated using a sensor fusion algorithm (SFA). However, orientation accuracy is greatly affected by the choice of the SFA parameter values which represents one of the most critical steps. A commonly adopted approach is to fine-tune parameter values to minimize the difference between estimated and true orientation. However, this can only be implemented within the laboratory setting by requiring the use of a concurrent gold-standard technology. To overcome this limitation, a Rigid-Constraint Method (RCM) was proposed to estimate suboptimal parameter values without relying on any orientation reference. The RCM method effectiveness was successfully tested on a single-parameter SFA, with an average error increase with respect to the optimal of 1.5 deg. In this work, the applicability of the RCM was evaluated on 10 popular SFAs with multiple parameters under different experimental scenarios. The average residual between the optimal and suboptimal errors amounted to 0.6 deg with a maximum of 3.7 deg. These encouraging results suggest the possibility to properly tune a generic SFA on different scenarios without using any reference. The synchronized dataset also including the optical data and the SFA codes are available online.


Asunto(s)
Algoritmos , Heurística , Fenómenos Biomecánicos , Fenómenos Magnéticos , Magnetismo
6.
Sensors (Basel) ; 21(18)2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34577387

RESUMEN

The objectives of this study were to assess the accuracy and precision of a system combining an IMU-instrumented sock and a validated algorithm for the estimation of the spatio-temporal parameters of gait. A total of 25 healthy participants (HP) and 21 patients with foot impairments secondary to psoriatic arthritis (PsA) performed treadmill walking at three different speeds and overground walking at a comfortable speed. HP performed the assessment over two sessions. The proposed system's estimations of cadence (CAD), gait cycle duration (GCD), gait speed (GS), and stride length (SL) obtained for treadmill walking were validated versus those estimated with a motion capture system. The system was also compared with a well-established multi-IMU-based system for treadmill and overground walking. The results showed a good agreement between the motion capture system and the IMU-instrumented sock in estimating the spatio-temporal parameters during the treadmill walking at normal and fast speeds for both HP and PsA participants. The accuracy of GS and SL obtained from the IMU-instrumented sock was better compared to the established multi-IMU-based system in both groups. The precision (inter-session reliability) of the gait parameter estimations obtained from the IMU-instrumented sock was good to excellent for overground walking and treadmill walking at fast speeds, but moderate-to-good for slow and normal treadmill walking. The proposed IMU-instrumented sock offers a novel form factor addressing the wearability issues of IMUs and could potentially be used to measure spatio-temporal parameters under clinical conditions and free-living conditions.


Asunto(s)
Artritis Psoriásica , Caminata , Artritis Psoriásica/diagnóstico , Fenómenos Biomecánicos , Prueba de Esfuerzo , Marcha , Voluntarios Sanos , Humanos , Reproducibilidad de los Resultados
7.
Mov Disord ; 36(9): 2144-2155, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33955603

RESUMEN

BACKGROUND: It is not clear how specific gait measures reflect disease severity across the disease spectrum in Parkinson's disease (PD). OBJECTIVE: To identify the gait and mobility measures that are most sensitive and reflective of PD motor stages and determine the optimal sensor location in each disease stage. METHODS: Cross-sectional wearable-sensor records were collected in 332 patients with PD (Hoehn and Yahr scale I-III) and 100 age-matched healthy controls. Sensors were adhered to the participant's lower back, bilateral ankles, and wrists. Study participants walked in a ~15-meter corridor for 1 minute under two walking conditions: (1) preferred, usual walking speed and (2) walking while engaging in a cognitive task (dual-task). A subgroup (n = 303, 67% PD) also performed the Timed Up and Go test. Multiple machine-learning feature selection and classification algorithms were applied to discriminate between controls and PD and between the different PD severity stages. RESULTS: High discriminatory values were found between motor disease stages with mean sensitivity in the range 72%-83%, specificity 69%-80%, and area under the curve (AUC) 0.76-0.90. Measures from upper-limb sensors best discriminated controls from early PD, turning measures obtained from the trunk sensor were prominent in mid-stage PD, and stride timing and regularity were discriminative in more advanced stages. CONCLUSIONS: Applying machine-learning to multiple, wearable-derived features reveals that different measures of gait and mobility are associated with and discriminate distinct stages of PD. These disparate feature sets can augment the objective monitoring of disease progression and may be useful for cohort selection and power analyses in clinical trials of PD. © 2021 International Parkinson and Movement Disorder Society.


Asunto(s)
Enfermedad de Parkinson , Estudios Transversales , Marcha , Humanos , Aprendizaje Automático , Enfermedad de Parkinson/diagnóstico , Equilibrio Postural , Estudios de Tiempo y Movimiento , Caminata
8.
Sensors (Basel) ; 21(7)2021 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-33916432

RESUMEN

The orientation of a magneto and inertial measurement unit (MIMU) is estimated by means of sensor fusion algorithms (SFAs) thus enabling human motion tracking. However, despite several SFAs implementations proposed over the last decades, there is still a lack of consensus about the best performing SFAs and their accuracy. As suggested by recent literature, the filter parameters play a central role in determining the orientation errors. The aim of this work is to analyze the accuracy of ten SFAs while running under the best possible conditions (i.e., their parameter values are set using the orientation reference) in nine experimental scenarios including three rotation rates and three commercial products. The main finding is that parameter values must be specific for each SFA according to the experimental scenario to avoid errors comparable to those obtained when the default parameter values are used. Overall, when optimally tuned, no statistically significant differences are observed among the different SFAs in all tested experimental scenarios and the absolute errors are included between 3.8 deg and 7.1 deg. Increasing the rotation rate generally leads to a significant performance worsening. Errors are also influenced by the MIMU commercial model. SFA MATLAB implementations have been made available online.

9.
Front Aging Neurosci ; 13: 753381, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35069171

RESUMEN

Treadmill training with virtual reality (TT + VR) has been shown to improve gait performance and to reduce fall risk in Parkinson's disease (PD). However, there is no consensus on the optimal training duration. This study is a sub-study of the V-TIME randomized clinical trial (NCT01732653). In this study, we explored the effect of the duration of training based on the motor-cognitive interaction on motor and cognitive performance and on fall risk in subjects with PD. Patients in Hoehn and Yahr stages II-III, aged between 40 and 70 years, were included. In total, 96 patients with PD were assigned to 6 or 12 weeks of TT + VR intervention, and 77 patients completed the full protocol. Outcome measures for gait and cognitive performance were assessed at baseline, immediately after training, and at 1- and 6-month follow-up. The incident rate of falls in the 6-month pre-intervention was compared with that in the 6-month post-intervention. Dual-task gait performance (gait speed, gait speed variability and stride length under cognitive dual task and obstacle negotiation, and the leading foot clearance in obstacle negotiation) improved similarly in both groups with gains sustained at 6-month follow-up. A higher decrease in fall rate and fear of falling were observed in participants assigned to the 12-week intervention than the 6-week intervention. Improvements in cognitive functions (i.e., executive functions, visuospatial ability, and attention) were seen only in participants enrolled in 12-week training up to 1-month follow-up but vanished at the 6-month evaluation. Our results suggest that a longer TT + VR training leads to greater improvements in cognitive functions especially those directly addressed by the virtual environment.

10.
Front Neurol ; 11: 573616, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33123079

RESUMEN

Historical, educational, and technical barriers have been reported to limit the use of surface electromyography (sEMG) in clinical neurorehabilitation settings. In an attempt to identify, review, rank, and interpret potential factors that may play a role in this scenario, we gathered information on (1) current use of sEMG and its clinical potential; (2) professional figures primarily dealing with sEMG; (3) educational aspects, and (4) possible barriers and reasons for its apparently limited use in neurorehabilitation. To this aim, an online 30-question survey was sent to 52 experts on sEMG from diverse standpoints, backgrounds, and countries. Participants were asked to respond to each question on a 5-point Likert scale or by ranking items. A cut-off of 75% agreement was chosen as the consensus threshold. Thirty-five invitees (67%) completed the electronic survey. Consensus was reached for 77% of the proposed questions encompassing current trends in sEMG use in neurorehabilitation, educational, technical, and methodological features as well as its translational utility for clinicians and patients. Data evidenced the clinical utility of sEMG for patient assessment, to define the intervention plan, and to complement/optimize other methods used to quantify muscle and physical function. The aggregate opinion of the interviewed experts confirmed that sEMG is more frequently employed in technical/methodological than clinical research. Moreover, the slow dissemination of research findings and the lack of education on sEMG seem to prevent prompt transfer into practice. The findings of the present survey may contribute to the ongoing debate on the appropriateness and value of sEMG for neurorehabilitation professionals and its potential translation into clinical settings.

11.
Artículo en Inglés | MEDLINE | ID: mdl-32695751

RESUMEN

Many studies have investigated the bilateral upper limb coordination during movements under different motor and visual conditions. Bilateral training has also been proposed as an effective rehabilitative protocol for patients with stroke. However, the factors influencing in-phase vs. anti-phase coupling have not yet been fully explored. In this study, we used a motion capture device based on two infrared distance sensors to assess whether the up and down oscillation of the less functional hand (the non-dominant one in healthy younger and older subjects and the paretic one in patients with stroke) could be influenced by in-phase or anti-phase coupling of the more functional hand and by visual feedback. Similar patterns were found between single hand movements and in-phase coupled movements, whereas anti-phase coupled movements were less ample, less sinusoidal, but more frequent. These features were particularly evident for patients with stroke who showed a reduced waveform similarity of bilateral movements in all conditions but especially for anti-phase movements under visual control. These results indicate that visuomotor integration in patients with stroke could be less effective than in healthy subjects, probably because of the attentional overload required when moving the two limbs in an alternating fashion.

12.
Neurorehabil Neural Repair ; 34(5): 440-449, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32202203

RESUMEN

Background. People with Parkinson's disease and freezing of gait (FOG+) have more falls, postural instability and cognitive impairment compared with FOG-. Objective. To conduct a secondary analysis of the V-TIME study, a randomized, controlled investigation showing a greater reduction of falls after virtual reality treadmill training (TT + VR) compared with usual treadmill walking (TT) in a mixed population of fallers. We addressed whether these treadmill interventions led to similar gains in FOG+ as in FOG-. Methods. A total of 77 FOG+ and 44 FOG- were assigned randomly to TT + VR or TT. Participants were assessed pre- and posttraining and at 6 months' follow-up. Main outcome was postural stability assessed by the Mini Balance Evaluation System Test (Mini-BEST) test. Falls were documented using diaries. Other outcomes included the New Freezing of Gait Questionnaire (NFOG-Q) and the Trail Making Test (TMT-B). Results. Mini-BEST scores and the TMT-B improved in both groups after training (P = .001), irrespective of study arm and FOG subgroup. However, gains were not retained at 6 months. Both FOG+ and FOG- had a greater reduction of falls after TT + VR compared with TT (P = .008). NFOG-Q scores did not change after both training modes in the FOG+ group. Conclusions. Treadmill walking (with or without VR) improved postural instability in both FOG+ and FOG-, while controlling for disease severity differences. As found previously, TT + VR reduced falls more than TT alone, even among those with FOG. Interestingly, FOG itself was not helped by training, suggesting that although postural instability, falls and FOG are related, they may be controlled by different mechanisms.


Asunto(s)
Accidentes por Caídas/prevención & control , Terapia por Ejercicio , Trastornos Neurológicos de la Marcha/rehabilitación , Rehabilitación Neurológica , Evaluación de Resultado en la Atención de Salud , Enfermedad de Parkinson/rehabilitación , Equilibrio Postural , Realidad Virtual , Anciano , Anciano de 80 o más Años , Terapia por Ejercicio/instrumentación , Terapia por Ejercicio/métodos , Femenino , Trastornos Neurológicos de la Marcha/etiología , Humanos , Masculino , Persona de Mediana Edad , Rehabilitación Neurológica/instrumentación , Rehabilitación Neurológica/métodos , Enfermedad de Parkinson/complicaciones , Equilibrio Postural/fisiología
13.
Vet Sci ; 7(1)2020 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-32092869

RESUMEN

Objective-To design and test a motion analysis protocol for the gait analysis of adult German Shepherd (GS) dogs with a focus in the analyses of their back movements. Animals-Eight clinically healthy adult large-sized GS dogs (age, 4 ± 1.3 years; weight, 38.8 ± 4.2 kg). Procedures-A six-camera stereo-photogrammetric system and two force platforms were used for data acquisition. Experimental acquisition sessions consisted of static and gait trials. During gait trials, each dog walked along a 6 m long walkway at self-selected speed and a total of six gait cycles were recorded. Results-Grand mean and standard deviation of ground reaction forces of fore and hind limbs are reported. Spatial-temporal parameters averaged over gait cycles and subjects, their mean, standard deviation and coefficient of variance are analyzed. Joint kinematics for the hip, stifle and tarsal joints and their average range of motion (ROM) values, and their 95% Confidence Interval (CI) values of kinematics curves are reported. Conclusions and Clinical Relevance-This study provides normative data of healthy GS dogs to form a preliminary basis in the analysis of the spatial-temporal parameters, kinematics and kinetics during quadrupedal stance posture and gait. Also, a new back movement protocol enabling a multi-segment back model is provided. Results show that the proposed gait analysis protocol may become a useful and objective tool for the evaluation of canine treatment with special focus on the back movement.

14.
J Gerontol A Biol Sci Med Sci ; 75(6): 1198-1205, 2020 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-31942969

RESUMEN

BACKGROUND: Physical activity is linked to many positive health outcomes, stimulating the development of exercise programs. However, many falls occur while walking and so promoting activity might paradoxically increase fall rates, causing injuries, and worse quality of life. The relationship between activity exposure and fall rates remains unclear. We investigated the relationship between walking activity (exposure to risk) and fall rates before and after an exercise program (V-TIME). METHODS: One hundred and nine older fallers, 38 fallers with mild cognitive impairment (MCI), and 128 fallers with Parkinson's disease (PD) were randomly assigned to one of two active interventions: treadmill training only or treadmill training combined with a virtual reality component. Participants were tested before and after the interventions. Free-living walking activity was characterized by volume, pattern, and variability of ambulatory bouts using an accelerometer positioned on the lower back for 1 week. To evaluate that relationship between fall risk and activity, a normalized index was determined expressing fall rates relative to activity exposure (FRA index), with higher scores indicating a higher risk of falls per steps taken. RESULTS: At baseline, the FRA index was higher for fallers with PD compared to those with MCI and older fallers. Walking activity did not change after the intervention for the groups but the FRA index decreased significantly for all groups (p ≤ .035). CONCLUSIONS: This work showed that V-TIME interventions reduced falls risk without concurrent change in walking activity. We recommend using the FRA index in future fall prevention studies to better understand the nature of intervention programs.


Asunto(s)
Accidentes por Caídas/prevención & control , Ejercicio Físico , Caminata/estadística & datos numéricos , Accidentes por Caídas/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Disfunción Cognitiva/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Enfermedad de Parkinson/complicaciones , Factores de Riesgo , Caminata/lesiones
15.
Clin Biomech (Bristol, Avon) ; 67: 102-106, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31100700

RESUMEN

BACKGROUND: Maximal strength is a predictor of functional capacity for people with multiple sclerosis (PwMS), who frequently exhibit unilateral weakness of the ankle dorsiflexors. Aims of this study were to investigate the relationships between dorsiflexors' weakness and gait speed, the effects of high-intensity training of the affected dorsiflexors on gait performance and to identify isokinetic predictors of changes in gait speed in PwMs. METHODS: Twenty patients aged 45 (10.3) years, illness duration 14.9 (8.5) years, median EDSS 3, underwent isokinetic dorsiflexors' strength testing at 10°/s and 45°/s angular velocities and gait analysis before and after a 6-week training of dorsiflexors. Pre-to-post differences in strength and gait parameters were analyzed by paired t-test; association between gait speed and isokinetic parameters was tested through correlation and regression analyses. FINDINGS: Dorsiflexors' strength (peak moment at 10°/s: +14.9%, p = 0.02; at 45°/s: +21.7%, p = 0.03) and gait parameters (speed: +9.6%; p = 0.004; stride time: -5.7%; p = 0.01; cadence: +6.2%; p = 0.001; ankle power: +27.5%, p = 0.003) increased significantly. Of the thirteen isokinetic descriptors of strength, only peak moment, maximal and total work significantly correlated with gait speed increase. Regression analyses revealed high beta coefficients only for maximal work (10°/s: B = -6.528; beta = -1.825; p = 0.008; 45°/s: B = -1.466; beta = -1.364; p = 0.03). INTERPRETATION: In PwMS, high-intensity training of weakened ankle dorsiflexors induced significant improvements in maximal strength and gait speed. The finding of maximal work as a significant predictor of training-induced changes in gait speed suggests that PwMS with reduced muscle work may benefit from strength training approaches aimed at increasing gait speed. Registration number: ClinicalTrials.gov Identifier: NCT02010398.


Asunto(s)
Articulación del Tobillo/fisiopatología , Tobillo/fisiopatología , Esclerosis Múltiple Recurrente-Remitente/fisiopatología , Entrenamiento de Fuerza , Velocidad al Caminar , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto
16.
Parkinsonism Relat Disord ; 62: 85-90, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30718220

RESUMEN

INTRODUCTION: Recent work suggests that wearables can augment conventional measures of Parkinson's disease (PD). We evaluated the relationship between conventional measures of disease and motor severity (e.g., MDS-UPDRS part III), laboratory-based measures of gait and balance, and daily-living physical activity measures in patients with PD. METHODS: Data from 125 patients (age: 71.7 ±â€¯6.5 years, Hoehn and Yahr: 1-3, 60.5% men) were analyzed. The MDS-UPDRS-part III was used as the gold standard of motor symptom severity. Gait and balance were quantified in the laboratory. Daily-living gait and physical activity metrics were extracted from an accelerometer worn on the lower back for 7 days. RESULTS: In multivariate analyses, daily-living physical activity and gait metrics, laboratory-based balance, demographics and subject characteristics together explained 46% of the variance in MDS-UPDRS-part III scores. Daily-living measures accounted for 62% of the explained variance, laboratory measures 30%, and demographics and subject characteristics 7% of the explained variance. Conversely, demographics and subject characteristics, laboratory-based measures of gait symmetry, and motor symptom severity together explained less than 30% of the variance in total daily-living physical activity. MDS-UPDRS-part III scores accounted for 13% of the explained variance, i.e., <4% of all the variance in total daily-living activity. CONCLUSIONS: Our findings suggest that conventional measures of motor symptom severity do not strongly reflect daily-living activity and that daily-living measures apparently provide important information that is not captured in a conventional one-time, laboratory assessment of gait, balance or the MDS-UPDRS. To provide a more complete evaluation, wearable devices should be considered.


Asunto(s)
Ejercicio Físico/fisiología , Marcha/fisiología , Laboratorios , Enfermedad de Parkinson/fisiopatología , Accidentes por Caídas , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/diagnóstico , Índice de Severidad de la Enfermedad
17.
J Biomech ; 84: 274-277, 2019 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-30630626

RESUMEN

Accurate step detection is crucial for the estimation of gait spatio-temporal parameters. Although several step detection methods based on the use of inertial measurement units (IMUs) have been successfully proposed, they may not perform adequately when the foot is dragged while walking, when walking aids are used, or when walking at low speed. The aim of this study was to test an original step-detection method, the inter-foot distance step counter (IFOD), based on the direct measurement of the distance between feet. Gait data were recorded using a wearable prototype system (SWING2DS), which integrates an IMU and two time-of-flight distance sensors (DSs). The system was attached to the medial side of the right foot with one DS positioned close to the forefoot (FOREDS) and the other close to the rearfoot (REARDS). Sixteen healthy adults were asked to walk over ground for two minutes along a loop, including both rectilinear and curvilinear portions, during two experimental sessions. The accuracy of the IFOD step counter was assessed using a stereo-photogrammetric system as gold standard. The best performance was obtained for REARDS with an accuracy higher than 99.8% for the instrumented foot step and 88.8% for the non-instrumented foot step during both rectilinear and curvilinear walks. Key features of the IFOD step counter are that it is possible to detect both right and left steps by instrumenting one foot only and that it does not rely on foot impact dynamics. The IFOD step counter can be combined with existing IMU-based methods for increasing step-detection accuracy.


Asunto(s)
Pie/fisiología , Monitoreo Fisiológico/instrumentación , Caminata/fisiología , Dispositivos Electrónicos Vestibles , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Fotogrametría
18.
J Altern Complement Med ; 25(3): 305-316, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30624952

RESUMEN

OBJECTIVES: Among different exercise models proposed for individuals with Parkinson's disease (IwPD), the popularity of traditional forms of dance is increasing. The aim of this study was to evaluate the effects of Sardinian folk dance (Ballu Sardu, BS) on functional performance and motor and nonmotor symptoms in IwPD. DESIGN: Single-blind, randomized controlled pilot trial. SETTINGS: Outpatient health clinic. SUBJECTS AND INTERVENTIONS: Twenty IwPD (13M, 7F; 67.4 ± 6.1 years) were randomly assigned to BS (n = 10) or usual care (n = 10). The dance program consisted of two sessions/week, 90-min/class, for 12 weeks. OUTCOME MEASURES: Motor and nonmotor symptoms, as well as functional performance, were evaluated using different questionnaires and tests such as the Unified Parkinson's Disease Rating Scale Part-III (UPDRS-III), 6-min walking test (6MWT), Berg Balance Scale (BBS), Timed Up-and-Go (TUG) test, Five Times Sit-to-Stand Test (FTSST), Back Scratch Test (BST), Sit-and-Reach Test (SRT), instrumented gait analysis, Parkinson's Disease Fatigue Scale (PFS-16), Beck Depression Inventory, Starkstein Apathy Scale (SAS), and Montreal Cognitive Assessment (MOCA) scale. RESULTS: Repeated-measures analysis of variance revealed significant Time × Group interactions for UPDRS-III and functional variables such as the 6MWT, BBS, FTSST, TUG (all, p < 0.001), BST (p = 0.04), and gait analysis parameters (stride length, p = 0.031; gait speed, p = 0.049; and gait fatigue index (GFI), p = 0.005). For nonmotor symptoms, significant Time × Group interactions for depression (p < 0.001), apathy (p = 0.016), and MOCA scores (p = 0.012) were observed. Of note, for GFI and SAS, the BS group only showed a trend toward improvement, while the condition of the controls worsened significantly. No between-group differences were observed for SRT and PFS-16. CONCLUSIONS: BS is an enjoyable activity, which has been proved to be superior to usual care alone in inducing changes in different motor and nonmotor symptoms associated with PD. Results show that BS can be considered a safe tool for contrasting impairments observed in IwPD due to the intrinsic nature of the neurodegenerative disease.


Asunto(s)
Danzaterapia/métodos , Enfermedad de Parkinson/terapia , Anciano , Femenino , Humanos , Italia/etnología , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/etnología , Enfermedad de Parkinson/fisiopatología , Proyectos Piloto , Resultado del Tratamiento
19.
Acta Orthop ; 89(6): 656-661, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30558517

RESUMEN

Background and purpose - Gait analysis is indicated in children with cerebral palsy (CP) to identify and quantify gait deviations. One particularly difficult-to-treat deviation, crouch gait, can progress in adolescence and ultimately limit the ability to ambulate. An objective quantitative assessment is essential to early identify progressive gait impairments in children with CP. 3-dimensional gait analysis (3D GA) is considered the gold standard, although it is expensive, seldom available, and unnecessarily detailed for screening and follow-up. Simple video assessments are time-consuming when processed manually, but more convenient if used in conjunction with video processing algorithms; this has yet been validated in CP. We validate a 2-dimensional markerless (2D ML) assessment of knee joint flexion/extension angles of the gait cycle in children and young adults with CP. Patients and methods - 18 individuals, mean age 15 years (6.5-28), participated. 11 had bilateral, 3 unilateral, 3 dyskinetic, and 1 ataxic CP. In the Gross Motor Function Classification System, 6 were at level I, 11 at level II, and 1 at level III. We compared 2D ML, using a single video camera with computer processing, and 3D GA. Results - The 2D ML method overestimated the knee flexion/extension angle values by 3.3 to 7.0 degrees compared with 3D GA. The reliability within 2D ML and 3D GA was mostly good to excellent. Interpretation - Despite overestimating, 2D ML is a reliable and convenient tool to assess knee angles and, more importantly, to detect changes over time within a follow-up program in ambulatory children with CP.


Asunto(s)
Parálisis Cerebral/fisiopatología , Trastornos Neurológicos de la Marcha/fisiopatología , Articulación de la Rodilla/fisiología , Adolescente , Adulto , Fenómenos Biomecánicos , Niño , Femenino , Marcadores Fiduciales , Análisis de la Marcha/métodos , Humanos , Masculino , Trastornos de la Destreza Motora/fisiopatología , Rango del Movimiento Articular/fisiología , Adulto Joven
20.
Biomed Eng Online ; 17(1): 58, 2018 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-29739456

RESUMEN

BACKGROUND: The use of miniaturized magneto-inertial measurement units (MIMUs) allows for an objective evaluation of gait and a quantitative assessment of clinical outcomes. Spatial and temporal parameters are generally recognized as key metrics for characterizing gait. Although several methods for their estimate have been proposed, a thorough error analysis across different pathologies, multiple clinical centers and on large sample size is still missing. The aim of this study was to apply a previously presented method for the estimate of spatio-temporal parameters, named Trusted Events and Acceleration Direct and Reverse Integration along the direction of Progression (TEADRIP), on a large cohort (236 patients) including Parkinson, mildly cognitively impaired and healthy older adults collected in four clinical centers. Data were collected during straight-line gait, at normal and fast walking speed, by attaching two MIMUs just above the ankles. The parameters stride, step, stance and swing durations, as well as stride length and gait velocity, were estimated for each gait cycle. The TEADRIP performance was validated against data from an instrumented mat. RESULTS: Limits of agreements computed between the TEADRIP estimates and the reference values from the instrumented mat were - 27 to 27 ms for Stride Time, - 68 to 44 ms for Stance Time, - 31 to 31 ms for Step Time and - 67 to 52 mm for Stride Length. For each clinical center, the mean absolute errors averaged across subjects for the estimation of temporal parameters ranged between 1 and 4%, being on average less than 3% (< 30 ms). Stride length mean absolute errors were on average 2% (≈ 25 mm). Error comparisons across centers did not show any significant difference. Significant error differences were found exclusively for stride and step durations between healthy elderly and Parkinsonian subjects, and for the stride length between walking speeds. CONCLUSIONS: The TEADRIP method was effectively validated on a large number of healthy and pathological subjects recorded in four different clinical centers. Results showed that the spatio-temporal parameters estimation errors were consistent with those previously found on smaller population samples in a single center. The combination of robustness and range of applicability suggests the use of the TEADRIP as a suitable MIMU-based method for gait spatio-temporal parameter estimate in the routine clinical use. The present paper was awarded the "SIAMOC Best Methodological Paper 2017".


Asunto(s)
Disfunción Cognitiva/fisiopatología , Marcha , Fenómenos Magnéticos , Enfermedad de Parkinson/fisiopatología , Procesamiento de Señales Asistido por Computador , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Análisis Espacio-Temporal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...